HomeMy WebLinkAboutENERGY EFFICIENCY CODEF` RM 1100A-08
F ORIDA ENERGY EFFIC'12ENC CODE FOR BUILDING CONSTRUCTION
, , Florida Department of Community Affairs Residential Performance Method A
Project
Stiet:
Name: HOMEOWNER RICK WOODIN Builder Name: JOMEOWNER
LOT 5 OAK DR Permit Office:
ILE COPY
City,
State, Zip: FORT PIERCE, FL f �fa�y �a�p Permit Number:
0.s5��o9 <!
O
Iper: RICK WOODIN Jurisdiction:
Design
Location:. FL, Fort Pierce
I
1.
construction or existing New (From Plans)
9. Wall Types Insulation Area
2. Single�elw
family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=5.0 1197.30 ft2
I
Lmber 1
b. Frame - Wood, Adjacent R=11.0 149.33 ft2
3. <
of units, if multiple family
c. N/A R= ft2
4. Number
of Bedrooms 3
d. N/A R= ft2
5. Is
this a worst case? No
10. Ceiling Types Insulation Area
6. ai
nditioned floor area (ft?) 1600
a. Under Attic (Vented) R=30.0 1600.00 ftZ
-7.
indows Description Area
b. N/A R= ft2
c. N/A R= ft2
al
U-Factor: Dbl, U=0.64 182.33 ft2
SHGC: SHGC=0.33
11. Ducts
b
U-Factor: N/A ft2
a. Sup: Attic Ret: Attic AH: Garage Sup. R= 6, 320 ft 2
SHGC:
12. Cooling systems
c
U-Factor: N/A ft2
a. Central Unit Cap: 35 kBtu/hr
SHGC:
SEER: 14
d:
U-Factor: N/A ft2
13. Heating systems
11
SHGC:
a. Electric Heat Pump Cap: 36 kBtu/hr
e:
U-Factor: N/A ft2
HSPF:8.5
SHGC:
14. Hot water systems
$.,• ,loor
Types Insulation Area
a. Electric Cap: 40 gallons
a�
Slab -On -Grade Edge Insulation R=0.0 1600.00 ft2
1 EF: 0.92
N/A R= ft2
ft2
b. Conservation features
N/A R=
None
15. Credits Pstat
Glass/Floor
Total As -Built Modified Loads: 28.67
Area: 0.114 PASS
Total Baseline Loads: 33.90
I Jreby
certify that the plans and specifications covered by
Review of the plans and VE SN,
�0�,
thi�l
Code.
calculation are in compliance with the Florida Energy
specifications covered by this ti0�� _ ,
calculation indicates compliance via,,rf` ��,��
PREPAR
with the Florida Energy Code.
Before construction is completed
DATE:
this building will be inspected for O _'�,1,-��11,`Cti
compliance with Section 553.908 *z
I h�
reby certify that this building, as designed, is in compliance
Florida Statutes. CO
wit
the Florida Energy Code.
D WE
O�I
NER/A�GENT:
BUILDING OFFICIAL:
DIF�TE:
�/—m�'
DATE:
- °� ompliance requires certification by the air handler unit manufacturer that the air handler enclosure
ualifies as certified factory -sealed in accordance with N1110.A.3.
il
EnergyGauge® USA - FlaRes2008 Page 1 of 5
PROJECT
Title:
HOMEOWNER RICK WOODI Bedrooms: 3
Adress Type:
Street Address
Bd
ilding Type:
FLAsBuilt
Bathrooms: 2
Lot #
5
Omer:
RICK WOODIN
Conditioned Area: 1600
SubDivision:
#
¢f Units:
1
Total Stories: 1
PlatBook:
B
ilder Name:
JOMEOWNER
Worst Case: No
Street:
LOT 5 OAK DR
P
emit Office:
Rotate Angle: 0
County:
St. lucie
Ju
"111
Iisdiction:
Cross Ventilation:
City, State, Zip:
FORT PIERCE,
Fil
NIW/Existing:
ily Type:
Single-family
New Plans)
Whole House Fan:
FL,
Comment:
(From
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
VI
Design
Location TMY Site Zone 97.5 %
2.5 % Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39
I
90 75 70 722
62 Low
FLOORS
i #
Floor Type
Perimeter R-Value
Area
Tile Wood Carpet
1
I'I
Slab -On -Grade Edge Insulatio
169.8 ft 0
1600 ft2
0 0 1
d
ROOF
f iil
Roof Gable
Roof Solar Deck
III #
Type Materials Area Area
Color Absor. Tested Insul.
