Loading...
HomeMy WebLinkAboutBUILDING PLANSFILE COPY INDEX OF DRAWINGS SHEET NO. DESCRIPTION -CS COVER SHEET 02 ) GN GENERAL NOTES 1 FOUNDATION PLAN 2 2 DOWEL PLAN 3 LINTEL PLAN 3.1 LINTEL LOADS AND DETAILS - CAST-CRETE & LOTT'S XXXO O _ O 0 4 FLOOR PLAN 5 ELEVATIONS 6 ROOF FRAMING PLAN 7 ELECTRICAL PLAN FOR: 8 PRODUCT APPROVAL D1 FOUNDATION DETAILS D2-D4 ARCHITECTURAL DETAILS WA1-W5 WALL ASSEMBLY DETAILS i oull tfilkxnes a n h o m e s. co m TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA GROUND DESIGN SEISMIC SUBJECT TO DAMAGE FROM WIND i ICE BARRIER FLOOD AIR MEAN SNOW Speed'!Topographic DESIGN Frost line DESIGN IUNDERLAYMENT FREEZING ANNUAL LOAD (mph) effects" CATEGORY' Weathering depth' Termite` TEMP` REQUIRED' HAZARDS j INDEX TEMP N/A 160-C N/A Negligible N/A Very48 N/A N/A WA N/A DESIGN CRITERIA: SQ.FT. CALC.'S CONTROL DATE 01-01-1D • FLORIDA BUILDING CODE RESIDENTIAL (FBCR,), REVISIONS 6TH EDITION(2017) r� • ALL LOCAL AND STATE CODES S Q , r' 1' , CALC . S DATE DESCRIPTION • OCCUPANCY - RESIDENTIAL, GROUP R3 •CONSTRUCTION TYPE - VB •MIN. INTERIOR FINISH - CLASS C 1ST FLR LIVING 1,452 SQ. FT. • BASIC WIND SPEED - VULT = 160 MPH GARAGE 3e3 SQ. FT. - VASD = 124 MPH RISK CATEGORY II TOTAL LIVING 1,845 SQ. FT. •EXPOSURE CATEGORY - EXPOSURE C • 1-STORY RESIDENCE - ENTRY le SQ. FT. • 2-STORY RESIDENCE - MAX. HEIGHT AS PER LOCAL AND STATE CODES PATIO 18 SQ. FT. • STATE OF FLORIDA TOTAL 1,882 SQ. FT. CERTIFIED BUILDING CONTRACTOR: CUBIC VOLUME LIVING 12032 SQ, FT. RYAN HOMES 1450 CENTREPARK BLVD. AREA CALCULATION SUITE 340 WEST PALM BEACH, FL 33401 WIDTH DEPTH • STATE OF FLORIDA (ELEVATION A) 40'-0" 47'-4" PROFESSIONAL ARCHITECT: (ELEVATION B) tLQ'—O" 47'-4' JAMES CANTWELL LANAI AR NO. 12079 40'-O" 55'-4" A.B. DESIGN GROUP, INC. 1441, NORTH RONALD REAGAN BLVD. LONGWOOD, FLORIDA 32750 Fax: (407) 774-4078 Tel: (407) 774-6078 DRAWING / CONTRACT DOCUMENT REVIEW BY BUILDER THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. IF ANY ASPECT OF THE CONSTRUCTION (AS DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND IN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE C:"ONSTRUCTION BASED ON THE DRAWING SET. A R C H I T E C T S Design rob Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdeslgngroup.com AA #: 0003325 r �I"IIII'll �om0ovo� E 8 IE O C c SUBDIV. 7LAKE OAKLANDLOT MODEL: 1452 XKX00-00 PROJECT#: 02784.000/00011 PAGE: COVER SHEET 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA Bl1 f DATE: 7/10/18 l SCALE: 1/4"=V—O" 1 SHEET CS or C) GENERAL NOTES 1. 2. 3. 4. 5. 3 7. 8. 9. 10. It 12. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR), 6TH EOIiXIN RMIAND IN CONJUNCTION WITH ASCE 7-10. THE MINIMUM SUPERIMPOSED DESIGN LOADS ARE AS FOLLOWS; A. FLOOR LIVE LOADS lPSF) A.l. SLEEPING ROOMS 30 A.2. ATTICS W/ STORAGE 20 A.3. ATTICSW/OUT STORAGE 10 AA. POOLROOMS 75 A.5. BALCONIES 40 A.6. DECKS 40 A.7. STAIRS 40 A.8. ALL OTHER ROOMS 40 B. FLOOR DEAD LOADS IPSF) B.I. ALL AREAS 10 C. ROOF LIVE LOADS C.1. *" MINIMUM ROOF LIVE LOADS SHALL COMPLY WITH TABLE R301.6 OF THE FBCR, 6TH EDITION (2017). D. ROOF DEAD LOAD PRFI D.1. FIBERGLASS SHINGLES 17 D.2. CONCRETE TILES 25 E. WIND LOAD CRITERIA E.I. BASIC WIND SPEED VULT. =160 MPH, VASD =124 MPH El EXPOSURE CATEGORY C E.3, WIND DIRECTIONALITY FACTOR (KD) 0.85 EA. INTERNAL PRESSURE COEFFICIENT (GC-pI) 0.18 E.5. OPEN BUILDINGS 0.00 E.6. ENCLOSED BUILDINGS t0.18 F. GUARDRAILS AND HANDRAILS LIVE LOAD PSF F.I. GUARDRAILS AND HANDRAILS 200 F.2. GUARDRAILS IN -FILL COMPONENTS 50 GUARDRAILS AND HANDRAIL LOADING SHALL COMPLY WITH R301 AND TABLE R301.5 (FOOTNOTE F,DAND H) OF THE FBCR 2017, 6TH'EDR10N. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALI" DIMENSIONS PRIOR TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK, THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE C@NSTRUCTION AND/OR FABRICATION OF THE WORK, ALSO SEE-DRAWING/CONTRACT DOCUMENT REVIEW BY BUILDER" NOTE ON COVER SHEET (CS). THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC, UNLESS SPECIFICALLY DETAILED. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR GLAZED OPENINGS SHALL BE PROTECTED AGAINST WIND BORNE DEBRIS BY THE INSTALLATION OF STRUCTURAL PANELS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CHAPTER 3, SECTION R301.2.12 OF THE FLORIDA BUILDING CODE RESIDENTIAL, 6TH EDITION (2017). ALL GLASS SHOWER ENCLOSURES TO BE TEMPERED. OPERABLE WINDOWS WITH A SILL PORTION OF THE OPENING LOCATED LESS THAN 24" A.P,P. AND MORE THAN 72-ABOVE FINISHED GRADE SHALL INCLUDE A WINDOW OPENING CONTROL DEVICE THAT COMPLIES WITH SECTIONS R312.2.1 AND R312.22 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED. (2017). WALL AND CEILING FINISHES SHALL HAVE A FLAME SPREAD INDEX OF NOT GREATER THAN 200 PER R302.9.1 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED (2017), WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450 PER R302.9.2 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED (2017). INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS AND VAPOR -PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR/CEILING ASSEMBLIES, ROOFICEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACEES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM E 84 OR ILL 723, PER R302.10 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED (2017). ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CONFORM TO REQUIREMENTS LISTED IN R702.3.1 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED (2017). CERAMIC TILE SHALL BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS LISTED IN R702.4.1 OF THE FLORIDA BUILDING CODE RESIDENTIAL 6TH ED (2017). GARAGES AND CARPORTS 7 3. 4, GARAGE DOOR A. ENGINEERED FOR 160 MPH MIN. WIND LOAD. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER AS PER FBCR 6TH EDITION (2017) SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1318 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN 1 3/8INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS -AND MUST BE EQUIPPED WITH A SELF CLOSING DEVICE R302.5.1 AS PER FBCR 6TH EDITION (2017), SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO, 26 GAGE (0,48 MM) SHEET STEEL,1 INCH MINIMUM RIGID NON METALLIC CLASS 0 OR CLASS i DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. AS PER FBCR 6TH EDITION (2017) SECTION R302.6 &TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THAN Y" -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN YANCH GYPSUM BOARD OR EQUIVALENT. e1TC IAIADI! 1. 2, 3. 4. 5. 6. 7, 8. 9. 10. 11. 12. 13. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ONSITE UTILITIES, SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL FINISH GRADES, PLANTING AND IRRIGATION. PRESUMPTIVE SOIL BEARING CAPACITY IS 2000 PSF ON UNDISTURBED SOIL. ALL CONCRETE FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OR ENGINEERED FILL. BOTTOMS OF FOOTINGS SHALL BE V- 0" BELOW FINISH GRADE (MIN.). IT IS THE RESPONSIBILITY OF THE BUILDER TO PERFORM SOIL BEARING TESTING UNDER THE FOOTPRINT OF THIS STRUCTURE PRIOR TO START OF CONSTRUCTION AND TO VERIFY THAT BUILDING PAD MEETS THE PRESUMPTIVE SOIL BEARING CAPACITY. IF BUILDING PAD AREA TESTING RESULTS IN SOIL BEARING CAPACITY THAT IS LESS THAN THE PRESUMPTIVE BEARING CAPACITY, IT IS THE RESPONSIBILITY OF THE BUILDER TO NOTIFY AB DESIGN GROUP (VIA WRITTEN R.F.I.) SO THAT THE FOUNDATION CAN BE MODIFIED ACCORDINGLY PRIOR TO START OF CONSTRUCTION. AS DESIGN GROUP SHALL TAKE NO RESPONSIBILITY FOR NEGLIGENCE BY BUILDER IN THIS ASPECT OF CONSTRUCTION. FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557, ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN Ys THE HORIZONTAL DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAR OF GRANULAR FILL, PLACE IN W LAYERS AND COMPACT TO 95%MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557. THE BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) EXCAVATIONS TO BE A MINIMUM OF T-0" BEYOND NEW FOOTING LINE, THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE REQUIREMENTS. THIS BUILDING IS NOT DESIGNED TO BE CONSTRUCTED WITHIN A FLOOD ZONE, UNO. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISDICTION, INCLUDING ALLAPPLICABLE STATE, CITY, AND COUNTY BUILDING AND ZONING CODES, SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP DRAWINGS. CONCRETE 1. ALL CONCRETE WORK SHALL COMPLY WITH THE LATEST EDITION OF THE STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE IN BUILDINGS, ACI 301, AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-11, 2. ALL CONCRETE FOR THE FOOTINGS, SLABS ON GROUND, AND MISCELLANEOUS ITEMS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AFTER 28 DAYS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND PROVISIONS OF TABLE R402.2 3. ALL AGGREGATES USED IN CONCRETE SHALL CONFORM TO ASTM C33-03. MAXIMUM AGGREGATE SIZE SHALL BE 4. PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER. 5. BRACE FOUNDATION WALLS, RETAINING WALLS, DURING BACKFILLING AND TAMPING OPERATIONS. LEAVE BRACING IN POSITION UNTIL PERMANENT RESTRAINTS ARE INSTALLED, 6. ALL EXPOSED EDGES OF CONCRETE SHALL BE CHAMFERED'/4". 7. PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE. 8. CONTRACTOR/OWNER TO PROVIDE SOIL REPORT TO ARCHITECT PRIOR TO ANY CONSTRUCTION. 9. FLOOR ELEVATIONS AT REQUIRED EGRESS DOOR SHALL MEET PROVISIONS OF SECTION R311.3.1 IN FBCR, 6TH EDITION (2017). MASONRY 1. MASONRY CONSTRUCTION $HALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE PROVISIONS OF SECTION R606 OR WITH THE PROVISIONS OF TMS 402/ ACI 530/ASCE 5. 2. CONCRETE MASONRY UNITS SHALL BE GRADE "N" TYPE II OR EQUAL AND, IN ACCORDANCE WITH ASTM C90-06b, STANDARD SPECIFICATIONS FOR HOLLOW LOAD -BEARING CONCRETE MASONRY UNITS, MINIMUM COMPRESSIVE STRENGTH OF F'm =1500 PSI. 3. OPEN-END BLOCK MAY BE SUBSTITUTED FOR STANDARD TWO CELLED BLOCK. 4. MORTAR SHALL BE TYPE M OR S IN ACCORDANCE WITH ASTM C270-07, STANDARD SPECIFICATIONS FOR MORTAR FOR MASONRY. 5. MORTAR JOINTS FOR ALL BED AND HEAD JOINTS ARE TO BE 3/8 INCH THICK. THE BED JOINT OF THE STARTING COURSE MAY VARY BUT IT SHALL NOT BE LESS THAN %INCH AND NOT MORE THAN %INCH, REFER TO FBCR, 6TH EDITION (2017), SECTION R606.3 FOR MORTAR JOINT THICKNESS TOLERANCES, 6. GROUT SHALL BE IN ACCORDANCE WITH ASTM C476, STANDARD SPECIFICATIONS FOR GROUT FOR MASONRY, OR 3000 PSI PEA ROCK CONCRETE PER SPECIFICATIONS AND THE PROVISIONS OF SECTION R606.2.11 OF THE FBCR, 6TH EDITION (2017) i 7. FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL REINFORCING. 8. MASONRY WALLS SHALL BE LAID IN A RUNNING BOND PATTERN, REINFORCING STEEL i. ALL CONCRETE AND MASONRY STEEL REINFORCEMENTS SHALL CONFORM TO THE MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES, ACI 315; THE STANDARD SPECIFICATIONS FOR STRUCTURAL CONCRETE IN BUILDINGS, ACI 301; AND THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, ACI 318-11. 2. REINFORCING BARS SHALL BE OF INTERMEDIATE GRADE CONFORMING TO ASTM A615, GRADE 40 (UNO). 3. CONCRETE SLABS ON GROUND SHALL CONTAIN MICRO- OR MACRO -SYNTHETIC FIBER REINFORCEMENT. FIBER LENGTHS SHALL BE 112 INCH TO 2.25 INCHES (13 TO 56 MM) IN LENGTH. DOSAGE AMOUNTS SHALL BE FROM 0.75 TO 3.0 POUNDS PER CUBIC YARD (0.45 TO 1.78 kg/m') IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. SYNTHETIC FIBERS SHALL COMPLY A EDITION 2017 COMP WHEN REQUESTED BY THE BUILDING OFFICIAL AS PER SECTION R506.2.4.2 (1) OF THE FBCR, 6TH E ON ( ) 4. ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE WALL, WITH LAP SPLICES OF AT LEAST 25". 5. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES AT LEAST 25' WHEREVER POSSIBLE. - 6. ; CLEARANCE OF MAIN REINFORCING BARS FROM ADJACENT CONCRETE SURFACES SHALL BE: A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B. CONCRETE EXPOSED TO EARTH OR WEATHER: B.I. #5, W31 OR D31 AND SMALLER 9" C. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WIT GROUND: C.1. 911 AND SMALLER 3a" D. BEAMS & COLUMNS; D.I. PRIMARY REINFORCEMENT, TIES, STIRRUPS AND SPIRALS 1Y:" 7. DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS WITHOUT THE APPROVAL OF THE ARCHITECT. ELECTRICAL 1. ALL ELECTRICAL TO COMPLY WITH THE FBCR, 6TH ED (2017) AND NFPA 70, NEC 2014 EDITION, 2. ALL SMOKE DETECTORS SHALL BE INTERCONNECTED IN SUCH A MANNER THAT ACTIVATION OF ONE DETECTOR WILL ACTIVATE THE ALARM OF ALL THE DETECTORS. WIRELESS SMOKE DETECTORS ARE PERMISSIBLE PER FLORIDA BUILDING CODE RESIDENTIAL, 6TH EDITION (2017) 3. NOTE: ALL ROOMS/ SPACES SHALL HAVE ARC -FAULT TYPE/ TEMPER RESISTANT RECEPTACLES PER FLORIDA BUILDING CODE RESIDENTIAL, 6TH EDITION (2017) REQUIREMENTS 4. 75%OF LIGHTING MUST BE ENERGY EFFICIENT PER FBC ENERGY CONSERVATION, 6TH ED (2017) R404.1. 5. 