HomeMy WebLinkAboutENERGY EFFICIENCY CODE 8-1-18LAUG
8YFORM 405-2017. Lino ob 01 2018,
FLO IDA ENERGY EFFICIENCY CODE FOR BUILDING 4(,
FI rida Department of Business and Professional Regulation - Residential Performance Method
�I
Project
me: HOMECRETE BLASER Builder Name: HOMECRETE
Street:
9502 POINCIANA CT Permit Office:
City, Stab,
Zip: PORT ST. LUCIE , FL, Permit Number:
Owner:
BLASER RES. Jurisdiction:
Design
cation: FL, ST LUCIE CO_INTL County:: St. Lucie (Florida Climate Zone 2 )
1. ,New cc
struction or existing New (From Plans)
9. Wall Types (2484.3 sqft.) Insulation Area
2. Single f
mily or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=6.5 2264.30 ft2
b. Frame - Wood, Adjacent R=11.0 220.00 ft2
3. Numbe
of units, if multiple family 1
c. N/A R= ft2
4. Numbet
of Bedrooms 3
d. N/A R= ft2
5. Is this
worst case? No
10. Ceiling Types (2750.0 sqft.) Insulation Area
a. Roof Deck (Unvented) R=20.0 2750.00 ft
6. Conditid
ad floor area above grade (ft2) 2760
b. N/A R= ft2
Conditid
ied floor area below grade (ft2) 0
c. N/A R= ft2
11, Ducts R ft2
7. Windo
(372.9 sqft.) Description Area
a. Sup: FAMILY ROOM, Ret: LAUNDRY, AH: LAUN 6 350
a. U-Fai
tor: Dbl, U=0.33 372.92 ft2
SHG
SHGC=0.25
b. U-Fa
I or: N/A ft2
12, Cooling systems kBtu/hr Efficiency
SHG
a. Central Unit 47.0 SEER:15.00
c. U-Fa
tor: N/A ft2
SHG:,:
13. Heating systems kBtulhr Efficiency
d. U-Fa
tor: NIA ft2
a. Electric Heat Pump 47.0 HSPF:8.50
SHG:',:
Area W
ghted Average Overhang Depth: 7.411 ft.
Area W
ghted Average SHGC: 0.250
14. Hot water systems
a. Electric Cap: 50 gallons
8. Floor T
es (2750.0 sqft.) Insulation Area
EF: 0.950
a. Slab-
n-Grade Edge Insulation R=0.0 2750.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits Pstat
Glass/Flo,
rArea: 0.136 Total Proposed Modified Loads: 84.38 PASS
Total Baseline Loads: 88.36
1 hereby c
rtify that the plans and specify tions covered by
Review of the plans and S�,1��
this calcul
tion are in compliance with t' Flori Ene gy
0111E
specifications covered by this ti = s O�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPAR
D BY:
Before construction is completed r -
DATE:
�. O
this building will be inspected for
compliance with Section 553.908
I hereby ci
rtify that this ' ding, is in compliance
Florida Statutes.
with the FI
Xase�sinedl,
rida Energ
G'OD WE
OWNE
GENT:
BUILDING OFFICIAL:
DATE:
DATE:
- complial ce requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certifie tfactory-sealed in accordance with R403.3.2.1.
- Complia ce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope eakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
�%w nV'
Co
7/19/201E 3:02 PM EnergyGauge(g) 1p�, USA - FlaRes2017 Section R405. C are Page 1 of 6
Y
FORM R4
5-2017
PROJECT
Title:
HOMECRETE BLASER
Bedrooms: 3
Address Type:
Street Address
Building
ype: User
Conditioned Area: 2750
Lot #
Owner N
me: BLASER RES.
