HomeMy WebLinkAboutENERGY EFFICIENCY CODECANNF-D FOR, I R405-2017 � BY ��, a FL�IRIDA ENERGY E�F1M CY ODE FOR BUILDING CONSTRUCTION F i rida Department of Business and Professional Regulation - Residential Performance Method Projec i Name: Lot 011 F1452 A LHG - E Builder Name: Street Permit Office: St. -Lucie City, SS ate, Zip: Ft. Pierce, FL , Permit Number: Owner Ryan Homes Jurisdiction: 661000 Desig' Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. Newil onstruction or existing New (From Plans) 9. Wall Types (1516.7 sgft.) Insulation Area 2. Singli family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1265.30 ft2 b. Frame - Wood, Adjacent R=11.0 251.33 ft2 3. Numt r of units, if multiple family 1 c. N/A R= ft2 ber 4. Numb of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1452.0 sqft.) Insulation Area 5. Is thi' a worst case? No J a. Under Attic (Vented) R=30.0 1452.00 ft2 6. Con ioned floor area above grade (ftz) 1452 b. N/A R= ft2 Con floor area below grade (ftz) 0 c. N/A R= ft2 11. Ducts R ft2 7. Wind �Ioned ws(132.0 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 290.4 a. U=, actor: Dbl, U=0.54 98.67 ft2 S GC: SHGC=0.31 b. U' actor: Dbl, U=0.31 33.33 ft2 12. Cooling systems kBtu/hr Efficiency S,GC: SHGC=0.31 a. Central Unit 23.2 SEER:14.00 c. U actor: N/A ft2 S, GC: 13. Heating systems kBtu/hr Efficiency d. U actor: N/A ft2 a. Electric Heat Pump 23.2 HSPF:8.20 S H GC: Area 1 leighted Average Overhang Depth: 1.000 ft. Area IiVeighted Average SHGC: 0.310 14. Hot water systems a. Electric Cap: 50 gallons 8. Floorrs ypes (1452.0 sqft.) Insulation Area EF: 0.900 a. SI -On-Grade Edge Insulation R=0.0 1452.00 ft2 b. I Conservation features b. Nh R= ft2 None c. Nh R= ft2 15. Credits Pstat Glass/'� Total Proposed Modified Loads: 49.49 PASS loor Area: 0.091 Total Baseline Loads: 51.13 1 hereby certify that the plans and specifications covered by Review of the plans and iet1 BT,gpA this cal, ulation are in compliance with the Florida Energy specifications covered by this Code. i calculation indicates compliance '•;:�� ���,; O with the Florida Energy Code. tn�,-:.=: PREP' RED BY: Before construction is completed DATE, ► 20 this building will be inspected for O compliance with Section 553.908 hereb certify that this building, as designed, is in compliance Florida Statutes. , 5� COD with th Florida Energy Code. Wse I' OWN AGENTU. a BUILDING OFFICIAL: DATE, DATE'. - ComHance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certif ad factory -sealed in accordance with R403.3.2.1. - Coml lance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelo ie leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Com Hance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested p accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 On for whole house. FILECOPY7/16/218 2:28 PM EnergyGauge® USA Section R405.4.1 Com liant o are a e 1 of 4 P 9 r:YIRflA R nr,-7nl7 INPI IT SI IMMORV r.HFCKLIST REPORT PROJECT Title: Buildin, Owner # of U'ts: Build e Permit Jurisdi, Family iType: New/ElIsting: Comm' Type: dame: jName: Office: Ilion: nt: Lot 011 F1452 A LHG - E Bedrooms: 3 User Conditioned Area: 1452 Ryan Homes Total Stories: 1 1 Worst Case: No Rotate Angle: 0 St. Lucie Cross Ventilation: No 661000 Whole House Fan: No Single family New (From Plans) Address Type: Lot Information Lot # 11 Block/Subdivision: Oakland Lake PlatBook: Street: County: St. Lucie City, State, Zip: Ft. Pierce , FL, CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Numi per Name Area Volume 1 Blocki 1452 12632.4 I SPACES Num er Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1452 12632.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 146 ft 0 1452 ftz ---- 0.29 0 0.71 u ROOF # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Tested Tested Insul. Pitch (deg) 1 Hip Composition shingles 1573 ftz 0 ftz Dark 0.5 N 0.5 No 0 22.6 u ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1452 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1452 ftz 0.1 Wood C I 7/16/20 !B 2:28 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 4 I. FORM R'' 05-2017 INPUT SUMMARY CHECKLIST REPORT I WALLS Adjacent CavR_Vqity Width Height Sheathing Framing Solar Below pace SIn Et Et In Area -Vallle action - or R Fr AhQ G rade% 1 S Exterior Concrete Block - Int Insul Main 4.1 37 6 8 8 325.0 ft2 0 0 0.5 0 2. E Exterior Concrete Block - Int Insul Main 4.1 21 0 8 8 182.0 ft2 0 0 0.5 0 3 I' N Exterior Concrete Block - Int Insul Main 4.1 47 6 8 8 411.7 ft2 0 0 0.5 0 4 j W Exterior Concrete Block - Int Insul Main 4.1 40 0 8 8 346.7 ft2 0 0 0.5 0 5 Garage Frame - Wood Main 11 29 0 8 8 251.3 ft2 0 0.25 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width eightln Area Ft In Ft 1 E Insulated Main None .4 3 6 8 20 ftz 2 Wood Main None .46 2 8 16 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 1 Metal Low-E Double Yes 0.54 0.31 N 16.4 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None E 2 Metal Low-E Double Yes 0.54 0.31 N 16.4 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None N 3 Metal Low-E Double Yes 0.54 0.31 N 16.4 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None W 4 Metal Low-E Double Yes 0.54 0.31 N 49.3 ft2 1 ft 0 in 2 ft 0 in Drapes/blinds None �I 5 W 4 Metal Low-E Double Yes 0.63 0.31 N 33.3 ft2 1 ft 0 in 2 ft 0 in None None IIJ GARAGE l # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 393 ft2 393 ft2 64 ft 8.7 ft 1 INFILTRATION # S`I�pe Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholi Ihouse Proposed ACH(50) .000387 1473.8 80.91 152.16 .2875 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Black Ducts 1 Electric Heat Pump/ Split HSPF:8.2 23.