Loading...
HomeMy WebLinkAboutICC-ES-REPORT 1473o Lure couniv DIVISION: 06 00 00—WOOD, PLASTICS AND COMPOSITES SECTION: 0616 00—SHEATHING -- s DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 30 05—ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+"rm ROOF SHEATHING ICC . , IC 0MG LISTED Look for the trusted marks of Conformityl "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPQ Award in Excellence" A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. �d Copyright © 20151CC Evaluation Service, LLC. All rights reserved. IMES Evaluation Report ESR-1473* Reissued September 2015 This report is subject to renewal September 2017. wwrwAcc-es.org 1 (800) 423-6587 j (562) 699-0543 A Subsidiary of the international Code Council® DIVISION: 06 00 00—WOOD, PLASTICS, AND COMPOSITES Section: 06 16 00—Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION- - Section:-07 30-05—Roofing Felt and Underlayment REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10925 DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262 (800) 933.9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM® AND ZIP SYSTEM+T" ROOF SHEATHING 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012 and 2009 International Building Codee (IBC) ■ 2015, 2012 and 2009 International Residential Code® (IRC) ■ 2013 Abu Dhabi International Building Code (ADIBC)l 'The ADISC is based on the 2009 IBC. 2009 !BC code sections referenced In this report are the same sections in the ADISC. Properties evaluated: ■ Structural —wind uplift resistance ■ Nonclassified roof covering ■ Classified roof covering ■ Weather resistance 2.0 USES ZIP System® and ZIP System+TM roof sheathing panels are used as combination roof sheathing and roof underlayment. 3.0 DESCRIPTION The ZIP System® and ZIP System+T"' roof Sheathing panels are wood structural panels having a laminated facer. The ZIP System+Tm panels are manufactured using a different resin than the Zip System® panels.. The panels, are installed with a proprietary seam tape, which allows the systems to be used as an alternate to the underlayment required in Chapter 15 of the IBC and Chapter 9 of the IRC. The OSB substrate complies with U.S. DOC PS-2 for wood structural panels and is overlaid on one side with a medium -density, phenol -impregnated, polymer -modified sheet material. The standard -size panels are nominally 4 feet by 8 feet: Oversize -panels, wider than 4 feet (1219 mm) or longer-than-8-feet (2438 mm), or both, are also produced. —The panels -are available with either a square -finished -edge profile a tongue -and -groove edge profile or a machined_ edge profile. The proprietary seam tape is a self -adhering sheet -type membrane consisting of acrylic adhesive laminated to a-polyolefin backing, and the face of the tape is labeled with ESR-1473. The tape is 0.012 inch thick (0.30 mm) with a minimum width of 3 inches (76.2 mm), and comes in rolls of varying length. 4.0 INSTALLATION 4.1 General: Installation of ZIP System® and ZIP System+TM roof sheathing must comply with the applicable code, this report and the manufacturer's published installation instructions. The installation instructions are to be available at the jobsite at all times during installation. The instructions within this report must govern if there are any conflicts between the manufacturer's published instructions and this report. 4.2 Application: The ZIP System® and ZIP System+TM roof sheathing panels must be installed with the longer dimension perpendicular to the roof framing and fastened to the roof framing in accordance with the applicable code for wood structural panels. The panels must be installed in accordance with the panel span rating as shown on the panels. All corners are to be securely fastened. Tongue - and -groove and machined edge panels are designed to provide the correct gap size at the panel edges during Installation. Squared -edged panels must be spaced apart a minimum of '/a inch (3.18 mm) at the time of installation. End joints of adjacent panel runs must be staggered, The panel must be installed with the laminated phenol - impregnated polymer -modified sheet material facing to the exterior. All ZIP System® and ZIP System+TA1 roof sheathing seams must be sealed with the Zip System® tape. All overlay surfaces must be free of any significant presence of debris particles or sawdust prior to installation of the ZIP System tape. Overlay surfaces must be void of any free water prior to application of the ZIP System® tape. The ZIP System® tape edges must be sealed and the tape is to be centered within +/-'/2 inch 1e12.7 mm) of all panel edge seam centers. All ZIP System and ZIP System+TM 'Revised November 2015 (CC -ES Evaluation Reports ore not to be construed as representing aenhbler or any other