Total Stories: 1
Block/SubdNision:
# of Unit
: 1
Worst Case: No
PlatBook:
Builder
me: HOMECRETE
Rotate Angle: 0
Street:
9502 POINCIANA CT
Permit C
flee:
Cross Ventilation: No
County:
St. Lucie
Jurisdicti
n:
Whole House Fan: No
City, State,
Zip:
PORT ST. LUCIE
,
Family T
pe: Single-family
FL,
New/Ex
'ng: New (From Plans)
Comme
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
Fl.
ST LUCIE_CO INTL FL VERO_BEACH_MUNi 39
90
7D
75
299
58
Medium
BLOCKS
Number
Name
Area Volume
1
Entire House
2750 27720
SPACES
Numbe
i, Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
BED 4
148 1480 No
1
3
1
No
Yes
Yes
2
LAUNDRY
77 770 No
0
1
No
Yes
Yes
3
BATH 3
57 570 No
0
1
No
Yes
Yes
4
2ND MASTER BED
299 2990 No
2
1
No
Yes
Yes
5
2ND MASTER BAT
130 1300 No.
0
1
No
Yes
Yes
6
FAMILY ROOM
440 4620 No
0
1
No
Yes
Yes
7
KITCHEN
288 2880 No
0
1
No
Yes
Yes
8
DINING ROOM
221 2210 No
D
1
No
Yes
Yes
9
LIVING
374 3740 No
0
1
No
Yes
Yes
10
STUDY
132 1320 No
0
1
No
Yes
Yes
11
MASTER BATH
168 1680 No
0
1
No
Yes
Yes
12
TIOLET MASTER
24 240 No
0
1
No
Yes
Yes
13
MASTER BEDROO
392 3920 No
2
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BED 4 26 ft
148 ft2
____
0 0
1
2 Slab -On -Grade Edge Insulatio
LAUNDRY eft
77 ft'
___
1 0
0
3 Slab -On -Grade Edge Insulatio
BATH 3 6 ft
57 ft2
___
1 0
0
4 Slab -On -Grade Edge Insulatio
2ND MASTER BE 23 ft
299 ft2
0 0
1
7/19/201
3:02 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 6
FORM R4 5-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Slab -On -Grade Edge Insulatio
2ND MASTER BA 23 ft
130 ftz
.1
0
0
6 Slab -On -Grade Edge Insulatio
FAMILY ROOM 44 ft
440 ftz
-___
0
0
1
7 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft
288 ftz
__-_
1
0
0
8 Slab -On -Grade Edge Insulatio
DINING ROOM 16 ft
221 ftz
1
0
0
9 Slab -On -Grade Edge Insulatio
LIVING 12 ft
374 ftz
____
0
0
1
10Siab-On-Grade Edge Insulatio
STUDY 14 ft
132 ftz
0
0
1
11SIab-On-Grade Edge Insulatio
MASTER BATH 32 ft
168 ftz
1
0
0
12SIab-On-Grade Edge Insulatio
TIOLET MASTER 4 ft
24 ftz
1
0
0
13SIab-On-Grade Edge Insulatio
MASTER BEDRO 25.5 It
392 ftz
0
0
1.
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 3076 ftz
0 ftz
Medium
0.9
No
0.9
No
20
26.6
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
2750 ft'
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
BED 4
0
Blown
148 ft'
0.1
Wood
2 Under Attic (Unvented)
LAUNDRY
0
Blown
77 ftz
0.1
Wood
3 Under Attic (Unvented)
BATH 3
0
Blown
67 ftz
0.1
Wood
4 Under Attic (Unvented)
2ND MASTER BE
0
Blown
299 ftz
0.1
Wood
5 Under Attic (Unvented)
2ND MASTER BA
0
Blown
130 ft?