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 14 23.2 kBtu/hr 696 cfm 0.75 1 sys#1 7/16/201 �, 2:28 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 I I FORM� R 105-,2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return I Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 290.4 ft Main 72.6 ft2 Proposed Qn Main --- cfm 72.6 cfm 0.05 0.50 1 1 TEMPERATURES Progra " fable Thermostat: Y Ceiling Fans: CoolingJan Heatin j jFeb [ ]Mar Jan [X] Feb [X] Mar Apr E Apr f May Xj Jun Jul May 4 ] Jun f Jul AugSe f AuE Seep E Oct Oct Nov Nov Dec Dec VentingJan [ ] Feb [X] Mar [X] Apr [ May [ ] Jun [ Jul [ Aug [ Se [X] Oct Nov Dec Thermost t Schedule: HERS 2006 Reference Hours Schedule ype 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ( D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling ( EH) 78 78 78 78 78 78 78 78 1 PM 78 78 78 78 Heating ( D) AM 66 66 66 66 66 68 68 68 68 68 68 68 I� PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating ( EH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 66 68 68 68 68 66 66 MASS M '' s Type Area Thickness Furniture Fraction Space D ault 8 Ibs/s .ft. 0 ft2 O ft 0.3 Main Name: Test Rater Rating Compant: Test Rater Signature: Date: 7/16/201 �12:28 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4 Florida Building Code, Energy Conservation, 6th Edition (2017) ndatory Reauirements for Residential Performance. Prescriptive and ERI Methods ADDRESS: Permit Number: Ft. Pierce , FL , TORY REQUIREMENTS See individual code sections for full details. 1' SECTION R401 GENERAL R4 '1.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL) dis 'May card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Se tion 553.9085, Florida.Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and no resold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components instilled in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans an °specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD. R40 4,J r leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveloTte building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. i R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required u by the code official, an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. I During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or !other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. Interior doors, if installed at the time of the test, shall be open. 5Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. . Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. Fj R402 4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where usingt1e. ght-fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the repl fiWhere using tight -fitting doors an masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907. R402 .3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per squar; foot (1.5 L/s/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or AAM�1./', WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer. Site -built windows, skylights and doors. 7/16/�018 2:28 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402. „ 4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to open c" mbustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or enclos ""d in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements of Tab R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be fully g sketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it passe ithrough conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential. ❑ R402.4 5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage betwee I conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not more thF 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R40� II1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R40 1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls at, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R40111�, 3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. (Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or III(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in 1ccordance with Section R403.3.3. ❑ '(ai 403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ !R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 11 