Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1108-0318-Roofing Submittal Package
M r 1167... 000407 Roofing Submittal Package Project: Pantusso Residence Job Address: 3415 S. Indian River Drive Fort Pierce, FL General Contractor: Malasky Homes, Inc. 1300 N. Florida Mango Road Suite 15 Nest Palm Beach, FL 33409 P#: 561.471.8600 Contact: Date/Info: Bruce Malasky September 2, 2011 JA Taylor Roofing 302 Melton Dr. Ft Pierce, FL 34982 Index: Project: Pantusso Residence Job Address: 3415 S. Indian River Drive Fort Pierce, FL Sections: 1 Scope of Work 2 NOA/Florida Product Approval Underlayment Series 1.101 Englert Panels 3 Data Sheet 4 Color Chart 5 Shop Drawings & Details 6 Englert Contracter Certification Letter 7 Sample 25 Year Finish Warranty S eetion 1 Project: 3415 S. Indian River Dr. Ft. Pierce, FL SCOPE OF WORK ROOFING) Included are the following: Main roof and detached Garage roof Provide and install (1) ply self -adhered underlayment over sheathing Provide and install new drip edge, flashing, counter -flashing, plumbing stacks, vent stacks fabricated from .032 gauge aluminum materials color to match roofing panels. Provide and install 1" standing seam metal roof system with .032 gauge Permametallic 3500" aluminum as manufactured by Englert with 25 year paint finish warranty and 25 year base metal warranty. Color — Pre -weathered Galvalume Chimney and top to have one ply each of peel and stick modified cap sheet w/ drip edge and wall flashing. Mitered hip valleys. Cut to be no greater than 1" Sub -contractor to provide five (5) year "leak Free" workmanship warranty from date of Certificate of Occupancy from St. Lucie County. Daily clean-up, All trash placed into builder provided dumpster Permitting included Excluded: Chimney Cap Soffits Fascia Gutter & Downspout Section 2 LARTI 1. ENGLERT METALMAA HT High Temperature underlayment is a 40 mil self-adhesive waterproofing membrane composed of SBS modified bitumen and a tough 'UV anti -slip polyethylene woven top facer. The release film backing is also UV resistant and protects the product from degradation when stored outside for less than 90 days without the need for a cardboard box. ENGLERT METALCAAN HT is designed for use in high temperature environments where the in-service temperature can reach temperatures as high as 240°F. This self seating, high tensile strength underlayment will provide maximum waterproof protection before, during and after the installation of a metal roof system. FFAT4RES/U--NE Self -adhered High Temperature underlayment Material composed of special elastomeric modified bitumen blends of SBS and other polymers Features tough anti -slip polyethylene woven top facer (100% UV resistant) Designed for use in -extremely hot climates where surface temperatures are as high as 240'F Self-sealing composition provides water proof protection (ASTM D 1970) Excellent heat reflectivity and high tensile strength ensure maximum performance when installed under a metal roof Underlayment can be exposed to the elements for periods of up to 90 days prior to roof being installed Product is easy to install Miami -Dade Compliant NOA ##08-0225.10 Florida Building Code Complaint FL11351.1 I I rp, ftsli MATERIAL COMP?. OT-10' Etastomeric Bitumen Blend of bitumen & SBS polymers Core Material ELastomeric bitumen (Mend of bitumen & SBS polymers) Topside Composition Tri-laminate polyethylene Underside Composition Self adhered with release material M-ATERM RECIFICATIOM. Approx. Nominal Thickness 40 MIL Approx. Gross Roll Coverage 200 FT2 Side Lap (if applicable) 3 IN End Lap (if applicable) 6 IN Roll Length 67 FT Roll Width 36 IN Approx. Roll Weight 40 LBS 25 P! Ej, Rolls per Pallet High Temperature Rating 2407 Part No. 070501 PROUCTICEST REISUIVS, Low Temperature Flexibility ASTM D 1970 -227 Peet Resistance on Plywood ASTM D 903 11.4 LBS/FT Florida Building Code FL 11351.1 Miami -Dade I Product Control Approved NOA #08-0225.10 Load Strain Properties @ 77*F Machine Direction Cross Machine Direction Maximum Load (LBS/IN) 64 88 Elongation @ Maximum Load 52 24 j3j Ctrtjficaie afA taharbition = 8064 Specialt VStructural 19ngineering Evaluation Report Of Englert, Inc. Englert HT" Roof Underlayment for Florida Product Approval FL- 11351.1 Florida Building Code 2007 Method: 1 - D Category: Roofing Sub - Category: Underlayment Product Name: "Enatert HT" Product Type. SBS Self -Adhered Roof Underlayment Prepared for: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 Prepared by: James- 1. Buckner, P.E. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 10-201-HT-ER Revises 09-314-HT-ER.2) Date: 12/20/10 Contents: Evaivation Report Pages I - 4 CRUCK, Inc. 1334S. Killiat Drive, Sufte 4, West Palm Beachi Florida 33403 Phim- e! (561)49149927 Fax: (561)491-992O' WebsiW www-cbulckine-11'et arnes L. Buckner, P.E., SECB Florida P.E. -9 41242 1 ( 9 FL #: FL 11351.1 Date: 12 / 201 10 Report No.: 10-201-141--ER Pate 2 of 4 CGC'Ci:. Ine. Flnridn Cer•tiJienrn gf•.futlrori=auinn =` 8t16-! Specialty Structural Entgineeriing Manufacturer: Product Name: Product Category: Product Sub -Category Englert, Inc. Englert HT" Roofing Underlayment Compliance Method: State Product Approval Rule 9N-3.005 (1) (d) Product Description: "Englert HT" is a self -adhering membrane composed of SBS modified bitumen and a UV resistant anti -slip polyethylene woven top facer designed for use as a roof underlayment in high temperature conditions. "Englert HT" may be used with metal roofing, asphalt shingles, slate, simulated slate, tile or wood shakes shingles. Product Material / Material Type: Styrene Butadiene Styrene (SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code (FBC), 2007, Chapter 15. Product Dimension(s) Roll Size: 36 in. x 67 ft. rolls Thickness: 40 mils minimum Substrate(s): "Englert HT" may be applied to the following substrates: Plywood Wood plank OSB Structural Concrete Gypsum Board Masonry Galvanized metal Installation: Englert, Inc's "Englert HT" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the Florida Building Code, 2007, subject to the System Limitations listed in this Evaluation Report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. 