Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEF` RM 1100A-08 F ORIDA ENERGY EFFIC'12ENC CODE FOR BUILDING CONSTRUCTION , , Florida Department of Community Affairs Residential Performance Method A Project Stiet: Name: HOMEOWNER RICK WOODIN Builder Name: JOMEOWNER LOT 5 OAK DR Permit Office: ILE COPY City, State, Zip: FORT PIERCE, FL f �fa�y �a�p Permit Number: 0.s5��o9 <! O Iper: RICK WOODIN Jurisdiction: Design Location:. FL, Fort Pierce I 1. construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single�elw family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=5.0 1197.30 ft2 I Lmber 1 b. Frame - Wood, Adjacent R=11.0 149.33 ft2 3. < of units, if multiple family c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. ai nditioned floor area (ft?) 1600 a. Under Attic (Vented) R=30.0 1600.00 ftZ -7. indows Description Area b. N/A R= ft2 c. N/A R= ft2 al U-Factor: Dbl, U=0.64 182.33 ft2 SHGC: SHGC=0.33 11. Ducts b U-Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Garage Sup. R= 6, 320 ft 2 SHGC: 12. Cooling systems c U-Factor: N/A ft2 a. Central Unit Cap: 35 kBtu/hr SHGC: SEER: 14 d: U-Factor: N/A ft2 13. Heating systems 11 SHGC: a. Electric Heat Pump Cap: 36 kBtu/hr e: U-Factor: N/A ft2 HSPF:8.5 SHGC: 14. Hot water systems $.,• ,loor Types Insulation Area a. Electric Cap: 40 gallons a� Slab -On -Grade Edge Insulation R=0.0 1600.00 ft2 1 EF: 0.92 N/A R= ft2 ft2 b. Conservation features N/A R= None 15. Credits Pstat Glass/Floor Total As -Built Modified Loads: 28.67 Area: 0.114 PASS Total Baseline Loads: 33.90 I Jreby certify that the plans and specifications covered by Review of the plans and VE SN, �0�, thi�l Code. calculation are in compliance with the Florida Energy specifications covered by this ti0�� _ , calculation indicates compliance via,,rf` ��,�� PREPAR with the Florida Energy Code. Before construction is completed DATE: this building will be inspected for O _'�,1,-��11,`Cti compliance with Section 553.908 *z I h� reby certify that this building, as designed, is in compliance Florida Statutes. CO wit the Florida Energy Code. D WE O�I NER/A�GENT: BUILDING OFFICIAL: DIF�TE: �/—m�' DATE: - °� ompliance requires certification by the air handler unit manufacturer that the air handler enclosure ualifies as certified factory -sealed in accordance with N1110.A.3. il EnergyGauge® USA - FlaRes2008 Page 1 of 5 PROJECT Title: HOMEOWNER RICK WOODI Bedrooms: 3 Adress Type: Street Address Bd ilding Type: FLAsBuilt Bathrooms: 2 Lot # 5 Omer: RICK WOODIN Conditioned Area: 1600 SubDivision: # ¢f Units: 1 Total Stories: 1 PlatBook: B ilder Name: JOMEOWNER Worst Case: No Street: LOT 5 OAK DR P emit Office: Rotate Angle: 0 County: St. lucie Ju "111 Iisdiction: Cross Ventilation: City, State, Zip: FORT PIERCE, Fil NIW/Existing: ily Type: Single-family New Plans) Whole House Fan: FL, Comment: (From CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp VI Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 I 90 75 70 722 62 Low FLOORS i # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 I'I Slab -On -Grade Edge Insulatio 169.8 ft 0 1600 ft2 0 0 1 d ROOF f iil Roof Gable Roof Solar Deck III # Type Materials Area Area Color Absor. Tested Insul. Pitch 1 I I Hip Composition shingles 1789 ft2 0 ft2 Medium 0.96 No 0 26.6 deg ATTIC rJ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC I 1 I Partial cathedral cei Vented 300 1600 ft2 N N CEILING # Ceiling Type R-Value Area Framing Frac Truss Type 1 d Under Attic (Vented) 30 1600 ft2 0.11 Wood 1 WALLS Cavity Sheathing Framing Solar # Ornt Adjacent To Wall Type R-Value Area R-Value Fraction Absor. 1 NE Exterior Concrete Block - Int Insul 5 381.33 ft2 0 0.75 2 SE Exterior Concrete Block - Int Insul 5 296 ft2 0 0.75 3 NW Exterior Concrete Block - Int Insul 5 298.67 ft2 0 0.75 4 SW Exterior Concrete Block - Int Insul 5 221.33 ft2 0 0.75 I'I `l 5 SW Garage Frame - Wood 11 149.33 ft2 0.23 0.01 /27/2009 11:14 AM EnergyGauge® USA - FlaRes2008 Page 2 of 5 DOORS it # Ornt Door Type Storms U-Value Area 1 SW Wood None 0.46 20 ft2 61 2 SW Wood None 0.46 20 ft2 f WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Overhang V # Ornt Frame Panes NFRC U-Factor SHGC Storms Area Depth Separation Int Shade Screening 1 NE Metal Low-E Double Yes 0.64 0.33 N 20 ft2 1 ft 4 in 0 ft 8 in HERS 2006 None 2 NE Metal Low-E Double Yes 0.64 0.33 N 53.33 ft2 1 ft 4 in 0 ft 8 in HERS 2006 None 3 NE Metal Low-E Double Yes 0.64 0.33 N 40 ft2 1 ft 4 in 0 ft 8 in HERS 2006 None 4 SE Metal Low-E Double Yes 0.64 0.33 N 18 ft2 1 ft 4 in 1 ft 0 in HERS 2006 None 5 NW Metal Low-E Double Yes 0.64 0.33 N 6 ft2 1 ft 4 in 1 ft 2 in HERS 2006 None i LI 6 SW Metal Low-E Double Yes 0.64 0.33 N 45 ft2 1 ft 4 in 1 ft 0 in HERS 2006 None INFILTRATION & VENTING ---- Forced Ventilation ---- Run Time Fan Method SLA CFM 50 ACH 50 ELA EgLA Supply CFM Exhaust CFM Fraction Watts �I Default 0.00036 1511 7.08 82.9 156.0 0 cfm 0 cfm 0 0 GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 62 ft 8 ft 