Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE 8-1-18LAUG 8YFORM 405-2017. Lino ob 01 2018, FLO IDA ENERGY EFFICIENCY CODE FOR BUILDING 4(, FI rida Department of Business and Professional Regulation - Residential Performance Method �I Project me: HOMECRETE BLASER Builder Name: HOMECRETE Street: 9502 POINCIANA CT Permit Office: City, Stab, Zip: PORT ST. LUCIE , FL, Permit Number: Owner: BLASER RES. Jurisdiction: Design cation: FL, ST LUCIE CO_INTL County:: St. Lucie (Florida Climate Zone 2 ) 1. ,New cc struction or existing New (From Plans) 9. Wall Types (2484.3 sqft.) Insulation Area 2. Single f mily or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 2264.30 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Numbe of units, if multiple family 1 c. N/A R= ft2 4. Numbet of Bedrooms 3 d. N/A R= ft2 5. Is this worst case? No 10. Ceiling Types (2750.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2750.00 ft 6. Conditid ad floor area above grade (ft2) 2760 b. N/A R= ft2 Conditid ied floor area below grade (ft2) 0 c. N/A R= ft2 11, Ducts R ft2 7. Windo (372.9 sqft.) Description Area a. Sup: FAMILY ROOM, Ret: LAUNDRY, AH: LAUN 6 350 a. U-Fai tor: Dbl, U=0.33 372.92 ft2 SHG SHGC=0.25 b. U-Fa I or: N/A ft2 12, Cooling systems kBtu/hr Efficiency SHG a. Central Unit 47.0 SEER:15.00 c. U-Fa tor: N/A ft2 SHG:,: 13. Heating systems kBtulhr Efficiency d. U-Fa tor: NIA ft2 a. Electric Heat Pump 47.0 HSPF:8.50 SHG:',: Area W ghted Average Overhang Depth: 7.411 ft. Area W ghted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor T es (2750.0 sqft.) Insulation Area EF: 0.950 a. Slab- n-Grade Edge Insulation R=0.0 2750.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Flo, rArea: 0.136 Total Proposed Modified Loads: 84.38 PASS Total Baseline Loads: 88.36 1 hereby c rtify that the plans and specify tions covered by Review of the plans and S�,1�� this calcul tion are in compliance with t' Flori Ene gy 0111E specifications covered by this ti = s O� Code. calculation indicates compliance with the Florida Energy Code. PREPAR D BY: Before construction is completed r - DATE: �. O this building will be inspected for compliance with Section 553.908 I hereby ci rtify that this ' ding, is in compliance Florida Statutes. with the FI Xase�sinedl, rida Energ G'OD WE OWNE GENT: BUILDING OFFICIAL: DATE: DATE: - complial ce requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certifie tfactory-sealed in accordance with R403.3.2.1. - Complia ce requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope eakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). �%w nV' Co 7/19/201E 3:02 PM EnergyGauge(g) 1p�, USA - FlaRes2017 Section R405. C are Page 1 of 6 Y FORM R4 5-2017 PROJECT Title: HOMECRETE BLASER Bedrooms: 3 Address Type: Street Address Building ype: User Conditioned Area: 2750 Lot # Owner N me: BLASER RES. Total Stories: 1 Block/SubdNision: # of Unit : 1 Worst Case: No PlatBook: Builder me: HOMECRETE Rotate Angle: 0 Street: 9502 POINCIANA CT Permit C flee: Cross Ventilation: No County: St. Lucie Jurisdicti n: Whole House Fan: No City, State, Zip: PORT ST. LUCIE , Family T pe: Single-family FL, New/Ex 'ng: New (From Plans) Comme CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range Fl. ST LUCIE_CO INTL FL VERO_BEACH_MUNi 39 90 7D 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 2750 27720 SPACES Numbe i, Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BED 4 148 1480 No 1 3 1 No Yes Yes 2 LAUNDRY 77 770 No 0 1 No Yes Yes 