1z L #: FL 11351.1 Date: 13 / ?0 ; 10 Report No.: 10-20141"C-ER. Page 3 of 4 CBtiCK. Inc. Flor-irlu Certificate gfAtrthori_ation , 8064 Specialty Structural. Engineering Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 9N-3.0005 (3) for manufacturing under a quality assurance program audited by an, approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). Performance Standards: The product described herein has been tested in accordance with: ASTM D 1970-01— Specification Self -adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for ice Dam Protection ASTM D 4798-04 — Standard Practice for Accelerated Weathering Test Conditions and Procedures for Bituminous Materials (Xenon -Arc Method) Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2007, Section 1507.2.4, 1507.3.3, 1507.5.3, and 1507.6.3. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section of Florida Product Approval Rule 9N-3.001. Fire Classification: Fire Classification is outside the scope of Rule 9N-3. and is therefore not included in this evaluation. System Limitations: Installation is for prepared roofing applications. Minimum deck and slope requirements to be in compliance with applicable code sections of the Florida Building Code, 2007. Underlayment shall not be applied over existing roof membranes. Installation with the roofs shall comply with FRSA/TRI 0,7320/8-05 Installation Method, Fourth Edition. This report does not evaluate use of this product in the High Velocity Hurricane Zone. Referenced Data: 1. ASTM D 4798-04 & ASTM D 1970-01 Test By Trinity ER®, (FBC Organization #TST ID: 6049) Report #: E12330.01.09, Report Date: 1/14/09 2. Quality Assurance By Keystone Certifications, Inc. (FBC Organization #QUA ID:1824) 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization # ANE ID: 1916) FL #: FL 11351.1 Date: 12 / ?0 / 10 Report No.: 10-20 1 -1 IT-L R Paee 4 of 1 UCK n ineerin CB1;CK, lne. Florida Cer1111caW gf',4111110"iZa1ion 8064 Specialty Structural Engineering INSTALLATION METHOD Englert HT" Self -Adhered Roofing Underlayment optional) Prime substrate prior to installation. Align the membrane, by completely unrolling and pressing exposed membrane area into place. Once aligned, wind back one half of the length. Score the release film on the high side of the roll. Unroll the first half of the roll by peeling back the release film and simultaneously pushing out the membrane. Repeat this procedure with the remaining half of the length. Firmly roll installed membrane using unitorm pressure with a 2-3" heavy steel or rubber roller to seams and overlap. Side laps must be a minimum of 3" and End laps a minimum of'6". Product to be applied directly to a clean dry surface. Dust, dirt, oil, grease, moisture, debris and other loose materials or contaminants must be removed prior to application. Check that all nails in deck are not protruding and re -fasten any loose decking panels. Product shall not be permanently exposed to sunlight. Do not store underlayment in areas where moisture is a problem. Protect membrane from damage during construction. Apply membrane only in Lair weather when the air, surface and membrane are at temperatures of 40 degrees Fahrenheit and higher. Englert HT" shall not be left exposed for more than 90 days after installation. Englert HT' may be used with asphalt shingles, metal rooting, slate, simulated slate, tile or wood shakes & shingles. Installation with the roofs shall be in compliance with FRSA/TRI 073-20/8-05 Installation Method, Fourth Edition, and is limited to the.tollowing: System 1, Option 5 or 6, Section 3.02E or F System 2, Option 4 or 5, Section 3.02D or E Refer to the manufacturer's installation instructions as a supplemental guide for attachment. 1 1 /4" Integral Snap -Lock ngiert Series Al 100 With only a 1 Y4" high standing seam, the A1100 snap -lock panel offers the designer an architectural system for creating clean roof lines with a n?inimurn of shadows and cetitures. Roofing Clips Flashing Fasteners Premium Underla,rment Metalt'.4an HT Underlavment PreManUfaccured Curbs Cor-A-`Dent Forming Tools Sealants Touch Up Paint Materials and Gauges ULTRA -Cool'" lour gloss paint finishes System Warranties Ratings and Certifications Coil and Coil Purchasing S Ji )t: !i:i 7,:.I t.. ti.•iir i; Specifier Sheets i• is ' rh l a rTr " - -' Fi 4 Y f ,, 1 r - 4 N k • '' M1i. ` •: • ( I1, II i'I Ei' 2,• Li ir t:,,F a - :: -. _ ;sue .E• • 6 r' wire.... Alt 00 Animation color Chart ®rawi gs PROFILE AT A GLANCE Structural Architectural detail capability Tight radius curving capacity Shallow slope (less than 3"/12") Narrow seam Wide seam Flush seam Snap -lock seam Good for mansard or fascia UL-90 tested Florida Building Code Compliant ASTM water & air tested Dade County tested ASTM E-84 tested (Class A Fire rating) ASTM E-1592 tested Weather tightness warranties Fl©rich Building Code Online Pagel of 4 AN s r y a . , # , i'° .#Fu, .».. BCIS Home Log In User Registration i Hot Topics Submit Surcharge Stats & Facts Publications FBC Staff BCIS Site Map Links Search Product Approvalk01- USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL11698 Application Type Uew--, Code Version 2007 I Application Status Approved Comments Archived Product Manufacturer Englert Inc. Address/Phone/Email 1200 Amboy Ave. Perth Amboy, NJ 08861 732) 826-8614 Ext3909 j.tripod@englertinc.com Authorized Signature James L. Buckner P.E.@CBUCK Engineering jimmy@cbuckinc.net Technical Representative Joseph F. Tripod Address/Phone/Email 1200 Amboy Avenue Perth Amboy, NJ 08862 732) 826-8614 jftripod@aol.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer F Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who James L. Buckner, P.E @ C-Buck, Inc. developed the Evaluation Report Florida License PE-31242 Quality Assurance Entity Keystone_Certifications, Inc. Quality Assurance Contract Expiration Da 12/31/2011 Validated By Steven M. Urich, PE F Validation Checklist - Hardcopy Received Certificate of Independence FL11698 RO COI CertOfIndep.pdf Referenced Standard and Year (of Standard) Standard Year Florida Building Code 2007 TAS 125 2003 http://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2ffrZeD%2bAMp9rG'lU... 7/13/201 l Florida Building Code Online Page 2 of 4 UL 1897 1998 UL 580 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 11/24/2008 Date Validated 12/19/2008 Date Pending FBC Approval 12/28/2008 Date Approved 02/03/2009 Summary of Products 1 FL # Model, Number or Name Description 11698.1 1 - Englert "Se IRoof Panel - 26 Gauge Steel, 21" Width, Attached to Plywood Deck I Limits of Use Approved for use in HVHZ: No Installation Instructions FL11698 RO II 1 Series500 26GaSteelOnWood EVALREPORT.odf Verified By: James L. Buckner, P.E