Pitch
1
I I
Hip Composition shingles 1789 ft2 0 ft2 Medium 0.96 No 0
26.6 deg
ATTIC
rJ #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
I
1
I
Partial cathedral cei
Vented 300
1600 ft2 N N
CEILING
#
Ceiling Type
R-Value
Area Framing Frac
Truss Type
1
d
Under Attic (Vented)
30
1600 ft2 0.11
Wood
1
WALLS
Cavity Sheathing
Framing Solar
#
Ornt Adjacent To
Wall Type
R-Value Area R-Value
Fraction Absor.
1
NE Exterior
Concrete Block - Int Insul
5 381.33 ft2
0 0.75
2
SE Exterior
Concrete Block - Int Insul
5 296 ft2
0 0.75
3
NW Exterior
Concrete Block - Int Insul
5 298.67 ft2
0 0.75
4
SW Exterior
Concrete Block - Int Insul
5 221.33 ft2
0 0.75
I'I
`l
5
SW Garage
Frame - Wood
11 149.33 ft2
0.23 0.01
/27/2009 11:14 AM EnergyGauge® USA - FlaRes2008
Page 2 of 5
DOORS
it
# Ornt Door Type
Storms
U-Value
Area
1 SW Wood
None
0.46
20 ft2
61
2 SW Wood
None
0.46
20 ft2
f
WINDOWS
Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above.
Overhang
V
# Ornt Frame Panes
NFRC
U-Factor SHGC Storms Area
Depth Separation
Int Shade
Screening
1 NE Metal Low-E Double
Yes
0.64 0.33 N 20 ft2
1 ft 4 in 0 ft 8 in
HERS 2006
None
2 NE Metal Low-E Double
Yes
0.64 0.33 N 53.33 ft2 1 ft 4 in 0 ft 8 in
HERS 2006
None
3 NE Metal Low-E Double
Yes
0.64 0.33 N 40 ft2
1 ft 4 in 0 ft 8 in
HERS 2006
None
4 SE Metal Low-E Double
Yes
0.64 0.33 N 18 ft2
1 ft 4 in 1 ft 0 in
HERS 2006
None
5 NW Metal Low-E Double
Yes
0.64 0.33 N 6 ft2
1 ft 4 in 1 ft 2 in
HERS 2006
None
i
LI
6 SW Metal Low-E Double
Yes
0.64 0.33 N 45 ft2
1 ft 4 in 1 ft 0 in
HERS 2006
None
INFILTRATION & VENTING
---- Forced Ventilation ----
Run Time
Fan
Method SLA
CFM 50
ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction
Watts
�I
Default 0.00036
1511
7.08 82.9 156.0
0 cfm 0 cfm
0
0
GARAGE
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 420 ft2
420 ft2
62 ft
8 ft
1
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity Air Flow
SHR
Ductless
r
it
1 Central Unit
None
SEER: 14
35 kBtu/hr 1050 cfm 0.75
False
I
HEATING SYSTEM
I
# System Type
Subtype
Efficiency
Capacity Ductless
—�i
1 Electric Heat Pump
None
HSPF: 8.5
36 kBtu/hr False
HOT WATER SYSTEM
,
#. System Type
EF Cap Use
SetPnt
Conservation
LI
1 Electric
0.92 40 gal 60 gal
120 deg
None
SOLAR HOT WATER SYSTEM
Collector
e
Storage
g
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
I III
None None
ft2
. k
11:14 AM EnergyGauge® USA - FlaRes2008 Page 3 of 5
DUCTS
--- Supply I
----
---- Return
----
Air
Percent
# Location R-Value Area
Location
Area
Leakage Type
Handler
CFM 25
Leakage
QN
RLF
1 Attic 6
I
320 ft2
Attic
80 ft'
Default Leakage
Garage
I
TEMPERATURES
Pr,.'gramable
Thermostat: Y
Ceiling Fans:
Col
fling [[XX]] Jan [[X] Feb
[[XX]] Mar
[[XX]]
Apr [[X]
May
Jun X] Jul
Aug
Sep
Oct
Xj Nov
[[XX]] Dec
Heatingg
[X] Jan [X] Feb
[X] Mar
[X]
Appr [X]
May
Jun Jul
�X Aug
Sep
Oct
Nov
[X] Dec
Ve'
tin [[XX]] Jan [[XX]] Feb
[[XX]] Mar
[[XX]]
Apr [[XX]]
May
lX]
[ Jun [X] Jul
l
XX]] Aug
L
[X]
Se [X]
p l
lX]
Oct [X]
Nov
[[XX]] Dec
The ostat Schedule: HERS 2006 Reference
Hours
Sch tlule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling
(WD) AM
I PM
78
80
78
80
78
78
78
78
78 78
78 78
78
78
78
78
80
78
80
78
80
78
80
78
Coo
ing (WEH) AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Hea
ing (WD) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
ling
68
68
68
68
68 68
68
68
68
68
66
66
Hea
(WEH) AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
11:14 AM EnergyGauge® USA - FlaRes2008 , Page 4 of 5
FORM 1100A-08
Code Compliance Cheklist
Residential Whole Building Performance Method A = Details
ADDRESS: LOT 5 OAK DR PERMIT #:
FORT PIERCE, FL,
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior
Windows & Doors
N1106.AB.1.1
Maximum:.3 cfm/s .ft. window area; .5. cfm/s .ft. door area.