3 BATH 3 57 570 No 0 1 No Yes Yes 4 2ND MASTER BED 299 2990 No 2 1 No Yes Yes 5 2ND MASTER BAT 130 1300 No. 0 1 No Yes Yes 6 FAMILY ROOM 440 4620 No 0 1 No Yes Yes 7 KITCHEN 288 2880 No 0 1 No Yes Yes 8 DINING ROOM 221 2210 No D 1 No Yes Yes 9 LIVING 374 3740 No 0 1 No Yes Yes 10 STUDY 132 1320 No 0 1 No Yes Yes 11 MASTER BATH 168 1680 No 0 1 No Yes Yes 12 TIOLET MASTER 24 240 No 0 1 No Yes Yes 13 MASTER BEDROO 392 3920 No 2 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 4 26 ft 148 ft2 ____ 0 0 1 2 Slab -On -Grade Edge Insulatio LAUNDRY eft 77 ft' ___ 1 0 0 3 Slab -On -Grade Edge Insulatio BATH 3 6 ft 57 ft2 ___ 1 0 0 4 Slab -On -Grade Edge Insulatio 2ND MASTER BE 23 ft 299 ft2 0 0 1 7/19/201 3:02 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R4 5-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab -On -Grade Edge Insulatio 2ND MASTER BA 23 ft 130 ftz .1 0 0 6 Slab -On -Grade Edge Insulatio FAMILY ROOM 44 ft 440 ftz -___ 0 0 1 7 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 288 ftz __-_ 1 0 0 8 Slab -On -Grade Edge Insulatio DINING ROOM 16 ft 221 ftz 1 0 0 9 Slab -On -Grade Edge Insulatio LIVING 12 ft 374 ftz ____ 0 0 1 10Siab-On-Grade Edge Insulatio STUDY 14 ft 132 ftz 0 0 1 11SIab-On-Grade Edge Insulatio MASTER BATH 32 ft 168 ftz 1 0 0 12SIab-On-Grade Edge Insulatio TIOLET MASTER 4 ft 24 ftz 1 0 0 13SIab-On-Grade Edge Insulatio MASTER BEDRO 25.5 It 392 ftz 0 0 1. ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 3076 ftz 0 ftz Medium 0.9 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2750 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BED 4 0 Blown 148 ft' 0.1 Wood 2 Under Attic (Unvented) LAUNDRY 0 Blown 77 ftz 0.1 Wood 3 Under Attic (Unvented) BATH 3 0 Blown 67 ftz 0.1 Wood 4 Under Attic (Unvented) 2ND MASTER BE 0 Blown 299 ftz 0.1 Wood 5 Under Attic (Unvented) 2ND MASTER BA 0 Blown 130 ft? 0.1 Wood 6 Under Attic (Unvented) FAMILY ROOM 0 Blown 440 ft' 0.1 Wood 7 Under Attic (Unvented) KITCHEN 0 Blown 288 ftz 0.1 Wood 8 Under Attic (Unvented) DINING ROOM 0 Blown 221 ftz 0.1 Wood 9 Under Attic (Unvented) LIVING 0 Blown 374 ft' 0.1 Wood 10 Under Attic (Unvented) STUDY 0 Blown 132 ftz 0.1 Wood 11 Under Attic (Unvented) MASTER BATH 0 Blown 168 ftz 0.1 Wood 12 Under Attic (Unvented) TIOLET MASTER 0 Blown 24 ftz 0.1 Wood 13 Under Attic (Unvented) MASTER BATH 0 Blown 392 ft' 0.1 Wood 7/19/201� 3:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R4 5-2017 WALLS Va Adjacent Space Cavity Width Et In Height Et In Area Sheathing Framing R-1/alue Fraction Solar Below Absor Grnrie-*A 1 NW Exterior Concrete Block - Int Insul BED 4 6.8 14 0 10 0 140.0 ftz 0 0 0.5 10 2 NW Exterior Concrete Block - Int Insul BATH 3 6.5 6 0 10 0 60.0 ft2 0 0 0.5 0 -3 NW Exterior Concrete Block - Int InsuIND MASTE 6.5 23 0 10 0 230.0 ft2 0 0 0.5 0 -4 NE Exterior Concrete Block - Int InsuIND MASTE 6.5 13 0 10 0 130.0 ft2 0 0 0.5 0 _ 5 NW Exterior Concrete Block - Int instZND MASTE 6.5 10 0 10 0 100.0 ft2 0 0 0.5 0 -6 NE Exterior Concrete Block - Int InsBAMILY ROO 6.5 20 11 10 6 219.6 ft2 0 0 0.5 0 -7 SE Exterior Concrete Block - Int InsBAMILY ROO 6.5 20 11 10 6 219.6 ft2 0 0 0.5 0 _ 8 SW Exterior Concrete Block - Int InsOUNING ROO 6.5 14 0 10 0 140.0 ft2 0 0 0.5 0 - 9 NE Exterior Concrete Block - Int Insul LIVING 6.5 12 0 10 0 120.0 ft2 0 0 0.5 0 _ 10 SW Exterior Concrete Block - Int Insul STUDY 6.5 10 0 10 0 100.0 ft2 0 0 0.5 0 _ 11 NW Exterior Concrete Block - Int Insul STUDY 6.5 4 0 10 0 40.0 ft2 0 0 0.5 0 _ 12 SE Exterior