0.1
Wood
6 Under Attic (Unvented)
FAMILY ROOM
0
Blown
440 ft'
0.1
Wood
7 Under Attic (Unvented)
KITCHEN
0
Blown
288 ftz
0.1
Wood
8 Under Attic (Unvented)
DINING ROOM
0
Blown
221 ftz
0.1
Wood
9 Under Attic (Unvented)
LIVING
0
Blown
374 ft'
0.1
Wood
10 Under Attic (Unvented)
STUDY
0
Blown
132 ftz
0.1
Wood
11 Under Attic (Unvented)
MASTER BATH
0
Blown
168 ftz
0.1
Wood
12 Under Attic (Unvented)
TIOLET MASTER
0
Blown
24 ftz
0.1
Wood
13 Under Attic (Unvented)
MASTER BATH
0
Blown
392 ft'
0.1
Wood
7/19/201� 3:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R4 5-2017
WALLS
Va
Adjacent Space
Cavity
Width
Et In
Height
Et In
Area
Sheathing Framing
R-1/alue Fraction
Solar Below
Absor Grnrie-*A
1
NW
Exterior
Concrete Block - Int Insul BED 4
6.8
14
0
10
0
140.0 ftz
0
0
0.5
10
2
NW
Exterior
Concrete Block - Int Insul BATH 3
6.5
6
0
10
0
60.0 ft2
0
0
0.5
0
-3
NW
Exterior
Concrete Block - Int InsuIND MASTE
6.5
23
0
10
0
230.0 ft2
0
0
0.5
0
-4
NE
Exterior
Concrete Block - Int InsuIND MASTE
6.5
13
0
10
0
130.0 ft2
0
0
0.5
0
_ 5
NW
Exterior
Concrete Block - Int instZND MASTE
6.5
10
0
10
0
100.0 ft2
0
0
0.5
0
-6
NE
Exterior
Concrete Block - Int InsBAMILY ROO
6.5
20
11
10
6
219.6 ft2
0
0
0.5
0
-7
SE
Exterior
Concrete Block - Int InsBAMILY ROO
6.5
20
11
10
6
219.6 ft2
0
0
0.5
0
_ 8
SW
Exterior
Concrete Block - Int InsOUNING ROO
6.5
14
0
10
0
140.0 ft2
0
0
0.5
0
- 9
NE
Exterior
Concrete Block - Int Insul LIVING
6.5
12
0
10
0
120.0 ft2
0
0
0.5
0
_ 10
SW
Exterior
Concrete Block - Int Insul STUDY
6.5
10
0
10
0
100.0 ft2
0
0
0.5
0
_ 11
NW
Exterior
Concrete Block - Int Insul STUDY
6.5
4
0
10
0
40.0 ft2
0
0
0.5
0
_ 12
SE
Exterior
Concrete Block - Int InsfilASTER BA
6.5
12
0
10
0
120.0 ft2
0
0
0.5
0
-13
SW
Exterior
Concrete Block - Int InsWASTER BA
6.5
14
0
10
0
140.0 ft2
0
0
0.5
0
14
W
Exterior
Concrete Block - Int InsbIASTER BA
6.5
6
0
10
0
60.0 ft2
0
0
0.5
0
_ 15
SE
Exterior
Concrete Block - Int Ins31OLET MAS
6.5
4
0
10
0
40.0 ft2
0
0
0.5
0
_ 16
NE
Exterior
Concrete Block - Int InsiWASTER BE
6.5
13
0
10
0
130.0 ft2
0
0
0.5
0
_ 17
SE
Exterior
Concrete Block - Int InsUASTER BE
6.5
25
6
10
0
255.0 ft2
0
0
0.5
0
_ 18
NW
Exterior
Concrete Block - Int InsMASTER BE
6.5
2
0
10
0
20.0 ft2
0
0
0.5
0
_ 19
NE
Garage
Frame - Wood BED 4
11
22
10
220.0 ft2
0.23
0.75
0
DOORS
#
Ornt
Door Type Space
Storms
U Value
Width
Height
Area
Ft In
Ft, In
1
NE
Wood 2ND MASTE
None
.39
3
7
6 8
23.9 ft2
2
SW
Wood DINING ROO
None
.39
3
7
6 8
23.9 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
J
Wall
Overhang
Omt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NW 1
Metal Double (Tinted) Yes
0.33
0.25
N
22.9 ft2
2 ft 0 in
1 ft 0 in
None
None
NW 2
Metal Double (Tinted) Yes
0.33
0.25
N
12.0 ft2
2 It 0 in
1 ft 0 in
None
None
NW 3
Metal Double (Tinted) Yes
0.33
0.25
N
45.0 ft2
2 ft 0 in