125-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES INSTALLED IN LAUNDRY AREAS SHALL HAVE GROUND -FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL. 6. OUTLETS FOR DISHWASHER IN KITCHEN TO BE GROUND FAULT CIRCUIT INTERRUPTER (GFCI), OR HARDWIRED AND DISCONNECT TO BE LOCKOUT IN PANEL. 7. REFRIGERATORS, MICROWAVES AND GARBAGE DISPOSALS TO BE ON DEDICATED 20 AMP PANEL. 8. NOT LESS THAN ONE RECEPTACLE OUTLET, IN ADDITION TO ANY PROVIDED FOR SPECIFIC EQUIPMENT, SHALL BE INSTALLED IN EACH ATTACHED GARAGE, AND IN EACH DETACHED GARAGE, THE BRANCH CIRCUIT SUPPLYING THE RECEPTACLE(S) IN A GARAGE SHALL NOT SUPPLY OUTLETS OUTSIDE OF THE GARAGE AND NOT LESS THAN ONE RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH MOTOR VEHICLE SPACE. TIMBER 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) B. NATIONAL FOREST PRODUCTS ASSOCIATION: B.1. NATIONAL DESIGN SPECIFICATIONS INDS) FOR WOOD CONSTRUCTION C. SOUTHERN PINE INSPECTION BUREAU: CA. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER D, TRUSS PLATE INSTITUTE: DA. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI-2007) E. APA-THE ENGINEERED WOOD ASSOCIATION: E.1. ENGINEERED WOOD CONSTRUCTION GUIDE F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 2. ALL STRUCTURAL LUMBER SHALL BE SOUTHERN PINE #2 (MIN.) MACHINE GRADE LUMBER, LINO, A. Fb=1,100PSI Fv=175PSI E = 1,400,000 PSI B. STRUCTURAL LUMBER SHALL CONSIST OF, BUT NOT LIMITED TO; RAFTERS, VERTICAL STRONGBACKS, LEDGERS, BEAMS, HEADERS, AND POSTS. 3. LUMBER FOR INTERIOR BEARING WALLS OR EXTERIOR WALLS SHALL BE SYP#2 (SOUTHERN PINE #2) OR BETTER (UNLESS NOTED OTHERWISE). 4. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. 5. MINIMUM NAILING PER FBCR, 6TH EDITION (2017), SEE TYPICAL NAILING SCHEDULE ON PLANS, 6. ALL BOLTS SHALL HAVE MINIMUM 2' SQUARE STANDARD CUT WASHERS UNDER HEADS AND/OR NUTS WHERE IN CONTACT WITH WOOD, 7. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL CONFORM TO SECTION R602.6 AND R802.7 OF THE FBCR, 6TH EDITION (2017). 8. FOR ASPHALT SHINGLE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 7/16" OSB EXPOSURE-1 OR 1/2" CDX PLYWOOD SHEATHING. PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN 16.ON CENTER & AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING, 9. FOR CEMENTIOUS TILE ROOFS, SHEATHING SHALL BE STRUCTURAL GRADE 5/8' OSB EXPOSURE-1 OR 5/8" CDX PLYWOOD OR 15/32" APA-RATED O.S.B. SHEATHING. PROVIDE PANEL -CLIPS AT MID -SPAN FOR SPANS GREATER THAN WON CENTER AT ALL UNBLOCKED EDGES OF PLYWOOD SHEATHING. 10, FLOOR SHEATHING SHALL BE STRUCTURAL GRADE '/: SUBFLOOR T & G INTERIOR PLYWOOD, GLUED AND NAILED. ADHESIVES CONFORMING WITH PERFORMANCE SPECIFICATION AFG-01 SHALL ONLY BE USED. 11. WALL SHEATHING SHALL BE STRUCTURAL GRADE 7/16' OSB EXPOSURE-1 OR 1/2" COX PLYWOOD OR 15/32" APA-RATED O.S.B. OR 1 /2 " ZIP BOARD SYSTEM, INSTALLED PER MANUFACTURER SPECIFICATIONS. 12, MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT. SQ. 13, PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND COLUMNS WITH 2x STRUCTURAL LUMBER SYP #2. 14. AS PART OF PROJECT, AB DESIGN GROUP WILL ONLY WORK WITH THE DESIGNATED TRUSS COMPANY OR COMPANIES (HIRED BY BUILDER) THAT WILL PROVIDE TRUSS ENGINEERING FOR THE PROJECT. IT IS THE BUILDER'S RESPONSIBILITY TO NOTIFY AB DESIGN GROUP OF ANY TRUSS COMPANY CHANGE ORANY SPECIFIC CHANGES TO TRUSS LAYOUT OR REACTIONS AFTERAB DESIGN GROUP RECEIVES INITIAL TRUSS. PACKAGE FROM DESIGNATED TRUSS COMPANY OR COMPANIES. CORRECT PROCEDURE TO NOTIFY AS DESIGN GROUP OF ANY SUCH CHANGE IS THROUGH A WRITTEN RF.I, PROCESS, AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR SUCH CHANGE WHEN NO R.F.I. IS GIVEN TO ARCHITECT. 15. TRUSS MANUFACTURER SHALL PROVIDE COMPLETE CALCULATIONS SHOWING INTERNAL LAYOUT, MEMBER FORCES AND STRESS CONTROL POINTS AND SUBMIT TO THE BUILDING DEPARTMENT FOR APPROVAL AND TO THE STRUCTURAL ENGINEER FOR REVIEW. ALL CALCULATIONS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER REGISTERED IN THE STATE OF THE PROPOSED CONSTRUCTION. 21 TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982. PREFABRICATED TRUSS TOP AND BOTTOM CHORD LOADS SHALL BE PER THE RECOMMENDED MINIMUM DESIGN LOADS IN APPENDIX B OF THE ANSI/TPI 1-2007 NATIONAL DESIGN STANDARD FOR METAL PLATE CONNECTED WOOD TRUSS CONSTRUCTION. LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO L1360. DEAD PLUS LIVE LOAD DEFLECTIONS SHALL BE LIMITED TO U240. THE CONNECTIONS FOR ALL TIMBER EXPOSED TO EXTERIOR ELEMENTS OR TO PRESSURE TREATED LUMBER SHALL BE GALVANIZED OR PAINTED WITH A CORROSION RESISTANT POLYMER PAINT. ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "SIMPSON" STRONG -TIE BY SIMPSON CO., OR EQUAL. UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE LATEST CATALOG. DRAFTSTOPPING TO COMPLY W/ FBCR, 6TH EDITION (2017) SECTION R302.12: IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE BOTH AND ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE DOES NOT EXCEED 1,000 SQUARE FT (92.9M-). MAXIMUM STUD LOAD CAPACITY (SYP #2) FRAME WALL HEIGHT @ 8'-8" WIN DSPEED/ EXPOSURE 160MPH/B 160MPH/C 160MPH/D 2x6 STUD SPACING @ 16" O.C. @ 16" O.C. @ 16" O.C. 22. IN VENTED ATTICS, BAFFLES ARE REQUIRED TO BE USED AND INSTALLED IN ACCORDANCE WITH SECTION R402.2.3 OF THE FBC, 6TH EDITION (2017) ENERGY CONSERVATION. PLUMBING 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 2. WATER SUPPLY LINES SHALL BE: 2.1. CPVC.OR 2.2. PEX CONFORMING TO NSF 61 AND MEET THE REQUIREMENTS OF R2906.4 OF THE FBCR, 6TH EDITION (2017) " PEX LINES MUST MEET ONE OF THE FOLLOWING, ASTM F $76, ASTM F 877, OR CSA B137.5 PER R2906.4 " FITTINGS SHALL MEET THE REQUIREMENTS OF TABLE P2906.6. PEX PIPE EXPANDS AND CONTRACTS APPROXIMATELY 1" PER 100' OF LINE WITH EVERY 10'F CHANGE IN TEMPERATURE. BECAUSE OF THIS, EXPANSIONS LOOPS MUST BE USED TO ADEQUATELY ACCOUNT FOR EXPANSION AND CONTRACTION PER THE LENGTH OF LINE BEING INSTALLED. " PIPE SUPPORTS SHALL BE A MAXIMUM OF 32" HORIZONTALLY, AND 10" VERTICALLY PER TABLE 2605.1 OF THE FBCR, 6TH EDITION (2017) CONDENSATION LINES SHALL BE MINIMUM -W PVC (SCHEDULE 40), INSULATED WITH W AMAFLEX. 3. CONDENSATION LINES SHALL BE MINIMUM '%' PVC (SCHEDULE 40), INSULATED WITH 1W AMAFLEX. 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. .. 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO THE FBCR, 6TH EDITION (2017). 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO SECTION P2903 OF THE FBCR, 6TH EDITION (2017). - 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. 10, DRILLING AND NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF SECTION P2603.2OF THE FBCR, 6TH EDITION (2017) FIRE-RESISTANT CONSTRUCTION 1. UNDER STAIR PROTECTION: A. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH GYPSUM BOARD, FBCR, 6TH EDITION (2017) SECTION 302.7 EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS OVER FRAMED WALLS APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND, NOT LESS THAN TWO COATS WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926 3. LATH & ACCESORIES PER ASTM-C-1063-11A & R703.7.1 OF THE FBCR, 6TH EDITION (2017). ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: ALL STUCCO CONTROL JOINTS -- KICK -OUT DETAILS -- "L" FLASHING -- HORIZONTAL. LATH AND PAPER DETAILS -- PIPE PENETRATION DETAILS -- VENT PENETRATION DETAILS - WEEP SCREED DETAILS -- CONDUIT PENETRATION DETAILS - CASING BEAD DETAILS -- DRIP EDGE DETAILS - CANTILEVER DRIP EDGE. DETAILS -• CORNER BEAD DETAILS - WINDOW CASING DETAILS -- STUCCO TO SIDING TRANSITION DETAILS - WINDOW FLASHING DETAILS SHALL BE INSTALLED PER ASTM-C1063 - I lAAND R703 OF THE FBCR, 6TH EDITION (2017) 4. LATH SHALL BE ATTACHED TO FRAMING MEMBERS WITH ATTACHMENTS SPACED NOT MORE THAN 7 IN. (178 MM) ON CENTERS ALONG SUPPORTS PER SECTION 7.102.1 OF THE ASTM-C-1063 5. WEEP SCREEDS SHALL BE SECURED TO THE FACE OF THE PLASTER BASE AT NOT MORE THAN 7IN, (178 MM) INTERVALS ALONG SUPPORTS PER SECTION 7.11.1.1 OF THE ASTM-C-1063 MAINTENANCE IT IS ASSUMED THAT THE BUILDER WILL CONVEY INFORMATION TO THE FUTURE HOMEOWNER OF THE NEED TO PROPERLY MAINTAIN THIS BUILDING WITH PARTICULAR EMPHASIS ON EXTERIOR CAULKING AND SEALANTS. IT IS ASSUMED THAT BOTH BUILDER AND HOMEOWNER KNOW OF THE IMPORTANCE, THE REQUIREMENT AND THE EXPECTED LIFE -SPAN OF CAULKS AND SEALANTS. CONSTRUCTION OBSERVATION 1. CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT APART OF AS DESIGN GROUP'S SERVICES FOR THIS PROJECT, 2. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S / CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. CONTROL DATE: 05/18/18 A R C H IT E C T S 2442 N. HUNALU HGAUAN UM). LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA 8: 0003325 E 8 W E C C SUBDIV LOT: OAKLAND LAKE LOT 11 MODEL: 1452 XXX00-00 PROJEICT#: 02784.000/00011 PAGE. - GENERAL NOTES 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA w_1�' DATE: 7 /10 /18 SCALE: 1/4"=1'-O" SHEET NOF SECURE STRAP TO CONIC. W/ (2) 3/16'4' TAPCONS 3 1/2' TI CONC.SLA5 SIMPSON WB ROLL STRAP OR EQUAL SECURE STRAP TO UNIT W/ (2) 06x1 1/4 SHEET METAL SCREWS A/C CONNECTION TO PAD DETAIL 40' -0" -0" 1 W 12 CPAVERS-� m DI HB. 11/2' _lip ■ . . . . ■ ■ ■ ■ IF-- ----- -- ---- ---- —7 lk% 3 1/2' CONC. SLAB `COND. 2 'VTR } �p 2'1 Q 4 2i / +•1� 2' N D1 i I V Y 2 'VTR WC SHWR KITCHEN SINKS AUTO VENT I 2 2 I3 ° '/ f 2 "� WASH 2 r I 2' TUB 3 2' 3' 3' WC LAV CLEAN -OUT Hl PLUMBING ISOMETRIC (SEWER) MODEL U52 RYAN HOMES 4 HB. $0'-0' FIN. ELEv. FIN. CONC. SLAB r S 31/2' CONC, REINFORCED - U/ 6'x6'-U1.4 x UL4 ON 6-MIL POLY ETHYLENE VAPOR BARRIER ON CIIkLL-COMPACTED CLEAN FILL N {$� I DI W/C 6 CONDENSATE LINE_ _ L m BOLLARD a' -a" Q u I" I' PVC CHASE FOR ELEC. e ISLAND 01_111 I'-1 61_011 :===-=1 n i OPT. REF. W. 4,0 LLu--JIi — EXTEND L-TUB ------------ SLAB 1 1/2' i _ cv I I DUI.. r LJ 21'-4" cv PAVERS f Q, 24'x24'xl2' CONC. ' FTCs. W/ (3) s REBARS EA. WAY ON CHAIRS MIN. 3' COVER (2-TYP) r PAVER EDGE S - LINE DI Dl -a}-6 I!2' 9A L DI -6' RECESS SLAB FOR PAVERS ■ ■■ 3 1/2° 3'-4" , a 4"41_0 4 4'-a" 40' -0" rt I I 0 I FOUNDATION T N SCALE: 1/4 = I'-0' ELEVATION 'A' A R C H I T E C T S v rrvvvr�ac�a� PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �IIII"'lll � ommpmv0om� E 8 E O m SUBDIV. & LOT: OAKLAND LAKE LOT 11 MODEL: 1452 XXX00- 00 PROJECT.#: 02784.000/00011 PAGE: FOUNDATION PLAN 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA DATE: 7 /10 /18 SHEET I OF A R C H I T E C T S Desin CoU Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r �IIII'IIIII L0�00�0000J SUHDIV. 7LAKE OAKLANDLOT MODEL: 1452 XXX00-00 PROJECT#: 02784.000/00011 PAGE: DOWEL PLAN 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA 7/10/18 SG'ALE: 1/4"=1'-O" 1 SHEET 2 OF WALL LEGEND 8'-8' 5LK 5RG. SHEAR LUALL SEGMENT WOOD FRAME SEARING LUALL INTERIOR: 2x4 LUALL 0 I(o' O.G., UNO. EXTERIOR: WOOD FRAME WALL PER COMMUNITY SPECIFICATIONS. REFER TO TA5LE N/S3 FOR MINIMUM 0 REQUIREMENTS INTERIOR NON -BEARING FURRING AT MASONRY' WOOD FRAME WALL: 2x4 ® ® 24' O.C. OVER FOIL 24' O.C. MAXIMUM, UN.O LOTT' S CONCRETE P0. BMX 771255 WINTER GARDEN, FL 34777 PH. (407) 656 2112 LINTEL NO. LENGTH TYPE COMMENTS L-I IT-4' 8/28-5-11)U/(UL Pw8?RE"� L-2 4'-8' 6/22-6-1UU/(0)L nrESSED L-3 5'-10, 846-8-(IU/101 L-4 4'-6 8/24-5-(ICJ/(OJL L-5 4'-&' 8/24-6-(I)U/(O L L-fo 7'-6' 8/24-6-(UU/(I)L L-1 4'-6' 8/24-64111 O L L-8 4'-6' S/24-5-(I 90)L L-13 4'-6' 8/24-6-(I)UKO)L L-10 4'-6' 8/24-6-(UU/(0)L 44WST-444R47t LINTEL SCHEDULE LINTEL NO. LENGTH TYPE COMMENTS L-I 11'-4' BF28-I54T PRESTRESSED 8M2-054T ncESSED L-3 5'-10' SFI6-05AT L-4 4'-6' SF24-054T L-5 4'-6' OF24-05AT L-ro SF24-15/IT L-1 4'-6' SF24-054T L-8 4'-6' SF24-054T L-13 4'-6' SF24-054T L-10 4'-6' SF24-054T LINTEL PLAN SCALE: 1/4 = I'-0' ELEVATION 'A' EGCsRES O �SS L-4 A R C H I T E C T S Design roulslnc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 1 E 8 E 10 SUHDIV. 8e LOT: OAKLAND LAKE LOT 11 MODEL: 1452 )cxxo0-00 PROJECT#: 02784.000/00011 PAGE: LINTEL PLAN 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA DATE: Y,/10/18 SCaLE: 1/4"=1'-O" SHEET 3 OF E 8 E 10 SUHDIV. 8e LOT: OAKLAND LAKE LOT 11 MODEL: 1452 )cxxo0-00 PROJECT#: 02784.000/00011 PAGE: LINTEL PLAN 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA DATE: Y,/10/18 SCaLE: 1/4"=1'-O" SHEET 3 OF SAFE LOAD TABLES FOR GRAVITY, UPLIFT & LATERAL LOADS 8'5`REC4ST U-LINTELS SAFE LOADS (LBS/FT) C^�C� GRAV I T T OVERALL LINTEL LENGTH Bib 8F1 0B il6 013 BFlm @B 014 - OTC Ile 30 9 BF12 Ifi ll "PF, ib lg`T_g`pm.lg': 516 E6m TaT,T2 B bF20 19^ B 9P-I8 ;. (TYP2 OF LINTEL) 8118 80h 9502 0301 2'-&' TO (IFEBI TJ }}9 BeaC - 4605 l 'WK i610 _ 1541 4£9m B 4 5 0394 -_ TG,- loss EICI 3'-T' TO 4' -0' (PRECAST) I%6 ?E9) b@= E113 l N 4 0:34 HLE IIB@4 - 6"<3a 19£9 .IIB 4'-'t 4'-6'( F) O PREC40 1599 1349 _ 14 B 6'13 N99 '. l5Hi __ m _ 5E 3. }rL 'm294 15D9 ' 1 3 Be, 0.1' TO 5L4' (PRECAST) 121, 166] L 3¢9¢ '5365 l � l3H] B ? p"ll ' xr i - lil3 "0"m 1 @m9 1 4>m V-5'TO 5'-Im°(PRECAST) 1063 I'm NMI -''B ,In I6 H 60 3 EO 1"' fD< b¢ 6 l 11BI(19::I 4 m &3P6 6061 5'-0I' TO 6'-6' (PRECAST) toe "I 3 em am- - _536D - @39r. aaw ! _ _2IK I@ 9 2E .1 6 t %B5 W-1• TO 1'-6' lPREGABT) l43 --I 4 6 rI) 1 EG P13 6.B "^E4 He G£l eL 4T 33@2 1'-I- TO S'-4' (PRECAST) 554 535 1 46 690 _IE Ile 3 41 2564 '@23 _ a45b 1 4 P5 _. Ins Had@ 2536 SLV TO 10'-6'(PRECAST) 415 bt53)5e - 13 JP/°w9 6�->643_ A106 LL 51 AS 66 R46- 4 3 . 