Concrete Block - Int InsfilASTER BA 6.5 12 0 10 0 120.0 ft2 0 0 0.5 0 -13 SW Exterior Concrete Block - Int InsWASTER BA 6.5 14 0 10 0 140.0 ft2 0 0 0.5 0 14 W Exterior Concrete Block - Int InsbIASTER BA 6.5 6 0 10 0 60.0 ft2 0 0 0.5 0 _ 15 SE Exterior Concrete Block - Int Ins31OLET MAS 6.5 4 0 10 0 40.0 ft2 0 0 0.5 0 _ 16 NE Exterior Concrete Block - Int InsiWASTER BE 6.5 13 0 10 0 130.0 ft2 0 0 0.5 0 _ 17 SE Exterior Concrete Block - Int InsUASTER BE 6.5 25 6 10 0 255.0 ft2 0 0 0.5 0 _ 18 NW Exterior Concrete Block - Int InsMASTER BE 6.5 2 0 10 0 20.0 ft2 0 0 0.5 0 _ 19 NE Garage Frame - Wood BED 4 11 22 10 220.0 ft2 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U Value Width Height Area Ft In Ft, In 1 NE Wood 2ND MASTE None .39 3 7 6 8 23.9 ft2 2 SW Wood DINING ROO None .39 3 7 6 8 23.9 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. J Wall Overhang Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW 1 Metal Double (Tinted) Yes 0.33 0.25 N 22.9 ft2 2 ft 0 in 1 ft 0 in None None NW 2 Metal Double (Tinted) Yes 0.33 0.25 N 12.0 ft2 2 It 0 in 1 ft 0 in None None NW 3 Metal Double (Tinted) Yes 0.33 0.25 N 45.0 ft2 2 ft 0 in 1 ft 0 in None None NW 5 Metal Double (Tinted) Yes 0.33 0.25 N 12.0.ft2 2 ft 0 in 1 ft 0 in None None NE 6 Metal Double (Tinted) Yes 0.33 0.25 N 20.0 ft2 2 ft 0 in 1 ft 0 in None None SE 7 Metal Double (Tinted) Yes 0.33 0.25 N 20.0 ft2 26 ft 0 in 1 ft O In None None SE 7 Metal Double (Tinted) Yes 0.33 0.25 N 72.0 ft2 12 ft 0 in 1 ft 01n None None SW 8 Metal Double (Tinted) Yes 0.33 0.25 N 3.0 ft2 8 ft 0 in 1 ft 0 in None None SW 8 Metal Double (Tinted) Yes 0.33 0.25 N 23.0 ft2 2 It 0 in 1 ft 0 in None None 11 NE 9 Metal Double (Tinted) Yes 0.33 0.25 N 64.0 ft2 10 It 0 in 1 ft 0 in None None; 1 SW 10 Metal Double (Tinted) Yes 0.33 0.25 N 23.0 ft2 2 ft 0 in 1 ft 0 in None None 1 SW 13 Metal Double (Tinted) Yes 0.33 0.25 N 8.0 ft2 2 ft 0 in 1 ft 0 in None None 1 NE 16 Metal Double (Tinted) Yes 0.33 0.25 N 48.0 ft2 8 ft 0 in 1 ft 0 in None None 7/19/201 ' 3:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R4 5-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 746 ft2 746 ft2 64 ft loft 1 INFILTRATION # Scq pe Method SLA CFM 50 ELA EgtA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000448 3234 177.54 333.89 .3363 7 i HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 47 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 47 kBtu/hr cfm 0.73 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None LAUNDRY 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS # --- Supply -- Location R-Value Area --- Return - - Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAG # Heat Cool 1 FAMILY ROO 6 350 ft2 LAUNDRY 1 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 7/19120113:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R4 5-2017 TEMPERATURES Program blee Thermostat: Y Ceiling Fans: Heating Jan n X� Jul Aug Sep Oct H Feb MMar Apr May Jun i Jul ri Aug ri Sep � i Oct Nov Dec Venting Jan X C X Thermosta Schedule: HERS 2006 Reference Hours Schedule pe 1 2 3 4 5 6 7 8 9 10 11 12 Cooling ) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling H) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating ) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating H) PM 68 68 68 68 68 68 68 68 68 68 66 66 7/19/201 n 3:02 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the EnergyPerformance Index, the more efficient the home. 9502 POINCIANA CT, PORT ST. LUCIE, FL, 1. New col 1 struction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 2264.30 ft2 b. Frame - Wood, Adjacent R=11.0 220.00 ft2 3. Number f units, if multiple family 1 c. N/A R= ftz 4. Number f Bedrooms 3 d. N/A R= ft2 5. Is this a orst case? 10. Ceiling Types Insulation No a. Roof Deck (Unvented) R=20.0 Area 2750.00 ft2 6. Conditic ied floor area (ft2) 2750 b. N/A R= ft2 7. Windo " Description Area a. or: U=0. 