1 ft 0 in
None
None
NW 5
Metal Double (Tinted) Yes
0.33
0.25
N
12.0.ft2
2 ft 0 in
1 ft 0 in
None
None
NE 6
Metal Double (Tinted) Yes
0.33
0.25
N
20.0 ft2
2 ft 0 in
1 ft 0 in
None
None
SE 7
Metal Double (Tinted) Yes
0.33
0.25
N
20.0 ft2
26 ft 0 in
1 ft O In
None
None
SE 7
Metal Double (Tinted) Yes
0.33
0.25
N
72.0 ft2
12 ft 0 in
1 ft 01n
None
None
SW 8
Metal Double (Tinted) Yes
0.33
0.25
N
3.0 ft2
8 ft 0 in
1 ft 0 in
None
None
SW 8
Metal Double (Tinted) Yes
0.33
0.25
N
23.0 ft2
2 It 0 in
1 ft 0 in
None
None
11
NE 9
Metal Double (Tinted) Yes
0.33
0.25
N
64.0 ft2
10 It 0 in
1 ft 0 in
None
None;
1
SW 10
Metal Double (Tinted) Yes
0.33
0.25
N
23.0 ft2
2 ft 0 in
1 ft 0 in
None
None
1
SW 13
Metal Double (Tinted) Yes
0.33
0.25
N
8.0 ft2
2 ft 0 in
1 ft 0 in
None
None
1
NE 16
Metal Double (Tinted) Yes
0.33
0.25
N
48.0 ft2
8 ft 0 in
1 ft 0 in
None
None
7/19/201 ' 3:02 PM
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 4 of 6
FORM R4 5-2017
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
746 ft2
746 ft2
64 ft loft 1
INFILTRATION
# Scq
pe
Method
SLA
CFM 50 ELA EgtA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000448
3234 177.54 333.89 .3363 7
i
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5 47 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
SEER: 15 47 kBtu/hr cfm 0.73 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
LAUNDRY 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ft2
DUCTS
#
--- Supply --
Location R-Value Area
--- Return - - Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAG #
Heat Cool
1
FAMILY ROO 6 350 ft2
LAUNDRY
1 ft2 Default Leakage LAUNDRY (Default) (Default)
1 1
7/19120113:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R4 5-2017
TEMPERATURES
Program
blee Thermostat: Y
Ceiling Fans:
Heating
Jan
n
X�
Jul
Aug
Sep
Oct
H
Feb
MMar
Apr
May
Jun
i Jul
ri Aug
ri Sep
�
i Oct
Nov
Dec
Venting
Jan
X
C
X
Thermosta
Schedule:
HERS 2006 Reference
Hours
Schedule
pe
1
2
3
4
5
6
7
8
9
10
11
12
Cooling
)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling
H)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating
)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating
H)
PM
68
68
68
68
68
68
68
68
68
68
66
66
7/19/201 n 3:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
9502 POINCIANA CT, PORT ST. LUCIE, FL,
1. New col
1 struction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family
or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=6.5
2264.30 ft2
b. Frame - Wood, Adjacent R=11.0
220.00 ft2
3. Number
f units, if multiple family
1 c. N/A R=
ftz
4. Number
f Bedrooms
3 d. N/A R=
ft2
5. Is this a
orst case?
10. Ceiling Types Insulation
No a. Roof Deck (Unvented) R=20.0
Area
2750.00 ft2
6. Conditic
ied floor area (ft2)
2750 b. N/A R=
ft2
7. Windo
" Description
Area
a.
or: U=0.