1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the i test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑ R403.3.5 uilding cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.4 M I11chanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C) or below 50F (1 WC) shall be insulated to a minimum of R-3. I ❑ 403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that aused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause gradation of the material. Adhesive tape shall not be permitted. I ❑ 1403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in ccordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. °btomatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 7/16/2018 2:28 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R4 i' 5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have he , traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a do,, ward and upward bend of at least 3 1/2 inches (89 mm) in the hot water distribution line and cold water line located as close as possible to tj6lVf storage tank. R403.5.6 Water heater efficiencies (Mandatory). R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature setting range shall be from 100°F to 140°F (38°C to 60oC). R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of i combustion types of service water -heating systems to be turned off. R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1. R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors, and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar water -heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and 2. Be installed at an orientation within 45 degrees of true south. R40316 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the F'brida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation in6luding: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that cl'I se when the ventilation system is not operating. �403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical entilation system, fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be powered by an electronically commutated motor. 403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation hall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable Indoor Air Quality, shall be the maximum rates allowed for residential applications. i 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3• If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10 otherwise. R403.71'Heating and cooling equipment (Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY F ��N LOCATION AIRFLOW RATE MINIMUM (CFM) MINIMUM EFFICACY a (CFM/WATT) AIRFLOW RATE MAXIMU (CFM) R0ge hoods Any 2.8 cfm/watt Any In line fan Any 2.8 cfm/watt Any B hroom, utility room 10 1.4 cfm/watt <90 B throom, utility room 90 2.8 cfm/watt Any _ I For SI:;(1 cfm = 28.3 Umin. II 7/16/2018 2:28 PM i I When tested in accordance with HVI Standard 916 EnergyGaugeO USA - FBC 6th Edition (2017) Compliant Software Page 3 of 5 MAN Dr'' TORY REQUIREMENTS - (Continued) ❑R4 3.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less tha' lthe calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Sec ion 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the equ pment shall not be less than the calculated latent load. Thee ublished value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's exp' �ded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb ter erature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature. Desioin values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calc6lation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space. i Exceptions: 1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of equipment may be sized in accordance with good design practice. R403,'; .1.2 Heating equipment capacity. ❑ R, 03.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. ❑ R, 3.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. ❑ R 3.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners j�all not be less than the design load calculated in accordance with Section R403.7.1. ❑ R4 I3.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an i' �6rmittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to 12. vent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. A variable capacity system sized for optimum performance during base load periods is utilized. R403 8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403114nd C404 of the IECC—Commercial Provisions in lieu of Section R403. i ❑ R403.9 now melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building, shal include automatic controls capable of shutting off the system when the pavement temperature is above 50oF (10°C), and no pre i itation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C). ❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas shad"I' a in accordance with Sections R403.10.1 through R403.10.5. �I R4'03.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R4 3.