11 Ducts 372.92 ft2 a. Sup: FAMILY ROOM, Ret: LAUNDRY, AH: LAUN R ft2 6 350 SHG SHG SH � ' SHGC=0.25 b. U-Fa or: N/A ft2 SHG : 12. Cooling systems kBtulhr Efficiency c. U-Fa or: N/A ft2 a. Central Unit 47.0 SEER:15.00 d. Area W Area W 8. Floor T a. Slab- b. N/A c. NIA I certify in this hoi based on Builder Si Address t N/A ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 47.0 HSPF:8.50 Average Overhang Depth: 7.411 ft. Average SHGC: 0.250 Insulation Area 14. Hot water systems Cap: 50 gallons de Edge Insulation R=0.0 2760.00 ft2 a. Electric EF: 0.95 R= ft2 R= ft2 b. Conservation features None 15, Credits Pstat this home has complied with the Florida Energy Efficiency Code for Building in through the above energy saving features which will be installed (or exceeded) before final 'section. Otherwise, a new EPL Display Card will be completed stalled CodefcolTmijant Matores, iature: � Date: a New Home; Ci FL Z' This is not a Building Energy Rating. if your Index is below 70, your home may qualify for energy efficient le (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at port@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building ision's support staff. required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/19,?2018 3:02 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Project Summary moo.„, Entire House MA"N'::'_N'M'''N`' Lindstrom Air Conditioning 3581 IIfV MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954.421.4117 Fax: 954420.0064 Web: www.lindstromair.com For: HOMECRETE Notes: BLASER Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 31815 Btuh Ducts 4301 Btuh Central vent (88 cfm) 2701 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 38816 Btuh Infiltration Method Construction quality Fireplaces Area (ftz Volume (ft3) Air changes/hour Equiv. AVF (cfm) Simplified Average 0 He 2750 Co 2750 27720 27720 0.32 0.16 148 74 Job: Date. Apr 18, 2018 By: LINDSTROM Summer Design Conditions Outside db Inside db Design TD Dailyrange Relative humidity Moisture difference 90 75 15 L 50 61 OF OF OF % gr/lb Sensible Cooling Equipment Load Sizing Structure 30769 Btuh Ducts 3264 Btuh Central vent (88 cfm) 1447 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 33705 Btuh Latent Cooling Equipment Load Sizing Structure 4088 Btuh Ducts 2506 Btuh Central vent (88 cfm) 3667 Btuh Equipment latent load 10261 Btuh Equipment total load 43967 Btuh Req. total capacity at 0.73 SHR 3.9 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade Trade Model CH14NABO48 Cond CH14NABO48 AHRI ref Coil FX4DNF061 AHRI ref Efficiency 8.5 HSPF Efficiency 15 SEER Heating input Sensible cooling 34200 Btuh Heating output 44500 Btuh @ 470F Latent cooling 12800 Btuh Temperature rise 25 OF. - - - Total cooling 47000 Btuh Actual air flow 1600 `cfm Actual air flow 1600 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.78 F Calculations approved by ACCA to meet all requirements of IaL EdCOPY. 201Wui-19 15:05:59 wrightsoft• Rlght•Suite® Universal 2013 13,0.12 RSU08398 Page 1 ...ROJECTS ENERGYIA- MANUAL JIHOMECRETE BLASER.rup Calc = MJ8 Front Doortaces: N