400& I(D'-T' TO II'-4' (PRECAST) 362 946 1566 12h4 S46. I6s1 2N9 _ }21 3eW 40" III, -SA. S<e_ 11, II'-5' TO 12'-0' (PR.ECAST) 31, 9<m y Bl3 1°54 16rA 53 =2mn_ 355] 411 is Eels K2B_ 2311 2BB3 1]'-I' TO 1V-4• (PRECAST) 2% ---- - 411 -24 _ 1 1 B 1'E - i¢T5 O - Ia-B E _ISIA _ Ie e o9l _ _ )3, _ 21 ase3 ; :130 1V-9' TO 14'-0' (PRECAST) gl= _.4 4-,2 NE ___ r l@6 02 N __.. [b' urge_ 91 HIT 21,- \R \R 14 -I' TO 14'-S' (PRESTRESSED) No Z5B N4 Ilea HA N. 1)10 _ie 19.1 NR pale Ne -' 2ol NR 2112 -vR 14'-9'10 W'-4'(PREBTRESBED) TIRE - IF Ne a Ve n-a r33_ HE .ms0 A 2s1D 41 251. 4R-- 15'-W TO T-4' (PREBTREB9ED1 NR 9@9 \R 5H8 IK _AR 95G \R _I_ A6 G i_ 0" e INC NR - .041 uR 11 -E' TO M -4' (PRESTRESSED) NR VF 4e0 \R loC' TIRE 0,l IF 2L2 IF 16 S NF ' 6 19'-9' TO 21'-4' (FFEBTREBBEDJ NR vrz J30 vR ' 6 NR 64.-, .R T II4 ! vR 'S9 Ne - 1466 NR 31'-5'To 23'-O'(PREBTREBBED) NR 160 NR 3n R 550 N¢ 1 Tart `R : 0�1 R 1285 1399 TIRE TIRE R'-1' TO 24'-0' (PRESTRESSED) N¢ --- 129 - v0 49@ 6V BBJ .. I¢31 1ffn AAFF I I]AVT /I RAF-J A-PRFCAPT II_I IIJTPI S C UPLIP LATERAL OVERALL LINTEL LENGTH �= IT 6FI Il 'z-2P o-r b fS�2-li Ells #B '¢CMU (TYPE CF LINTEL) HB.rsr B-I2 tla 2T 9F20 T LIE4 BG24'2i S10 Wrn n63 6 `aa1 2'-B't03'-6'(PRECA6L - - --: IS69 6 9 3 L"1,14 1 C5 J ED 1451.4 - 5.69 61 -- -4YQ': 1015 1=4 less P-O' (PRECAST) 6¢19 l65 l6S 1309 36 210A 316 -@4 2 T 4 ¢ ) 4'-1' TO 4'HV (PRECAST) C _ 13-- 591 691 I013 no e '.e1 09e l L'6 rll a -41113l9 .39 961 45,2 4'-l' TO 5'-4- (PRECAST) _ 411 411 743 mb TICS J 2.T'6 2A8 55� �x2 B'-6' TO 5'-ID' (IRECABT) 9¢3 pEC Im 6 G '" _ -4m 339 616 _ 9 3 _ 6l 1a89 6e 2I, 3 rz 1m7 "0 G2O 33 -.. 3 'e -._ B 9_11. TO 646' (PRECASV 045 140 tbB - 4 alp 52l l2t use - 426 I `�e 6'-T' TO 7'-6' (PREOA6D '� ". 424 Sew 363 l t_l 9- 2 _ ..I ,4 9 4 ,ell. W, l 3Yl I8's =Sea 7'-l' T09'-4' (PRECAST) _ 963 4m 926 BI2 430 591 %• 30 Ts I6 _.. 64> IBe R 2£19 T all_ 5,a - W-5-TO 1V-6-(PRECABD _ 63a i I00 IAt 165 5 y3.46 JB4 260 401 ISO ®'-l' TO II'-4' (PRECAST) rtTl m I,- 1a3 - 462 14-94 Sal I@4, 1a12 43 5 B a II'-5' TO IV-&' (PRECASD <`m 5 0 94(O 3D" 56m 64 BIB m' II _:l _ 244 AT � I T 12'-1. 10 I8'-4" (PREC✓16U -- m l 5 82f b 41 6m1, l00 16. 4!B d ebI 304 a 4 IN, 1220 15'-6' TO P,V (FRECA971 '10 �4 5 I ll a 106D 858 dd 189'. 305 293 100 14=1-TO 14'-B'{pRE0T1eE66E0 4b 9'. 663 _ nee 13Y9 69 1. o4 NR VR 204 15, 91 BB 14'-9' T015'-4' (PREBiRE65EJ) 4 9 330 Ka66 15'.5' TO 17'-4' (PRESTRESSED) let 5 sa "B_ NR ISO 64 3a6 -aE _.i Tao 1De5 Ill '.B 41 1 S� _ 413 I7'-5' TO a'-4' (PRESTRESSED) _ 62 9 4 NR 140 52 166 [6D 439 613 LA 011 11 " 1.11 NR 1V-5' TO 21'-4' (FRESTRE65EO) 125 4a la£ .OJ 1as 1 _ 4e r a40 NR Di Na 40 J I'4 356� 513 bale -1 > 16 9g 22'-I' TO 24'-0' (PRESTRESSED) 6_ NIS 91 30 .4 155 606 'ISl el6 5"PRdpGAAt IIVP"RFCPS.S DOOR U-1 INTOTb SAFE LOADS (LB5/FT) Ca,�,-�,B� BRA V I T� OVERALL LINRL LErJGTH (••oB BRPI¢ a5 eR=1 ale di•FI pBB i oz,�,c E-261 Rya p (TYPE CP LINTEU Bib 0 IP n49 5 Erc--d s .J EhFa i5 br Ile]-TC H9 S l e -IB v oPF O P 156 9'.6' TO 4'-4- (PRECAST) 163E P0'f 9 Eq 4 6 seal sam4 4'-5'?O 4'-6'(PREC46T) 149. _ns 6 .r _ 0 E63 _ BO p B 9 19 _1 3 ¢2 10B93 3 6Z 4'-T TO G", (PRECAST) 066 II 2W` E ...^,tv ' Ten 31 4 - 99 '. >100 B55 653 ELL 5'-9' TO 9-10' (PR$CA9D 010 901 18}H TIE 4 94<B E¢ 5'-IV TO W-B' (FRECAei) l9l 9@ )..3R0 6¢4H 4 9 ,11E 91 4 94}9. l >9 Im893 5 2i T07'-&' (FRECABT) KKK --TS 1 $ ( 49m 4 9 lib - 8993 Ima"b>. 9 7'-7' TO 9'-B' (PREG45i) <I 5�6 993 J23 450 589 _- 566 153 8"PREC46T W/2'RECE55 DOOR U-LINTELS 545EE LOADS (LBS/FT) d I,C`LI, T OVERALL LINTEL LENG7H BCE Ir B,eF (01 BFF 4-I' FIE Ff11-- 532 rt ERF3p-IT (TYPE OF LINTEL) $T-'.; e1i tor -IT vugs 6R 2]-.T RP26 .T 6 45 SPF3m-4T 514m BRJ6 aRFb RGN 905 166e 1 305E 51 3'-b' TO 4'-4' (PRECAST) - PL,, . G'A' l51 444E l - 114m -- IS, 1164 &rl bla •ei2 3 36m7 '9rt3 4'-5' To 4'-6' (PRECAST) s,& 126e 2]2 I,- 939 a 36p1 ze5a� 42T J a. e9G3 n94 693 1013 J9r a'_v To 5- D' (PRECAST) l9T 2 26 2854. 0392 2 6 35 4m6 407 659 655 ml 3 `n 5'-9' TO D'-10' (PRECAST) I 9296 Bl9 -' °9 3>29 382 301 616 -- - =E, 1 33 1bo�. aB9 -- l a sl0- N p--� m 5'-I'i TO 6'-B'(fRECA6T) - 5lF IaE¢ C lb 6t 61 595 168 464 r .969 6'-9' TO l'-6' (PRECAST) 5':6 LE4 >4 rt5 - !'66 ,>67 2960- 21" sine 6l4 963 V-Y'09'-B'(P�CASTi -` al__. �c 1>: - 3l0 490 214 AST- R4GT49 LINTEL SCHEDULE 4 MAT IA 5 ER L I. To 8' precast lintel . 4000 psi f'O. Prestressed Intel 000 Si 2, p 6 p 3. Grout per ASTM G416 f'g 3000 pal w/ Maximum 3/6 Inch aggregate 4 8 to Il Inch slump 4. Concrete Masonry Units (CMU) per ASTM Dee w/minimum net Brea compressive strength - 1900 psi S. Reber per ASTM 4615 grade 60 6. Prestressing strand per ASTM A416 grade 270 low relaxation 7. Mortar per A57M C210 type M or 5 GENERAL NOTES L. fe lde full mortar bed and Head Joints. 2. Whore filled lintels as required. 3. Installation Of lintelmust comply with the archltectural and/Or structural documents. 4. U-Lintels are manufactured With 5 1/2' long notches at the ends to accommodate vertical cell reinforcing and grouting. 5. Reference the CAST-CRETE Load Deflection Graph brochure for lintel deflection information. 6. Bottom field added rebar to be located a the bottom of the lintel cavity. 1. 7/32' diameter wire stirrups are welded to the bottom steel for mechanical anchorage, 8. Caet-In-place concrete may be provided in composite lintel In Ileu Of concrete masonry Units. 9, Safe load rating based on rational design Bill per ACI 318. and ACI 530 10. The exterior Surface of lintels Installed in exterior concrete maSOnry walls Shall have a coating of stucco applied in accordance with ASTM C-286 Or Other approved coating. 11, Llntele, loaded simultaneously with vertical (gravity or uplift) and horizontal (lateral) loads should be chacked for the combined loading with the following equation: Applied tI al OaJo A1212lled horizontal load S 1.0 Safe vertical load Safe horizontal load 12. Additional lateral load capacity can be obtalmed by the designer by providing additional reinforced concrete masonry above the Ilntel. See detail at right: SEE SAFE LATERAL LOAD TABLES FOR LOAD RATING FOR EACH ADDITIONAL REINFORCED CMU FULL COURSE RCL R TYP 2) 5 REBAR GR40 or GR60 AFE LOAD TABLE NOTES I. All values based on minimum 4 Inch 1. For ccmposite lintel heights not shown, use safe nominal bearing Exception: Safe loads for unfilled load .from next lower height shown. Iintele must be reduced by 20% If bearing length is 8. For lintels lengths not shown, use safe load from less than 6 1/2 Inches. next preset length Shown II N Rated 2. NR. of 9. All safe loads m units of u s line r foot pv nd pd a 3. Safe loads are Superimposed allowable loads. 10. All safe loads based on elm I e creed p y sup 4. Safe loads based on grade 40 or grade 60 field span. rebar. 11, The number in the the parenthaets Indicates the S. One e1 rebar may be aubst EUted for two'5 Faber$ percent reduction for grade 40 field added In 8' lintels only rebar. Example T-6" lintel type BP32-I6 safe 6. mile designer may evaluate concentrated loads gravity load = 64121. w/ 15% reduotiCtl 6472 From the safe load tables by calculating the (.85) = 5501 plf maximum resisting moment and all at d-away from face of Support. TYPE 1DE51GNATI0N F FILLED WITH GROUT / U = UNFILLED CTII UAN"5 REBAR OF REBAR Al +''BOTTOM OF LINTEL CAVITY +r 1 1 OF1& =15/1T QUANTITY OF'5 REBAR AT TOP . LNOMINAL HEIGHT NOMINAL WIDTH ?L "5 REBAI AT TOP MIN. IIJJREQ'D 1-1/21, CLEA II� CM.U. -GROUT -5 REBAR AT'BOTTOM OF LINTEL CAVITY BOTTOM RE..I II�IIFORCING 7-5/5'AOTUA4 PROVIDED II4 LINTEL 8' NOMINAL WIDTH (VARIES) SAFE WORKING LATERAL LOADS (PLF) 8' x 8" LINTELS eAFO LATERAL LOADS LINTEL LNTEL (PLF) total Lel T 9Fe PAIN 6'ra' SOLID 1'-10' Ramat Be E=.64 3'-1. Recast 1" 236 4'-m' ...et. R 844 1614 4'-6' Ramat bale 12" 4-0' Fetal 586 1163 b'-4' Remet 666 less FT.Nt 545 1105 b"P Pl 634 I%4 6'-1. Rama! 612 11BB W-W IlPsEst 57s 11n Premel 446 Gee t'-B' Prelmet 415. 094 S'-m' PINFOA 39t 844 8.4' Ramat 354 1$ 9'-4' Ramat Ili 583 10'.6' Recent IV 4S3 II'-4' Pemet IRS 620 Read 164 us I2-W P.1t 143 504 1V' 4' Remet Ilb AN W-O' Recast 93 GET µ-B' R6elnee5d NA Nl 5'-4' Rmvaeid NA XV II PrawmaeC NA 26 11.4' Rlababa PI NA n6 1@'-0' Ravepead NA 59 21'-4- Prow llso NA Is 1T-4• Prsiv.ued NA. 1]0 24 . Reaveaaed NA 93 NR = Not R«cmmo-dsd LOTT' S 19 CONCRETE P.D. sox 771255 WINTER GARDEN, FL 34777 ditrW ..• 'Nm N ..• w NI- b NOMINAL WIDTH/HEIGHT OF LINTEL r PLAIN OR SOLID LINTEL 18/16-P-#U/#L1 No. OF ADDITIONAL #5 BARS IN UPPER OR LOWER LINTEL CAVITY 1.01 LeBm 3'-V 4'-OR 4R_1. 4'-4R A-V 5R-®. b'•B' GOP 71;- Erman ProCaet Fiemlt Pra<aet Possm Reese! Ramat Ramat Reiner Pl SAFEATERA LOADS fPLFI S. DOOR V DOOR HEADER HEADER PLAIN SOLID 1112 2071 see 1671 Gel 1521 1� 13BG Sea 1165 650 1171 504 %4 4R 181 35B 664 }86 6P5 GENERAL NOTES, I. CODES J. P DA BUILDING CODE RESIDENTIAL,&TN TION (2011), SECTIONS t LI EDITION W12 01. 1.3. FLORIDAOBUILDING GORE RESIDENTIAL, ISTHWO EDITION NCRE E (ACI 31 105). t 210T. IA. BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI R BUILDINGS ). 1.4. CONCRETE: SOCIETY OF CIVIL ENGINEERS MINIMUM [DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES (ABLE 1-10). 2. CONCRETE: 2.2 CONCRETE CT U/8TA DA STRENGTH AT E DAYS: 2.1.1. PRE -OAST W/9TANDARD R EINFO CEMEN -6 00 P51 - 2.1.3. IFIGROUT PER A51TY EATS 3000 RCEI'I MAX. 300 AC 1 2,13. GROUT PER ASTM G416 - 3000 PSI W/ MAX. 3/8" AGGREGATE, 8' TO II' SLUMP. REII'PORGIN'G BARS: 22.1. STEEL PLACED IN PRECAST LINTEL AT TIME OF FABRICATION ASTM A615 (GRADE 60) 222. STEEL IN LINTEL AND IQJOCKOUT BLOCK (PLACED IN FIELD) ASTM A&S (GRADE 40). 2�. FRE-5TRESBED STRANDS ASTM A416 1-WIRE, 5TRE68 RELIEVED 210 K51 R.4. DETAIL REINFORCEMENT IN ACCORDANCE WITH ACI 315. TABLE No 1 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" x 8" LINTELS LNTEL LENGTH CLEAR SPA) LNTEL T'PE LINTEL STEEL UMILLED GRAVITY CAPACITY (IML GGTU GRAVITT CAPACITY Tint. (InU U UET CAPACITY (InL nnA UPLIFT "FAGTY (115L (lull BOrtq`I OAR TOP BAR GRAVITY CAPACITY 2'-10' I'b' PRECAST (DR G)R 4P45 1SIS 100e 8529 ICt6W 316' 1'-1. PRECAST (2) `2 (2)It 241E 3a31 3831 485 4N5 4' -V T-V CAST (2)R M-2 1183 2111 2111 33ee Isle, 4'-0 3'-2- PRECAST (DR (2)R 1343 216E 216E 2608 260E 4'-V 3'-4' PRECAST (DR (2R E1 2011 2011 2421 2421 5-• 4 4 0' PREOA5T (2) 3 R Im ISO 'b5l I610 %I 5 10 4 b' CAST O)9 rL R 86 0 1423 µ23 d I l0 1609 b 4 5 PRECAST (2) N (2 R 110 1232 1116 1406 b 6' 2- 5d' PRECAST (24 (2)Z 7W 2N IN 1340 6 B 5 PRECAST IN 154 1184 ISO 1W IOV l b V 6'A' PRECAST V)4 !24 f2R C01 5l0 DIO 991 991 019 1001 7 8 6-1. PRECAST O)4 (2)Z 551 Gas el IN 1041 S 6-5' PRECAST (2)4 (2)Z 510 set GM 7a 904 s-4 1-V FRCA57 G)4 G)R 4B8 a BSI 648 SIT 9-{ S•0' PRECAST O)•4 G)Z 41& V6 l26 4" 1I0. 10.6 9-1' Feel (2+4 (2)4 354 616 60 3s0 613 II d 10'-0' PRECAST G)5 VLs 35 Sol 561 311 Sol 20 0' -V PREOA5i (25 (2)IS Re 525 525 211 6&I a-6 11-Y PRECAST (25 (2)3 711 Ass 488 251 512 IS d p-0' PRECAST (2)e (25 255 458 4E6 114 442 W4 0 IT-8' PRECAST Me, (2)IS Da 430 430 I% SO µ-B Bl PRESTRESSED ms. (2)3 NR Ls 413 250 446 IS-4 I4-0 PRESTRESSED 0)N (2)R NR 3l9 Sit 210 AV 11-4 16.0' PRESTRESSED (2)4 f]1R NA. am 2" Ise 3Il Ell 10.0' FREBIREb6ED (L'S (2)IS NA 224 224 131 284 20-0 B'B' 6 66E0 We f25 NR 101 ill a2 23l 21.4' ]0.0' RE6iRE06ED f1)5 (2) IS NA M 171 ICI 208 19-C' 20 0' PRE81R9SED !1)5 O)3 NR WI 164 100 se 24.0' 12.6 PRESTRESSED (2) IS V) IS NR al 1" 84 163 z REINFORCING SCHEDULE R LOAD CAPACITIES SAFE WORKING LOADS (PLF) B" X 16" COMPOSITE LINTELS LINTEL LENGTH OLEAR SPAN LINTEL T YPE LINTEL STEEL GRAVITY CAPACITY (OnL IInU GRAVITY CAPACITY flnL OOSU UPLFT CAPACITY (JAL (InU UPLIFT j CAPACITY (InL (VRI BOTTOM BAR TOP BAR c i I men I0000 GRAND 0000 Y-6' T-]' PRECAST (2)Is (DR 5931 W000 IOl9m 10110 4'-O' T-B' PRECAST (2)Is (DR 4261 10000 039 0000 4-1. 