11
Exterior
& Adjacent Walls
N1106.AB.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors &
j
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at corners; utility penetrations;
j
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls'where a continuous infiltration barrier is
Installed that extends from, and is sealed to, the foundation to the
top plate.
loors
N1106.AB.1.2.2
Penetrations/openings > 1/8" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
q
is installed that is sealed to the perimeter, penetrations and seams.
eilings
N1106.AB.1.2.3
Between walls & ceilings; penetrations of ceiling plane to top floor;
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier; gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1/2" clearance & 3" from
j
insulation; or Type IC with < 2.0 cfm from conditioned space,
tested.
�Multi-story Houses
N1106.AB.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
Iheaters
comply with NFPA, have combustion air..
OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N112.ABC.3. Switch
or clearly marked circuit breaker (electric) or cutoff (gas) must be
provided. External or built-in heat trap required.
wimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
i
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
it Distribution Systems
N1110.AB
Ail. ducts, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N1107.AB.2
Separate readily accessible manual or automatic thermostat for
each s stem.
Insulation
N1104.AB.1
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.B.1.1
sides. Common ceiling & floors R-11.
I
27/2009 11:14 AM
EnergyGauge® USA - RaRes2008
Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 85
The lower the EnergyPerformance Index, the more efficient the home.
1. N
w construction or existing New (From Plans) 9. Wall Types Insulation Area
2. Sr
ih a. Concrete Block - Int Insul, Exterior R=5.0 1197.30 ft2
gle family or multiple family Single-family
I b. Frame -Wood, Adjacent R=11.0 149.33 ft2
3. N
mber of units, if multiple family 1 c. N/A R= ft2
4. Nimber
of Bedrooms 3. d. N/A R= ft2
5. Is
his a worst case? No 10. Ceiling Types Insulation Area
6. C
nditioned floor area (ft2) 1600 a. Under Attic (Vented) R=30.0 1600.00 ft2
b. N/A R= ft2
7. V NI11Jndows—
Description Area c. N/A R= ft2
U-Factor: Dbl, U=0.64 182.33 ft2
a.
SHGC: SHGC=0.33 11. Ducts
b
U-Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Garage Sup. R= 6, 320 ft2
SHGC: 12. Cooling systems
c.
U-Factor: N/A ft2 a: Central Unit Cap: 35 kBtu/hr
SHGC: SEER: 14
d.'
U-Factor: N/A ft2 13. Heating systems
SHGC: a. Electric Heat Pump Cap: 36 kBtu/hr
e!
U-Factor: N/A ft2 HSPF:8.5
SHGC:
14: Hot water systems
8. Floor
Types Insulation Area a. Electric Cap: 40 gallons
. a.
iSlab-On-Grade Edge Insulation R=0.0 1600.00 ft2 EF: 0.92
b,
l /A R= ft2 b. Conservation features
C.
/A R= ft2 None
15. Credits Pstat
I certiy that this home has complied with the Florida Energy Efficiency Code for Building
Cons uction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
11
base( on installed Code compliant features.
`p Build( r Signature: ate:
?°Addr s of New Home: 1,01��` e✓a� /city/FL Zip: 3 y9s'p
O�TP[E STA��
,t
cOD WE
ote: The home's estimated Energy Performance Index is only available through the EnergyGauge USA -
IaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home
ay qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at
21) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified
aters. For information about Florida's Energy Efficiency Code for Building Construction, contact the
epartment of Community Affairs at (850) 487-1824.
-abel required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G
the Florida Building Code, Residential, if not DEFAULT.
EnergyGauge® USA - FlaRes2008