P.E. #31242IApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/-79 Other: The required design wind loads shall Evaluation Reports FL11698 RO AE 1 Series500 26GaSteelOnWood EVALREPORT odf Created by Independent Third Party: YesbedeterminedforeachprojectperFBC, 2007, Section 1609. The maximum fastener spacing listed herein shall not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with FBC 2007, Sections 104, 105, 106. This report does not evaluate use of this product in the High Velocity Hurricane Zone. 1111698.2 2 - Englert "S IRoof Panel - 0.032" Aluminum, 21" Width, Attached to Plywood Deck Limits of Use Installation Instructions I Approved for use in HVHZ: No FL11698 RO II 2 Series500 032AIumOnWood EVALREPORT.odf Verified By: James L. Buckner, P.E P.E. #31242ApprovedforuseoutsideHVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes j Design Pressure: +N/A/-84 Evaluation Reports Other: The required design wind loads shall FL11698 RO AE 2 Series500 032AIumOnWood EVALREPORT.odf Created by Independent Third Party: YesIbedeterminedforeachprojectperFBC, j 2007, Section 1609. The maximum fastener spacing listed herein shall not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with FBC 2007, Sections 104, 105, 106. This report does not evaluate use of this product in the High Velocity Hurricane Zone. 11698.3 3 - Engler"Series 1000" Roof Panel - 24 Gauge Steel, 20" Width, Attached to Plywood Deck Limits of Use Installation Instructions Approved for use in HVHZ: No FL11698 RO II 3 Series1000 24GaSteelOnWood EVALREPORT.odf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Evaluation Reports Other: The maximum fastener spacing FL11698 RO AE 3 Series1000 24GaSteelOnWood EVALREPORT.od Created by Independent Third Party: Yeslistedhereinshallnotbeexceeded. All deck butt and side joints shall be sealed by tape j and/or with a one -part urethane caulk sealant per the tested condition. The i- required design wind loads shall be http://floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2fTrZeD%2bAMp9rG3 U... 7/13/2011 G.. gin. r CBUCK, Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Evaluation Report Of Englert, Inc. Series 1101" Metal Roof Assembly for Florida Product Approval FL 11698.6 Florida Building Code 2007 Per Rule 9B-72 Method: 1- D Category: Roofing Sub - Category: Metal Roofing Product: Series 1101"Roof Panel Material: Steel Panel Thickness: 24 Gauge Panel Width: 16" Support Type: Wood Deck Prepared for: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 Prepared by: James L. Buckner, P.E. Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 08-148-1101-S4W-ER Date: 10 / 22 / 08 Contents: Evaluation Report Pages 1 — 6 1 WJ s L. Buckner, P.E. Florida E. # 31242 7 11 /05 CBUCK, Inc. 1334 S. Killian Drive, Suite 4, Nest Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Entail: chuck,,"a)cbuckinc.net FL #: FL 11698.6 Date: 10 / 22 / 08 ReportNo.: 08-148-1 101-S4W-ER Page 2 of 6 CBUCK, Inc. Florida Certificate of Authorization # 8064 Specialty Structural Engineering Manufacturer: Englert, Inc. Product Name: "Series I101" Panel Product Category: Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 9B-72.070 (1) (d) Panel Description: "Series 1101 ", Nailstrip, Steel Roof Panel attached to Wood Deck Panel Material / Standards: Material: Steel Yield Strength: 40 ksi minimum Corrosion Resistance: Material shall comply with the Florida Building Code (FBC), 2007 Section 1507.4.3. Panel Dimension(s) Thickness: 24-gauge minimum Width: 16" (Maximum net coverage) Rib Height: 1" Support Type: Wood Deck Design of support system is not included in this evaluation) Support Description: . l 9/32" or greater plywood, or Wood plank Slope Range: Minimum slope shall be 3:12 or greater in accordance with the Manufacturers recommendations and in compliance with FBC 2007, including Sections 1507.4.2 and 1504.7. Underlayment: Underlayment shall be per manufacturer's guidelines as required in FBC Section 1507. 4.5 Fire Classification: Fire Classification is outside the scope of Rule 9B-72, and is therefore not included in this evaluation. Additional approved substrates may be added for Fire Classification purposes. FL #: FL 11698.6 Date: 10 / 22 / 08 Report No.: 08-148-1101-S4W-ER Page 3 of 6 Specialty Structural Engineering CBUCK, Inc. Florida Certificate ofAuthorization # 8064 Attachment Component Roof Panel Fasteners Description: Size: #10 x 1" (3/] 6"minimum penetration through deck) Type: Pancake -Head wood screws Corrosion Resistance: Per FBC Section 1507.6.6 and 1507.4.4 Standard: Per ANSUASME B 18.6.1. Installation: Englert "Series 1101" Roof Panel to Wood Deck: Fastener Spacing: 6" o.c. maximum at the nailstrip, along the length of the panel and nominally within 3" from all ends) Rib Interlock: Snap -Lock Panel ribs shall be fully engaged to form an integral snap -lock.) Minimum fastener penetration or embedment into deck, 3/l 6". Design Uplift Pressure: - 124 PSF ( Safety Factor of 2 : 1 ) Install the system in compliance with the attached installation method. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL #: FL 11698.6 Date: 10 / 22 / 08 Report No.: 08-148-1 101-saw-ER Page 4 of 6 k1U Enoineering I CBUCK, Inc. Florida Certificate ofAuthori_ation # 8064 Specialty Structural Engineering Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 913-72.070 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) Performance Standards: The product described herein has demonstrated compliance with: UL580- 94 — Test for Uplift Resistance of Roof Assemblies —with Revisions through February 1998 UL 1897-98 — Uplift test for roof covering systems TAS 125-03 — Standard Requirements for Metal Roofing Systems Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2007, Section 1504.3.2 Evaluation Report Scope: This product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code, as related to Rule 913-72. System Limitations: The required design wind loads shall be determined for each project per FBC, 2007, Section 1609. The maximum fastener spacing listed herein shall not be exceeded. Any rational analysis computations shall be prepared by a qualified design professional and in compliance with FBC 2007, Sections 104, 105, 106. Any extrapolation shall address fastener spacing and panel interlock strength. This report does not evaluate use of'this product in the High Velocity Hurricane Zone. Referenced Data: 1. TAS 125 Uplift Test By Hurricane Test Laboratories, Inc. (FBC Organization #TST ID: 1527) Report # 0155-0714-04, Specimen #1 Date: 9/21/04 2. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) Englert, Inc. Licensee # 420 3. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering FBC Organization# ANE ID: 1916) 4. Engineering Analysis By CBUCK Engineering Report # C08-148, Dated 1 1 /21 /08 V w FL #: FL 11698.6 Date: 10 / 22 / 08 ReportNo.: 08-148-1101-saw-cR Page 5 of 6 BUCKEngineering CBUCK, / nc. Florida Certificate ofAuthori<ation 4 8064 Specialty Structural Engineering Installation Method Englert, Inc. Series 1101" ( 24 Ga. Steel) Roof Panel Attached to Wood Deck Integral Snap L Profile Drawings 16" Panel Profile v Screw Typical Assembly Profile View Wood Deck 3/4" 1 v FL #: FL 11698.6 Date: 10 / 22 / 08 Report No.: 08-148-1101-s4w-ER Page 6 of 6 BU X _.. Specialty Structural Engineering CBUCK, Inc. Florida Certificate ofAuthorization # 8064 Installation Method Englert, Inc. Series 1101" (24 Ga. Steel) Roof Panel Attached to Wood Deck r7--4-..-- .- V V VI\ 19/32" Wood Deck Typical Assembly Isometric View Series 1101" Section 3 PermaC®tar 3500 ® Full Strength 70% Kynalr ;S®OYFlylar 50001 All colors available in Galvalume and Aluminum (.032e, .040n & .050"). See your local sales representative for more informatio SunNet Blue NEW Hartford Green Dark Bronze Makhes SunNet 61PV Laminate R 28.1 • E.9 • SRI 29.7 R 29_ I • E.9 • SRI 31 Mansard Brown Burgundy R 31 • E.9 • SRI 33.4 R 35.4 • 6.9 • SRI 39.2 Royal Blue Forest Green matte Black Medium Bronze Colonial Red R 28 • E.9 o SRI 29.6 R 28.7 • E.89 • SRI 30 R 28.2 • E.9 • SRI 29.8 R 32.3 • E.91 • SRI 35.6 R 36.8 • E.9 • SRI 41 Pacific Blue €eerglade Mass Charcoal Gray Sierra Tan Deep Red R 28.5 • E.9 • SRI 30.1 R 32 • -E9 • SRI 34.7 R 30.1 • E.9 • SRI 32.3 R 35 • E.91 • SRI 39.1 R 42 • E.91 • SRI 48.2 Slate Blue Patina Green Slade Gray Sandstone Terra Cana NEW R 31 a E.91 • SRI 33.9 R 39 • E.91 • SRI 44.3 R 40.3 • E.9 • SRI 45.6 R 51 • E.9 • SRI 59.8 R 34.8 • E.89 • SRI 37.9 Bone White Hemlock Green Dove Gray Stone White. R 67 • E.9 • SRI 81.4 R 28 • 'E.92 • SRI 30.4 R 28 • E.9 • SRI 29.6 R 62.5 • E.9 • SRI 75.3 R - Denotes Reflectivity E - Denotes'Emissivity SRI - Denotes Solor Reflective Index Due to the (imitations of printing processes, this color chart is mat an accurate representation of our actual colors. Sample chips are available an request at no charge. Colors available as of 312009 FinishMill A t c Golvalume-Plus° R 68 • E.10 •SRI 54.5 CAM E 4=0 FOR DUMS I-BMENGtERT Permoftlallics 3500• Metallic Copper R 43.8 • E.9 • .SRI 50.2 R 38.4 • 'E.9LSR143.5 Preweathered Gahralume® R 45.7 • E.91 • SRl 53.1 These are premium priced Section 4 ENGLERTE' 2&2011 J. A. Taylor Roofing Inc. 302 Melton Dr. Ff. Pierce, Fl. 34982 RE: Englert Certification Contractor in Good Standing To Whom It May Concern, MAIN MANUFACTURING / HOME OFFICE 1200 Amboy Avenue • Perth Amboy N3 08861 Tel: (732) 826-8614 • Fax: 732) 826-8865 www.englerUm.com Please be advised that J.A. Taylor Roofing is currently in compliance with all of Englert's requirements to maintain its status as a certified Englert roofing contractor. J. A. Taylor is in good standing with Englert and is fully authorized to administer Englert Weather Tightness Warranties. I A. Taylor is also among the preferred group of contractors who receives leads on roofing opportunities from Englert. Sincerely, David Handier Architectural Representative Florida/Caribbean Region Section 5 LIMITED ROOFING WARRANTY - QOV(StOI14 Reissrred -- 7211; 2003 ENGLERT I. INTRODUCTION This warranty covers three separate and distinct products as outlined below: 1. Prepainted Aluminum Warranri When located within one half mile from the seacoast, salt water, or brackish water a 25-year limited warranty on the aluminum, a 25-year limited warranty on PermaColor 2000 paint colors and PermaColor 3500 ULTRA-Coollil low gloss paint colors, a 25-year limited warranty on PermaMetallic 2000 paint colors, and a 25-year limited warranty on PermaMetallic_ 3500 ULTRA -Cool@) low gloss paint colors When located over one-half mile from the seacoast, salt water, or brackish water a 30-year limited warranty on the aluminum, a 30-year limited warranty on PermaColor 2000 paint colors, a 35-year limited warranty on PermaColor 3500 ULTRA -Cook@) low gloss paint colors, a 30-year limited warranty on PermaMetallic 2000 paint colors, and a 35-year limited warranty on PermaMetallic 3500 ULTRA -Cool® low gloss paint odors 2. Prepainted GalvalumeO Warranty When located over one-half mile from the seacoast, salt water, or brackish water a 25-year limited warranty on the metal, a 30-year limited warranty on PermaColor 2000 paint colors, a 35-year limited warranty on PermaColor 3500 ULTRA -Cool@) low gloss paint colors, a 30-year limited warranty on PermaMetallic 2000 paint colors, and a 35-year limited warranty on PermaMetallic 3500 ULTRA -Cool@) low gloss paint colors When located within one half mile from the seacoast, salt neater, or brackish water there is no warranty on prepainted Gavalume@). 3. Mill Finish Galvalume@ Warranty When located over one -haft mile from the seacoast, salt water, or brackish water a 25-year warranty on a (AZ55 coating weight) or 20-year warranty on a (AZ50 coating weight) on the bare metal. When located within one-half mile from the seacoast, salt water, or brackish water there is no warranty on the bare metal. NOTE: ONLY PREPAINTED ALUMINUM IS UNDER WARRANTY WHEN THE PRODUCT IS PLACED WITHIN ONE-HALF MILE FROM THE SEACOAST, SALT WATER, OR BRACKISH WATER. BARE ALUMINUM IS NEITHER WARRANTED NOR OFFERED FOR SALE IN MILL FINISH APPLICATIONS. GENERAL INFORMATION Englert Inc., Perth Amboy, New Jersey, (hereinafter referred to as 'Englert') hereby issues the following paint finish warranty and base metal warranty to the original and first owner(s) of the project and/or building where Englert's coil and flat stock is used for formed roofing, fascia, mansard, wall, siding and soffit applications. The warranted paint systems will be the PermaColor 2000, PermaMetallic 2000, PermaColor 3500 ULTRA-CookA low gloss, and PermaMetallic 3500 ULTRA-CoolG• low gloss paint colors which is comprised of a full-strength 70% Kynar 50D®/ Hylar 50009 Fluorocarbon. Aluminum will only be offered as a prepainted product. Galvalume® will be offered in prepaint, as a passivated mill finish, or as an acrylic coated mill finish product in both AZ55 or AZ50 