HomeMy WebLinkAboutBLOWER DOOR TEST FORMPlanning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 SCANNED Fort Pierce, FL 34982 BY Phone: 772-462-2165 Fax: 772-462-6443 'St . Lucie Coantv BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method te: j 21 1 R• I' ISr Permit #: /$Cae 0 00 3 ntractor: Address: Construction — Complete ( ) Existing — After Addition House Infiltration Test Results SLC Climate Zone 2 CFM (50) = 9-7 3 Test Date: 9-1 1 5' Volume = �1 2 (0 32 ACH (50) = CFM (50) x 60 / Volume = �_ Mecha l Ventilation required less than 5 ACH Passing results must be & ACH (50) or less ( ass ( ) Fail BC, Energy he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per our in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones .3 through 8. Testing shall be conducted with a lower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in ection 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an pproved third party. A written report of the results of the test shall be signed by the party conducting the test and rovided to the code official. Testing shall be performed at any time after creation of all penetrations of the building Dermal envelope. Residential Vhere the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a iressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation he dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. pany Name: k S U0,4-4egr� Address: hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation �quirements in accordance with Section R402.4.1.2 Climate Zone 2. re: rinted Name: C,kUc„Q6V'hi r )'p,V atc-�-- cense/Certification #: k S4-C�!3L� 1 g� �w _3;ning & Development Services Building & Code Regulation Division SCANNED 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 BY 772-462-2165 Fax 772-462-W3 q Ite L Ui,1Q C(OUnty FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method �T Permit #. ! 9,0 " 0 0 0'X RECEIVED i0FILCOEptertmentC unty Lot #. 13 Address: Zd�P t ��g1�L,acP C. u: ost Construction Test ❑ Rough -in Test Temperature (F): )r Temperature (F): Ti Leakage: ❑ Default ❑ Prop. Leak Free Pressure. (Pa) sine Duct Pressure (optional) (Pa) Press. (Pa) Flow Ring Fan Press Installed (Pa) Ty Name. Floor Area 01:2): Primary Location of Supply Ductwork Primary Location of Return Ductwork aroposed On = G S Total Leakage (cfm): 5 0 Total Leakage per 100 sglt .03 CFM25 x 100 divided by the CFA = Duct Leakage CFW100 sgtt r certify that the above Dud Sealing Leakage results demonstrate compliance with 5", Edition FBC Energy Conservation requirements in accordance with R403.2.2. re: Name: OWA60CACLicenselCertificate# Certificate of Achievement THIS ACKNOWLEDGES THAT Oluwafemi Benedict HAS MET THE STANDARD REQUIRED BY 1S lightyears Inc, A RESNET QUALITY ASSURANCE APPROVED PROVIDERSHIP ORGANIZATION, AS A RESIDENTIAL ENERGY FIELD ANALYST REFA # 151-6394 Certification Date: November 11, 2018 Certification Expires: November 11, 2019 Tim Smith, RESNET Quality Assurance Designee 15 11 htyea rs RESNET QA Provider # (1998-199)