HomeMy WebLinkAboutEVALUATION REPORTSCANNED r BY C-BUCK Engineering Florida Certificate ofAuthorization # 8064 Specialty Structural Engineering Evaluation Report Of J.V. Metals "1 Inch Nailstrip" Metal Roof Assembly for Florida Product Approval # FL 5985.1 Florida Building Code 2004 Method: 1- D Category: Roofing Sub - Category: Non Structural Metal Roofing. Product: 1"Nailstrip Panel Material: Steel Panel Thickness: 24 gauge Minimum Panel Width: 16" Maximum Support Type: Wood Deck Prepared for: J.V. Construction 1952 S.W. Hayworth Ave. Port St. Lucie, FL 34953 Prepared by: James L. Buckner, P.E. Florida Professional Engineer # 3124 Contents: Evaluation Report Pages 1— 3 Installation Method Pages 4 — 5 2 1334 S. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fag: (561)491-9928 Email: cbuck@cbuckinc.net C-BUCK Engineering FL #: FL 5985.1 Date: 12/19/05 Report No.: 05-2934NS-16-S4W Page 2 of 5 Florida Certificate of Authorization # 8064 Specialty Structural Engineering nufacturer: J.V. Metals Pi oduct Name: 1" Nailstrip Pi oduct Category: Roofing P oduct. Sub -Category: Non -Structural Metal Roofing l; aluation Method: 1-D P nel Type: Steel, minimum 24 gauge, minimum yield strength 50'ksi P Pel Material Material shall comply with Table 1507.4.3 Standards: 'nel Width(s) 16" Maximums (Net Coverage Width), pport Type: Wood Deck (Design of support system is not included in this evaluation) ' pport Description: 5/8" or greater CDX plywood, or wood plank, per Section 2308.10.8 o e Range: 2 : 12 or greater , esign Uplift Pressure: 52.5 psf (Safety Factor of 2:1) ttachment To Support: Panels shall be attached to the deck, with minimum #10 x minimum penetration through deck 3/1619, pancake -head, self -tapping, corrosion resistant, wood screws, per ANSI/ASME B18.6.4. nderlayment: Minimum underlayment shall be per Section 1507.4.5 ire Classification: Fire Classification is outside the scope of Rule 913-72, and is therefore not fincluded in this evaluation. Additional approved substrates may be added for Fire Classification purposes. [ stallation: Install the "1 in. Nailstrip Panel' to the deck with screw rows spaced 3" from all,ends and maximum 16" o.c. thereafter along the length of the panel, located at each rib. Within rows, screws shall bespaced, maximum 16" o.c. across'the width of the panel. Install system in compliance with the attached installation method. 1 FL M FL 5985.1 Date: 12/19/05 Report No.: 05-293-INS-16-S4W Page 3 of 5 C-BUCK Engineering , Specialty Structural Engineering Florida Certificate of Authorization # 8064 Q ality Assurance: Manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 9B-72.070 (3) for manufacturing'under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. Pi Irformance Standards: The roof assembly described herein has been tested in accordance with: • UL580-94 — Test for Uplift Resistance of Roof Assemblies —with Revisions through February 1998 de Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2004, Section 1507.4. Report Scope: This product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code, as related to Rule 913-72. Limitations: The required design wind loads shall be determined for each project. The maximum fastener spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code, Section 105 or 106. This product is not approved for use in the High Velocity Hurricane Zone. Data: 1. UL580-94 with 1998 Revisions Test By Underwriters Laboratories, Inc. (TST ID: 1740) File R21264, Project 02NKI 1243, Date: 4/24/03 2. Quality Assurance By Keystone Certifications, Inc. (QUA ID: 1824) 3. Certification of Independence By,James L. Buckner, P.E. @ C-Buck Engineering (ANE ID: 1916) 6 i - FL #: FL 5985.1 Date: 12/19/05 Report No.: 05-293-INS-16-S4W Page 4 of 5 C-BUCK Engineering Specialty Structural Engineering Florida Certificate of Authorization # 8064 Installation Method J.V. Metals "1 in. Nailstrip" Attached to Wood Deck 16" Coverage q ee Panel Profile Assembly Profile 1 �- FL #: FL 5985.1 Date: 12/19/05 Report No.: 05-293-INS-16-S4W Page 5 of 5 C-BUCK Engineering Florida Certificate ofAuthorization # 8064 Specialty Structural Engineering Installation Method (Continued) J.V. Metals 461 in. Nailstrip" Attached to Wood Deck Fasteners - #10 Pancake; -Head 1" Nailstrip Panel Self -Tapping Screws �- Ir. �— Deck - Minimum 518" Wood Assembly Isometric View