coating weights (hereinafter to be referred to as "Product") Englert warrants only to the original and first owner(s) that its product: Upon delivery, the material will be free from defects, excluding any freight damage. ( The term 'the material will be free from defects" does not include waviness present in the flat/planer areas of Englen's product, due to inconsistency in the metal making process and uneven substrates over which the product in applied, which the industry has accepted as being prevalent and normal.) Waviness shall not be a cause for a claim under this or any other warranty. ENGLERT INC.'S 25-YEAR, 30-YEAR, OR 35-YEAR PERMACOLOR 20001 3500 AND PERMAMETALLIC 2000 13500 PAINT FINISH WARRANTY The paint finish on Englert's PermaColor 2000 / 3500 and PermaMetallic 2000 / 3500 is comprised of a full-strength 70% Kynar 5000D /Hylar 50000 fluorocarbon paint which will not. Chip, crack, check, or peel. (These terms shall not mean deviations to the paint finish as a result o1 exposed raw edges, or as a result of roll - forming, embossing, and end cutting of Product which may occur in and during proper fabrication of the Product.) Chalk in excess of eight (8) numerical ratings, when installed 0 degrees to 86 degrees from vertical, when measured in accordance with the standard test procedures as specified under ASTM 04214-89. Fade in excess of five (5) E Units (NBS), when installed 0 degrees to 86 degrees from vertical, measured on exposed painted surfaces which have been cleaned of external deposits, as determined under ASTM D-2244-85, Paragraph 6.3. Color change shall be measured on an exposed, painted surface that has been cleaned or surface soils and chalk, and the corresponding values measured on the original or unexposed, painted surface, equally exposed to the sun and elements. This paint finish warranty applies only to Englert's pre -painted coils and Flat stock in steel or aluminum used for formed roofing, fascia, mansard, wall, siding, and soffit applications and only to Product erected within the Continental United States and has been exposed to normal atmospheric conditions. This warranty does not apply to product exposed at any time to corrosive or aggressive atmospheric conditions, including. but not limited to: Areas subject to salt -water marine atmospheres or to constant spraying of either salt or freshwater. (Except pre -painted aluminum.) Areas subject to fallout or exposure to corrosive chemicals, fumes, ash, cement dust, animal waste or its decomposition by-products, carbon black, or fallout from copper, lead, nickel or silver mining or refining operations. Areas subject to water run-off from lead or copper flashing or piping or areas in contact with lead or copper. Conditions/ circumstances where corrosive fumes or condensates are generated or released inside the building. This warranty DOES NOT APPLY in the event of: 1. Bends less than 4T inside bend diameter for all coil and flat stock thicknesses. 2. Roof or sections of the roof flatter than %:12 slope. 3. Mechanical, chemical, or other damage sustained during shipment, storage, forming, fabrication, or during or after erection including damage caused by walking on the roof. 4. Forming which incorporates severe reverse bending or which subjects the coating to alternate compression and tension. 5. Failure to provide free drainage of water, including internal condensation, from overlaps and all other surfaces of the sheets or panels. 6. Any form of moisture entrapment resulting from, but not limited to, the improper handling, fabrication and/or installation of the product. Moisture entrapment due to the improper handling. fabrication, and/or installation of the product may cause product failure 7. Failure to remove debris from overlaps and all other surface of the sheets or panels. B. Damage caused to the metallic coating by improper forming (including, but not limited to, rot/ forming, press braking or embossing) or scouring or cleaning procedures. 9. Deterioration of the panels caused by contact with green or wet or pressure -treated lumber, or wet storage stain caused by water damage or condensation. 10. Presence of damp insulation, soil, vegetation, cement, or other corrosive materials in contact with or in close proximity to the sheets or panels. 11. Deterioration to the panels caused directly or indirectly by panel contact with fasteners or by overdriving the fasteners so as to damage the panel. Selection of suitable long-lasting fasteners to be used with aluminum and Galvalume panels rests solely with the Buyer. Fasteners are to be electrically insulated from the panel surface (e.g.. with elastomeric grommets) to prevent dissimilar metal contact. 12. Failures caused by acts of God, falling objects, external forces, hurricanes, explosions, fires, riots, civil commotions, acts of war, terrorist acts or radiation. 13. The installation of any unapproved fixture, attachment, device, equipment, accessory, or appurtenance_ to, upon, or through the Product, including but not limited to, snow guards. lightning protection, solar panels, or communications devices. Englert reserves the sole and exclusive right to approve the installation of any such fixture, attachment, device, equipment. or accessory. This approval shall be in writing and must be signed by an authorized officer of Englert. a. Regardless of any installation approval by Englert, any Product failure caused by, arising from, or relating to the installation of any such products or devices as listed above voids this warranty. The limited warranty does not extend to, or cover: (a) any damage to the coating system caused by the installation of the photovoltaic cells laminates; b) any damage to coating system caused by removal of the photovoltaic cells laminates: (c) any differential fade or chalk caused by removal of, differential shielding by or reflection of light by the photovoltaic cells laminates; (d) damage, discoloration, differential fade or chalk due to run off from the photovoltaic cells laminates as a result of cleaning, rain, etc. (e) any damage caused by water entrapment by the photovoltaic cells laminates: or (f) any deficiency in the leaning, photovoltaic cells laminates pretreatment. or failure of the photovoltaic cells laminates for any reason This limited warranty will only extend to, or cover applications of photovoltaic cells laminates where the photovoltaic cells laminates are applied over profiles