HomeMy WebLinkAboutNOADEP
SCANNED
BY
RECEIVED
BADE JUL 3 12018 IAMI-DADE COUNTY
ST. Lucie County, pefr# le
CONTROL SECTION
rMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) �_ 1io SW 26 Street, Room 208
AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NC TICE OF ACCEPTANCE NOA www.miumidade.gov/eeonomy
Bor l 1 Roofing LLC.
7575 Irvine Center Drive, Suite 100
Irv' ie, CA 92618
SC i PE:
Thi NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
doc mentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
use in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
Thi' NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In iami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
pr04 uct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manP_er, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it s determined by Miami -Dade County Product Control Section that this product or material fails to meet the
req '�irements of the applicable building code.
Thi product is approved as described herein, and has been designed to comply with the Florida Building Code
inclding the High Velocity Hurricane Zone of the Florida Building Code.
DF$CRIPTION: BORAL TileSeal
NG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in le applicable building code negatively affecting the performance of this product.
TE INATION of this NOA will occur after the expiration date or if there has been a revision or change in the
mat' nials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for 'ales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of ,is NOA shall be cause for termination and removal of NOA.
AD'IVlERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by 1he expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it sfi�all be done in its entirety.
'ECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
be available for inspection at the job site at the request of the Building Official.
renewes NOA413-1113.05 and consists of pages 1 through 4.
submitted documentation was reviewed by Freddy Semino
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 1 of 4
1.
IRT
PRI
PRI
PRI
Teel
[NG COMPONENT APPROVAL
Roofing
Lego : Underlayment
.1: SBS
JCTS DESCRIPTION:
Product Dimensions
TileSeal 36" x 36' rolls
36" x 72' rolls
'ACTURING LOCATION:
wood, NH
CE SUBMITTED:
Test Agency
,rs Laboratories, Inc.
Inc.
It Technologies, Inc.
It Technologies, Inc.
action Materials
ies, LLC.
Test Product
Specification Description
TAS 103 SBS self -adhering asphalt sheet material with a
ASTM D 1970 white glass re -enforced polyester surfacing fabric;
for use as an underlayment in sloped roof
assemblies.
Test Identifier
Test Name/Reyort
Date
R14610
Follow up Service
03/28/02
02-012
TAS 103
02/28/02
NEI-006-02-01
TAS 103
04/01/02
NEI-008-02-01
TAS 114 (H)
07/30/02
NEI-045-02-01
ASTM D 4798 & ASTM G 155
08/08/07
NEI-053-02-01
ASTM D 4798 & ASTM G 155
05/01/08
NEI-076-02-01
TAS 103 / ASTM D4798
02/14/11
NEI-034-02-02 .
ASTM D 1970
01/29/13
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 2 of 4
ASSEMBLIES:
Type 1: Wood, non -insulated
Description: 15/32" or greater plywood or wood plank
m E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" head lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
One or more plies of BORAL TileSeal Underlayment with a minimum 3" head lap and minimum
6" end lap. Place the first course of membrane parallel to the eave, rolling the membrane to
obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with BORAL TileSeal Underlayment is acceptable. All end laps and laps
without black selvage area shall be sealed under lap using an SBS modified mastic.
Note: When used in Tile roof systems BORAL TileSeal Underlayment shall be back nailed to
deck with approved annular ring shank nails and tin caps at a maximum 6" o.c. at the side laps.
No nails or tin caps shall be exposed.
Approved for Approved Adhesive Set Roof Tile Systems, Mechanically Fastened Roof Tile,
Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies.
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 3 of 4
LI ITATIONS:
1. 1 ire classification is not part of this acceptance.
2. 'Ihis acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. BORAL TileSeal underlayment shall be installed in strict compliance with applicable
uilding Code.
3. ORAL TileSeal underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities.
4. 1
IORAL TileSeal underlayment shall not be applied over an existing roof membrane as a recover, but may be
,applied over a roofing Base/Anchor sheet underlayment.
5. ORAL TileSeal underlayment shall not be left exposed as a temporary roof for longer than 180 days of
tplication.
6. The standard maximum roof pitch for BORAL TileSeal underlayment shall be 6:12 when tiles are loaded directly
t the BORAL TileSeal underlayment; loading boards or battens are required on roof pitches greater than 6:12".
7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
s ecific prepared roofing products.
8. 1 1 iles shall be stored on battens on roof pitches greater than 6:12".
9. ORAL TileSeal underlayment may be used with any approved roof covering Notice of Acceptance listing
CORAL TileSeal underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL
'leSeal underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
iami-Dade County Product Control Department for approval provided that appropriate documentation is
'�101nails
'vided to detail compatibility of the products, wind uplift resistance, and fire testing results.
10. in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the h deck thoroughly to remove any dust and debris prior to application.
11. V Id en applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
om the center outward in both directions. For ridge applications, center the membrane and roll from the center
o tward in both directions.
12. �I�11 or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
071,
erlap areas.
13. F'ash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
tice of Acceptance and applicable Building Code.
14. A 11 protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed
i place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal underlayment
shall be applied over the underlayment, and sealed using an SBS modified mastic.
15. A 1 products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
R le 61 G20-3 of the Florida Administrative Code.
16. A 1 membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
d state of manufacturing facility, and the following statement. Miami -Dade County Product Control Approved"
01 the Miami -Dade County Product Control Seal as shown below
C
OMO
END OF THIS ACCEPTANCE
NOA No.: 17-0530.10
Expiration Date: 07/31/18
Approval Date: 07/27/17
Page 4 of 4