1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless r it 1 Central Unit None SEER: 14 35 kBtu/hr 1050 cfm 0.75 False I HEATING SYSTEM I # System Type Subtype Efficiency Capacity Ductless —�i 1 Electric Heat Pump None HSPF: 8.5 36 kBtu/hr False HOT WATER SYSTEM , #. System Type EF Cap Use SetPnt Conservation LI 1 Electric 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM Collector e Storage g Cert # Company Name System Model # Collector Model # Area Volume FEF I III None None ft2 . k 11:14 AM EnergyGauge® USA - FlaRes2008 Page 3 of 5 DUCTS --- Supply I ---- ---- Return ---- Air Percent # Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage QN RLF 1 Attic 6 I 320 ft2 Attic 80 ft' Default Leakage Garage I TEMPERATURES Pr,.'gramable Thermostat: Y Ceiling Fans: Col fling [[XX]] Jan [[X] Feb [[XX]] Mar [[XX]] Apr [[X] May Jun X] Jul Aug Sep Oct Xj Nov [[XX]] Dec Heatingg [X] Jan [X] Feb [X] Mar [X] Appr [X] May Jun Jul �X Aug Sep Oct Nov [X] Dec Ve' tin [[XX]] Jan [[XX]] Feb [[XX]] Mar [[XX]] Apr [[XX]] May lX] [ Jun [X] Jul l XX]] Aug L [X] Se [X] p l lX] Oct [X] Nov [[XX]] Dec The ostat Schedule: HERS 2006 Reference Hours Sch tlule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM I PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Coo ing (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Hea ing (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM ling 68 68 68 68 68 68 68 68 68 68 66 66 Hea (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11:14 AM EnergyGauge® USA - FlaRes2008 , Page 4 of 5 FORM 1100A-08 Code Compliance Cheklist Residential Whole Building Performance Method A = Details ADDRESS: LOT 5 OAK DR PERMIT #: FORT PIERCE, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5. cfm/s .ft. door area. 11 Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & j frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; j between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls'where a continuous infiltration barrier is Installed that extends from, and is sealed to, the foundation to the top plate. loors N1106.AB.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier q is installed that is sealed to the perimeter, penetrations and seams. eilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from j insulation; or Type IC with < 2.0 cfm from conditioned space, tested. �Multi-story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space Iheaters comply with NFPA, have combustion air.. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. wimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool i heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. it Distribution Systems N1110.AB Ail. ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each s stem. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.B.1.1 sides. Common ceiling & floors R-11. I 27/2009 11:14 AM EnergyGauge® USA - RaRes2008 Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 85 The lower the EnergyPerformance Index, the more efficient the home. 1. N w construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Sr ih a. Concrete Block - Int Insul, Exterior R=5.0 1197.30 ft2 gle family or multiple family Single-family I b. Frame -Wood, Adjacent R=11.0 149.33 ft2 3. N mber of units, if multiple family 1 c. N/A R= ft2 4. Nimber of Bedrooms 3. d. N/A R= ft2 5. Is his a worst case? No 10. Ceiling Types Insulation Area 6. C nditioned floor area (ft2) 1600 a. Under Attic (Vented) R=30.0 1600.00 ft2 b. N/A R= ft2 7. V NI11Jndows— Description Area c. N/A R= ft2 U-Factor: Dbl, U=0.64 182.33 ft2 a. SHGC: SHGC=0.33 11. Ducts b U-Factor: N/A ft2 a. Sup: Attic Ret: Attic AH: Garage Sup. R= 6, 320 ft2 SHGC: 12. Cooling systems c. U-Factor: N/A ft2 a: Central Unit Cap: 35 kBtu/hr SHGC: SEER: 14 d.' U-Factor: N/A ft2 13. Heating systems SHGC: a. Electric Heat Pump Cap: 36 kBtu/hr e! U-Factor: N/A ft2 HSPF:8.5 SHGC: 14: Hot water systems 8. Floor Types Insulation Area a. Electric Cap: 40 gallons . a. iSlab-On-Grade Edge Insulation R=0.0 1600.00 ft2 EF: 0.92 b, l /A R= ft2 b. Conservation features C. /A R= ft2 None 15. Credits Pstat I certiy that this home has complied with the Florida Energy Efficiency Code for Building Cons uction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed 11 base( on installed Code compliant features. `p Build( r Signature: ate: ?°Addr s of New Home: 1,01��` e✓a� /city/FL Zip: 3 y9s'p O�TP[E STA�� ,t cOD WE ote: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - IaRes2008 computer program. This is not a Building Energy Rating. If your Index is below 100, your home ay qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 21) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified aters. For information about Florida's Energy Efficiency Code for Building Construction, contact the epartment of Community Affairs at (850) 487-1824. -abel required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G the Florida Building Code, Residential, if not DEFAULT. EnergyGauge® USA - FlaRes2008