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule sh II be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar- and waste -heat -recovery pool heating systems. 3. Where pumps are powered exclusively from on -site renewable generation. ❑ R40 .10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at th', f water surface or a liquid cover or other means proven to reduce heat loss. I Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required. R40 10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal ❑ efficigncy of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool heaths fired by natural or LP gas shall not have continuously burning pilot lights. I'I 7/16/2018 :28 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5 C R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard. ,1 Portable spas (Mandator%he energy consumption of electric -powered portable spas shall be controlled by the ents of APSP-14. SECTION R404 ELEC ICAL POWER AND LIGHTING SYSTEMS ❑ R404. 1`� Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-ecacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps. Exception: Low -voltage lighting. R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights. 7/16/2018 �,1�28 PM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5 201'7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. ew home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. ingle-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Main 3. o. of units (if multiple -family) 3. 1 4. umber of bedrooms 4. 3 13. Cooling system: Capacity 23.2 a) Split system SEER 14.0 5.1 this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. onditioned floor area (sq. ft.) 6. 1452 d) Room unit/PTAC EER e) Other 7. ows, type and area 4;nd U-factor:(weighted average) 7a. 0.563 Solar Heat Gain Coefficient (SHGC) 7b. 0.310 14. Heating system: Capacity 23.2 Area 7c. 132.0 a) Split system heat pump HSPF 8.2 1 b) Single package heat pump HSPF 8. S lights c) Electric resistance COP a U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b, Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE I' f) Other 9. FI r type, insulation level: a)°,Slab-on -grade (R-value) 9a. 0.0 b)'i ood, raised (R-value) 9b. 15. Water heating system c) raised (R-value) 9c. a) Electric resistance EF 0.90 ioncrete, b) Gas fired, natural gas EF 10. W � II type and insulation: c) Gas fired, LPG EF A., exterior: d) Solar system with tank EF 1 ood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. asonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. djacent: g) Other 1. „ ood frame (Insulation R-value) 10131. 11.0 2. asonry (Insulation R-value) 1062. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) rider attic 11 a. 30.0 b) Cross ventilation No b) 'Ingle assembly 11 b. c) Whole house fan No c) bee walls/skylight walls 11c. d) Multizone cooling credit d) ,'14diant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label r°quired by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify at this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving f iatures which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display and will be completed based on installed code compliant features. Builder ignature: fiA`Q .315, Date: Z- 2S'� ` Address' f New Home: 5352- Uov-&y\6 141P (vd - City/FL Zip: Ft. Pierce. FL i ,I 7/16/2018 2:28:2 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 r AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Proj Ict Name: Lot 011 F1452 A LHG - E Builder Name: Stre t: Permit Office: St. Lucie City,'State, Zip: Ft. Pierce , FL, Permit Number: Y Owner: Ryan Homes Jurisdiction: 661000 W Desi n Location: FL, Fort Pierce U III COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General I A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirem nts The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. �s Ceiling/a i The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit y pp g /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. I Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists 'I Rim joists shall include the air barrier. Rim joists shall be insulated. Floors I The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-gara a subfloor decking, or floor framing cavity insulation and cantile red shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space �alls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation h a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, pene i rations Duct shafts, utility penetrations, and flue shafts opening to 1 exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed ligh %ng Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and l inng Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on II installation readily conforms to available space shall extend behind popung and wering. Shower/tub I The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phon box or The air barrier shall be installed behind electrical or communication rior extewalls �I boxes or air -sealed boxes shall be installed. HVAC register b ots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids nkler cover plates and walls or ceilings. a. mi auwmUh, nisNacmoi 7/16/2018 2:29 P l vi wy worms sham oe in accordance wim ine provisions or iCC-400. EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 ` I Project Summary Job: F1452 ALHG — Summary Date: 06/06/2018 0 1 ST01P Entire House Br RI/MC NO M? K`�"KG.