where there are no panel ribs or where striations are either absent or are less than or equal to 15 degrees. This paint finish warranty is strictly limited to the Product as outlined herein and shall not apply to failures, leaks, or consequential damages caused by application of the Product. This paint finish warranty is offered to the original owner(s) only, who is the registered purchaser of the Product, and is not transferable or assignable. Englert expressly precludes others from claiming, representing, or implying that this paint finish warranty extends to or is available to anyone other than the original and first owner(s). It is the responsibility of the building owner(s) to maintain such identification records for purposes of exercising the rights under this paint finish warranty throughout the duration of the paint finish warranty period. All claims must be submitted in writing to Englert within the paint finish warranty period and within thirty (30) days after discovery of the claimed defect. Failure to timely submit a claim is a breach of the Warranty and no coverage under this Warranty will be afforded for the claim. The claim must describe the defect and refer to the paint finish warranty, date of issuance, and include the name of the contractor and invoice of purchase. Englert will then examine the Product or cause it to be examined. If after inspection by Englert it is determined that the claim is valid and in accordance with the terms of the Warranty, Englert agrees at its option to repair or replace the defective Product. Englert will assume 100% of the cost of refinishing or replacing Product on a non -prorated basis for 25-years, 30-years, or 35-years (in accordance with the applied warranty as outlined in Section 1) from the dale of installation. The basis for computing cost of refinishing or replacing Product shall be at the current market price. Englert will have sole discretion as to whether the Product is to be refinished, or replaced. If Englert determines that refinishing is the appropriate measure to be taken, then the building owner(s) shall extend a license to Englert or to any of its authorized representatives or contractors to proceed with uninterrupted work for such refinishing. The building owner(s) shall indemnify and hold Englert or any of its agents, authorized representatives, or contractors, harmless from any damages or claims arising out of or connected with such refinishing, provided that such indemnification shall not extend to acts of negligence by Englert, its agents, employees, authorized representatives or contractors. In the event replacement of Product is deemed necessary by Englert, it shall mean and is limited to Englert furnishing replacement Product only, F.O.B. Perth Amboy, New Jersey. The term "replacement' does not include labor costs of Product removal, fabrication, or installation. The refinished or replaced product shall be warranted for the unexpired tern of the original warranty. This paint finish warranty does not confer upon the owner(s) the right to refinish, restore, repair, or replace Product without a written authorization executed by a duly authorized officer of Englert. Any restoration, refinishing, repairing, or replacement of Product not authorized in writing by a duly authorized officer of Englert shall result in this warranty becoming null and void. On prepainled aluminum product located less than a half mile from a seacoast, salt water, or brackish water, annual maintenance must be performed by the owner(s) including annual "sweet water' (fresh tap water) rinse in accordance with AAMA 610.1-1979 (copy available upon request). It will be the owner's responsibility to maintain records to demonstrate this maintenance has occurred and such records must be delivered to Englert upon request. The Product must not be cleaned with abrasive or chemical cleaners and will result in the paint finish warranty to become null and void. IV. ENGLERT INC. LIMITED 25-YEAR OR 20-YEAR BASE METAL WARRANTY This portion of the warranty applies to the base metal of aluminum and Galvalume as outlined below. The paint finish is covered in Section III. A. 25-years on aluminum only as a prepainted product and located less than a half mile from the seacoast salt water or brackish water. B. 30-years on aluminum only as a prepainted product located a half mile or greater from the seacoast, salt water or brackish water. C. 25-years on prepainted Galvalume@ AZ50 or AZ55 coating weight or Galvalume Mill Finish passivated AZ55 or Galvalume Mill Finish Acrylic Coated AZ55 coating weight. The warranty is void for product placed less than a hag mile from the seacoast salt water, or brackish water. D. 20-years on Galvalume Mill Finish passivated AZ50 or Galvalume Mill Finish Acrylic Coated AZ50 coating weight. The warranty is void for product placed less than a half mile from the seacoast, salt water or brackish water. Englert's base metal warranty on aluminum and Galvalume (AZ50 or AZ55) is to the original and first owner(s) from the date of installation for the periods outlined above; the base metal of aluminum and Galvalume® will not rupture, fail structurally, or perforate due to exposure to normal atmospheric conditions, If erected within the Continental United States. Visual or cosmetic variations caused by weathering of mill finish Product or variations in spangle are specifically excluded from this base metal warranty. The Product shall be free from material defects, excluding any freight damage. LIMITED ROOFING WARRANTY - Revision 4 Reissued— 12/1/2008 10 ENGLERT' This warranty DOES NOT APPLY to coil and flat stock exposed at any time to corrosive or aggressive atmospheric conditions, including, BUT NOT LIMITED TO: Areas subject to salt -water marine atmospheres or to constant spraying of either salt or freshwater. (Except pre -painted aluminum.) Areas subject to fallout or exposure to corrosive chemicals, fumes, ash, cement dust, animal waste or its decomposition by-products, carbon black, or fallout from copper, lead, nickel or silver mining or refining operations. Areas subject to water run-off from lead or copper flashings or piping or areas in contact with lead or copper. Conditions/circumstances where corrosive fumes or condensates are generated or released inside the building. This warranty DOES NOT APPLY in the event of: 1. Bends less than 4T inside bend diameter for all coil and flat stock thicknesses. 