Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST FORMSCANNED ����00o Planning & Development Sefv1cVC18C0U Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 RECEIVED Phone: 772-462-2165 Fax: 772-462-6443 MAY 1.5 2019 BLOWER DOOR TEST FORM Permitting Department House Infiltration Test Certification St. Lucie Counter Prescriptive and Performance Method Date} 5 / 14 / 2019 Permit #: 11S019- W0 g Conn actor: Homecrete Homes Job ddress: 9502 Poinciana Ct, Fort Pierce, FL 34951 Conk ruction: (x )'New Construction — Complete ( ) Existing —After Addition Hou b Infiltration Test Results SLC Climate Zone 2 CFM (50) = 890 Test Date: 5 / 10 12019 Volu i ne = 27720 ACH j 50) = CFM (50) x 60 / Volume = 1.93 Mechanical Ventilation required less than 3 ACH Pass' g results must be & ACH (50) or less ( x) Pass ( ) Fail FBC, E I ergy The bi ilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour i Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blowe door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Sectio 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provid ad to the code official. Testing shall be performed at any time after creation of all penetrations of the building therm l envelope. FBC, osidential Wher the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a. press re of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the d felling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Name: Energy House Technology Address: 3341 Pine Hill Trail, Palm Beach Gardens, FL I here certify that the above H se Infiltration results demonstrate compliance with FBC Energy Conservation requir ments in cordanc ith Sec 'on R402.4.1.2 Climate Zone 2. Signat re: Printe Name: Bruce Tschosik Lice ns( /Certification #. HERS Rater-RTIN: 4510152