`"� One Stop Cooling and Heating 7225 Sa soove Cout, Winter Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www0reStopCoolirig.com Licerse: CAC032444 For: Ryan Homes FL Notes: Weather: Fort Pierce, FL, US Winter Design Conditions le db 42 OF db 68 OF i TD 26 OF Heating Summary e 15406 Btuh 2627 Btuh vent (0 cfm) 0 Btuh ie) ication 0 Btuh 0 Btuh ent load 18032 Btuh Infiltration Simplified quality Average 0 Area Equiv. /4VF (cfm) Heating Co g 11� 124539 63 12639 0.45 0.23 95 48 'Heating Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL;AMANA DISTI... Model GSZ140241 K AHRI re 7995055 Efficiency 8.2 HSPF Heating I put Heating Q,uiput Temperature rise 23200 Btuh @ 47°F 27 OF - Actual ai�flow 773 cIrn Air flow f ctor 0.043 cfm/Btuh Static pressure 0.50 in H2O Capacity balance point = 36 OF Backup: Input = 9 4, Output = 29982 Btuh,100 AFUE Summer Design Conditions Outside db 90 OF Inside db 72 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 68 gr/lb Sensible Cooling Equipment Load Sizing Structure 14816 Btuh 2810 Central vent (0 cfm) BBtuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Equipmenqsensible load 16747 Btuh Latent Cooling Equipment Load Sizing Structure 3035 Btuh Ducts 699 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3734 Btuh Equipment Total Load (Sen+Lat) 20481 Btuh Req. total capacity at 0.75 SHR 1.9 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN; JANITROL;AMANA DISTI... Cond GSZ140241 K Coil ARUF251314A AHRI ref 7995055 Efficiency 11.5 EER,14 SEER Sensible cooling 17400 Btuh Latentcooling 5800 Btuh Total cooling 23200 Btuh Actual airflow 773 cfm Airflowfactor 0.044 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Ad- w °— � Comfort Bulder by Wrigtfsoft 18.0.16 RSL)30040 Lake (OL) l-tspedfizt03\F1452ALHG.rLp Calc=W8 FrortDoorfaces: E 2018-JU-08 23:33:50 Page 1 Right-J® Worksheet ON _vTalp � Entire House One Stop Cooling and Heating 7225 Sa scove Court, Wider Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.00m License: CAC032444 Job: F1452 ALHG Date: 06/06/2018 By- RUMC 1 2 3 4 5 R I m name Ex Io�d well Room height R mdimensions R 'm area Entire House 146.0 ft 8.7 ft d 1452.8 IF DIN 205 ft 8.7 ft heat/cool 11.0 x 95 ft 1045 fF Ty Construction number U-value (BtuW-F) Or HTM (Btuhig Area OF) or perimeter (ft) Load (Btuh) Area (111) or perimeter (ft) load (BWh) Heat I Cool Gross N/M Heat Cool Gross N/P/S Heat Cool 6 11 - -. � - - - - - - - 13A-flocs _4A5 tom _ 13A-4ocs 4A5.2om 11DO 13A-0as - - 4A5;2om-_ - - _-- 13A-4ocs 4A5-2om 4A5-2omd _ _ 12C-0svv 11D0--__-__- 166.30ad - -�---- -- 0.143 _----0540 0.143 0540 0290 0.143 __ --.-0540 0.143 0540 0.630 -- - 0.091 -0.390 - - 0.032 - n -n- a is a s - .._ s- w w w ' - -n _ -- . - 3.72 ._. -14.04 3.72 14.04 10.14 - - 3.72 _ 14.0.4, 3.72 14.04 16.38 -- 237 10.14 - 0.83 - 262 -__ 14.36 2.62 34.14 11.50 ----- 262 -.14.36.._ 2.62 34.14 42.09 - --133 1150 1.70 - --- 413 397 0 -- 1476 . 229 544 229 204 -- 1152 229 1039 235 383 558 231 - 811 235 695 1674 1410 83 0 83 ---0 0 0 0 ----- 6 0 307 0 216 -.--0 0 0 0 -- - 0 --0: - ----16 183 16 20 _ ' - 326 16 348 49 34 146 0 20 - 310 16 0 0 0 6 0 0 0 0 ..--0 - 0. _ 265 0 0 987 688 549 96 0 34 62 0 0 231 0 549 163 0 1410 qq c-D C { --' 252 - 16 1453 236 --16 559 162 1209 314 184 2464 0 0 0 0 6 0. 87 - 0 ' 0. 1453 105 105 177 6 c) AED exoll ion 1006 503 Envelope) 'gain 12697 112371 1803 2469 12 a) Infilti-90 1 b) Room 2709 0 958 0 380 0 135 0 13 Irtilation Intemalgains] Omipants@ 230 Appliances(other 4 920 1700 0 0 0 Subtotal pines116t013) 15406 14816 2183 2604 14 15 Less exdemallload Less transfer I Redistribution Subtotal DurilOads 17% 19% 0 0 0 15406 2627 0 0 0 14816 2813 17% 19% 0 0 0 2183 372 0 0 0 2604 494 i l Total room load Air required ( 18032 773 17629 773 2556 110 3098 136 Of .4C:GApr wr g tso4ft- 2018-Jct-082333:50 A Ccmiort Builder by W righisoft 18.0.16 RSLI30040 Page 1 Lake(OL)\�otSpedficlLot031F1452ALHG.np Calc=WB FrortDoorfaces: E ®N1,'ve I�.�� Right-J® Worksheet Jab: F1452 ALHG Entire House Date: 06/06/2018 One Stop Cooling and Heating By RI/MC 7225Sa Coot, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.00m Licerse: CAC032444 1 2 3 4 5 R m name E sed well R m height R 'mcime .ons R ,fin area GREAT 14.0 ft 8.7 ft heat/cool 1.0 x 298.0 ft 298.0 IF WED 30.0 It 8.7 ft heaV000l 1.0 x 227.0 ft 227.0 ilz Ty Construclion number U-value (BtuMFL-F) Or HTM (BtuhfiF) Area (fF) or perimeter (ft) Load (Bhih) Area (IF) or perimeter (ft) Load (Btuh) Heat I Cool Gross NIPS Heat Cool Gross N/PS Heat Cool 6 11 13A 4as 4A5-2bm 13A-4ocs 4A5-2om 11DO 13A-flocs 4A5-2om 13A-4ocs 4A5-2om 4A5-2omd 12C4?sw 11D0 �166-30ad 0.143 0540 n _n_, a a a ___--- 3.72 14D4 3.72 14.04 10.14 --- - " 262 _t4.36 2.62 34.14 11.50 0 0-0-0-0 0 0 --- U -- ---- U -----0 0 0 0 - - - 131 1.6 - - -- ----- ---0 0 0 0 -- -- -114 ------ 16 114 0 0 ----_ _. 