2 Roof or sections of the roof flatter than %:12 slope. 3. Mechanical, chemical, or other damage sustained during shipment, storage, forming, fabrication, or during or after erection including damage caused by walking on the roof. 4. Forming which incorporates severe reverse bending or which subjects the coaling to alternate compression and tension. 5. Failure to provide free drainage of water, including internal condensation, from overlaps and all other surfaces of the sheets or panels. 6. Any form of moisture entrapment resulting from, but not limited to, the improper handling, fabrication and/or installation of the product. Moisture entrapment due to the improper handling, fabrication, and/or installation of the product may cause product failure 7. Failure to remove debris from overlaps and all other surface of the sheets or panels. 8. Damage caused to the metallic coating by improper forming (including, but not limited to, roll forming, press braking or embossing) or scouring or cleaning procedures. 9. Deterioration of the panels caused by contact with green or wet or pressure -treated lumber, or wet storage stain caused by water damage or condensation. 10. Presence of damp insulation, soil, vegetation, cement, or other corrosive materials in contact with or in close proximity to the sheets or panels. 11. Deterioration to the panels caused directly or indirectly by panel contact with fasteners or by overdriving the fasteners so as to damage the panel. Selection of suitable long-lasting fasteners to be used with aluminum and Galvalume panels rests solely with the Buyer. Fasteners are to be electrically insulated from the panel surface (e.g., with elastomerfc grommets) to prevent dissimilar metal contact. 12. Failures caused by acts of God, failing objects, external forces, hurricanes, explosions, fires, riots, civil commotion, acts of war, terrorist acts or radiation. 13. The installation of any unapproved fixture, attachment, device, equipment, accessory, or appurtenance to, upon, or through the Product, including but not limited to, snow guards, lightning protection, solar panels, or communications devices. Englert reserves the sole and exclusive right to approve the installation of any such fixture, attachment, device, equipment, or accessory. This approval shall be in writing and must be signed by an authorized officer of Englert. a. Regardless of any installation approval by Englert, any Product failure caused by, arising from, or relating to the installation of any such products or devices as listed above voids this warranty. The limited warranty does not extend to, or cover: (a) any damage to the coating system caused by the installation of the photovoltaic cells laminates; (b) any damage to coating system caused by removal of the photovoltaic cells laminates; (c) any differential fade or chalk caused by removal of, differential shielding by or reflection of light by the photovoltaic cells laminates; (d) damage, discoloration, differential fade or chalk due to run off from the photovoltaic cells laminates as a result of cleaning, rain, etc. (e) any damage caused by water entrapment by the photovoltaic cells laminates; or (f) any deficiency in the cleaning, photovoltaic cells laminates pretreatment, or failure of the photovoltaic cells laminates for any reason. This limited warranty will only extend to, or cover applications of photovoltaic cells laminates where the photovoltaic cells laminates are applied over profiles where there are no panel ribs or where striations are either absent or are less than or equal to 15 degrees. This base metal warranty applies only to Product used for formed roofing, fascia, mansard, wall, siding. and soffit applications and only to Product erected within the Continental United States which have been exposed to normal atmospheric conditions. This base metal warranty is strictly limited to the Product as identified above and shall not apply to failures, leaks, or consequential damages caused by application of the Product. This base metal warranty is offered to the original owner(s) only, who is the registered purchaser of the Product, and is nontransferable or assignable. Englert expressly precludes others from claiming, representing or implying that this warranty extends to or is available to anyone other than the original and first owner(s). It is the responsibility of the owner(s) to maintain such identification records for purposes of exercising the rights under this base metal warranty throughout the duration of the base metal warranty period. All claims must be submitted in writing to Englert within the base metal warranty period and within thirty (30) days after discovery of the claimed defect. Failure to timely submit a claim is a breach of the Warranty and no coverage under this Warranty will be afforded for the claim. The claim must describe the defect and refer to this base metal warranty number and the date of issuance, and to include the name of the contractor and invoice of the purchase. Englert will then examine the Product or cause it to be examined. If, after inspection, it is determined by Englert that the claim is valid in accordance with the terms of the base metal Warranty, Englert agrees, at its option, to repair or replace the defective Product. Englert will assume 1001% of the cost of repairing or replacing Product for either 25-years, 30-years, or 35-years for prepainted aluminum, a 25-year metal limited warranty for prepainted Galvalume AZ55 and AZ50 with a 30-year limited warranty on the PernaColor 2000 paint colors, a 35-year limited warranty on PermaColor 3500 ULTRA -Cool@ low gloss paint colors, a 30-year limited warranty on PermaMetallic 2000 paint colors, and a 35-year limited warranty on PermaMetallir- 3500 ULTRA -Cooly low gloss paint colors. A metal limited warranty of 25-years is given for Mill Finish Galvalume AZ55 and 20-years for Mill Finish Galvalume AZ50. The above is outlined in Section IV: A. B. C. and D. above. The basis of computing cost of repairing or replacing Product shall be the current market price. Englert has sole discretion as to whether the Product shall be the current market price. Englert has sole discretion as to whether the Product is to be repaired or replaced. If Englert determines that repairing is the most appropriate measure to be taken, the owner(s) shall extend a license to Englert or to any of its authorized representatives or contractors to