attributer not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation jar its ure. There dr no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter to this report, a," to any produes covered by the report Copyright 0 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2 ESR-1473 I Most Widely Accepted and Trusted roof sheathing surface defects, openings, cracks, etc., that completely penetrate the overlay and substrate, and caused by handling or construction work, must be covered with the ZIP System® tape. The ZIP Systeme tape must extend a minimum of 1 inch (25.4 mm) past the panel edge T-joint intersections. The ZIP System® tape must be adhered to the ZIP System® and ZIP System+TH roof sheathing. Wrinkles in the ZIP System seam tape are acceptable unless they create a leak path to the panel seam. 4.3 Roof Assemblies 4.3.1 Classified Roof Coverings 4.3.1.1 Class A: Underlayment is not required for a minimum 1/2-anch thick Zip System+Tee roof sheathing with Class A asphalt glass fiber mat shingles. 4.3.1.2 Class B: Underlayment is not required for a minimum 7/18-inch thick Zip Systemoroof sheathing with —Class -A asphalt glass fiber mat shingles. 4.3.2 Nonclassified Roof Coverings: The ZIP System® and ZIP System+Tea roof sheathing panels are limited to —installation on buildings permitted to have nonclassified roof coverings using code -complying asphalt -fiberglass shingles, metal shingles, metal panels, wood shakes, wood shingles, built-up roofing, slate and slate -type shingles, and clay and concrete tile roof coverings. Roof coverings may be applied directly to the taped ZIP System® and ZIP System+TM roof panels unless multi -layer underlayments are required. 4.4 Wind Uplift Resistance: Wind uplift design loads and ZIP System® and ZIP System+TM roof wood structural panel allowable uplift resistance shall be determined in accordance with Sections 1609 and 2304.8.2 of the 20151BC or 2304.7.2 of the 2012 and 2009 IBC and Section R301.2.1 of the IRC. Roof coverings must be fastened to the sheathing with mechanical fasteners sufficient to resist the design uplift load. 5.0 CONDITIONS OF USE The ZIP System® and ZIP System+TM roof sheathing panels described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 This evaluation report and the manufacturer's published installation instructions, when required by the code official, must be submitted at the time of permit application. 5.2 The ZIP System® and ZIP System+TM roof sheathing panels must be manufactured, identified and installed in accordance with this report and the manufacturer's published installation instructions. 5.3 The ZIP System® and ZIP System+TM roof sheathing panels are limited to code -approved structural use for Page 2 of 2 wood structural panels with either a 24/16, 32/16 or 40/20 span rating. SA In jurisdictions enforcing the IBC, the roof covering system incorporating the panels is limited to installations In the following construction types: • Type 111-13 and Type V-B • Type III -A or Type V-A under the conditions specified in footnote d of IBC Table 601 • Type III -A or Type V-A under the conditions specified in footnote b of IBC Table 601, for occupancies other than Group F-1, H, M and S-1 In jurisdictions enforcing the IRC, the roof covering system incorporating the panels may be installed on structures constructed in accordance with the IRC. -5;5 Enclosed attics and rafter spaces must be ventilated in accordance with the applicable code, except where unvented conditioned attic assemblies are permitted by 2015 and 2012 IRC Section R806.5 or 2009 IRC Section R606.4. 5.6 An ice barrier must be provided as required by Section' 1507.2.8.2 of the IBC and Section R905.2.7 of the 2015 IRC and Section R905.2.7.1 of the 2012 and 2009 IRC. 6.7 Installation is limited to roofs having a slope of 2:12 (16.67% slope) or greater. 5.8 ZIP System® and ZIP System+m roof sheathing -panels are manufactured by Huber Engineered Woods, LLC, in Crystal Hill, Virginia; Commerce. Georgia; Broken Bow, Oklahoma; and Easton, Maine, under a quality -control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Wood Structural Panel Roof Sheathing Factory - laminated with an Alternative Roof Underlayment (AC266), dated May 2008 (editorially updated October 2015). 7.0 IDENTIFICATION Each ZIP System and ZIP System+TM roof sheathing panel covered by this report must bear a label that includes the manufacturer's name (Huber Engineered Woods, LLC) and address; the product name; the evaluation report number (ESR-1473); and the grade, performance category and bond classification. The panel mill label and span rating, grade, performance category and bond classification label must be visible on the bottom face of panels, opposite the laminated facer. The ZIP System® tape roll is labeled with the product name and the evaluation report number (ESR-1473). 