0 ___ 0 227 -- - U --_--- 0 0 0 0 - `-. - -424 __- _229, 424 229 0 _ . _._ - 0 ___.-0 189 .`-: d 0.143 0.540 0.390 0 0 0 0 0 0 --- � 0 0 0 0 � 0 0 0 0 -----_ ---p ,- -._0 233 1116 0 O 0' ____.-0 0 0 0 -----299 ----235 299 558 0 .. _ 0 -._-0 385 - 0.143 0540 0.143 0540 0.630 -' 0.091 0.390 0.032 ss -s- w w w '- _.n_ 3.72 ,1.4.04. 3.72 14.04 16.38 .' 2.37 10.14 0.83 2.62 1.436 2.62 34.14 42.09 ' j 33 1150 1.70 __0 __ - --- - 0 122 33 „- 0 0 298 298 Vy 89 0 0 0 331 459 0 _ _ 0 0 _ 131 16 0 - _ _ 6 0 C F' a; 298 248 505 227 " -227 224 tpm 1.180 - 3068, U.00 14 e- 430 _ 0 6 c) AED excu on 497 Enmelopel ain 1468 2351 2417 1886 12 a) Infiltratio 1 b) Room ntilation 250 0 92 0 557 0 197 0 13 Internal gains: Occupants@ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines to 13) 1727 2443 2974 2543 14 15 Less extemalload Lesstransfer Redistribution Subtotal Duct loads 171% 19 % 0 0 200 1927 329 0 0 325 2768 526 179/6 19°/0 0 0 0 2974 507 0 0 0 2543 483 I Total room load Air required ( ) 229 3P44 34841 148149 30� ACCA to _ � wr gF�tsoR� ComfortBuilder by Wrigttsoft 18.0.16 RSU30040 .4CCA of SpeafiLILot 031F1452 ALHG.np Calc = W8 From Door faces: E JM 2018-JLI-08 23:33:50 Page 2 f Right-M Worksheet ONE STOP Entire House u�l - One Stop Cooling and Heating 7225 Sa l ve Cout, W irier Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOreStopCoolirg.00m Licerse: CAG032444 Jab: F1452 ALHG Date: 06/06/2018 By: RUMC 1 2 3 4 5 R m name Exposed well R m height R�m dimensions Room area Krr 9.0 ft 8.7 ft heat/cool 1.0 x 126.1 ft 126.1 fF PAN 4.0 ft 8.7 ft heat/000l 1.0 x 16.9 ft 16.9 f6 Ty Construction number U-value (BtuWF) Or HTM (BtuW Area (W) or perimeter (ft) Load (BWh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 p_ - 3A-flocs --­ -•--- 1- _4A5;20m---_ _._ 13A-4ocs 4A5-2am 11DO 13A-flocs --- - •--- - .4P&2om - 13A-4ocs 4A5-20m 4_A5-2omd w 12C-0 -- - I1613-30ad _ ',22A:pm -- _ - - -0:149 ----0.540 0.143 0.540 0.390 - - 0.143 _ 0.540 0.143 0.540 0.630 --�.091 0.390 _ 0.032 - 1.180 -n -- n a a a - s - s- w w w ' -- -n_ _ - -3.72 -- _ -14D4 3.72 14.04 10.14 -3.72 _ 14.04 3.72 14.04 16.38 - � - 10.1.4 0.83 30.68 '- -- 262 _----14.36 2.62 34.14 11.50 - - 262 14.36 2.62 34.14 42.09 -� --11.50 1.70 'J -0.00 V 78 -----0 0 0 0_ - -- - -0 __ ___ 0'--0 0 0 0 - - -- 0 0 126 _ _126' - 78 _ -0 0 0 0 � -- - � 0 0 0 - -- 0 -.--0 126 _9 - 291 _-0 0 0 0 -R --0 0 '-- 205 0 35 0 35 0 129 0 "-91 _3 yy_JJ-'.� � -Q 0 0 0 t 0 -------- 0 0 0 0 0 0 0 0 0 0 --0 0 0 0 0 0 0 0 -_---- � 0 - - -- - 0 ___0 0 0 _ 0 - 0 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C F ^ - 0 0 0 -0 - 0 0 -- 0 0 . - 0 --_0. 14 105 276 214 17 17 29 ._v0 _17 4 123 =-=0 -- _` 6 c) AED excu" On -58 -5 Emelopeloss(gain 672 361 266 115 12 a) Infiltratio ,I b) ROOM lotion 167 0 59 0 74 0 26 0 13 Internal gains: I OccupantsCa) 230 Appliancesfother 0 0 1200 0 0 0 Subtotal (lines to 13) 839 1620 340 141 14 15 Less external 1 I Less transfer Redistribution Subtotal Duct loads 17% 19% 0 0 3 842 144 0 0 6 1625 309 171/6 19% 0 0 0 340 58 0 0 0 141 27 Total room load I Air required "m 986 42 1935 85 398 17 168 7 of Manual J _ � wrig_htsoTt� Comfort Builder by W righfsoft 18.0.16 RSLI30040 .4tjCA ...Lake(0L)1 �tSpecifidLot0311`1452ALHG.rp Calc=M18 FrortDoorfaces: E 2018-Jt1-08 2333:50 Page 3 ON ,�� Right-M Worksheet .,,.� .� Entire House One Stop Cooling and Heating 7225 Sa i ve Cout, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.0r eStopCooling.00m License: CAC032444 Job: PI452 ALHG Date: 06/06/201 S By- RI/MC 1 2 3 4 5 Room name wall R Im height R (n dimensions R ,(n area MWIC Oft 8.7 ft heat(cool 8.0 x 7.0 ft 56.0 fF METH 12.Oft 8.7 ft heaYbool 1.0 x 107.5 ft 107.5 fF Ty Construction number U-value (BtuW F) Or HTM (BtuhV) Area (fF) or perimeter (ft) Load (Btuh) Area OF) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/PVS Heat Cool 6 11 --' - '13A-4ois _ _4A5-2om�_-- 13A-4ocs 4A5-2om 11DO 13A 4o`rs - ^ _4A5.2om -- 13A-4ocs 4A5-2om 4A5-2omd _ 12C-0av 111D0 -gT I16B 30ad •- - `- •0 _ 0 0 0 0 -104 0 0 0 0 --_ - 65 108 ---- -- U -,_�._,.0 0 0 0 - 386 -__0 0 0 0 -- 154 0: 89 - - -- --- 0 0, 0 0 0 -273 _----� _0 0 0 0 - - - 87 182 0.143 --0.540 0.143 0.540 0.390 n -,n- a a a _ 9 3.72 `14.04 3.72 14.04 10.14 2 262 14.36 2.62 34.14 11.50 � 0 0 —0 0 0 0 - 0 0 ---0 --__0 0 0 0 '- ' 104 _0 0 0 0 ^-' 65 _ —0 0 0 0 —0 0 0 0 —0 0 0 0_ — 0`143 0-540 0.143 0.540 0.630 s _.s_ w w w 3.72 14D4 3.72 14.04 16.38 2.62 '-1436 2.62 34.14 42.09 0 0 0 0 0 0 0 0 0 - ' -'0 `0 0 0 0 _ 92 0 0 0 0 70 0 0 0 0 165 0 R L-D. C ,F _" _ 0.091 0390 - -n- 237 —1.0.1-4 0.83 .; 36.68 133 .