proceed with uninterrupted work for such repairing of Product. The owner(s) shall indemnify and hold Englert or any of its agents, authorized representatives, or contractors, harmless from any damages or claims arising out of or connected with such repair, provided however, that such indemnification shall not extend to ads of negligence by Englert, its agents, employees authorized representatives or contractors. Repaired or replaced Product shall be warranted for the unexpired term of the original base metal warranty. The term "replacement' shall mean and is limited to Englert furnishing replacement Product only F.O.B., Perth Amboy, New Jersey. The term "replacement" does not include labor costs of Product removal, fabrication, or installation. This base metal warranty does not confer upon the owner(s) the right to refinish, restore, repair, or replace product without a written authorization executed by a duly authorized officer of Englert. Any restoration, refinishing, repairing, or replacement of Product not authorized in writing by a duly authorized officer of Englert shall result in this warranty becoming null and void. Inconsistencies, such as waviness or oil canning, of the flat/planer surfaces of Englert's Product are not a defect and are expressly excluded from this base metal warranty, as this is considered an inherent characteristic of the Product when roll -formed. On Mill Finish Galvalume, both passivated and acrylic coaled, uniform visual appearance is not guaranteed. If uniform visual appearance is necessary or desired then a prepainted product should be purchased. General Terms of All Warranties. Contained Within This Certificate A. The purchased product warranties contained in this certificate are given in lieu of any and all warranties, expressed or implied, including any implied warranty or merchantability or fitness for any particular purpose or any statutory warranty, and is not valid unless issued by Englert, duly signed by an authorized officer of Englert for the Product on a speck project, identifying its name and location and proof of purchase of the Product from Englert. The warranty certificate must be completed and submitted to Englert. The provisions hereof shag constitute the owner's exclusive remedy for breach of warranty, given under this certificate. Englert shall not be liable to the owner(s) for incidental, special or consequential damages for breach of any written or implied warranty on the Product or its application and under no circumstances shall Englert be responsible for any consequential damages or loss to the building, its contents or other material. B. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary, from state to state. In the event that any provisions of this Warranty are found to be invalid or unenforceable by a court of competent jurisdiction, all other provisions shall remain in full force and effect. C. This certificate covers any and all agreements under this Warranty, either expressed or implied, and shall not be modified or extended, except in writing by an authorized officer of Englert. D. Failure to apply for any of the warranties herein within thirty (30) days of substantial completion of the component of the building of which the Product is a part shall result in all warrantyAvarranties becoming null and void. E. The parties agree that the warranties in this certificate shall be governed by, construed, and enforced in accordance with the laws of the State of New Jersey. Legal action to construe or enforce any of the warranties in this certificate shall be brought in a Court of competent jurisdiction in Perth Amboy, NJ, USA. The owner(s) expressly agree to submit to the jurisdiction and laws of the courts as set forth above. F. No waiver of any provision or condition of this Warranty by Englert, through the course of performance, action, or otherwise, shall be construed by the owners(s) to be a waiver of any other provision or condition of the Warranty. G. In the event of litigation arising under, related to or in connection with this Warranty, the prevailing party shall be entitled to recover reasonable attorney's fees and costs from the non -prevailing party, at the pre-trial, trial and appellate levels. ENGLERT- No. Customer Name: ' Architect: Customer Address: City/State/Zip Code: Telephone No.: Order Date: Invoice Number(s): Material Lot Numbers: Building Owner(s) Owner Location: By Title General Contractor: Project Name: Project Location: Project Completion Date: Panel Profile: Project Size in Sq.Ft. Components: Within % mile from water Distance: End Use — SIC Code (church, school, etc.) New Roofing Re -Roof Contracting Method: Photos Required: on this yards J.A. TAYLOR ROOFING WORKMANSHIP WARRANTY Owner: Project: Location: Installation: A d Date of C omplSoxt Len`ath of Warranty: front date of completion J.A. Tavlor Roofing, Inc. hereby- gives to the Oivner those warranties against defective Nvorkmanship required by the Contract agreement and contract documents. Warrant' period to commence upon date of project completion. Should any defect develop during the ivarranty period as defined above, due to improper workmanship, the same shall, upon Ncritten notice, be made good by this contractor without expense to the Owner. What Is Not Covered This -warranty does not cover any problems with defective materials caused by conditions or handlirl`, beyond our control Spiic ere ttlples of Wnditions u)t c(tled >, tlu i rxant include: 3.,# = xa1. :'1CI, l)I+470d. Sl1C}] as }lu lCdllt5, ,'t l St01111 : illa( eS, Sr jTll 11r 111 'ind5 lit 1 CZS Qf t}1C IllaXIMUnl w, r `Z Nvind to stated oh y`Our conitaCt docun'i it argffor tl ie'niandactLirers \v lit} for your roofin material. er Foo raffia n v it roa r dan a t i sed b't obl is ( such as tree brandies llnl on our roof. 3. Damage~ isoration caused>bv pfes,unez,learti or other c, tamluafcs t, 4. Dama ae caused by settlement, movement or detects in the building. -,Halls or 116 11 afion. Damage caused by alterations made after corpletIoil of application. including structural changes. equipment installation. parntillg. or the application of cleaning solulions. coatln2S. or other modifications. KYLE WHITE. VICE PRESIDIAT J. A. TAYLOR ROOFING. INC. 0" Melton Drive Fort Pierce. Florida ,-f98' Phone: ( 1 1406--10-f0 Fax: (7 7 l-16)i-h 1 / REPAIRS. RE -ROOFS. NEW CONINIERCI.`,L & RESIDENTIAL ROOFING CONTRACTORS SERVING FLORIDASINCE Igor I. ICENSE #C'CC1325720