Loading...
HomeMy WebLinkAboutDESIGN CERTIFICATION FOR WIND LOAD COMPLIANCEU(CANNED Planning & Development Services Department BY Building & Code Regulations Division St. ILUdIR CGUMV 2300 Virginia Avenue Fort Pierce, FL 34982 ILE 712462-1553 f P �. �.:.. v.._ ..- Design Certification for Wind Load Compliant CO3am"I'v This Certification must be completed by the project design architect or engineer. This Certification must be submitted in duplicate with all applications for building permits involving the construction of new residence (single or multi- family), residential addition, any accessory structure requiring a building permit, and any nonresidential structure. This Certification shall not apply to interior renovations (provided that no exterior structural walls, columns or other components are being affected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at (772)462-1553 Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) I Florida Building Code 20 rs'1 Edition with 20 0 9 Supplements and ASCE 7 05 2. Building Design is: Enclosed: iC Partially Enclosed: Open Building: i 3. Mean Roof Height:_ Roof Pitch: 5I Z Internal Pressure Coefficient: 6 4. Width of End Zone: I Wind Speed: I I" (3 sec. gust) 5. Building Classification Table 1-1. ASCE 7_FBC Table 1604.5 — 6. Wind Exposure Classification: 1�:, Adjustment Factor for Exposure & Height: 7. Components & Cladding Wind Pressure on Roof Zone 1-23.7 2 ^41,3. 3 -(-1 •o PSF 8. Components & Cladding Wind Pressure on Wall Zone 4 -264 5 -341 PSF 9. Components & Cladding wind Pressure on Overhead Garage Door Z �-'7 PSF 10. Loads: FIoor '+0 PSF Roof/dead—, 11 PSF Roof/live Z' PSF 11. Shear Walls Considered for Structure? Yes ✓ No (if No, attach explanation) 12. Continuous Load Path provided? Yes ✓ No (if No, attach explanation) 13. Are Component and Cladding... Details Provided?.Yes _✓___No ._ (if No,. attach explanation) 14. Minimum Soil Bearing Pressure: 250 J Presumptive: ✓ By Test: PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name: 1 Knlr--I., Bert #: Design Firm: I;LG 13 E L NG • Date: SLCCDV Form # 020-00 SEAL Revised 2/27/09 (CL) Revised 6/112010 (IS) V... . HARVEYiE.\KOEHNEN Professional Engineer 32831 - t7205 Elyse Circle Port St. Lucie, FL 34962-3212 (772) 489-3035 fax