1CC-ES Evaluation Report ESR-1473 FSC Supplement Reissued September 2015 This report is subject to renewal September 2017. vwvw.icc-es.org 1 (800) 423-8687 1 (562) 699-0543, A Subsidiary of the Intemational Code Council® DIVISION: 06 00 00—WOOD, PLASTICS; AND COMPOSITES Section: 06 16 00--Sheathing DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 30.05—Roofing Felt and Underiayment REPORT HOLDER: — HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE 10926 DAVID TAYLOR DRIVE, SUITE 300 i CHARLOTTE, NORTH CAROLINA 28262 (800) 933-9220 www.huberwood.com EVALUATION SUBJECT: ZIP SYSTEM° AND ZIP SYSTEM+w ROOF SHEATHING 1.0 REPORT PURPOSE AND SCOPE Purpose: The purpose of this evaluation report supplement is to indicate that ZIP System® and Zip System+rm roof sheathing, recognized in ICC-ES master evaluation report ESR-1473, has also been evaluated for compliance with the codes noted below. Applicable code editions: ■ 2014 Florida Building Code --Building ■ 2014 Florida Building Code —Residential 2.0 CONCLUSIONS The ZIP System® and ZIP System+sM roof sheathing, described in Sections 2.0 through 7.0 of the master evaluation report ESR-1473, complies with the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential, provided the design and installation are in accordance with the International Building Code® provisions noted in the master report, and with the condition that wind uplifting design loads must be determined in accordance with Section 1609 of the Florida Building Code —Building and Section R301.2.1 of the Florida Building Code —Residential. Use of the ZIP System® and ZIP System+TM roof sheathing for compliance with the High -Velocity Hurricane Zone provisions of the 2014 Florida Building Code —Building and the 2014 Florida Building Code —Residential has not been evaluated and is outside the scope of the evaluation report. For products failing under Florida Rule 9N-3, verification that the report holder's quality -assurance program is audited by a quality -assurance entity approved by the Florida Building Commission for the type of inspections being conducted is the responsibility of an approved validation entity (or the eade'officiai, when the report holder does not possess an approval by the Commission). This supplement expires concurrently with the master report, reissued September 2015 and revised November 2015 ICC-ES Cvaluation Reporu are not to be contrued as representing aesthetms or any other attributes not tpeefcally addressed nor are they to be construed as on endorsement of the subleci o%the report or o recommendation for as use. There Gr no wornmry by ICC Evaluation Service, LLC. esprvs or implied as to any/lnding or other matter in Afs report, or ar to any product covered by the report. Copyright 0 2015 ICC Evaluation Service, I.I.C. All rights reserved. Page 1 oF1 Florida Building Code Online Search Criteria Page I of 1 Code Version 2014 FL# 17147 Application Type ALL Product Manufacturer ALL Category — _ — - ALL Subcategory - ALt_ Application Status ALL Compliance Method ALL Quallty Assurance.fntlty — -. ALL Quality Assurance Entity Contract Expired ALL — Product Model, Number or Name ALL Product Description ALL Approved for use In HVHZ ALL Approved for use outside HVHZ ALL Impact Resistant — ALL Design Pressure ALL Other Se—!. ALL Eta Type fdanufacti�re_r Validaked By $�S FL17147- Revision Huber Engineered Woods LLC ICC Evaluation Service, Approved EU Category: Structural Components LLC. Hlsto Subcategory: Products Introduced as a Result of New (205) 599.9800 Technology nr tact U :: 2601 Blair Stone Read- Tanaha.wn Fl aZno pnane: R50-�7-1924 The State of Florida Is an AVE EO employer. CoovriaM 2007.2013 sraL of Florida_ :; Prtnry eatem!nC :: ACftSiibPIN StatnrMn! •: RetL d o-, enr Under Florida Law, email addresses are pubix records. It you do not want your e•mall address refused In resporrsa to a public -moms request, do not send eleMnic mail to this entity. tnMd, contact the office by phone or by tradittonaf mall. If you have any questions, please contact 9 0.487.1395. *Pursuant to Section 455.175(1), Florida Statutes, effective October 1, 2012, kensaes flrsnsed under Chapter 455. F.S. must provide the Department with an emaill address It they have one. The emalb provided may be used for official communlmtian w7h the (Ions". However emaill addresses are publ'c record. tfyou do not wish to supply a personal address, please pruvido the Department wlth an email address which con be made available to the publk. To determine If you are a Itcensee under Chapter 455. F.S., please mac hire. Product Approval At[epfa: MOOR® Credit Card Safe https://www.floridabuilding.org/pr/pr�_app_lst.aspx 4/ 12/2017