—.11.50 1.70 _OAO _ 70 0 56 =56 0.032 — 1.180 56 47 95 —0-0 108 _ 22A pm 0 , 0 R_— 0 108 _�12 6 c) AED exo r, jon -6 -21 Ernelope lo�)), 211 181 1000 521 12 a) Infiltratiorll b) Room %6 ilation 0 0 0 0 223 0 79 0 13 Internal gains: I Omupants@ 230 Appliancesiother 0 0 0 0 0 0 Subtotal (lines q�to 13) 211 181 1223 600 14 15 Less extemal1 Lesstransfer Redistribution Subtotal Duct loads 17% 19% 0 0 62 273 47 0 0 375 556 106 17% 19. 0 0 0 1223 208 0 0 0 600 114 Total room load I Air required (dm 319 14 661 29 1431 61 714 31 Manual J _ � wr�gF�tsoft� ComfortBuilder by WdghtsoftiS.0.16RSU30040 ACCP....Lake(OL)\L6�tSpecifidLot03tF1452ALHG.np Calc=WB FrortDoorfaces: E 2018-JLJ-08 2333:50 Page 4 ON STOP Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sa ?cove Cout, W irter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwwOneStopCooling.00m License: CAC032444 Jab: F1452 ALHG Date: 06/06/2018 By: RI/MC 1 2 3 4 5 Room name F�1 clwall R m height Robm dimensions R60,marea I O ft 8.7 ft heat/cool 55 x 4.0 ft 22.0 fF BTH2 O ft 8.7 ft heaNcool 55 x 85 ft 46B fF Ty Construction number U-value (Btuh/R -°F) Or HTM (BtuhM Area (fF) or perimeter (ft) Load (Btuh) Area (fF) or perimeter (ft) Load (Btuh) Heat I Cool Gross MPiS Heat Cool Gross N/P/5 Heat Cool 6 11 13A-4ors _4A5-2Dm— 13A-4ocs 4A5-2om 11 DO 13A-4o(s-_— _ 4A$2om _ 13AAocs 4A5-tom 4A5-2omd _1100 1613-30ad 0.143 0540 0.143 0540 0.390 0143 —0.540'--s-_ 0.143 0.540 0.630 0.091 0390 _ 0.032 n -n- a a a T s w w w — -n_ 3.72 . 14D4 3.72 14.04 10.14 3. _ 14D.4 3.72 14.04 16.38 237 .— 1014 083 - 2.62 _ 14.36 2.62 34.14 - 11.50 '1436 2.62 34.14 42.09 133 1150 0 --_--0 0 0 0 - -- -----0 „ _0 0 0 0 - 0 0 0 ------0 0 0 0 ,�__ 0 0 --_ 0 0 0 0 -.R.-- O _`0 0 0 0 - - - 0 0 0 _0 0 0 0 — _ --0 0 0 0 0 0 0, 0 0 0 _ —0--0-0 0 0 0 -- 0 0 0 0 0 - -0-0 1 0 0 0 �1 ILA. 0 0 0 0 0 0: 0 0 0 0 0 0 0 0 22 __0 0 0 0 - 0 0-0-0-0-0 0 0 0_ - 0 0 0 0 C -- 0 0 - 0 __ 1.70 22 18 37 ^ 0 47 47 39 79 0 - 47. _0 - 0 - -- 6 6 c) AED excuion -1 -3 Ermlope lo4lain 18 36 39 77 .12 a) Infiltrati6 i b) Room riitilation 0 0 0 0 0 0 0 0 13 Internal gains. ''I Occupants pa 230 Appliances(lther 0 0 0 0 0 0 Subtotal 0ines'011to 13) 18 36 39 77 14 15 Less extemall ai Lesstransfer 1 Redistribution ! Subtotal Duct loads 17% 19% 0 0 -18 0 0 0 0 -36 0 0 17% 19% 0 0 511 550 94 0 0 400 476 90 Total room load ,I Air required ( I 0 01 0 01 644 28 567 25 of Manual J 8th r ComfortBuilder by W dglUoft 18.0.16 RSU30040 .4CCA ... Lake (OL) ''I t SpecifidLot03tF1452 ALHG.np Calc= W8 Front Door faces: E 2018-Jul-08 2333:50 Page 5 ON;'. STOP Right-M Worksheet Entire House One Stop Cooling and Heating 7225 Sa ve Court, Winter Park, FL 32792 Phore: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com License: CAC032444 Job: F1452 AWG Date: 06/06/2018 By. RI/MC 1 2 3 4 5 Ro11pmname E used wall R m height R m dimensions R '�n area LDRY O ft 8.7 ft heat/cool 35 x 7.0 ft 245 IF BED3 14.0 ft 8.7 ft heatl000l 11.0 x 14.0 ft 154.0 W Ty ', Construction number U-value (Btuh/ft--q Or HTM (Btuh4F) Area (fF) or perimeter (ft) Load (Btuh) oreaperimeter (ft) (BWh) He;7 Cool Gross N/PS Heat Cool Gross N/P)S Heat Cool 6 11 . !';I 13A flans --- - - 4P&2om.__ _ ___� 13A-4ocs 4A5-2om 11DO - 13A4as T 4A5-2om-___ __-- 13A-4ocs 4A5-2om 4A5-2omd I12C:6ii _ - . - 1100 - 1613-30ad z2Prtpm - - Q143 __O-W 0.143 0.540 -.- 0.390 - 0.143 0540 0.143 0.540 0.630 OA91 —2 66 - -235 0 0 0 - - - - 0 0 0 0 _- -p _ 0 261 n -n- a a a S -s- w w w :-n_ 9.72 — 1.4.04 3.72 14.04 10.14 - 372 _ 14.04, 3.72 14.04 16.38 262 14.36-0-0-0-0 0 0 0 0 122 16 105 0 0 0 0 - 392 _229 0 0 0 _ ----- o —;1 0 0 0 -e—' 0 0; 128 2.62 34.14 11.50 ' 262 1.4.36 2.62 34.14 42.09 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 —_____0 0 0 0 0' 0 — 0 0 0 0 0 0 0 — --. 0 - 0 0 0 _ 0 6 0 154 - �_ 0 ---.-0 0 0 0 _ _.� ..— o 0 0 0 0 —0 0 0 0 237 10.14, 0.83 — 1.33 ____11.50 1.70 '- 30 0 30 0 it 0 — 40 ��0 42 C :F _0.390 0.032 --- _1,180 25 25 20 154 s 3068. Oi00 25 0 0-- 0 154 14 930=.0 6 c) AED excu 'Ion -20 _38 Envelope 1 4in 92 62 1179 734 12 a) Infiltrafio I b) Room ve. 'la8on 0 0 0 01 260 0 92 0 13 Internal gains: I Occupants@ 230 Applianoes(other 0 0 500 1 230 0 Subtotal Qines6'�o 13) 92 562 1439 1056 14, 151 less exlemal1 1 Lesstransier Redistribution Subtotal Duct loads 170/6 19% 0 0 -92 0 0 0 0 -562 0 0 17% 19%1 0 0 146 1585 270 0 0 114 1170 222 Total room load l',I Air required (dm) 0 0 0 0 1855 60 1392 61 .oft ComiortBulderbyWrighlsoft18.0.16RSU30040 .Lake (OL),tSpecIfi&ot031F1452ALHG.rLp Calc=W8 FrontDoortaces: E 2018-Jul-08 23:3350 Page 6 ONlr.ji�op Right-J® Worksheet Entire House One Stop Cooling and Heating 7225 Sa smve Coot, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCoolirg.com License: CA0032444 Jab: PI452 ALHG Date: 06/06/2018 By: RI/MC 1 2 3 4 5 R I m name F wall Room height Room dimensions R68m area 11 BED2 37.0 ft 8.7 ft heaU000l 155 x 11.0 It 170.5 fF FOY 55 ft 8.7 ft heaUmol 1.0 x 99.0 ft 99.0 fF Ty Construction number U-value (BWhAF-°F) Or HTM (Btu Area (fF) or perimeter (ft) Load (BUh) Area (fF) or perimeter (ft) Load (Btuh) Heat Cool Gross N/PS Heat Cool Goss NIPS Heat Cool 6 11 13A 4ors _" 4A5r2om 13A-4ors 4A5-tom 11DO 131� - - 4P_.Er.2om,-.