3'-2' PRECAST (2)R (Z R Sill eal 6591 WCEO 4'-1' V-W PRECAG (2)R' ( 2NO &114 ENE 0000 4'-V PRECAST G)IS 4823 6437 4477 TNT 4.6 CAST PRE 9saw 3 5430 6-4' SAC' PRECAST PRE (2P a ! DR 4 Ile 5 6115 414115 2sw 198} 4 411 PRE () 4 2 5 3934 3934 18W 41BI 6-B' 5.4' PRECAST l]Y4 (LS 3119 3lB )653 3919 T-v 6.2 PRECAST (2)+4 rH 2911 29n 1030 306m 1 .8' 6-,. PRECAST GY4 ( 1196 1196 2931 6'-B' PRECAST f2+4 Cl 15BI 2501 EGA n54 2101 T-0' PRECAST (2+4 (H) 13% 13% W00 25mb a-0' LAST (L+4 (2R 1%9 !969 a3B 10I5 W'-6' 9-Y PRECAST WN (2) 1QI 621 S41 16S 11.4' 10'-0' RECAST V) IS (1 1454 µ55 795 Boul a'-0' 10'-8' PRECAST fL5 (2 We 1335 SET BIG 12'-6' 11'-2' PRELABT (25 nel 1357 sew 12% W-4' I2'-0' PRECAST (L5 f1) 'lµ4 1146 545 We W-0' 12-B• FREOABT (2)5 (1 101 1066 436 02 la-B• 13.4' 57FMBM (11N fi µ3 We 45l 9l1 B-d' 14.0' PRE6iREMID (2+4 f ) a9i tl91 dl1 8}3 Il-4- I6'-0' REb BED (1)1 V3 GIB Me 641 19-4' Ile-0• PRE6T sill Me O5 105 1E8 260 519 Is 0. Ile B' FRibiRB !25 O) 119 9 743 419 21-4' 20'e. meefD l25 O5 633 3 13 42 22'-0, 0'-B' FRbi 6 D fL5 f1 591 5 200 3 1d'-0 11'd' FR9TRES9Ep (D5 (2 q61 /el 161 93m TABLE N0. 3 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" X 20" COMPOSITE LINTELS LINTEL LENGTH CLEAR SPAN LNTEL TYPE LINTEL STEEL GRAVITY CAPACITY (OnL em GRAVITY CAPACITY (IBC (IlriU UPLIFT CAPACITY (U5L flP!D UPLIFT CAPACITY GAL 01 11 00TM- BAR TOP BAR 6 (1 (2)3 GOING WOOD 3.6' 2-2' PAECA9T 0)C (2)R 1646 10000 10000 1001 4 0' 11.11 PRECAST (0n (2)R 550M 1 0¢00 CZC 4.6' 3-2' PRECAST (2)IV q1R W42 1 8541 Wel 4 8' 3.4- FRCAei (LPL (2)1 319a 100� less W000 e 4 4'-0' PRECAST (0S (2)'1 &239 10000. else WOO 5 10 4'-0' PRECAST eVe (2)R 5016 aim 4661 9144 6.4 5-V FRECAST (2)•a O Z 6152 6152 S%1 114 11-1. 5-2' PIECABT G)4 (2)Z b2m 6250 364E &5'S 6 B >-W PRECAST e2)4 f2Z 58I6 ass 3441 6 44 lb 6-1' PRECAST V)IN 2) 43a 4312 2636 A50e l B b'-4' Pill ! )4 4095 4099 Sees 4182 SO _6 6'-8' PRECAST (L4 (2 R 3130 3150 2118 3888 4- T-0' PRECAST (L 4 3470 3420 W18 3561 Fei G)4 2134 2134 W0 1830 10'-6' 9'-1' PRECAST (L4 f1 Z 2211 2211 Jess nee 1I PR-ECA3T (2)5�jj IRK 1V`J 031 2009 107 PRECAST (2)l5 23 Ills Ills Vo e18 IT-v 11'd' PRECAST 2)5 (2)IS ISO 1661 a 1101 13'-A' 11'r0' PRECAST 1115 (2 SOT 1501 13 1414 aHS PRECAST fL5 f1 1399 B99 6% 1323 --V 14.8' 19-4° PRESTRESSED O)'4 G)Z IBa3 1024 Sea 15.4' 14 0' REBiREBBED (2)4 (2)1 Vd m WSB Il-4 Ib-0' FREBTRE89ED l214 f2Z 1331 Se 1991 4n 814 19-4' Ile 0' STRESSED f115 f25 06D 063 3 p 659 900 PRESTRESSED (IS file 9t9 99 3a 615 11-a' 20- 10-0' PRESTRESSED (2)5 851 852 1l3 540 72'0 204) 6TR6SED (215 (2)3 191 t41 MT 50l 14 0 22-5' PRESTRESSED f1)5 1 659 659 415 TABLE No 4 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" X 24" COMPOSITE LINTELS LIMEL LP47H CLEAR BRAN LINTEL TYPE LM1EL EL GR4vITT CAPACITY (CnL flnU GRAVITY CAPACITY (InL (Inu uPLIFi CAPACITr (InL NORI UPLIFT CAPACITY (InL OnU BDTTC4t BAR T� BAR 1'-W' L.I. PRECAST ) SOVES w C000 0ID00 3.6 V." PRECAST (LPL (DR W61 10�0 4 v 1'-8' T (2) Is (2) R 6135 0m00 10m06m 16' 3'-1' PRC45T (2) R (D R SOTO WOOD WOOD 10000 d-B' 3'-4' CABT (2) `2 (DZ 4653 IOOOO %29 10000 5'-4' d'-0' FRECABT (25 (DR 1656 WtCB Teel C"O V-10' 4.v PRECAST (2)5 f2)Z 62311 W020 else, Me, 6 4' S O PRECAST (2.4 (2) It sell W00D 4154 9450 66 5'-1' CAST (1)4 (2)Z 651 Cl we[ M13 11-11 V-4' PRECAST (24 (DR elk NOT 4131 BQO 1.6' 6'-1• PRECAST f2.4 (2Z &VG 6416 3242 6411 TB' b'-4' PRECA91 @Y4 (DR 593E Sell SCSI 6W3 B'-0' b'-8' -0 PRECAST (1)'4 G)li 5%7 5%l 2809 EGGS PRECAST CAST (2.4 (11Z 4831 4631 2551 5031 PRECAST (2.4 G) R 3176 3126 1% Sees PRECAST 0) 4 (L R 1931 2553 243I 2553 $10 CIS 302E 1604 II'-4' Wl' PRECAST (L5 M9 11'-0' 10'-B' PRECAST MIS O 3 2305 2305 IRS 2291 IT-6' II'-2' PRECAST (25 (21IS 241 2µl Wag 2099 13'-4' a'-0' PRElA6i G15 (1)3 1916 816 a81 W2 µ' ' 12'-e' PFECAaT f25 (L9 I'i1B Ilia lB1 W35 14'-0' 13.4' PRE5TR58 •d Z 134E 1346 653 1183 PRESTREfbED a) (2.4 (DR D% T36 6% IIt9 11'-4' IC'-0' PRESTRESSED fL•4 f2R W50 1650 464 910 Ile'-$. FREBiRSEED (29 BW 130 311 l35 20, 1O 0 18 8' BTRE6ED a) f2 is (L 9 9 947 21'4 10-0' (1)5 V) IS 062 1e62 01 OLD 10-8' _TiRE6IREBSED f25 (2)9 9N 565 14-0 2 B' P MyeR ED (2)le (2)3 824 .1 239 413 TABLE No. 5 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 8" X 28" COMPOSITE LINTELS LINTEL LENGTH CLEAR 6P, LINTEL TYRE LINTEL STEEL GR4vlFY CAPACITY (0nL (IP5u GRAVITY CAPACITY (InL (INEU uFLIFf CAPACITY el)5L(InU UPLIFT CAPACITY NOSL Onu BOTTOM BAR EDP BAR 2 10' 1'-b' C T 11 (2) 10000 65.00 3 b 2' 1' AST V)a3 ) 0000 0000 moo Made 4 0' 2'-a' OAST O)Z (DZ 1916 W90Y 1WOO 10m9O 4-6 B'2 T.. (2)1 (DR 10000 d 8 3 4' PRECAST M R (2) R 55WU 10t5W. WOOD W000 5 4 4-0' PRECAST (23 (LPL 9117 ICOWm 836E W200 5-W' 4♦ PRCAST G)3 72) WI Iell Saba W0e0 6-4 W-0' FRG. T (L'4 G)R Fv 10000 5641 Code b-6' a-2 PRECAST (2)•1 (DZ W00e 100m0 5318 W000 6'-0' S-4 PRECAST al (2)1 %30 coal 5021 0000 Ii 672' PRECAST 0)4 O>R 1408 5%l we less T-B 6-4' PRECAST (24 all 1054 Gas %62 B FORECAST G)4 OD 12 6419 'es, 3328 6661 H = PRECAST 0) I ) Z 5664 &V3 3031 SCSI 9 4 B'-0' PRECAST 0)4 (LPL 4561 °Sees 2355 .R45 10 6 9-1' PREABi f24 (LPL 3526 3844 smT x.'6B663 i a 10.V PRECA8i 'G) MIS 32°.W 32W 1521 Sees, 11.0 10-e PRECAST f1)5 2938 2938 $36 21B 12 6' 11.1 PRECAST fL5 WIG 270 no an '2400, 13.4- 11-b PRECAST (25 file 24W 24W W49 1W8 40' a-e' PRECAST (25 (L9 22% 22W 93T all FREOTREB6ED !24 ]ell 2811 126 1431 8 (])•4 (7)Is a616 2023 136-. 74 W l' FRSTREB9ED ( rd 21 loan 1013 516 513 WTI. 4 0.6, 61R fL5 Oils 213 Wet W01 BIB 2 10 O Ile B' D PRE9rRES8ED f115 O)3 µ% µ% 38 3B5 169 21 4' 20 v mom file (2) IS 305 SIR SO 2T-er 10-e' PRESTRESSED (DTI ). 1111 3Il 629 14-0 21-B' PRESTRESSED (25 219 INµ W14 266 517 TABLE NO 7 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (FILE) 8" X 6" LINTELS LINTEL IEFYaiH TYPE LINTEL STEEL FLAN vBOTTOM r GRAVITY (O.Stolsu GRAVITY (InL(Inu UPLIF! (InLoOlw URIP (05_(05u BARTOP BARLApani 3 6 fELAST R B13 565. "S 24M 24e0 4 V RECAST 8 5 t1ATEL RECAST$15 E51 II51 1wie µas 4 B CABT (2)R 8¢6 1081 we] less 19%5 4' R CABT T)5CASs 65§ 93l 930IIµ 1114 RE ) (2 Z6-4'RICASL 511 CO3 See We %b ) (LPL 16 119 115 052 CA66 44S416 416 ll9 13l Bab NWT B' 616T O 3 458 Se 693 693 6E8 Tel le, REGAITT a)4 ) 581 Gas B IS 525 667 l B 6.4 PRECAST !24 (1 3"5 %B "a 499 641 8 0' 6,. PRECAST (24 (DR 353 536 5% 457 609 B-4' 1.0' PRECAST (2 4 2R 334 501 r417 4fl 516 9 -6' a-l' CAST 2 4 (DZ 106 435 435 3W 494 10.6 9-0' PRECAST 4 VV 145 311 34 339 423 II.4' Per PRECAST )5 C5 ]Ile 30 345 Nn 356 a'-0' 10'-a, LABi C G We 282 ]82 n3 215 I]'-6' II'-1' PRECAST 5 50 243 ]43 B1 2M 13 4' 11'-0' PRECAST (25 ! BI 51 191. 3e IBB I4.0' a'-8' PRECAST (D5 tl6 50 161 W9 Bl TABLE No. 9 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (FILE) 8" X 6" RECESS DOOR HEADER INTEL LENGTH CLEAR SPAN LNTEL T(FE LINTEL STEEL IAEILLED GRAVITY CAPACITY GRAVITY CAPACITY (InL(e1511 GRAVTY CCPACRT flPIK- InU IPLR 04PACEY eML(D5u UPLIFT CAPACITY 0I 1_(2n Sol BAR TOPBAR 3 See I691 Weir- 1 124 4.0' 1'-b' FRCLUO ()Z ()R 15i 14B On 111 1553 4-]' 1'-W' CAST (DR f2Z INS No INN FIS ills AP V-0' PRECAST (LZ f2R See {n 230 5% 5% -4' PFaCAST f21R (DR B06 W81 B% B96 5.8' 4'-4' PRECAST (119 5% GAS B98 all all f2.4 (2 458 693 693 See 11 6'-4' PRECAST f2Pq ) 315 5a0 Gas 499 641 S". T.4' PRECAST (24 1 36 400 480 31D 566 0'-1' 8'-4' RECAST f24 Vie 4B 4B 1st 412 7, IF, CONCRETING OPERATIONS SHALL COMPLY WITH ACI STANDARDS. 3.. MASONRY: TI. DESIGN AND CONSTRUCTION SHALL CONFORM TO THE SPECIFICATION OF THE NATIONAL CONCRETE MASCNRT ASSOCIATION AND ACI 530-08. 3,2. MINIMUM MASONRY UNIT 5TRENGTH: PM 1500 PSI. 33. MORTAR SHALL BE TYPE 5. 4. STRUCTURAL: 4.1. SAFE LOAD VALUES ARE BASED ON LINTELS HAVING A BEARING OF S' (WITH A MINIMUM ACCEPTABLE BEARING OF 4' PER FLORIDA BUILDING 69PE RESIDENTIAL, 6TH EDITION (2017), SECTION R606.14 OR FLORIDA BUILDING CODE RESIDENTIAL, 5TH EDITION (2014), SECTION 2104,L5 1) #5 CONTINUOUS 36 �8'Xt6' KNOCKOUT BLOCK TOP BARS •• �; •� SEE SQIEDULE (1) j5 CONTINUOUS 32* STIRRUPS AT 4' 0" cc .,L ED OR WELDS) BOTTOM BAR SEE SCHEDULE (PRECAST) 8/16-S-(1) #5/(1) #5 PRECAST (1) #5 CONTINUOUS '16 i-8'X16' KNOCKOUT BLOCK uw1 TOP BARS: • .y•• SEE SCHEDULE (1) #5 CONTINUOUS .. •,6 4. 7/,32' STIRRUPS AT 4'-0' cc (hEl OR WELDED) Am T�a 8/16-S-(1) #5/(1) #5 PRESTRESSED 3a, 316 Sal 3)?' 8/16-S-(l) #5/(1) #5 TABLE No. 6 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (PLF) 81, X 32" COMPOSITE LINTELS LMIEL LEN'ART LIEAR SPAN LINTEL TYPE LM1aL STEEL BOTTOM BATE TOP BAR GRAVITY CAPACITY (0nL fI GRAVITY CAPACITY (AL ([Ali UPLIFT CAPACITY (InL Eno UPLIFT CAFA071 (I M- (a)'Sl 2"Iff -6 LAOi V (2)R W00C W woo W0OO 2 2' Feel ON 10000 10000 woo to= 4-l' -B 2' rrla BT f2R (2)R 92B WCmO vol 100ase 4-a' 3-2 PRECAST O)Z f2R b940 10000 11 1Al {-B 3.-4. PRECAST We (2)Z 6364 me 10000 MO 5-4' 4 0' PRECAST (29 (DR W010 Wlel %19 bell PRECAST VileO)R eB43 1876 W000 b-4 5.0' PRECAST V)'4 (1)R W0e0 W000 6529 W000 S a' PRECAST V)4 (LPL moo woo 6155 1 641' 9 d PRECAST (2)4 GO, Is W010 Wm60 5BII ICmbC i-6' 6 2' PRECAST (2)4 (2)IV 55& W000 4455 8316 FRECAGIT O)4 (VI BITa W®®m 440 0491 B-0' b B' PRECAST (U% ON Z 1436 W000 Via ll]l B 4" Y-0' PIRE& T (I f2R 6194 Vital 35W 7060 9.4' 51-0' PRECAST 12)4 (LPL 5 93 am M 5501 10 6 9-1' PRECAST (1)4 (11R 40% 5043 2094 424E II 4 W'-0' PRECAST We 2) 3 4221 aCI 1169 3553 a V 10'•B' PRECAST IV MIS 3719 311e 154E 31W 12.61 RECAST a) `5 9 3412 3411 Of 2889 17)5 G)5 29% 299E ala ]5W 14 0 a" • - T .. OA5 Gil) IS )• 2T9 3]31 1131 3231 WEB 149 280 µB4 I4-0' 13+d%" D. G)M 54 Il 4 -0' 4 I&-m' PRE671E80ED P STRESSED O14 MR 1) (2) 12 ry'3 MIS 294b 11¢0 01 1 SH INS 1180 JOB WEB &a9 531 616 S91 ISes IDES 044 20 ` . W-0' Ile-V PRESTRESSED PRESTRESSED (115 2) 5 f25 f2)5 _ (25 114 20-0' PRESTRESSED G13 I K73 3 691 2a O 14-0 10'-8' 12-B' Fa9TRE9SED FREbTIBESSED O15 (L3 1141 147 31l 2l4 4 544 TABLE No 8 RUNE NG SCHEDULE & LOAD CAPACITIES MC FE WORKING LOADS (PLF) X 14" COMPOSITE LINTELS LINTEL EW4iH CLEAR SPAN 4M14TEL TYPE 6NTEL STEEL GRAVITY GRAVITY CAPACITY (IML fIFA UPLIFT CAPgLItt (IFiL (115U UPLIFT LAPALITY (InL (1)5J I EOtHA'I ®AR TOP BAR. CAPACITY (enL (IMU 3 6' Y-]' LAST (2)Z (LPL G)Z (2) IV 2) R (L Z (DR (2 R (LPL OLV (LPL oil 5014 %51 1141 2519 3344 3038 21 2138 1193 110E Sell We SIT 0t00 0000 0000 lO1l 6231 4 n W36 3e38 2%1 ]730 21W 20a PSI 025 617 L !i0 IOCAD 1440 5612 5190 3169 25te 1539 2393. 259 M 164S' µN SSG Well WOOD Wm- 0128 1116 aB90. 386E 3319 2995 2895 1309 22B See 55 Gel I4' 1-8• PRECAST (LPL 4 E' 3-2' PRECAST f11R 1-8 a IV !I)Z 5J' 4-' 0 i G) 9 5 W4 4.6' PRECAST e-4 5-2. CAST (1)4 M`4 b-b' S-1' A9i (1)•4 .-a 5.4' T (1)•a , 1.6' o •2' PRECAST (2 U 1 A• I'll -1. FR.CA6T G) 4 6-{' 1.0' PRECAST RECAST (2 •a (2)4 RECAST (D V - 0'-6' T-2' PRECAST 214 (11 Z (1)9 65 IBB W4T 90s 1265 II3B W41 990 801 616 554 541 1324 1181 108E 1015 Inn 21-0' W-0' W-a' PRECAST PIRCA9i CPS evs a'i' H,2' PRECAST VHS a'-0' PRECAST tl)b (29 fL3 901 BO %2 BW A63 41d 935 %B Je'-8' PRECAST f25 TABLE No. 10 REINFORCING SCHEDULE & LOAD CAPACITIES SAFE WORKING LOADS (FILE) 8" X 14" RECESS DOOR HEADER L1NTB. LENGTH CLEAR SPAN LINTEL TYPE LINTEL STEEL GRAv1Tr CAPACITY fmnL (U5'J GRAVITY CAPACITY (I)5L (InJ UPLIFT CAPACITY (InL (InJ IIPLFt CAPACITY llnL (2)511 BORM BAR' TOP BAR 3 v 2'-{' F 2)R 99B I C' -8'FRI (LPL (2)Z 3651 Code 1440 om 4 2 1-W' CAST (]1R (2)12 33M 92% 6143 I0000 dJ' 3'-m PRECAST (DR (2)12 3088 GOES 613E 9%6 "_0' 3-d' PRECAST (2)R f2)Z M19 42M 5150 T1 5 0' 4.4 CAST (29 O/Z M14 ISO 31T W4 6-B 54' PRECAST 1114 (2)1 2138 2138 2259 2B% l-9' 6-4' RECAST !24 f1) (LIm 20 2" 110 1645 I241 1It 1795 8.8 1'-4' PREXC45T N)k 9-v W." FRECAST O)4 (DZ 516 1436 914 Te5 4 MIS r , � .•. 4 •.'L An .. r rn 4 8/14-S-(1) #5/(1) #5 Sal 3a' A R C H I T E C T S Design G In . ou 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 �IIlIIIIIN hem omoouv� E 8 m E 0 F sysDIV. ilea LOT: OAKLAND LAKE LOT 11 MODEL: 1452 )MOO-00 PROJECT*: 02784.000/00011 PAGE: LINTEL LOADS & DETAILS 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA DATE: 7/10/188 SCALE: 1/4"=1'-0" SHEET 3. 1 OF 8 SQ.FT. CALC.'S IST FLR. LIVING GARAGE 1,452 3S3 SQ. FT. SQ. FT, TOTAL LIVING ENTRY PATIO 1,545 IS 18 SQ. FT. SQ. FT. SQ. FT. TOTAL 1002 SQ. FT. CUBIC VOLUME LIVING 12032 SQ. FT. EXTERIOR MASONRY WALL BRG. HEIGHTS 8'-8' BRCS. LOAD 51%. WALL NON-BRG.WALL COfrpONENT AND CLADDM WIND LOADS BASIC WIND EXPOSURE FOR 3 SECOND OUSTS CALL i WINJDR SIZE ZONE100 MPH W1D FOOTAGE DESIGNATION WIDTH HEKIHT 1 112 Ib -0 0' 192, 84' 5 26.0S/ -44.03 OwGD 2 20 3068 DR 36' 80' 4 301o4/ -301o4 3 Il 38' (03, 4 3231/ -42 62 EGRESS 4 Il E 0S 38, (03, 4 3231/ -42,b2 5 42 5068 SGD 14' 80' 5 28.14/ -51.0S 6 Il 25-SH 38' 63' 4 3231/ -42,62 l Il 25-SH 38, 63, 4 3231/ -42,62 8 Il 25-SH 38, 63' 5 30b4/ -51,16 EGRESS 9 11 25-SH 38, 63, 5 30b4/ -51,16 EGRESS WIND DESIGN CRITERIA A. BASIC WIND SPEED MPH (3 SECOND GUST) VULT=160 / VA60=124 MPH B. INTERNAL PRESSURE COEFFIGENT=+ .IS G. RISK CATEGORY=TYPE II EXPOSURE CATEGORY C NOTE: VALUES FOR COMPONENTS 4 CLADDING PRE55URE ARE BASED ON THE Vult DESIGN WIND SPEED. FBCR, 6TH ED. (2011) ALLOWS THESE PRESSURES TO BE MULTIPLIED BY 0.6 TO MEET THE ALLOWAB6E OR NOMINAL TESTED VALUES USED BY PRODUCT MANUFAGTURBFRS, NOTE: I. PRIOR TO DRYWALL INSTALLATION ON ALL FRAMING MEMBERS T-0' FROM THE FNISH FLOOR WILL BE SPRAYED AND TREATED W/ 'BORATE' A TERTiITE TREATED SPRAY 2xb U n Ib' O.G. CABINET S ECTION �o 0 3'-7" 14'-2" ESM @ m 25-SH 8 13M _ EGRESS 0 r m N Lu 0 OWNER'S SUITE 14'-0'xIY-4" SHOWER HEAD s 6'V APP. C R/T � ti 3'-0 5'-2" 25-51-1 1/0'-2" I CI R/T I 61 GREAT —R 4 14'-a'-a' cLG, I wq L 5 PATIO 5068 SGD DINING 10'-0'x9'-0' 0 x� U 4'-4" 3'-e, 4'-8" 5'-IO" 1 3'-2" 2'-8" 01, c0 @ PAD OUT WALL C R/T e ■ _ III° = W.I.C. I a'-5' GLG. � W/H LLARD COND. ' O F 36'x22' -1 °O O I ACCESS I @ ■ 7'-6" 7'-0" 2—CAR GARAGE IS'-O'40'-O' b'-a, CLG. LECTRICAL PANEL PAD -OUT HB TRUCK BLOCK ® GARAGE WALL <t O16'-0' X 1'-0' OHGD Eel l2 ---- NAl 2x8 3 5H N e i I m I A/C Ia it -Fps i- I LL' HOWER HEAD �� iRiT C TUB ° 6' 8' AFF. 2_$ 0 � = BEDROOM 3 � 0 � H � 10'-0'xil'-0' a' -a' cLG. s m � � N 3'-6" 4'-8" 5'-6" 3'-IO" 7'-4" FOYER R/T ro 3-0 BF. \\ a s cw rd1u iRAG `— v ��10 I L---J 2-6 N w 4) N ro v r v v N O M.T. @ 2 ENTRI. 