HomeMy WebLinkAboutREVIEW-COMMENTSCode Compliance Division Review Comments
2300 Virginia Avenue SCANNED
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578 BY
http://www.stlucieco.org/public_works/permittinga�tm Lucia C��linoy
PROPERTY INFORMATION
Address: OAK DR
City / State / Zip: FORT PIERCE FL 34949
Parcel # : 1436-601-0054-000/0 Jurisdiction: St. Lucie County
Zoning: RS-4 Lot # : 5 Block: 3
APPLICATION INFORMATION
Permit Number: 0904-0182
Activity Type: New
Permit Type: Building Residential (SFR)
tractor Name: RICHARD A. NEWLAND
iness Name: NEWLAND CONTRACTING INC
iness Addr: 8004 GEORGES RD
I State I Zil FT PIERCE, FL 34951
Page 1
Owner(s):
RICHARD K WOODIN
Application Type: Master Permit w/subs
Other Activity:
Stories: 1 Automatic Sprinkler System?
Fax Number 772-464-8652
iew Type Status Reviewed By
uments Missing Pending Lorie Gerstemeier
5/2009 1 Comment need recorded noc
5/2009 2 Comment need 2007 windload sheets
3 Comment NEED PLUMBING SUB
Date Started Date Complete Date Released
4 Comment NEED TO BRING IN WITH PICK UP A COPY OF THE VEGETATION REMOVAL PERMIT
Review Pending
Amy Mott
Review Complete Lorie Gerstemeier 04/15/2009 04/15/2009
,5 174 \
Code Compliance Division
2300 Virginia Avenue
Ft. Pierce, FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
hftp://www.stiucleco.org/public—works/pormitting.htm
Supervisor Review Complete
Review Comments
Frank Williams
04/15/2009
Page 2
Zoning Review Incomplete Lydia Galbraith 04/15/2009
04/16/2009 1 Comment YOU NEED TO PROVIDE A PLUMBING SUB AGREEMENT
04/16/2009 2 Comment YOU NEED TO PROVIDE A WIND LOAD FORM WITH THE 2007
BUILDING CODE WITH 2O09 REVISIONS.
04/16/2009 3 Comment THE CONCRETE SIDE WALK AND REAR PATIO IS NOT SHOWING ON THE SURVEY
04/16/2009 4 Comment IT IS NOT CLEAR WHAT TYPE OF DRIVEWAY THE PROPOSED DRIVE WAY IS.
PLEASE PROVIDE THE INFORMATION ON THE SURVEY.
04/16/2009 5 Comment THE SURVEY AND THE FLOOR PLAN ARE NOT MATCHING. THE ENTRANCE ON THE SURVEY
HAS DIFFERENT DIMENSIONS THAN THE FLOOR PLAN.
EVERYTHING NEEDS TO MATCH.
WE NEED CORRECTED SURVEYS OR CORRECTED BUILDING PLANS.
04/16/2009 6 Comment THE SURVEY IS MISSING THE ACTUAL FRONT SETBACK AND REAR SETBACK.
I/17/2009 7 Comment THE SURVEY IS MISSING THE LOCATION OF THE WELL. THE PROPERTY DOESN'T HAVE PUBLIC
WATER, THERE ARE NO PIPES RUNNING THRU THIS STREET.
YOU NEED TO PROVIDE A WELL PERMIT FROM THE HEALTH DEP.
THE SURVEY NEEDS TO SHOW WHERE THE WELL IS AND NOT BEING IN CONFLICT WITH THE
SEPTIC SYSTEM. THE CORRECTED SURVEY NEEDS TO BE STAMPED BY THE HEALTH DEP.
t
St. Lucie County
PUBLIC WORKS DEPARTMENT
CODE COMPLIANCE DIVISION
2300 Virginia Avenue
Fort Pierce, FL 34982
772-462-1553
Design Certification for Wind Load Compliance
This Certification must be completed by the project design architect or engineer. This Certification must be
submitted in duplicate with all applications for building permits involving the construction of new residence
(single or multi- family), residential addition, any accessory structure requiring a building permit, and any
nonresidential structure. This Certification shall not apply to interior renovations (provided that no exterior
structural walls, columns or other components are being affected) and certain other minor building permits. For
further assistance, please contact the Building Inspection Office at (772)462-2172.
Project Nameflce
else
pi)
Street Address
Permit Number
Occupancy Type
Construction Type
Certification Statement:
I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to
comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind
loads and forces specified by current code provisions.
Design Parameters and Assumptions Used: (Please check or complete the appropriate box.)
1 Florida Building Code 20 Edition with 20 Supplements and ASCE 7
2. Building Design is: Enclosed: Partially Enclosed: Open Building:
3. Mean Roof Height: Roof Pitch: Internal Pressure Coefficient:
4. Width of End Zone: Wind Speed: (3 sec. gust)
S. Wind Exposure Classification: Adjustment Factor for Exposure & Height:
6. Components & Cladding Wind Pressure on Roof Zone 1 2 3 PSF
7. Components & Cladding Wind Pressure on Wall Zone 45 PSF
8. Components & Cladding wind Pressure on Overhead Garage Door PSF
10. Shear Walls Considered for Structure? Yes No (if No, attach explanation)
11. Continuous Load Path provided? Yes No (if No, attach explanation)
12. Are Component and Cladding Details Provided? Yes No (if No, attach explanation)
13. Minimum Soil Bearing Pressure: Presumptive: By Test: PSF
As witnessed by my seal, I hereby certify that the information included with this certification is true and
correct, to the best of my knowledge and belief.
Name:
Design Firm:
SLCCDV Form # 020-00
Revised 2/27/09 (CL)
Cert #:
SEAL
I
TRANSMISSION VERIFICATION REPORT
TIME 04/17/2009 16:18
NAME
FAX
TEL
SER.# BROH5J320634
DATE J I ME
FAX NO./NAME
DURATION
PAGE(S)
RESULT
MODE
OF COUNTY
ISSIONERS
04/17 16:17
94648652
00: 00: 57
04
OK
STANDARD
ECM
ST LUCI E COUNTY
(4b4 r 6 2-
PUBLIC WORKS
DEPARTMENT
N
BUILDING & ZONING DIVISION
FAX COVER SHEET
FAX (772) 462-2522 PHONE # ,- (772) 462-1553
7 NO. OF PAGES INCL. COVER:
c-
M 0 0t��
PHONE #f ka-
1 S`j
_Do LA b4 - 8b52,
0
�9?
ST LUCI E COUNTY
BOARD OF COUNTY PUBLIC WORKS
COMMISSIONERS DEPARTMENT
BUILDING & ZONING DIVISION
FAX COVER SHEET
FAX #: (772) 462-2522 PHONE #: (772) 462-1553
I (4 NO. OF PAGES INCL. COVER:
ER:
NTS:
RE: 0ClCLA- ot82
PHONE #. L,ba- I SSS