- 13A-4ocs 4A5-2om 4A5-2omd 12C-0s6V -- ID0 16B-30ad 0.1, 33 0.540 0.143 0.540 0.390 0.143 _ _ 0540 o'143 0540 0.630 - 0.091 -__-0390 0.032 n -n- a a a ss = -s- w w - w _n_ 3.72 - 14.0-4 3.72 14.04 10.14 v 3 _14.04 3.72 14.04 16.38 10.14 0.83 -- -30.68 - --.2M -_-14.36 2.62 34.14 .. - 11.50 _ 1436 2.62 34.14 42.09 -1-3-3 1150 1.70 - .0.00 -__-_- 0 ---- _ 0 119 0 0 --- M -______0 0 0 0 0 171 ��37'- -- ._______0 441 229 --- 0 _.____-_0 0 0 0 - 0 142 ------ 1f35 - - - W -:-.---0 310 558 0 -- --23y - ----0 0 0 0 - - 0 0 ---- 5 -_____-0 48 0 20 - --0 _.-_ __ 0' 0 0 0 , - 87 _. 16 99 - - _ 99 - 0 _ - 0 28 0 20 -_ 0 0 ---- o 0 --0 0 - 135 16 0 --- 91 ,--- ._0 0 0 0 - --- - 0 0--0--0, 103 0 204 _.__ 6 0 73 0 231 0 0 0 0 0 i 0 0 _ 0 _71, - 16 99 - -- --- - 6 0 0 0 - 16B _ - 162 82 - 169 - - 94 184 168 _ - -- 0- C F- 171 e 17_1, 289 - '- - -0 '22A PM- T I - 1.]-- -^ - - ---- -- 6 c) AED excu I'on 75 -27 Emelopelos dr, 2643 1721 888 723 12 a) Infiltratioi1 b) Room .rfilation 686 0 243 0 102 0 36 0 13 Internal gains: ,I Occupants@ 230 Applianoes/other 1 230 0 0 0 0 Subtotal (lines to 13) 3329 2194 990 759 14 15 Less extemall I Lesstransfer ! Redistribution Subtotal Duct loads 17% 19% 0 0 180 3509 598 0 0 138 2332 443 17% 19% 0 0 -990 0 0 0 0 -759 0 0 ITotal room load it Air required ( 4107 176 2775 122 0 0 0 0 all requirements of Manual J 8th Ed. .4CCP. •'� ^`^^ ComfortBulderbyWdgttsoft18.0.16RSLt30040 Lake (OL) btSpecifidLot03\F1452ALHG.rnp Calc=WB Front Door faces: E 2018-11-08 2333:50 Page 7 Static Pressure and Friction Rate Job: F1452 ALHG Date: 06/06/2018 E STOP Entire House By: RI/MC0GO LINO�ANY NlITING, IOne Stop Cooling and Heating 7225 Sa . ve Cout, Wirter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com Licerse: CAC032444 For: Ryan Homes FL Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressur "flosses II 0 0 H atexchanger 0 0 SOply diffusers 0.03 0.03 R um grilles 0.03 0.03 FiI r 0.10 0.10 Hmidifier 0 0 �ncing damper 0 0 er device 0 0 Available I tic pressure 0.34 0.34 Total• `I Supply Return (ft) (ft) Measured I ngth of run -out 12 0 Measured I' ngth of trunk 12 0 Equivalent I ngth of fittings 110 0 Total length I 134 0 Total effectiI length 134 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0.253 > 0.18 0.253 > 0.18 Return Ducts 0.253 > 0.18 0.253 > 0.18 Fitting Equivalent LengthDetails supply 4X=35,11 A=20,11 G=5,11 G=5,11 G=5,1 A--35,11 Gam: Total EL=110 Return Total ELF I ghtsoft® �. •tw•=emu-,mmP , Comfort BUIder by Wrigttsoft 18.0.16 RSLJ30040 ...Lake (OL) 9tSpedff&ot03T1452ALHG.rLp Calc=W8 FrortDoorfaces: E 2018-JLI-08 2333:50 Page 1 Duct System Summary DIP Entire House «<.- One Stop Cooling and Heating 7225 Sar&mve Cart. Wirter Park. FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: www.OreStopCooling.com Licerse: CAC032444 For: External Static pressure Pressureliosses Available static pressure Supply / r turn available pressure Lowestfri on rate Achial air ow Total eft ;ve length (TEL) Ryan Homes FL Heating 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.253 in/100ft 773 cfm 134 Job: F1452 ALHG Date: 06/06/2018 By-. RI/MC Cooling 0.50 in H2O 0.16 in H2O 0.34 in H2O 0.170 / 0.170 in H2O 0.253 in/100ft 773 cfm N e Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BED2 h 4107 176 122 0.269 7.0 Ox0 VIFx 21.5 105.0 st2 BED3 h 1855 80 61 0.310 6.0 Ox 0 VIFx 14.7 95.0 st2 BTH2 h 644 28 25 0.298 4.0 Ox 0 VI Fx 14.1 100.0 st2 DIN c 3098 110 136 0.274 6.0 Ox 0 VIFx 29.1 95.0 st1 GREAT c 1647 48 72 0.299 5.0 Ox 0 VIFx 18.7 95.0 sti GREAT -A c 1647 48 72 0.306 5.0 Ox 0 VIFx 16.3 95.0 sti Krr c 1935 42 85 0.271 5.0 Ox 0 VIFx 25.5 100.0 sti tMED h 3481 149 133 0.276 6.0 Ox 0 VIFx 23.3 100.0 sti NSTH h 1431 61 31 0.271 4.0 Ox 0 VIFx 25.7 100.0 sti MW IC c 661 14 29 0.253 4.0 Ox 0 VI Fx 24.3 110.0 sti PAN h 398 17 7 0.272 4.0 Ox 0 VIFx 25.0 100.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk sti akAVF 473 558 0.253 711 12.0 0 x 0 VnlFlx st2 41,PkAVF 300 215 0.269 680 9.0 0 x 0 VnlFlx Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Nam i Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Mat Trunk E Ox 0 773 773 0 0 0 0 Ox 0 VIFx EF1 = 50 CFM Fan EF2 = 80 CFM Fan EF3 =110 CFM Fan ER-1 = 50 CFM Fan EFL2 = 80 CFM Fan EFL3 =110 CFM Fan VTR = Vent to Roof VTW = Vent to Wall DV = Dryer Vent RV = Range Vent = Lineset Chase — — = Condensate — - — - = Thermostat 18/8 O SRB = Small Reduction Box LRB = Large Reduction Box FBB = Feld Built Box Job #- F1452 A LHG Performed by RI/MC for: Ryan Homes FL Level 1 AC FADS 13YGC MIN SIZE 40"x40' 36'SEFARATION 16" OFF WALL F'VCREFRIGLINE CHASES BY GC One Stop Cooling and Heating 7225 Sandsoove Court Winder Park, FL 32792 Phone: (407) 629- 6920 Fax (407) 629 - 9307 www.OneStopCoolingmm Scale: 1 : 65 Page 1 Comfort Balch by Wmjt-. fL 18.0.16 RSLJ30040 2018&JuIM 23.34:19 SpadclLot 0MFI452 AL1-IG.nQ