11 Ducts
372.92 ft2 a. Sup: FAMILY ROOM, Ret: LAUNDRY, AH: LAUN
R ft2
6 350
SHG
SHG
SH
� ' SHGC=0.25
b. U-Fa
or: N/A
ft2
SHG
:
12. Cooling systems kBtulhr
Efficiency
c. U-Fa
or: N/A
ft2 a. Central Unit 47.0 SEER:15.00
d.
Area W
Area W
8. Floor T
a. Slab-
b. N/A
c. NIA
I certify
in this hoi
based on
Builder Si
Address t
N/A
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
47.0 HSPF:8.50
Average Overhang Depth:
7.411 ft.
Average SHGC:
0.250
Insulation
Area
14. Hot water systems
Cap: 50 gallons
de Edge Insulation R=0.0
2760.00 ft2
a. Electric
EF: 0.95
R=
ft2
R=
ft2
b. Conservation features
None
15, Credits
Pstat
this home has complied with the Florida Energy Efficiency Code for Building
in through the above energy saving features which will be installed (or exceeded)
before final 'section. Otherwise, a new EPL Display Card will be completed
stalled CodefcolTmijant Matores,
iature: � Date: a
New Home; Ci FL Z'
This is not a Building Energy Rating. if your Index is below 70, your home may qualify for energy efficient
le (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
ision's support staff.
required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/19,?2018 3:02 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
Project Summary
moo.„, Entire House
MA"N'::'_N'M'''N`' Lindstrom Air Conditioning
3581 IIfV MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954.421.4117 Fax: 954420.0064 Web: www.lindstromair.com
For: HOMECRETE
Notes: BLASER
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db 42 OF
Inside db 70 OF
Design TD 28 OF
Heating Summary
Structure 31815 Btuh
Ducts 4301 Btuh
Central vent (88 cfm) 2701 Btuh
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 38816 Btuh
Infiltration
Method
Construction quality
Fireplaces
Area (ftz
Volume (ft3)
Air changes/hour
Equiv. AVF (cfm)
Simplified
Average
0
He 2750
Co 2750
27720
27720
0.32
0.16
148
74
Job:
Date. Apr 18, 2018
By: LINDSTROM
Summer Design Conditions
Outside db
Inside db
Design TD
Dailyrange
Relative humidity
Moisture difference
90
75
15
L
50
61
OF
OF
OF
%
gr/lb
Sensible Cooling Equipment Load Sizing
Structure 30769 Btuh
Ducts 3264 Btuh
Central vent (88 cfm) 1447 Btuh
Blower 0 Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 33705 Btuh
Latent Cooling Equipment Load Sizing
Structure
4088
Btuh
Ducts
2506
Btuh
Central vent (88 cfm)
3667
Btuh
Equipment latent load
10261
Btuh
Equipment total load 43967 Btuh
Req. total capacity at 0.73 SHR 3.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make CARRIER
Make CARRIER
Trade
Trade
Model CH14NABO48
Cond CH14NABO48
AHRI ref
Coil FX4DNF061
AHRI ref
Efficiency
8.5 HSPF
Efficiency
15 SEER
Heating input
Sensible cooling
34200
Btuh
Heating output
44500 Btuh @ 470F
Latent cooling
12800
Btuh
Temperature rise
25 OF. - - -
Total cooling
47000
Btuh
Actual air flow
1600 `cfm
Actual air flow
1600
cfm
Air flow factor
0.044 cfm/Btuh
Air flow factor
0.047
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.78
F
Calculations approved by ACCA to meet all requirements of IaL EdCOPY.
201Wui-19 15:05:59
wrightsoft• Rlght•Suite® Universal 2013 13,0.12 RSU08398 Page 1
...ROJECTS ENERGYIA- MANUAL JIHOMECRETE BLASER.rup Calc = MJ8 Front Doortaces: N