8'-a' GLG S 13'-2" N BED ROm 0- 3 25-5H EGRESS " 2' 4" 8'-0" 8'-0" -8 16'-0" 8" 2'-4 - 9 4 4'-8" 40'-0" 0 FL0 R' PLAN SCALE: 1/4 = I'-0' ELEVATION 'A' A R C H I T E C T S nvvvvvv�r� a11.v PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �e000m000v� SUSDIV. ec LOT: OAKLAND LAKE LOT 11 MODEL 1452 MOO-00 PROJECT#: 02784, 000/00011 PAGE: FLOOR PLAN 160 MPH EXP. C ARCHITECT STATE OF FLORIDA DATE: 7 /1 O /18 SCALE: 1 /4"=1' — 0" SHEET OF0 SHINGLES SCORED LINE (TYP) ATTIC VENT CALCS AREA OF ATTIC 1964 SUE NET FREE VENTILATION AREA REQUIRED (1/300) 6.21 SQ.n REQUIRED VENTILATION AREA (6.21 x 144) 894.7 SQ.IN. MIN. REQUIRED VENTILATION IN UPPER OF ATTIC (0.5 x 894.7) 447.4 SUN. OFF RIDGE VENTILATION AREA 115 SQ.]N./vm SOFFIT VENT VENTILATION PER LF 11.74 SQ.IN.IIY TOTAL # OF VENTS REQUIRED 3.89 TOTAL # OF VENTS PROVIDED 4 REQUIRED SQIN VENTILATION IN TOP OF ROOF 447 SON. REQUIRED LF OF SOFFIT VENTILATION 39 LF PROVIDED LF OF SOFFIT VENTILATION 187 LF SHINGLES V-8" BERG, ------------- _— TEXTURED CEMENTIOUS COATING PER IASTM C926) (TYP) 0'-0" FIN. FLR., v u�a��ai�ai�o • • FRONT -ELEVATION SCALE: 1/4 = 1'-0' ELEVATION 'A' 0'-&" 5RGz. H-4 T,�_- 6'-S" HDR. HG,T. 0'-0" FIN, FLR. 8'-S" 5fRGro. HGiT I ' -V) 6'-S" HDR. HGT,� 0'-0' FIN. FL 1' -0' BRG. HGiT. 0'-0' BRCS. HGzT. II-0" 1'-O"� 8" HDR. HCaT. 6'-8" HDR. HGT. oL —6' W. SCORED LINE (TYP) —TEXTURED CEMENTIOUS COATING PER (ASTM C926) (TYP) j4O'-0" FIN. FLR. 0'-0" FIN. FLRoL _ SHINGLES I' 11YP)� 5 OFF -RIDGE VENT F-1 J TEXTURED CEMENTIOUS COATING PER IASTM C926) (TYP) RIB �EIJ ATIN SCALE: 1/4 = 1'-0' ELEVATION 'A' SHINGLES I IT1 P)� OFF -RIDGE VENT 5 OFF -RIDGE VENT --------------------------------- OFF-RIDGE VENT c0 TEXTURED CEMENTIOUS COATING PER IASTM _ —_—_-- G926)(TYp) _------ RY R ELEVATION SCALE: 1/4 = I'-0' ELEVATION 'A' 0'-S" 51RG. HGzT. TEXTURED CEMENTIOLIS2'-0" COATING PER IASTM C926) (TYP) ------------------------- N �0'-O" FIN. FLR, LEFT ELEVATION SCALE: 1/4 = 1'-0' ELEVATION 'A' HDR. HG7. 0'-0" FIN. FLR. 5RCs. IHGT, t- 11II O HDR. HGiT. _ I _ o0'-(I" FIN. FLR. I A R C H I T E C T S 4Design Group—inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 r � �I"IIIII" Lo�ooOmvov� E 8 C6 0 C svHDi —LOT: OAKLAND LAKE LOT 11 MODEL: 1452 XXX00-00 PROJECT#: 02784.000/00011 PAGE: ELEVATIONS 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA "3& DA�tE: 7 /1 O /18 ' SCALE:1/4" SHEET 5 OF A R C H I T E C T S GON'ROL pAT= 2T-ml-IS CONNECTOR SCHEDULE SIMPSON USP DES. UPLIFT GRAVITY DES. UPLIFT GRAVITY FASTENER _ META-16 1450 HT4 6-IS 1400 0) 106 x 114' I -PLY, (6) 166 2-PLY, (USP: (10) 10d X 1 14" - NO ad OPTION) (2) META-16 1565 (Z)HTA 16-IB 2800 00) 10d x 1 1/2' I -PLY, (USE: (10) Iod x 1 1/2V I9o0 (14) Ibd 2-PLY (USE: NO 16tl OPTION) _ HETA-16 alo PTA 16 ISIS (9) Iod x 1 1/2' I -PLY, (8) Ibd 2-PLY LISP: (10) 106 x 1 1/2% NO Ibd OPTION _ HE74-20 laic LTA 20 1615 (9) IOd x 114' I -PLY, (0) 16d 2-PLY USE: (10) 1Oa x 11/2', NO Ibd OPTION r z 0 (N (2) HE74-20 2035 (2) H7A-20 3110 00) 10d x I IR" 1-PLY USP: (10) lad x 1 1/2' 500 02) 16d 2-PLY CUSP: NO 16d OPTION) LGT-2 215o LUST-2 1915 (l) - I/4' x 2 1/4' TITEN, 2 PLY (USP: BLK (5) 1/4' WB, WOOD ll6) IOd PETAL-20 2480 NO USP CONVERSION FOR SIMPSON DETAL-20 oa) - IOd x 1 1/2, PLY MGT 3965 MUC-i 4000 (V 5/8' ATR IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (22) 10d TO WOOD NSF: (28) 1OdM�D)HGL2 109Bo HUGT-2 9365 (2) 3/4' AT.R IN HIGH STRENGTH EPDXY (MIN. 12- EMBED)(16) 106 TOWOOD (USP: WOOD (+ 10530 HUGT-3 936S (2) 3/4' A.TR IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (16) IOd TO WOOD (USP: WOOD (LGT3-SDS2.5 3265 LUGT-3 5330 (12) SDS 1/4'x2 14' TO GIRDER, (4) 3/a' x 5' TITEN HD TO WALL (USP: CONC, (4) 3/6' X 5' WE LTA2 1210 PARALLEL TO WALL 1425 PERPENDICULAR TO WALL LPTA 155S (10) 106 x 1-1/2' NaF: (10) 10d x 1 1/2' VAT 4940 NO USE CONVERSION FOR SIMPSON YGT (U 5/a' A.T.R IN HIGH STRENGTH EPDXY (MIN, 12' EMBED), (I6)-5DS 1/4'X3" TO WOOD (2) VG-T 1I85 O U5P CONVERSION FOR SIMPSON (2) VGT) (2) 5/8' A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12' EMBED), (321-5D5 I/4'X3' / 2 PLY MT5-12 loco TW 12 1595 (14) 10d .1 l4' NSP: (14) ad ¢ I IR% (14) 106) H15-16 1150 TW 16 1660 06) 106 x 1 1/2' (USP: (16) IOd x 1 14" (16) 106) HT9-20 1450 20 2045 (24) IOd x 11/2" (U5P: (24) IOC x I V% (20) 1Od) HT5-24 1450 [H7W TW 24 2045 (24) lOd x 1 1/2' (USP: (24) 1Od x 11/2", l20) 1Od) LSTA-12 + 925 STA 12 9TM (10) Icd USP: (10) 10d LST4-IB ++ 1235 STA IB 1360 (14) IOd USP: (14) 1OdMETA-0 + 1315 6TA-IB 1315 (14) 1Od USP: (14) lad + 1640 ETA-24 1150 (IS) ad USP: (a) ad NM874-24 d MS74-30 +• 2050 MSTA-30 2140 (22) IOd USP: (22) lad Q M674-36 + 2050 ME7A-36 2525 (26)10d USE: (26)lod F-- MSTI-36 3800 KSTI 236 3090 (36) 100 z I I4' USP: (3a) [ad x I I/2' -_ M5TI-46 S065 KTSI 246 4250 (48) ad x 1 1/2' USP: (48) lad x 1 1/2' H6 S50 LET 6 1555 l8) ad TO PLATES, (5) 8d TO STUDS (USP: (a) 8d x 1 1/2', (16) Bd) SPA 885 SIFT 4 945 (6) IOd x 1 1/2- TO STUDS USE: (6) 106 x 1 1/2' TO 57UDS A34 395 MP 34 410 (4) ad x 1 1/2' TO BEAM, (4) ad x I I/2' TO POST. USE: l4) ad x I I!'TO BEAM, (4) Bd x I Id' TO POST. HCP9 645 HHCP 2 1010 l'3) lad x 1 1/2' USE: (10) 106 x 114' TO TRW56, (10) IOd X 114' TO PLATE HIOA 34c RT 16A 2180 (18) 106 x 1 I/V USE: (5) 10a x 1 1/2" TO TRUSQ (8) lod X 114' TO PLATE VGT (HDU4 a565 PHD 4A 4535 Ob)-SDS 1/4'x3' TO WOOD, (10)-5D5 1/4X2 14' W/ THREADED ROD, (2l NUT5/WASHERQ PLY USE: 5/B' ATR MIN. 1' EMBED SET N HIGH STRENGTH EPDXY, (10) WSW WOOD SCREWS VGT e H010 494c TDX l0 5110 (l6)-SDI I/4'x3' TO WOOD, (3)-3/4' STUD BOLTS W/ THREADED ROD, (2) NUTS/WASHER/2PLY USE. 118' ATR MIN. 1" EMBED SET IN HIGH STRENGTH EPDXY, (4/ 1/5" THRU-BOLTS ABU 44 2200 6065 PAU 44 2535 6115 lD 5/8' A.T.R. IN HIGH 57RENG7H EPDXY, /MIN, 1' EMBED.) IN CONC„ (12) lad TO WOOD USP: SAME AS SIMP50N N ABU 66 j 2300 12000 PAU 66 2535 L'Se () 5/8' AT.R. IN HIGH STRENGTH EPDXY, fMIN. ?' EMBED.) IN CONC., (12A6d TO WOOD USP: SAME AS SIMP60N LT119 ++ 134o LTS 19 1205 !V 3/4' ALR IN HIGH 5TRENGTH EPDXY, (MIN. 1' EMBEDI IN CONC., (8)10d TO WOOD USE: SAME AS SIMPSON a O LT7205 ... ISOO LT5 201B 1105 (U 1/2' ATR. IN HIGH STRENGTH EPDXY, (MIN. T' EMBED) IN CONC., (Ic)10d TO WOOD U5P: 3/4' ATR MIN T' EMBED SET IN HIGH STRENGTH EPDXY, (10) Ica, (10) 1Od x I Ill', 2-14' _ U z Q HTT4 4 4 55 HT 45 4465 _ (U 5/0' AT.R IN HIGH STRENGTH EPDXY (MIN. T' EMBED) IN CONO„ (IS) SCmO X 114' NSP: (20) 166 X YIR9 - ' ) i d (20) ad x 1-14' (2®) 16d x� 4 USP HAS MORE NAIL OPTIONS: <20 0 H7T5 BOBO HTT45 5430 (I) 5/8' A.T.R. IN HIGH STRENGTH EPDXY (MIN 1' EMBED) IN CONCIN CONC, (26) lad X 2 lQ' (USP (20) 16d X 2-1/2') USP HAS MORE NAIL OPTIONS: (2a) Ica, (28) 100 x -IR', (20) lad x 2 1/2' HHDOII-5D5 25+ 11010 UPHD 11 120W (U I' AT.R IN HIGH 5TRENGTH EPDXY, (MIN. 10' EMBED) IN CONO- (24) 9D5 A' x 2h' WORD SCREWS NIP: (24) W53 LLbOD SCREWS) HDIB 6645 TDx 10 5i10 (V 78" A.B. IN HIGH STRENGTH EPDXY, (MiN. 1' EMBED.) IN CONO., (3) 3/4' STUD BOLTS TO WOOD (USP: (4) 1/8' BOLTS) N MBHA a56/1125 3415 5330 NFM35X12U 3165 119P SIMPSON: (U 3/4' AT.R N HIGH STRENGTH EPDXY, (MIN.6l5' EMBEDMENT) IN OMU. TOP, (I13/4' A1R IN HIGH STRENGTH EPDXY, (MIN. 6]5' EMBEDMENT) IN CMU. FACE, 08)10d TO BEAM USP: (U 14' J-BOLT W/ MINIMUM 6: EMBED, I NOT LESS THAN 4' FROM EDGE OF CONC W/ 3/4' PIA MW RAM6ETREDHEAD DYNA BOLT SLEEVE ANCHOR OR EC. W/ MIN. 5- EMBED DEPTH INSTALLED IN THE FACE. W ('� HU5C412 (WOOD) 3635 2660 (FLR) HU54121F 3060 3¢50 (FLR) <lo) 166 TO HEADER, (10) Ibd TO WOOD USE: SAME AS SIMPSON 3265 (ROOF) 3226 (ROOF) zPU-�IO G410 (CMU 1BIO 5085 HD410 IF 1905 9195 (IB)1/4' x 2-3/4' TITEN (9 PER FLANGE) TO CMU, (10) 1Od TO WOOD: (USP: 0a) 1/4" x 3' W93 SCREWS, (a) 106 TO WOOD. Q (CMU) 1B10 5085 HD210-21F S05 9PI5 W (a) IOd TO WOOD0210-2 05B 1/4' x 2-3/4' TITEN (9 PER FLANGE) TO CMU, (10110d TO WOOD: (UfiP. (8) I/4" x 3' 3 SORE 6.-9 (CM 1 IBIO 4000 HD210-3ff 1906 H'15 NO USE CONVERSION 'OR SIMPSON LGrUM26-2-905 (18) I/4' x H-3/4" TITEN (9 PER FLANGE) TO CMU, 00) lad TO WOOD: (U5P: (8) 1/4' x 3' W93 SCREWS, (10) 10dCREWS, (10) TO OD UM26-2-SDS 1430 5595 (4) 3+8' x 4' TITEN HO ANCHORS (2 PER RLANGE) TO CMU, (Al 1/4' X 2 I/2' SD5 SCREWS TO WOOD HIGH STRENGTH EPDXY = SIMIS SET EPDXY -TIE'. CONTACT THE ARCHITECT/ENGINEER OF RECORD FOR WRITTEN APPROVAL PRIOR TO 5jB6T17JTiNG FOR SIMILAR EPDXY PRODUCTS OR U5P - CIA ADHESIVE ANCHORING SYSTEMS. • WHERE ANCHOR EMBEDMENT IS GREATER THAN 1" DEEP, THE VERTICAL CELL N CM, WALL MUST BEFILLED SOLID U/ GROUT. . 106 COMMON NAILS CAN BE SUBSTITUTED WITH IOd x I I4" NAILS IN CONJUNCTION WITH /-- 23% REDUCTION IN THE ALLOWABLE LOAD. WRITTEN APPROVAL FROM THE ARCH;TECT IS REQUIRED FOR THIS APPLICATION PRIOR TO INSTALLATION- cn .++ MINIMUM EMBEDMENT INTO THE TOP OF 4 BONDBEAM WILL BE 5', MINIMUM E­I5EDMENT ITO THE OUNDA'TION WILL BE 1' W F- A.T.R. - A-30- ALL-l-READ ROD (SIZE, PROTECTION TYPE,'-ENGTH, ETC. VARIES) OBECAUSE OF THE WIDE VARIETY OF MATERIALS, LOCATIONS, AND CONDITIONS THAT MAY .-FFEC- CONNECTORS. THE CONTRACTOR MUST BE RESPONSIBLE FOR MAKING SURE THAT THE PROPER CORROSION PROTECTION IS USED. WHEN USING 6TAINLE55 STEEL CONNECTORS USE STAINLESS STEEL FA5-ENER5. WHEN USING' '-MAX / HDG GALVANIZED CONNEGORS USE rASTENERS GALVANIZED PER A5TM-A153 USE OF EXPANSION ANCHORS WILL BE EVALUATED ON AN INDI V IDJAL BASIS AND MUST H : /E LRITTEN APPROVAL FROM THE GRc4 EC /ERG-NEER OF RECORD PRIOR TO USE. Al-_ CONNECTOR VALUES 545ED ON 51MP50N 'WOOD CONSTRUCTION CONNECTORS C-201J' . ':` GH W'ND-RE315TANT CONSTFUCTIOI.-4WC9, AND ANCHORING a FASTENING 5Y6TEM5 FOR CONCRETE < MASONRY CATALOG C-546-2012. EXTERIOR MASONRY WALL BRG. HEIGHTS LOAD® WALL NON-BRG.WALL MINIMUM UJALL AND HEADER STUD REQUIREMENTS MAXIMUM HEADER SPAN (ft.) UP TO 5'-O' TO 8'-0. UN.O. W-11 1/2' 'I'-11 1/2- AND UP NUMBER OF HEADER STUDS SUPPORTING END OF HEADER 1 2 g NUMBER OF FULL LENGTH STUDS 2 AT EACH END of: HEADER 1 3 FRAMING NOTES: 1. HURRICANE STRAPS TO BE MANUFACTURED BY SIMPSON STRONG -TIE OR EQUAL, U.N.O. 2, TYPICAL HURRICANE STRAPS ARE AS FOLLOWS, U.N.O: • TRUSS TO MASONRY/CONCRETE SHALL BE META-16 • FLOOR JOIST TO MASONRY/CONCRETE SHALL BE HETA-16 AT EACH END AND 32" ON CENTER ON JOISTS PARALLEL TO WALL. • TRUSS TO BEARING WOOD FRAMING SHALL BE MTS-12 3. TRUSS TO TRUSS CONNECTIONS AND HANGERS SHALL BE DESIGNED AND SUPPLIED BY TRUSS MANUFACTURER. 4. REFER TO TRUSS MANUFACTURER'S SIGNED AND SEALED DRAWINGS FOR LOCATIONS, PROFILE, AND SIZE OF ROOF/FLOOR TRUSSES. 5. HEADER SPAN CHART & MIN, WALL & HDR. STUD REQUIREMENTS ARE STD. U.N.O. ON FRAMING PLAN. 6. CONT. STRUCTURAL SHEATHING TO BTM, OF FLR. TRUSS/BEAM MUST NOT BREAK 1'-4" MIN. FROM 2ND. FUR. LINE r� I I I I I I I I I I tiA I I I ��Q I II i I I a�o'-011 SILO, 41_0I1 CII 6, 0 _0II BI Ix4 BTM. CHORD BRACING — l2' O.C. MAX., SECURED W/ (2)10d COMMON NAILS 52 EACH CHORD INTERSECTION (TYP.) 1 1 ---h Ell S > i 71IT Tr__ 11 - ---- F 54Cs V_1�v FJ4I it u 11 u I -19 1 pal _.L R IB FRAMING p" L N SCALE: 1/4 = 1'-0' ELEVATION 'A' i Jl J3 J5 (2) META-16 AASG Al 4n/1 45 OLD` T_ 0 44 O OQ 43 Ci O� LL A2 _ j z Z U Al [f 4 ff Q A2 1ig6—m1!i CI CI C2 C-AG J4 J2 Des Gr )t Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www. abdesigngrou p.com AA #: 0003325 ��o��omo�omJ SLTBDIV. & LOT: OAKLAND LAKE LOT 11 MODEL: 1452 XXX00— 00 PROJECT*: 02784.000/00011 PAGE: ROOF FRAMING PLAN 160 MPH EXP. C ARCHITECT STATE OF FLORI,,A g- 1 DATPE�, 7/10/18 GALE: 1 /4"=1' — 0" SHEET 6 OF 8 ELECTRICAL I=ND 5YM50L DEFINITION NOTE5 110V DUPLEX RECEPTACLE IIOV FLOOR ® MOUNTED DUPLEX RECEPTACLE 110V SWITCHED BOTTOM HALF SWITCHED DUPLEX RECEPTACLE IIOV GFI DUPLEX EQUIPPED W/ GROUND FAULT (TAMPER RESISTANT CFI RECEPTACLE TYPE) TYPE) ® 220V RECEPTACLE 4 WIRE CaNNECTION IIOV DUPLEX EQUIPPED V GROIMD FAULT WP uJ/CxFI RECEPTACLE MTEPoIPfER (WEATHER PROOF) SWITCH 3-WAY SWITCH 4 4-WAY SWITCH LIGHT FIXTURE - WALL MOUNT LIGHT FIXTURE - CEILING MOUNT LIGHT FIXTURE - RECESSED LIGHT FIXTURE- (H) HANGING LIGHT FIXTURE - CEILING MOUNT LED �(,)( LIGHT FIXTURE - FULL CHAIN LIGHT FIXTURE- K KEYLESS LIGHT FIXTURE - VAPOR PROOF �( LIGHT FIXTURE - PENDANT EXHAUST FAN MOTOR LIGHT STRIP LIGHT FIXTURE - FLUORESCENT LIGHT FIXTURE - UC UNDER CABINET — LOW VOLTAGE PANEL PANEL METER SD SMOKE BATT. BACK-UP W/ HARDWIFE DETECTOR INTERCONNECTED CARBON MONOXIDE BATT. BACK-UP W/ HARDWIRE DETECTOR INTERCONNECTED CEILMG BOX REQUIRED TO BE O J-BOX `.