HomeMy WebLinkAboutTRUSSQ=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
t II
A
Do not stand on
trusses
until they are braced per BCSI
&
properly nailed to straps
and hangers !!
A
ARRANGE
WITH
CRANE
OPERATOR IN ADVANCE FOR
A
STRONG BACK OF 41' -
46' IN LENGTH!!
should be read and given special attention o a )
persons installing trusses. �� m t 1�0(�'
SPACING NOTE COPY
All trusses are to be set 2'-0' on o
center except as noted. j24
MULTIPLE PLY TRUSSES MUST BE FASTENED 4uci�n4n�Bnt
TOGETHER PER ENGINEERING BEFORE roh
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY-
' I
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Spin or less
60 degrees
orless
iiiiii. m span
approx.
REFER TO BCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
>�rpprox D3 to
Tag line 12 of Span.
REFER TO SCSI
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
n are installed. A
AIR HANDLER NOTE
iless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
lirements. This may -be -In conflict with buTl�g code and A/C
ign requirements. Consult with Building Department and A/C
Contractor.
___-- --- --- —ter
WARNING
size of these trusses makes it necessary that they a set by a profeesional builder
it with and experienced in the problems and dangers of setting large span trusses.
wilder and erector should consult with an engineer licensed in Florida specializing
A roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
.AT PLATES BY CHAMBERS TRUSS
alp q. REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 02 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
HANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
F2-FA
GRC
JUS24
2-10d
4-1 Did
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
Hatch
WALL HEIGHT 111
WALL HEIGHT 101
Jldl-purNC UU I END
2X4 TOP CHORD
WALL HEIGHT 10'
END DETAIL: TYPICAL
The ArchFtect' or Ambitect's representative's
%hop draW)ry approval is NOT a :
"double contractor.
TttgFRIN011 ttrr`,4111 l remain responsible
for Check field measurements and
'erner ex
criteria. Architect's
approvalcovers general roof shape,
review of trues strap -ping, and loading on
Struoft*WrtOi;n,$L%vity anU uplift. leads and
their m e 1 .,. -.d
'rraden Emden A.LA. P.A.
HIP CARRIER LO,=ATED AS DIMENSIONED ON LAYOUT
24" O.C. THRU
CORNER JACKS 24-
ONLY
CORNER DETAIL
------- —==-
OVERHANGS NOT SHOWN FOR CLARITY
2 SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 10'
END DETAIL: A
n
30-08-00
12-00-00
33
t
7711
e
Jf:.pJ1
0
gg
I
4
§
1 00-
2-0 0
J5
! �'
1
r
r
c
GRID
a•
/ I/
y
d
b
o
Q
GRB 2-ply o
o
D
o
0
2-00
o
d
N
N
B
D7
2-00
--
--
--
-
-
-
a
o
o
o
B1
17-04-00
1
CO
ER
,;
4-04-00
7.08-00
82
w
D3
m
-oi
-oi
K
o
c
D3
0
B3
2-00
MV6
J1
B4
-
2-00
0
m
6-00-00
2-00-00 2-00-00
,g
MV4
J3
B5
11-00-00
14-00-00
Om
a
J5
h
o0
B6
°�
J5
N
12-08-04 TO COLUMN EDGE
00
00
O
N
GR2 2-Ply
9
r
9 r
r
r
F
r
r
H
FB
I�
2-00
_..
1-10.04
1.10-00;
z-0000 2-00-00
�i
FA
8.0 00
2-0
1_00
MV6
J7
F9
MV4
......,,,-,..,, .....„........
2" C FIFE
a
FB
tV
N
A
.7n
. , .. .. _
�.. .......
a
i
F8
J7Po
FB
a
F7
N
........«...,,...,.-_
a
J7
F7
7-00-00
2-00-00
18-00-00
-07-0
6-0D-00
1-10.04
1-10-00
6-00-00
2-00-00
13-08-04
�
�
m
0
7�W
o
F7
0
Yv
o
O
o
m
0
E
ct
ry
a
7
mQ
¢
13-08-04 TO COLUMN EDGE
Ft.
i
I.
MVA
.7
y
�
F5
.,..ww....,...�..�."..n........,..,
�
MVB
w
J7
F4
8 -00
MVC
U
p
O
.7mw.a.r.
n...-. a..,w,.,.......w.m.a,..v......
@
---. -
1
$
F3
¢
¢
d
< <
MVD
N
MVE
>
F2
9
j
GR7 2-ply
3/4"
U
ccD
v
F2
o
�
TB
a
E,
g
F2o
TA
11' CE LING
�4"
U
E
F1
U
U U
TA
GEE
0
o
F
LLI
o
TA
F
5-04-00 1
9-00-00
8-04-00
N
2-0 -00
TA
GEF
TA-
..�...-...r ..,,...P..
__
__
12-04-00
10-04-00
14-00-00
o
TA
o
0
0
0
o
o
p
b4
V J
TA
TA
TA
ATA
8-0
1
Z;4zlL
ATA
ATA
+"r
ATA
2-0
-Do
GEA
23-04-00
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout. which is the sole authority for
etermining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ndersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
fter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of *BCSI' summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
o redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
esponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour
for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or 9 no agreement a reasonable price.
nvoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
elivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
easonable aftomeys fee for Collections in event of payment not timely made. 1-1/2 % per month service charge will be
added for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
ayment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
ndersigned agrees to pay such indebtedness including attorneys fees, I default in payment for material be made by the
ecipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
herein, the parties agree that the sole venue for any such action will be Saint Lucie County Florida.
-- 11, Design responsibilities are per a lonai-Stan ard And Recommended Guidelines On Responsibilities For
Construction Using Metal Plate Connected Wood Trusses ANSI/rPIM/TCA 4 - 2002r"'
12. Warranty is per Chambers Truss Warranty attached.
DATED
SIGNED
OR TITLE
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can salve life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of pl®d, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT /NSTALL TRUSSES USING THIS 1
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSTS INC
3105 can er venue
Fort Pierce, Florida 34982-6423
800-551-5932
Fort Pierce 772.465.2012 Fax 772-465-8711
Vero Beach 772.569.2012 Stuart 772.286.3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS,COM
SCANNED
BY
St.Lucie ()Dullty
VERSION 7.4.1.431 -
LOADING/DESIGN CRITERIA REDUCIBLE
DESIGN CRITERIA
PER CODE SUCH AS SBC 1604,6.1
County
ST. LUCIE CO.
Building Department
CITY OF PORT ST. LUCIE
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE7-10
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 0
Top Chord Dead
7 4.2 0
Bottom Chord Live
"10-Non Conccurent 0
Bottom Chord Dead
10 3 0
Total Load
47 7.2 0
Duration Factor
1.25 0
Wind Speed
160mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15,
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
B
Miles from Ocean
5
Conforms to Florida Building Code 2017
R.D.L.=Restraining Dead Load
C.B=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75167
SCALE: 1/4" = 11-011
151 total trusses, 73 unique designs