Loading...
HomeMy WebLinkAboutBUILDING PLANS (6)R � „ -18 2015BY _ Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 z Certification for DesignLoad Compliance Pr I'ect Name: JU C Pr I; ect Address: Pe] it #: I Occupancy Type: R3! Construction Type: V=B IN1rRUCTIONS FOR USE: s This certification must be completed, signed; and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure'requiring a building permit o Any non -'residential structure. * N ' te: Form not required for interior renovations provided that no exterior structural elements are affected and ce I minor building permits at the discretion of the local building official. Contact the # above for questions. RAMETERS AND ASSUMPTIONS USED: com lete all that apply) �,in N PA (complete 1. DESIGN CODE: Florida Residential Code 2010 Edition with 20 Supplements using ASCE 7-10 2. tructure Designed as (check one): X Enclosed Partially Enclosed Open 3. isk Category: _I X II III _ IV Exposure Category: B X C D 4. esign Wind Velocity 160 mph X ASD _LRFD End Zone Width: See sh2or3 ft 5. can Roof Height 15 ft Roof Pitch: --> :12 Parapet: --� ft (See Sh 2 or 3) 6. omponents & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): +29.5 +32.1 +32.1 +55.8 +55.8 (See Sh 2 or 3) one 1: -50.9 Zone 2: -88.8 Zone 3: -131.3 Zone 4: -60.5 Zone 5: -74-7 Garage: 7. esign Loads: Floor: 55 . PSF Roof/Dead: --� PSF Roof/Live: 20 Balcony: 55 PSF (See Sh 2 or 3) ock: 40 PSF Deck: 55 PSF Stairs: 40 PSF Fence: N/A PSF Railings: 50 plf PSF 8. ere Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. esign Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DES I N PROFESSIONAL CERTIFICATION STATEMENT: Ice i fy that, to the best of my knowledge and belief, the attached plans & specifications have been designed to com iy with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Coun .:.I,als`ci'certiN-that structural elements depicted on these plans provide adequate resistance to the design force rsecified` Steve Kastner, PE 39528 ur- uatd".and Sealeq .z'J . .v ftgvis 07/25/2(714 Print Name Cert # & Co. CertAuth. _ Kastner Engineering, LLC 5320 Florida Palm Ave, Cocoa, FL 32027 Company Name & Address