�IIPPORTED N ACCORDANCE W/ Box MARKED AS SUCH FOR INSPECTION FLOOD LIGHT DG DOOR CHIMES TV TELEVISION JACK TELEPHONE JACK 4 GAS OUTLET LOAD CALCULATIONS ONE FAMILY DWELLING WITH HEAT PUMP (NEC CODE#D2) HOUSE PLAN: 1452 LOAD INFORMATION VA 1452 SQ.FT. GENERAL LIGHTING X (3) = VA PER SQ.FT. 4,356 (2) 20 AMP APPLIANCE CIRCUIT AT 1500 VA EA. 3000 (1) LAUNDRY CIRCUIT AT 3000 (1) RANGE AT NAME PLATE RATING OR COOKTOP/OVEN 12000 (1) WATER HEATER 9000 (1) DISHWASHER 4000 (1) CLOTHES DRYER 10000 (1) DISPOSAL (1/3 HP) 246 SUBTOTAL OF GENERAL LOAD 45,602 FIRST 10 KVA OF GENERAL LOAD AT 100% 10000 REMAINDER OF GENERAL LOAD 0 40%= 35,602 VA x (4) 14,241 TOTAL NET GENERAL LOAD 24,241 5-TON HEAT PUMP#1 30 AMP X (240 VA) = 7200 5-KW ELECTRIC HEAT 5000 VA x (65%) 3250 NET GENERAL LOAD 24,241 NET TOTAL HEAT 10.450 TOTAL LOAD 34,691 CALCULATED LOAD FOR SERVICE 34,691 VA / 240 V= 144.55 200 AMP SERVICE (3) • 1 THHN/THLLN COPPER CONDUCTORS, (U • 6 THHNRHUN COPPER GROUND IN 2" CONDUIT. TRANSFORMER BANK, 5MVA VOLTAGE, 1620AB200-24014SOV NEMA 3R 200 AMP SERVICE, SINGLE PHASE 120/240 TYPE: UNDEIasI�lA�lp COMBO VOLT 42 AVAILABLE INITIAL SYMMETRICAL FAULT CIRCUIT DISCONNECT CIRCUITS AT SECONDARY SIDES (120/240 VOLTS) M AND METER MLO MAXMUM FAULT CURRENT, tWW amps CAN POWER COMPANY 200 TRANSFORMER AMP. PHONE / DATA WEATHER PROOF Box SERVICE BY OTHERS INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS GRADE LINE 200 AMP ELECTRICAL R15E:R PROVIDE E ENCASEDfrHWN FOOTER STEEL AND NOTE, COLD WATER PIPE. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY W/ NOTE, IF PVC 18 USED THERE 18 APPLICABLE PROVISIONS OF THE NATIONAL ELEC. CODE, LOCAL P BCNp/GROUND TO GOLD WATER PIPE CODES, AND THE LOCAL POWER CO. COACH LIGHT ELECTRICAL T"IL N SCALE: 1/4 = P-O' ELEVATION 'A' GABLE/TV WEATHER PROOF Box PA JACK DED.20 AMP OUTLET FOR M. WAVE A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 EQ V W 0 .0 SUBDIV. 8e LOT: OAKLAND LAKE LOT 11 MODEL: 1452 MOO-00 PROJECT#: 02784.000/00011 PAGE: ELECTRICAL PLAN 160 MPH EXP. C ARCHITECT STATE OF FLORIDA 3& 1 DATE: 'i110/18 SC �T ,E: 1/4"=1' - O" SHEET 7 OF A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #; 0003325 �"IIIII"I L ommo�v000J SUBDIV. & LOT: OAKLAND LAKE LOT 11 MODEL: 1452 BOO-00 PROJECT#: 02784.000/00011 PAGE: PRODUCT APPROVAL 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA 7/10/18 19CALE: 1/4"=1'-0" (0 5 REBAR VERTICALLY l0 5 REBAR VERTICALLY W/ CONC. - W/ CONC, POURED CELL (2S' MIN LAP) POURED CELL (25' MIN LAP) - R-{,I INSUL. MIN. - TEXTURED CEMENTIOUS COATING z _ a' cm D_ z W I', PER (ASTM C826) (TYP.) Na zQ - 8'CMU N E L ` Id' GYP. ILL. BD. 9 0 CURB HEIGHT VARIES 0,: WOOD BASE ~ N W_ z E az E 6-1 VZ' GONC, FEEIOR Fi. -1 IMES IAxWIA UAIF OR FIBERMESN ON `� 3 IR' CONC, REINF. W/ 6'xb' —-MIL POLY ETHYLENE VAPOR = WL4xWA IUI.F OR FIBERYIESH ARRIER ON WELL -COMPACTED F4-1 ON I IL POLY ETHYLENE LEAN TERMITE TREATED FILL VAPOR BARRIR ON Z W z K DELL -COMPACTED CLEAN TERMITE TREATED FILL m O CESS 4 4 4 (2) 5 MBAR ON CHAIRS U O' BAR ON CHAIRS 1-STORY FOOTING 1-STORY FOOTING �1 W/ BLOC KWALL T GRAG • 4 WALL BEYOND - _ l—WALL BEYOND 3/4' RECESS FOR PAVERS r GARAGE DOOR 3111 CONC, REW. V 6'xb' z WApaA UP OR FIEER'ESH ON L 6-ML POLY ETHYLENE VAPORBARRIER �* a 0 gLL0 a a I Q r CLEM TWITSMATED iJ 114 '• • ' I� 3 I/!' C. REII'E, W/ IS -II HI - WIAXUA ULLF OR RBERMESH ON —� 6-MIL POLY ETHYLENE VAPOR , a - 3 IR' CONC, REND. W/ WI IU MILI PAVER BASE BARRIER ON UE -r POLY ETHYLENE VAPOR 5 REBAR ON GLEAN TERMITE TREATED FILL FOOTMG a I -0 TREATED FILL BARRIER ON WELL -COMPACTED CLEAN TERMITE TREATED FILL 4' 4' CHAIRS BEYOND z K L 5 REBAR ON CHAIRS EXTEND FOOTING, a' 4' 4' 6' RECESS FOR PAVERS `^ GARAGE STEP-UP UNDER PAVERS U I 0 (2) 1311 ON CHAIRS NON -BEARING f 8C%& /2'•'-0' @)9GARRAGgE DOOR FOOTING SCALE: W-I'-0' PAVER RECESS �1@ ENTRY DOOR SEE MANUF. PRODUCT DETAILS FOR RECUIRED SIZE AND DEPTI z OF RECESS FOR SI TRACK F w VARIES a FINISH FLOOR — (0 5 MBAR SET IN SIMPSON HIGH " i STRENGTH EPDXY W EMBED. MN. (2) 5 REBAR I -STORY w, L (3) 5 MBAR 2-STORY K a. > ` <a OUTSIDE REBAR TO BE �- n c CONTNUOUS a 8 3 I/!' CONC, REINPP, W/ WI MAxWA WWF OR FIBERMESH ON6-MIL - - a POLY ETHYLENE a.``. BARRIER ON LLELL-COMPACTED CLEAN TERMITE TREATED FILL 2'-I' MIN. LAP SLAB AT S. G. D. TYP. RETROFIT FOR 11 SCALE:I'.P.O' A OMITTED DOWELS B REBAR LAP AT FOOTING SCALE: Ill •1'-0 C E: '.I'-0' TIE VERTICAL REBAR TO HOIRIZATIONAL REBAR W/ 10' HOOK GROUTED BOND BEAM VARIES PER ELEv. z as 1 LL CLEANOUT RIECUIRED FOR INSPECTION z L 0'-0' FIN. FLR (0 5 VERT. DOWEL - LAPPED W/ BOND BEAMVERTIC li o AL REBAR (BAR AT COWERS 0 5 MRN _ TO HORIZATION% �.�- REBAR W/ I0' HOOK 4V 25• LAP MIN. z� m s TYP. REBAR LAP HORIZONTAL/ VERTICAL r AT LINTEL CORNERS F REINFORCING A R C H I T E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.a bdesigngro u p.com AA #: 0003325 �IIIIIR II sUBDIV. 7LAKE OAKLANDLOT MODEIIIII. 1452 moo-00 PROJECT#: 02784.000/00011 PAGE: FOUNDATION DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA 3& 10 7/10/18 SCALE: 1/4"=V-0" SHEET DI NOTE: NOTE: SHIM AS NEEDED SHIM AS NEEDED TO PLUMB JAMB. TO PLUMB JAMB. ' ❑ DO NOT EXCEED �' ❑ DO NOT EXCEED 8 CMU BLOCK S CMU BLOCK ' DRYWALL J' DRYWALL WINDOW/DOOR JAMB P.T. Ix4 A �'x4' MIN. Ix4 or Ix2 P.T. NAILER P.T. Ix4 A , IBLO MIN. ACHED LOCKING FASTENER (SEE WINDOW/DOOR JAMB BLOCKING (SEE WINDOW/DOOR JAMB BLOCKING Ix4 or Ix2 P.T. NAILER FASTENER SCHEDULE FOR ATTACHMENT DOOR CASING FASTENER SCHEDULE FOR ATTACHMENT 4 POOR CASING ULE DOOR JAMB / WINDOW SECURE 2nd 2x TO STRUCTURAL OOR JAMB / WINDOW (ATTACHED TO BLOCKING MEMBER w/ (2) 12d NAILS 8' FROM (ATTACHED TO BLOCKING cEm PER MFR'S SPECIFICATIONS EACH END and a 18' O.C. MAX PER MFR'S SPECIFICATIONS) P.T. lx4 or'x4' MIN: SECURE THRU FRAME INTO BLOCK w/ (1) �&' TAPCON (MIN. EMBEDMENT 1 J') WINDOW TO BLOCK (+4" or +%4") WINDOW TO BLOCK (+3") 8' FROM EACH END and a IS' O.C. MAX or DOOR JAMB TO BLOCK (+4" or +%") DOOR JAMB TO BLOCK (+3") (1) DRIVE PIN, 8' FROM EACH END and iv I8 O.C. MAX MIN. SHANK SIZE .145 MIN. HEAD SIZE .300 MIN. EMBEDMENT I' NOTE: NOTE: SHIM AS NEEDED SHIM AS NEEDED P.T. 2x4: TO PLUMB JAMB. TO PLUMB JAMB. SECURE TO BLOCK w/ (1)TAPCON 11 DO NOT EXCEED' ❑ DO NOT EXCEED' (MIN. EMBEDMENT 1 J') 8' FROM EACH 8' CMU BLOCK ENE) and 9 18' O.C. MAX DRYWALL 8' CMU BLOCKDRYWALL ' or (1) DRIVE PIN, 8' FROM EACH END and (SEE WINDOW/DOOR JAMB BLOCKING Ix4 or 1x2 P.T. NAILER P.T. 2x P.T. Ix4 or 'x4' MIN. Ix4 or Ix2 P.T. NAILER 6 18' 0,0. MAX FASTENER SCHEDULE FOR ATTACHMENT DOOR CASING (SEE WINDOW/DOOR JAMB BLOCKING ' 055 (4' WIDE MIN.) MIN, SHANK SIZE .145 FASTENER SCHEDULE FOR ATTACHMENT MIN. HEAD SIZE 300 ' DOOR JAMB / WINDOW SECURE 2nd 2x TO STRUCTURAL DOOR CASING (ATTACHED TO BLOCKING MEMBER w/ (2)12d NAILS S' FROM OOR JAMB / WINDOW MIN. EMBEDMENT 1 SHINGLES OR TILE (PER BLDR) PER MFR'S SPECIFICATIONS EACH END and a 18' O.C. MAX (ATTACHED TO BLOCKING OVER *30 FELT PAPER (OR APPROVED EQUAL) PER MFR'S SPECIFICATIONS) P.T. 2x6: INSTALLED PER SECTION R905 OF THE FBCR, NOTE: SECURE TO BLOCK w/ (2) ' TAPCONS 6TH EDITION (2011) WINDOW TO BLOCK (+1 Y) STRUCTURAL 2x MUST BE ON OUTSIDE 4 SECURED (MIN. EMBEDMENT 1 4') 8' FROM EACH .40 DOOR JAMB TO BLOCK (+1 %") THROUGH NON-STRUCTURAL MEMBER (Ix or �( ' OSB) END and 6 16' O.C. MAX OVER ROOF SHEATHING (TYPE AND ATTACHMENT 4B w/ J' TAPCON MIN. I J' EMBEDMENT INTO BLOCK or METHOD PER 'NAILING SCHEDULE')— scALe: i'°i' 0' (2) DRIVE PINS, 8' FROM EACH END and RE -ENGINEERED ROOF TRUSS 6 15' O.C. MAX EMBEDDED STRAP ATT OR BLOWN -IN INSULATION WINDOW TO BLOCK (+3 %6") MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 (PER PLAN)— (R-VALUE PER ENERGY CALCS) NOTE: DOOR JAMB TO BLOCK (+3 16") MIN. EMBEDMENT 141 SHIM AS NEEDED C4F SCALE: r=r-m' TO PLUMB JAMB. METAL DRIP EDGE 'GYPSUM BOARD OR �, HIGH ❑ DO NOT EXCEED ' P.T. 2x8: 2x6 SUB -BAND-- STRENGTH CEILING BOARD 8' CMU BLOCK SECURE TO BLOCK w/ (2) �(,' TAPCONS VENTED ONC. FILLED U-BLOCK w/' DRYWALL NOTE: (MIN. EMBEDMENT 1 J') 8' FROM EACH ALUMINUM SOFFIT (1) 05 CONTINUOUS REBAR P.T. 2x Ix4 or Ix2 P.T. NAILER SHIM AS NEEDED END and 6 18' O.C. MAX ER PLAN (SEE WINDOW/DOOR JAMB BLOCKING RECAST LINTEL FASTENER SCHEDULE FOR ATTACHMENT �' OSB (4' WIDE MIN.) TO PLUMB JAMB. or WINDOW (PER PLAN), (SIZE AND REINFORCEMENT 6 ❑ DO NOT EXCEED' (2) DRIVE PINS 8' FROM EACH END and ATTACHMENT PER MFR. PER PLAN) DOOR JAMB / WINDOW DOOR CASING 9 IS' O.C. MAX SPECIFICATIONS (ATTACHED TO BLOCKING 8' CMU BLOCK MIN. SHANK SIZE .145 PER MFR'S SPECIFICATIONS' DRYWALL MIN, HEAD SIZE 300 NOTE: P.T. lx4 or I'x4' MIN. Ix4 or Ix2 P.T. NAILER MIN. EMBEDMENT I' STRUCTURAL 2x MUST BE ON OUTSIDE 4 SECURED (SEE WINDOW/DOOR JAMB BLOCKING (4'WIDE MIN.) ALL INSULATION FASTENER SCHEDULE FOR ATTACHMENT (R-VALUE PER ENERGY CALCS) THROUGH NON-STRUCTURAL MEMBER (Ix or �' OSB) SECURE 2nd 2x TO STRUCTURAL DOOR CASING P.T. (2) 2x4: PRECAST OR POURED IN w/ �' TAPCON MIN. 14' EMBEDMENT INTO BLOCK MEMBER w/ (2) 12d NAILS 8' FROM OOR JAMB / WINDOW SECURE TO BLOCK w/ (1)' TAPCON PLACE SILL (PER BLpR> ' GYPSUM WALL BOARD EACH END and a 18' O.C. MAX (ATTACHED TO BLOCKING (MIN. EMBEDMENT 1 J') 8' FROM EACH TEXTURED CEMENTITIOUS U 05 REBAR VERTICALLY IN WINDOW TO BLOCK (+1 1%6 1 PER MFR'S SPECIFICATIONS) ENE) and 9 18' O.C. MAX COATING MIN, (PER ASTM CONC. POURED CELL 15 NOTE: or (IJ DRIVE PIN, 8' FROM EACH ENE) and C926) OVER CM a (LOCATION PER PLAN) DOOR JAMB TO BLOCK (+1 �6) STRUCTURAL 2x MUST BE ON OUTSIDE 4 SECURED 18' O.C. MAX 8' CMU ' P.T. FURRING STRIPS e IV O.C. 4C SCALE: r.r-m' THROUGH NON-STRUCTURAL MEMBER Ox or �6' OSB) MIN. SHANK SIZE .145 w/' TAPCON MIN. 1 4' EMBEDMENT INTO BLOCK MIN. HEAD SIZE 300 OD BASE MIN. EMBEDMENT I' NOTE: WINDOW TO BLOCK (+3 %6") SHIM AS NEEDED 7 P.T. l2) 2x6: ° To PLUMB JAMB. DOOR JAMB TO BLOCK (+3 /6 ) Em ONCRETE SLAB DO NOT EXCEED' 4G SCALE, r=r-o' SECURE TO BLOCK w/ (2)' TAPCONS (SEE FOUNDATION PLAN FOR SIZE (MIN. EMBEDMENT 14') 8' FROM EACH °y • AND REINFORCEMENT) 8' CMU BLOCK END and a 18' O.C. MAX XTERIOR WALL FOOTING' DRYWALL or UPLIFT UP TO 1,175 lb (SEE FOUNDATION PLAN FOR SIZE P.T. 2x lx4 or lx2 P.T. NAILER (2) pRIVE PINS, 8' FROM EACH ENE) and �SILE(5�'TORY K WALL SECTION — HIP ROOF AND REINFORCEMENT) (SEE WINDOW/DOOR JAMB BLOCKING 5IMP50N HT520 w/ (10) I0d NAILS TO TRUSS 4 9 18' O.C. MAX FASTENER SCHEDULE FOR ATTACHMENT P.T. Ix l4 WIDE MIN.) (4) J'X2 J' TAPCONS INTO BOND BEAM -ENGINEERED MIN. SHANK SIZE .145 SCALE: 3/4'�I'-0' DOOR JAMB / WINDOW DOOR CASING (or EQUIVALENT INSTALLED PER MFR'S SPECS TRUSS MIN, HEAD SIZE 300 (ATTACHED TO BLOCKING ONTINUOUS BOND MIN. EMBEDMENT I' BATT INSULATION ADHERED TO CEILING 'GYPSUM BOARD OR HIGH PER MFR'S SPECIFICATIONS :7UPLIFT UP TO 2350 lb BEAM BOARD (R-VALUE PER ENERGY CALCS) cv� TRENGTH CEILING BOARD (2) 5IMP60N HT520 EACH SIDE OF TRUSS w/ NOTE: (10) \V I0d NAILS TO TRUSS 4 (4) J'X2 4' TAPCONS - P.T.(2) 2x8: Em STRUCTURAL 2x MUST BE ON OUTSIDE 4 SECURED INTO BOND BEAM SECURE TO BLOCK w/ (2)' TAPCONS THROUGH NON-STRUCTURAL MEMBER (Ix or Ib' 0.5) (or EQUIVALENT INSTALLED PER MFR'S SPECS)(MIN. EMBEDMENT 1 ') 8' FROM EACH w/' TAPCON MIN I' EMBEDMENT INTO BLOCK END and -s IS' O.C. MAX r- TAPCONS MIN. or OPENING 22' x 30' MIN.Op CASING AT SIDE WINDOW TO BLOCK (+2 %") 2' COVER (2) DRIVE PINS, 8' FROM EACH ENE) and 2` APART 6 18' O.C. MAX ATTIC ACCESS AIR SEAL GASKET BETWEEN DOOR JAMB TO BLOCK (+2 Y4 MIN. SHANK SIZE .145 3 SCALE: Nxs. WOOD CASING 4 GYP. 4D ) TRUSS ANCHOR RETRO—FIT ' MIN. HEAD SIZE 300 BOARD (TYP) SCALE: I=I' °' SCALE: N.Ts. MIN. EMBEDMENT 1 J' A R C H I T E C T S Desi�n p 1 ou inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAx:407-774-4078 www.abdesigngroup.com AA #: 0003325 r �erem omo� E 8 N c0 C O cc SVBDIV.]LAKE OAKLANLOTMODEL: 145XXX00 PROJECT#: 02784.000/00011 PAGE: 1—STORY WALL SECTIONS & NOTES 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA 7/10/18 1�lCALE: 1/4"=1'—O" 1 SHEET D2 A R C H IT E C T S 6 Design Grou 12. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www,a bdes igngro u p.co m AA #: 0003325 �'llllll"I L pmp000000J sUHDIV. 