BLOWER DOOR TEST FORM Permitting Department
House Infiltration Test Certification St. Lucie Counter
Prescriptive and Performance Method
Date} 5 / 14 / 2019 Permit #: 11S019- W0 g
Conn actor: Homecrete Homes
Job ddress: 9502 Poinciana Ct, Fort Pierce, FL 34951
Conk ruction: (x )'New Construction — Complete ( ) Existing —After Addition
Hou b Infiltration Test Results SLC Climate Zone 2
CFM (50) = 890 Test Date: 5 / 10 12019
Volu i ne = 27720
ACH j 50) = CFM (50) x 60 / Volume = 1.93 Mechanical Ventilation required less than 3 ACH
Pass' g results must be & ACH (50) or less ( x) Pass ( ) Fail
FBC, E
I ergy
The bi ilding or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour i Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blowe door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sectio 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provid ad to the code official. Testing shall be performed at any time after creation of all penetrations of the building
therm l envelope.
FBC, osidential
Wher the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a.
press re of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the d felling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Name: Energy House Technology
Address: 3341 Pine Hill Trail, Palm Beach Gardens, FL
I here certify that the above H se Infiltration results demonstrate compliance with FBC Energy Conservation
requir ments in cordanc ith Sec 'on R402.4.1.2 Climate Zone 2.
Signat re:
Printe Name: Bruce Tschosik
Lice ns( /Certification #. HERS Rater-RTIN: 4510152