BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
te: j 21 1 R• I' ISr Permit #: /$Cae 0 00 3
ntractor:
Address:
Construction — Complete ( ) Existing — After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50) = 9-7 3 Test Date: 9-1 1 5'
Volume = �1 2 (0 32
ACH (50) = CFM (50) x 60 / Volume = �_ Mecha l Ventilation required less than 5 ACH
Passing results must be & ACH (50) or less ( ass ( ) Fail
BC, Energy
he building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
our in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones .3 through 8. Testing shall be conducted with a
lower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
ection 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
pproved third party. A written report of the results of the test shall be signed by the party conducting the test and
rovided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
Dermal envelope.
Residential
Vhere the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a
iressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
he dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
pany Name: k S U0,4-4egr� Address:
hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
�quirements in accordance with Section R402.4.1.2 Climate Zone 2.
re:
rinted Name: C,kUc„Q6V'hi r )'p,V atc-�--
cense/Certification #: k S4-C�!3L�
1 g� �w
_3;ning & Development Services
Building & Code Regulation Division
SCANNED
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34982
BY
772-462-2165 Fax 772-462-W3
q
Ite L Ui,1Q C(OUnty
FBC ENERGY CONSERVATION CODE
Duct Sealing Certification
Prescriptive and Performance Method
�T
Permit #. ! 9,0 " 0 0 0'X
RECEIVED
i0FILCOEptertmentC unty
Lot #. 13
Address: Zd�P t ��g1�L,acP C.
u: ost Construction Test ❑ Rough -in Test
Temperature (F):
)r Temperature (F): Ti
Leakage: ❑ Default ❑ Prop. Leak Free
Pressure. (Pa)
sine Duct Pressure (optional) (Pa)
Press. (Pa) Flow Ring Fan Press
Installed (Pa)
Ty Name.
Floor Area 01:2):
Primary Location of Supply Ductwork
Primary Location of Return Ductwork
aroposed On = G S
Total Leakage (cfm): 5 0
Total Leakage per 100 sglt .03
CFM25 x 100 divided by the CFA = Duct Leakage CFW100 sgtt
r certify that the above Dud Sealing Leakage results demonstrate compliance with 5", Edition FBC Energy Conservation requirements in accordance with
R403.2.2.
re:
Name: OWA60CACLicenselCertificate#
Certificate of Achievement
THIS ACKNOWLEDGES THAT
Oluwafemi Benedict
HAS MET THE STANDARD REQUIRED BY 1S lightyears Inc, A RESNET
QUALITY ASSURANCE APPROVED PROVIDERSHIP ORGANIZATION,
AS A RESIDENTIAL ENERGY FIELD ANALYST
REFA # 151-6394
Certification Date: November 11, 2018
Certification Expires: November 11, 2019
Tim Smith,
RESNET Quality Assurance Designee
15 11 htyea rs
RESNET QA Provider # (1998-199)