8 LOT: OAKLAND LAKE LOT 11 MODEL: 1452 XXX00-00 PROJECT#: 02784.000/00011 PAGE: SECTIONS/ DETAILS 160 MPH EXP. C ARCHrrECT- STATE OF FLORIDA 7/10/16 SCALE: 1/4"=1'-O" 1 SHEET D 3 NCR o (U 6 EA i' O.G. M TYPICAL VALLEY TRUSS CONNECTION SCALE: 3/4'=I'-0' ECURE 2x4 FLAT TO BLOCK w/ CUT NAILS — c I ECURE 2x6 MIN. TO BLOCK w/ (2)y' x 9' WASHER SE ANCHOR BOLTS w/ 2' B HIG T IN SIMP60N or USP H STRENGTH EPDXY (MIN. 6' EMBEDMENT) a o -- SECURE 2x6 MIN, TO BLOCK w/ (3)Y' x 9' WASHER SE ANCHOR BOLTS w/ 2' T IN SIMPSON or USP - HIGH STREN GTH EPDXY (MIN. 6' EMBEDMENT o � GARAGE DOOR BUCK ATTACHMEN T SCALE: 3/4'=I'-0' PRE-ENGINEERED TRUSS ' GYPSUM BOARD OR ' HIGH STRENGTH CEILING BOARD 2x TOP PLATE GYPSUM WALL BOARD 2x WOODS STUDS a 24' O.C. (SIZE PER PLAN) SECURE BOTTOM PLATE TO SLAB w/ 10d MASONRY NAILS a 32' O.C. MAX CONCRETE SLAB (SEE FOUNDATION PLAN FOR SIZE AND REINFORCEMENT) a - a INTERIOR NON —BEARING WALL WOOD STUDS SCALE: 3/4'4-0' �RE-ENGINEERED TRUSS GYPSUM BOARD OR ° HIGH STRENGTH CEILING BOARD 3 % TOP CHANNEL (25 GAUGE) TOP CHANNEL TO TRUSS w/ DRYWALL SCREWS (EACH TRUSS or 24' O.C. MAX) 'GYPSUM WALL BOARD 3 V METAL STUDS (25 GAUGE) Q 24' O.0 w/ FULL LENGTH LAYER OF 1/2' TYPE GYPSUM WALLBOARD, ATTACHED TO EACH SIDE Q 12' O.C. 3 %$' BOTTOM CHANNEL (25 GAUGE) BOTTOM CHANNEL TO SLAB w/ 10d x I' MIN. MASONRY NAIL w/ WASHER 6 32' O.C. MAX. ONCRETE SLAB (SEE FOUNDATION PLAN FOR SIZE AND REINFORCEMENT) NOTE: STUD GAUGE IS HEIGHT SPECIFIC. CONSULT w/ MANUFACTURER ON STUD HEIGHT LIMITS. INTERIOR NON —BEARING WALL METAL STUDS SCALE: 3/4'=I'-0' ' TEXTURED CEMENTITIOUS U REBAR VERTICALLY IN CONC. POURED COATING MIN, (PER ASTM CELL (SIZE AND LOCATION PER PLAN) C926) OVER GMU 1 CMU BLOCK ATHER STRIP MOLDING AROUND DOOR IPER MANUFACTURER'S SPECIFICATIONS) 2x6 P.T. WOOD STUD SECURED TO FILLED CELL w/ (3)V x S' ANCHOR BOLTS w/ 2' GALVANIZED STEEL TRACK BRACKETS WASHER SET IN 5IMP50N or USP HIGH (BY OTHERS - INSTALLED TO 2x6 P.T. BUCKS STRENGTH EPDXY (MIN. 6' EMBEDMENT) PER MANUFACTURER'S SPECIFICATIONS r rlw. suDe � VERNEAp GARAGE DOOR (BY OTHERS) Boor ALVANIZED STEEL VERTICAL TRACK B SECTION (BY OTHERS - INSTALLED PER SCALE: N.TS, MANUFACTURER'S SPECIFICATIONS) A R C H I T E C T S Design r 10U Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 STJBDIV. 8c LOT: OAKLAND LAKE LOT 11 MODEL: 1452 M00-00 PROJECT#: 02784.000/00011 PAGE: SECTIONS/ DETAILS 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA 0- A 7/10/16 SCALE: 1/4"=1'-0" 1 SHEET D 4 PREFORMED CONTROL JOINT FLANGE OF CONTROL JOINTS TO BE WIRE TIED TO LATH'@ 9" O.C. MAX (VERT.). NOTE: DO NOT FASTEN CONTROL JOINT TO WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ %" LEG MAY BE USED TO TEMP. SECURE CONTROL JOINT DURING INSTALLATION TEMPORARY STAPLES_TO_BE REMOVED AFTER INSTALLATION FASTENERS TO BE SPACED 6 1" O.C. MAX VERTICALLY LATH SHALL NOT BE CONTINUOUS THROUGH CONTROL JOINTS BUT SHALL BE STOPPED AND TIED AT EACH SIDE. PER ASTM C1063 1.10.1.4 NOTE: 1. FASTENERS FOR LATH TO BE NAILS OR STAPLES IN COMPLIANCE W/ ASTM C1063 2. WIRE TIES TO BE (NO. IS) 0.0415" WIRE 3. BLOCKING SHOWN MAY BE IN ADDITION TO WALL STUDS REQUIRED PER PLAN CUT TWO PIECES OF FORM FLASH 1 APPROX. 6" LONGER THAN THE WIDTH OF PIPE OPENING LOCTITE SPRAY ADHESIVE DIRECTLY—\ TO OSB AROUND PENETRATION 1" OR LESS PIPE PENETRATION STARTING WITH THE BOTTOM HALF OF THE PIPE, REMOVE THE RELEASE LINER AND FOLD THE FORM FLASH 1 IN HALF (LENGTH WISE WITH ADHESIVE TO THE EXTERIOR) ALIGN THE PROTECTO FORM FLASH I WITH THE CENTER OF THE PIPE, ADHERE FORM FLASH 1 TO THE BOTTOM HALF OF THE PIPE AND WRAP AROUND THE PIPE. PER FBC R103.1.1 3A EXTERIOR LATHING AND PLASTERING EXTERIOR USE OF PORTLAND CEMENT PLASTER SHALL COMPLY WITH THE APPLICATION REQUIREMENTS OF ASTM C 926-12A. INSTALLATION OF EXTERIOR LATHING AND FRAMING SHALL COMPLY WITH ASTM C 1063-12A STEP I INSTALL FASTENERS (CLIPS, STRAPS, STAPLES) AS REQUIRED TO SECURE PIPE/ WIRE TO FRAMING \,\PIPE PENETRATION DETAIL J SCALE: M.T.S. G�' TO i' AP MIN. 6' TO 6' 6' TO 6' a" THICK, 3 COAT CEMENT PLASTER WRB LAYER #2, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) APPROVED METAL LATH FASTENED '@1" (VERY) O.C. MAX AT SUPPORTS WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING 7-PROTECTED FLASH TAPE BEHIND CONTROL JOINT PROVIDE 2X4 BLOCKING PLACED FLAT MAX. 6" TO V FROM CONTROL JOINT WHEN CONTROL JOINT FALLS ON STRUCTURAL STUD \,\TYPE "M" CONTROL JOINT 1 BCALE: N.tb. NOTE: APPLY SEALANT AT I'M" CONTROL JOINT END TO END CONDITIONS USE FINGERS TO MOLD THE REMAINING HALF OF THE FORM FLASH 1 TO THE SHEATHING, MAKING SURE THE FORM FLASH 1 IS TIGHT TO THE PIPE AND TO THE \ SHEATHING WITH MINIMAL AIR POCKETS OR BUBBLES. STEP 2 SECTION TAKE SECOND PIECE OF FORM FLASH I AND APPLY IT TO THE TOP HALF OF THE PIPE IN THE SAME MANNER, MAKING SURE THE OVERLAP AREAS ARE PRESSED DOWN TIGHT TO THE PIPE AND SHEATHING. TAPE WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING WRB LAYER 02, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) METAL LATH PROTECTO FORM FLASH I CONFORMABLE AIR/VAPOR BARRIER TAPE DIRECTLY TO SHEATHING LOCTITE SPRAY ADHESIVE DIRECTLY TO OSB AROUND PENETRATION ELASTOMERIC COATING (OR APPROVED EQUAL) OVER STUCCO/ C,V. FINISH (SEE TYP WALL SECTION) NOTE: SIDE LAPS OF METAL PLASTER BASES SHALL BE SECURED TO FRAMING MEMBERS. THEY SHALL BE TIED BETWEEN SUPPORTS WITH 0.0415-IN. (1.21-MM) WIRE AT INTERVALS NOT MORE THAN 9" (229-MM). AS PER ASTM C1063 1.0.1. NOTE: FOR REPAIR OF TEARS IN WRB LAYERS, TEARS MAY BE PATCHED PEEL $ STICK WOOD STU y SHEATHI WRB #1 TAPED T( SHEATHING w/ Wf #2 OVER TOP. WF 02 TO BE LAPPE_ VERTICALLY 6" MIN. STUCCO OVER METAL LATH. METAL LATH TO HAVE I" VERTICAL LAP MIN, HORIZONTAL LATH & PAPER DETAIL SIDING FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) \'APER LAP ALE: WOOD SHEATHING WATER RESISTIVE BARRIER LAP SIDING (PER BUILDER) MINIMUM LAP (PER MANUF. SPECS) WEEP SCREED STARTER STRIP (PER MANUF. SPECS) MINIMUM CLEARANCE (PER MANUF. SPECS) 5"Xl" CONTINUOUS GALV. METAL STEP FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE - DO NOT NAIL ADHERED SHINGLES TRIMMED TO COVER FLASHING STRIP "L" FLASHING 4 SCALE: RTs. - NOTE: APPROVED BUILDING WRAP SHALL BE LAPPED A MINIMUM OF 6" a VERTICAL LAPS (ROLL ENDS) 6" 6 HORIZONTAL LAPS. LATH VERTICAL LAP TO BE I° METAL LATH TAPE WRB LAYER 01, STUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING I' MIN LATH LAP, 4' OVER ALL LAP VERTICAL LATH & PAPER DETAIL 8" THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER #2, FORTIF15ER BUILDING PAPER (OR APPROVED EQUAL) TAPE WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) DIRECTLY TO SHEATHING LEGEND DRAINAGE PLANE (WRB LAYER #I, STUCCOWRAP OR :x APPROVED EQUAL) �I WRB LAYER 12 z (FORTIFIBER z BUILDING PAPER OR E APPROVED EQUAL) r�. STUCCO SHEATHING METAL LATH X X X X STUCCO _° -] a� WOOD SHEATHING \\\\/22=- SELF-ADHESIVE FLASHING NOTE: METAL LATH: LATH TO BE PER FBC R103.1.1 / ASTM C-541-091 MIN, 2.5 LBS, PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) WRB: WATER RESISTIVE BARRIER A R C H I T E C T S Grousi n LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.a bd esigngro u p.co m AA #: 0003325 umnun ��somevcomm� E 8 0 SUBDIV.7LAKE OAKLANLOT MODEL: 1452 moo—oo PROJECT#: 02784.000/00011 PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA DATE: 7 /1 O /18 SALE: 1/4"=1'- 0" SHE�E��T� VV HAI TEXTURED CEMENTITIOUS WRB LAYER #1, STUCCOWRAP (OR APPROVED - COATING X EQUAL) WOOD SHEATHING WRB LAYER 12, FORTIFIBER BUILDING — s" THICK, 3 COAT PAPER (OR APPROVED EQUAL) ;x VENT CAP 15 TO BE SET IN CONTINUOUS BED OF CEMENT PLASTER WRB LAYER #1, 5TUCCOWRAP (OR APPROVED SEALANT. PREMANUF. DRYER VENT CAP EQUAL) TAPED DIRECTLY t0 SHEATHING ONE -PRICE HOODED VENT ATTACHED PER MANUF. (SET IN CONT. SEALANT) LAP LAYERS OF BUILDING WRAP OVER SPECIFICATIONS - STEP FLASHING NAILING FLANGE, STOP WRB APPROX. APPLY SEALANT AT PERIMETER OF OVERLAPS KICKOUT 1 %" ABOVE SHINGLES X! NON -MOVABLE FRAME AND STUCCO ON ALL I Ell DIVERTER I" MIN. <y =;. X; SEALANT ALL SIDES SELF -ADHERING FLASHING 51DE5,y SEALANT JOINTS ALL AROUND a" THICK, 3 COAT CEMENT PLASTER STEP FLASHING METAL LATH 6B DRYER VENT BLOCK DRYFLEKT KICKOUT DIVERTER WRB LAYER 02, FORTIF15ER BUILDING SCALE! KT.6. NO PAPER (OR APPROVED EQUAL) BUILDING PAPER Sao 6A DRYER VENT FRAME) OVER "QUICK FLASH" FELT UNDERLAYMENT p SCALE: N.TS, PIPE THROUGH WALL PER FBC R103.1.1 SHINGLE ROOFING EXTERIOR LATHING AND PLASTERING DRIP EDGE: OVERLAP 3" FASCIA WRAP EXTERIOR USE OF PORTLAND CEMENT PLASTER SHALL EXTEND 1/2" BELOW BUILDING PAPER COMPLY WITH THE APPLICATION REQUIREMENTS OF SHEATHING, MECHANICALLY UNDER "QUICK FLASH" A5TM C 926-12A. FASTEN 4" O.C. MAX. A VENT PENETRATION INSTALLATION OF EXTERIOR LATHING AND FRAMING ti 3LALE: N.TB. SHALL COMPLY WITH A5TM C 1063-12A WOOD SHEATHING WRB LAYER 02, FORTIF15ER LEGEND WOOD WRB LAYER #1, BUILDING PAPER (OR DRAINAGE PLANE NOTE: CONSTRUCTION 5TUCCOWRAP (OR APPROVED EQUAL) (WRB LAYER 01, 5TUCCOWRAP INSTALL KICKOUT FLASHING KICKOUT DETAIL WOOD APPROVED EQUAL) METAL LATH OR APPROVED EQUAL AT BOTTOM OF ROOF 8 WALL 5 s :r�T�. SHEATHING WRB LAYER #2, WOOD S/8" TEXTURED FIN15H 6 WOOD WRB LAYER 02 INTERSECTIONS' FORTIFIBER CONSTRUCTION FASTEN TO WOOD STRUCTURAL (FORTIFIBER BUILDING 8 CMU PAPER BUILDING PAPER (OR MEMBER a I" O.C. MAX OR APPROVED EQUAL) APPROVED EQUAL) 5 AREA TO RECEIVE I COAT OF 5HER-CRETE — �„ - 0, /a TO /Si MID -WALL METAL LATH X X X X FLEXIBLE CONCRETE WATERPROOFER or 1 $THICK, T\ SCRATCH COAT PRIOR t0 ELEC. METER WOOD FRAMED PLASTER 6" WIDE STRIP SELF STUCCO a INSTALLATION WALL %s" TO I/8" MID -WALL ADHERING FLASHING, CLEAN WOOD SHEATHING WEEP SCREED MA50NRY BEFORE APPLYING SELF-ADHESIVE FLASHING (PER 3/WAU — 6" SELF -ADHERING FLASHING TEXTURED FIN15H 6 MA5ONRY HORIZONTAL WEEP SCREED HORIZONTAL WEEP SCREED NOTE: - FRAME TO FRAME) F METAL LATH: LATH TO BE PER FBG R703.i.1 / A5TM AME (FRAME TO BLOCK C. METER FIELD VERIFY y EC. — ! 1-i SCALE. N.T.S. � D SCALE: N.TS. C-S4 I-0g, MIN, 2.5 LBS. PER 5Q. YARD (UTILITY OR LOCATION NOTE: PROTECTED FLASH TAPE BEHIND WEEP 5CREED 8 APPLY SEALANT AT WEEP 5CREED END TO END JOINTS NOMINAL LATH DOES NOT MEET SPECIFICATIONS) ELEC. METER FIELD VERIFY LOCATION CUT ENOUGH PROTECTO FORM SEALANT ON TOP 4 SIDES ONLY—/— FLASH 1 PIECES t0 COVER BOX 4" NOTE: ATTACH PER PAST EACH SIDE. STARTING AT THE MANUF. SPECIFICATIONS BOTTOM OF THE BOX, REMOVE RELEASE LINER AND APPLY MAKE AN "X" CUT THROUGH PUSH THE PROTECTO FORM CAVITY TOBE FILLED WITH RIGI D PROTECTO FORM FLASH 1 IN A THE PROTECTO FORM FLASH I FLASH I INTO THE OPENING POLYMERIC 15OCYANATE-POLY5LEND SINGLE FASHION TO COMPLETELY IN THE CENTER OF THE BOX AND ADHERE TO THE FOAM ("GREAT STUFF" OR SIMILAR) COVER THE BOX, OR OUTLET OPENING INTERIOR OF THE BOX, EXTENDING TO NO CLOSER WOOD SHEATHING THAN 1" TO CORNER. STEP 1 STEP 2 STEP 3 WRB LAYER #I, 5TUCCOWRAP APPLY SEALANT AT TOP 8 (OR APPROVED EQUAL) EL,45TOMERIC COATING SIDES OF ELEC. METER BOX PROTECTO FORM FLASH I (OR APPROVED EQUAL) AFTER STUCCO INSTALLATION SELF ADHERING FLASHING APPLY E-Z BEAD 0 .0.0.0 • • OVER STUCCO/ C.V. FINISH FLASH OPENING WITH PROTECTO FORM FLASH 1 APPLY 60 MIN GRADE "D" FELT (OR APPROVED EQUAL) (SEE TYPICAL WALL SELF ADHERING FLASHING PER FLASHING OVER SELF -ADHERING FLASHING OVER 60 MIN GRADE "D" SECTION) ELECTRICAL CONDUIT METHOD AS DESCRIBED IN DETAIL 3 OF WAI OVER APROVED HOUSEWRAP FELT -PROVIDE SEALANT0. METAL LATH PENETRATION "PIPE PENETRATION DETAIL" AT ALL JOINTS AND • . • . • . ....... 8 SCALE, ".T�. APPLY 1 COAT OF 5HER-CRETE FLEXIBLE CONCRETE WRB LAYER #2 FORTIFIBER INTERSECTIONS EXTERIOR WATERPROOFER 2" LARGER THAN THE ELEC. METER CAN BUILDING PAPER (OR ELECTRICAL RECEPTACLE OR METER CAN COMBO OR METER CAN AND D 15CONNECt APPROVED EQUAL) STEP 4 STEP 5 KTST) STEP 6 A R C H IT E C T S 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-7744078 www.abdesigngroup.com AA #: 0003325 �I"IIII"I L mmoom�moo� E 8 0 E O L L SUHDIV. 8a LOT: OAKLAND LAKE LOT 11 MODEL: 1452 xxx00-00 PROJECT#: 02784.000/00011 PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA P\-1® DATE: '�/10/18 SCALE: 1 /4"=1' - O" VV A2 WOOD SHEATHING WOOD CONSTRUCTION %" HAT CHANNEL W/ V TYPE "X" DRYWALL WOOD SHEATHING WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) $" THICK, 3 COAT — CEMENT PLASTER WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) AMIGO AM66-UPWC-100 CUSTOM CASING BEAD (OR APPROVED EQUAL) DO NOT CAULK OR SEAL GAP WRB LAYER 11, STUCCOWRAP (OR APPROVED EQUAL) WRB LAYER 12, FORTIP15ER BUILDING PAPER (OR APPROVED EQUAL) 8" THICK, 3 COAT CEMENT PLASTER AM66-WFWC-780 CUSTOM CASING BEAD (OR APPROVED EQUAL) WRB LAYER #1, STUCCOWRAP (OR APPROVED EQUAL) WRB LAYER 02, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) X'll \I� WRAPPED pHEREING FLASHING CORNER OF CANTILEVER AMICO AM66-WFWC-150 CUSTOM CASING BEAD (OR APPROVED EQUAL) (W/OPT. WEEPS) CASING BEAD DETAIL @ CANT. FINISH LAYER (2 LAYER PEEL 8 STICK) 6' PEEL 4 STICK ,a DRIP EDGE TO DECK I y"Xl %" P.T. OR SIMULATED WOOD (TREX) FILLER (OR APPROVED EQUAL), CONTINUOUS WATER PROOFING Ist LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO CANTILEVER 6' PEEL 4 STICK Q DRIP EDGE TO DECK SUB FLOOR FULL SHEETS OF PEEL 4 STICK I Y2"X1 Y4" P.T.OR SIMULATED WOOD (TREX) FILLER (OR APPROVED EQUAL), CONTINUOUS Y4" GAP FOR BACKER ROD 4 SEALANT $" THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) CASING BEAD VINYL (OR APPROVED EQUAL) BEAD VINYL (OR APPROVED EQUAL) CASING BEAD r=+COMPONENTS PULLED —� 1 APART FOR CLARITY LEGEND DRAINAGE PLANE (WRB LAYER 11, STUCCOWRAP OR APPROVED EQUAL WRB LAYER #2 (FORTIFIBER BUILDING PAPER OR APPROVED EQUAL) METAL LATH X X X X STUCCO f . - WOOD SHEATHING SELF-ADHESIVE FLASHING VINYL (OR APPROVED. EQUAL) CASING BEAD 5/8' TYPE "X' DRYWALL W/TEXTURED 4 PAINTED FINISH $" THICK, 3 COAT CEMENT PLASTER VINYL (OR APPROVED EQUAL) CORNER BEAD VINYL (OR APPROVED EQUAL) CASING BEAD 3" X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, Y" MIN. SPACE FROM DRIP FACE TO TREX Y" GAP FOR BACKER ROD 8 SEALANT NOTE: METAL LATH: LATH TO BE PER FBC R103.7.1 / ASTM C-541-09, MIN. 25 LBS. PER SQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) WOOD CONSTRUCTION WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER #2 8" THICK, 3 COAT CEMENT PLASTER METAL LATH WOOD SHEATHING HEADER/BEAM VINYL CORP. (OR APPROVED EQUAL) 4" P051TIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) A DRIP EDGE INSTALLATION 1 1 Li SCALE: NT.S. y" GAP FOR BACKEf;� ROD 4 SEALANT VINYL (OR APPROVED EQUAL) CASING BEAD WATER PROOFING lst LAYER (2 LAYER PEEL 4 STICK) PEEL 4 STICK DECK MEMBRANE, EXTEND OVER DRIP EDGE SUB FLOOR "�3" X 3" 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT,y" MIN. SPACE FROM DRIP FACE TO TREX MODIFIED 90- VINYL (OR APPROVED EQUAL) CASING BEAD 1 Y2'XI Y' P.T. OR SIMULATED WOOD (TREX) WATER PROOFING Ist LAYER (2 LAYER FILLER (OR APPROVED EQUAL), CONTINUOUS PEEL 8 STICK) WRAPPED FROM BALCONY Y4' GAP FOR SEALANT 4 DECK TO CANTILEVER OPT. BACKER ROD $" THICK, 3 COAT CEMENT PLASTER METAL LATH WOOD SHEATHING WEATHER RESISTIVE BARRIER 11 VINYL (OR APPROVED EQUAL) CASING BEAD WEATHER RESISTIVE BARRIER 11 WEATHER RESISTIVE BARRIER 02 I ***COMPONENTS PULLED APART FOR CLARITY WEATHER RESISTIVE BARRIER 02 3" THICK 3 COAT CEMENT 4" POSITIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) BALCONY DRIP EDGE INSTALLATION a PLASTER VINYL (OR APPROVED EQUAL) CASING BEAD VINYL (OR APPROVED EQUAL) BEAD VINYL (OR APPROVED EQUAL) CASING BEAD NOTE: SET RAILING LAG BOLT ATTACHNMENTS IN SEALANT, WHERE APPLICABLE 2x FRAMING MEMBER $" THICK, 3 COAT CEMENT PLASTER CORNER BEAD FASTENED TO SHEATHING a I' O.C. MAX. WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) WOOD SHEATHING METAL LATH WRB LAYER #2, FORTIFIBER BUILDING PAPER (OR APPROVED EQUAL) @4L,�NER BEAD @FRAME NTs. CORNER BEAD (FASTENER 4 SPACING ia 7" O.C.) CMU %" THICK, 3 COAT CEMENT PLASTER APPLIED DIRECTLY TO CONCRETE MASONRY UNIT SCORNER BEAD @ BLOCK 1(rD 5CALE: NTS. COLUMN SHEATHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER 12 6' SELF ADHERING & FLASHING PEEL 4 STICK 1 y2"x3" "L' FLASHING FULLY EMBEDDED IN ROOF CEMENT I y' X 3' 26 GA. GALV. METAL DRIP EDGE SET IN FULL BED OF SEALANT, Y2" MIN. SPACE FROM DRIP FACE TO TREX WEATHER RESISTIVE BARRIER #i WEATHER RESISTIVE BARRIER #2 EXTERIOR COLUMN COLUMN SHEATHING 6' SELF ADHERING 4 FLASHING / 1 YI2°x3' 'L" FLASHING FULLY EMBEDDED IN ROOF CEMENT Y" X 3" 26 GA. GALV. METAL DRIP EDGE T SET IN FULL BED OF SEALANT, F MIN. SPACE FROM DRIP FACE TO TREX ON ALL 4 SIDES OF COLUMN VINYL (OR APPROVED EQUAL) CASING BEAD WATER PROOFING Ist LAYER (2 LAYER PEEL 4 STICK) WRAPPED FROM BALCONY DECK TO CANTILEVER 8' THICK, 3 COAT CEMENT PLASTER METAL LATH WOOD SHEATHING WEATHER RESISTIVE BARRIER #1 WEATHER RESISTIVE BARRIER 02 4" POSITIVE DRAIN WEEP SCREED NO GAP IN FIELD (SHOWN FOR CLARIFICATION OF SEPARATE ACCESSORIES ONLY) BALCONY DRIP EDGE INSTALLATION @ COLUMN W/ 'T' FLASHING A R C H I T E C T S Design p 1 QU Mc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.a bdesigngro u p.co m AA #: 0003325 E g 0 SUBDIV. & LOT: OAKLAND LAKE LOT it MODEL: 1452 XXX00-00 PROJECT#: 02784.000/00011 PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA DATE: 7 /10 /18 SCALE: 1 /4"=1' — 0" V V A3 WOOD SHEATHING WOOD SHEATHING WRB LAYER #1, STUCCOWRAP WRB LAYER #I, STUCCOWRAP (OR APPROVED EQUAL) (OR APPROVED EQUAL) 7" FORTIF15ER s CHICK, 3 COAT CEMENT WRB LAYER 12, FORTIFIBER WRB LAYER #1, STUCCOWRAP WRB LAYER 12, WOOD SHEATHING PLASTER BUILDING PAPER y: GAP TTP BUILDING PAPER (OR (OR APPROVED EQUAL) 1X TRIM MEMBER STUCCO `AgeEA° METAL LATH O TRIM APPROVED EQUAL) WOOD SHEATHING (OR APPROVED EQUAL) WRB LAYER #1 STUCCOWRAP TO SIDING TRANSITION WRB LAYER #2, FORTIFIBER METAL LATH ' WRB LAYER #2, FORTIFIBER METAL LATH x (OR APPROVED EQUAL) SIDING BUILDING PAPER $" THICK, 3 COAT BUILDING PAPER (OR $" THICK, 3 COAT CEMENT WRB LAYER #2, FORTIFIBER (OR APPROVED EQUAL) CEMENT PLASTER APPROVED EQUAL) PLASTER BUILDING PAPER WOOD SHEATHING 6"SELF-ADHERING METAL LATH VINYL (OR APPROVED EQUAL) (OR APPROVED EQUAL) FLASHING �° CHICK, 3 COAT ANGLED CASING BEAD METAL LATH \� (EXPLODED $ (EXPLODED 711 . DRIP CAP VIEW FOR CEMENT PLASTER 6 SELF -ADHERING FLASHING viEw �oR $ THICK, 3 COAT - " :: CLARITY) DRIP CAP cLAR�TY) CEMENT PLASTER WINDOW FLANGE WINDOW FLANGE WRB LAYER 111, STUCCOWRAP # WRB LAYER #1, STUCCOWRAP WRB LAYER 1, STUCCOWRAP (OR APPROVED EQUAL) (OR APPROVED EQUAL) (OR APPROVED EQUAL) VINYL (OR APPROVED EQUAL) ANGLED # CASING BEAD WRB LAYER 1, STUCCOWRAP WRB LAYER #2, FORTIFIBER BUILDING (OR APPROVED EQUAL) CASING BEAD PAPER (OR APPROVED EQUAL) WRB LAYER #2, FORTIF15ER BUILDING 6" SELF ADHERING METAL LATH PAPER (OR APPROVED EQUAL) FLASHING OR PEEL 4 STICK 8" THICK, 3 COAT METAL LATH SIDING TO STUCCO CEMENT PLASTER $" THICK, 3 coAt� CASING BEAD 6" SELF -ADHERING L__— CEMENT PLASTER 1� SCALE:NTs. rcrzoss-sECTioN� FLASHING 6"5ELF-ADHERING DRIP CAP FLASHING WOOD SHEATHING WINDOW FLANGE DRIP CAP CASING BEAD @ WINDOW CASING BEAD @ WINDOW WINDOW FLANGE METAL LATH FRAME, NO BAND 13B SCALE: FRAME, W BAND WRB LAYER #1 STUCCOWRAP 13A SC4IE:NTB. (OR APPROVED EQUAL) WOOD SHEATHING LEGEND WRB LAYER 02, FORTIF15ER BUILDING WRB LAYER #1, STUCCOWRAP WOOD CONSTRUCTION BEYOND PAPER (OR APPROVED EQUAL) (OR APPROVED EQUAL) WOOD SHEATHING DRAINAGE PLANE #; WRB LAYER 02, FORTIF15ER (WRB LAYER #1, STUCCOWRAP $° THICK, 3 COAT '� BUILDING PAPER WEATHER RESISTIVE BARRIER 11 OR APPROVED EQUAL) CEMENT PLASTER WEATHER RESISTIVE BARRIER #2 6" SELF -ADHERING FLASHING (OR APPROVED EQUAL) %6 X IY LAP 5101NG W/6 REVEAL WRB LAYER #2 VINYL (OR APPROVED EQUAL) I METAL LATH WEATHER RESISTIVE BARRIER #1 (FORTIFIBER BUILDING PAPER ANGLED CASING BEAD $" THICK, 3 COAT CEMENT (0SELF-ADHERING FLASHING WEATHER RESISTIVE BARRIER #2 OR APPROVED EQUAL) _ (EXPLODED PLASTER STARTER STRIP PER STARTER STRIP PER METAL LATH X X X X VINYL (OR APPROVED EQUAL) VIEW �oR MANUFACTURER'S INSTALLATION _ MANUFACTURER'S INSTALLATION STUCCO CASING BEAD CLARITY INSTRUCTIONS INSTRUCTIONS WOOD SHEATHING DO NOT CAULK OR SEAL OPENING 6" SELF -ADHERING FLASHING SELF-ADHESIVE FLASHING CASING BEAD @RAISED GALVD METAL "Z" FLASHING — GALV'D METAL "Z" FLASHING BAND (FRAME) 1 J SCALE: KTA Mt DO NOT CAULK OR SEAL OPENING NOTE: STUCCO CASING BEAD " METAL LATH. LATH TO BE PER FBC RI / ASTM C-041-091 MIN. 2.5 LBS. PER 50. YARD (UTILITY OR GALV'D METAL "Z" FLASHING NOMINAL LATH DOES NOT MEET SPECIFICATIONS) SIDING TO STUCCO 6 @ BLOCK TO FRAME TRANSITION STUCCO CASING BEAD SCALE: KT.S. 8" THICK, 3 COAT CEMENT PLASTER $" THICK, 3 COAT CEMENT WOOD CONSTRUCTION BEYOND PLASTER 6" SELF -ADHERING FLASHING SEALANT =TO IN BEAD METAL LATH METAL LATH F TYf- WOOD SHEATHING TO WINDOW SEALANT WEATHER RESISTIVE BARRIER #1 WRB LAYER #2 FORTIFIBER BUILDING WEATHER RESISTIVE BARRIER #1 t0 LAP WINDOW FRAME PAPER (OR APPROVED EQUAL) WEATHER RESISTIVE BARRIER 112 6" MIN. ABOVE TOP OF "Z" FLASHING WOOD SHEATHING WRB LAYER 02, FORTIFIBER %" X I/4" LAP SIDING W/6 REVEALS Q WEATHER RESISTIVE BARRIER #1 — WINDOW FRAME BUILDING PAPER 6" SELF -ADHERING FLASHING z i WEATHER RESISTIVE BARRIER #2 TV (OR APPROVED EQUAL) GALVD METAL 7' FLASHING WRB LAYER #I STUCCOWRAP '� — E-Z BEAD VINYL (OR STARTER STRIP PER MANUFACTURER'S DO NOT CAULK OR SEAL OPENING INSTALLATION INSTRUCTIONS (OR APPROVED EQUAL) APPROVED EQUAL) CASING WEATHER RESISTIVE BARRIER #1 TO LAP 6" WIDE PEEL 4 STICK \ (W/%$" FLEXIBLE PVC BACKER DO NOT SEAL OPENING (o" MIN. ABOVE TOP OF "Z" FLASHING WINDOW FLANGE OVER FLANGE ROD INCLUDED) 2X FRAMING MEMBERL E-Z BEAD VINYL 2X FRAMING WRB LAYER #1, STUCCOWRAP GALVD METAL "Z" FLASHING (OR APPROVED EQUAL) CASING (OR APPROVED EQUAL), 6" SELF -ADHERING FLASHING BUILDING WRAP E-Z BEAD VINYL (W/%$" FLEXIBLE PVC BACKER ROD MEMBER WRAPPED AROUND FRAMING (OR APPROVED EQUAL) CASING - INCLUDED) MEMBER / (W/%s" FLEXIBLE PVG BACKER ROD) WEATHER RESISTIVE BARRIER #1 6" SELF ADHERING FLASHING E-Z BEAD VINYL (OR APPROVED EQUAL) 'APPLY FULL BED OF WOOD SHEATHING 6" SELF -ADHERING FLASHING CASING lW/%8" FLEXIBLE PVC BACKER SEALANT BETWEEN %g" THICK, 3 COAT CEMENT PLASTER ROD) FLANGE 4 BUILDING WRAP DETAIL EXPLODED FOR 1 WEATHER RESISTIVE BARRIER # WEATHER RESISTIVE BARRIER #2 CLARITY WEATHER RESISTIVE BARRIER #2 SIDING TO STUCCO EZ BEAD WINDOW CASING Cap FRAME TO FRAME TRANSITION 17 SCALE:NTB. 6 SCALE: N,TS. A R C H I T E C T S rDesign 10U Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 �"IIII"II om0a0ovov� E 8 E f r STJBDIV. 7LAKjE OAKLANDLOT MO DEL: 1452 moo-oo PROJECT#: 02784.000/00011 PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCH rI STATE OF FLORIDA 3& 1 7/10/16 SCALE: 1/4"=1'—O" 1 SHE�ET� �� V V AA CUT HOUSEWRAP AT 450 ANGLE MODIFIED "I' CUT IN HOUSEWRAP LINE OF WINDOW OPENING APPROVED HOUSEWRAP OVER SHEATHING OVER WD STUD WALL STEP I WINDOW FLASHING INSTALLATION DETAILS (FULL WRAP) g18 LE: scAKT (FRAME) APPLY 061 H2U (OR EQUAL) SEALANT WINDOW/GMU JOINT. FLUID APPLIED FLASHING (LANGO WHITE -SEAL RC-865 OR EQUAL). SLOPE SILL TO EXTERIOR TEMPORARILY I=OLD-UP SECURE HOUSEWRAP (0 " ".P UNDER) at HEA FOLD HOUSEWRA IN AT JAMBS 4 51L SLOPE SILL R.O. TI EXTERIO INSTALL (o" SELF -ADHERING FLASHING OVER NAILING FLANGE AT JAMBS EXTEND FLASHING MIN III BELOW SILL FLEXIBLE FLASHING DO NOT SEAL BOTTOM FIN ALIGN FLEXIBLE SELF -ADHERING 45HING W/ INT. EDGE OF SILL R.O. MECHANICALLY FASTEN FANNED EDGES. (CAP NAILS, STAPLES) STEP 2 INSTALL SELF -ADHERING FLEXIBLE FLASHING AS THE FLASHING AT THE SILL 01Lif V NOTE: 1. IT IS THE CONTACTORS RESPONSIBILTY TO VERIFY THE COMPATIBILITY OF ALL PRODUCTS INCLUDING HOUSEWRAP, SEALANTS 4 SELF -ADHERING FLASHING MATERIALS USED DURING CONSTRUCTION. 2. INSTALL ALL MATERIALS PER MANUFACTURERS WRITTEN SPECIFICATIONS 4 WARRANTY REQUIREMENTS. WARNING: SEALANTS AND SELF ADHERED FLASHING MAY REACT ADVERSELY IF NOT COMPATIBLE. NOTE: SEAL INTERIOR PERIMETER OF WINDOW WITH SEALANT (o" SELF -ADHERING c OVER VINYL HEAD IG (WITH END DAMS) NAILING FLANGE EXTEND SELF -ADHERING FLASHING 1" MIN BEYOND JAMB FLASHING INSTALL VINYL DRIP CAP APPLY 3/a' NOM. CONTINUOUS BEAD OF SEALANT AT JAMBS AND HEAD or APPLY TO BACK OF WINDOW NAILING FLANGE IN LINE W/ PRE -PUNCHED HOLES OR SLOTS. SUPER STRETCH BUTYL FLASHING STEP 3 L—gl' VERT. END DAMS REQ'D. AT EACH ENID OF SILL N MIN. TEXTURED :EMENTITIOUS COATING )VER BLOCK JSEWRAP DOWN 8 DIAGONAL CUT 4 HEAD OF WINDOW MIN. TEXTURED EMENTITIOUS COATING VER BLOCK STEP 4 STEP 8 INSTALL A SILT. DAM OVER THE BUILDING WRAP AT THE BACK OR THE SILL AND THEN INSTALL THE SELF -ADHERING STRETCHABLE FLASHING 4 APPLY SEALANT AT ENDS OF SILL DAM INSTALL WINDOW PLL LEVEL AND SQUARE f MANUFACTURERS WR11 INSTRUCTII APPLY FLASHING c INSTALL 6" WIDE BACKED PLEX15LI MATERIAL OVER DRIP (PROTECTO-WRA OR APPROV ,j;va l' MIN. TEXTURED �EMENTITIOUS COATING �VERFRAME STUCCO OVER BLOCK STUCCO OVER BLOCK STUCCO OVER FRAME (MIN. THICKNESS e") (MIN. THICKNESS") (MIN. THICKNESS e") SIDING LOOK ORLANDO/TAMPA ORLANDO/TAMPA S. FLORIDA S. FLORIDA S. FLORIDA "MINIMUM STUCCO THICKNESS 1 e7 BCdLE NTA STEP 5 I A A V 31' MIN. TEXTURED �EMENTITIOUS COATING �)VERFRAME STUCCO OVER FRAME (MIN. THICKNESS e") SIDING LOOK S. FLORIDA A R C H I T E C T S foul 1 ou Inc. 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX:407-774-4078 www.abdesigngroup.com AA #: 0003325 �IIIIYII�I E 8 N E 0 C co SUBDIV. 7LAKjE OAKLANDLOT MODEL: 1452 XXX00-00 PROJECT,: 02784.000/00011 PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHITECT: STATE OF FLORIDA 7/10/18 SgALE: 1/4"=1'-O" 1 SHEET VV5