HomeMy WebLinkAboutSITE PLANREVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCK POOLDESIGNNET POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDNG BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 8th EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/IGC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITEISHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO AT S.M.-I 5. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS, 6) PIPING. ALL POOL PIPING SHALL BEAR THE N:S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.U.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F S.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE I$ NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F. B.C, 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 680.26(C) 68449I� � • 9l STATE OF 1:& •hyS SON Ais�p.`�� B. M. AKERS P.E. 68449 SITE PLAN TITLE LOT 2 VENETIAN ADMINISTRATION LLC DESCRIPTION 4416 N. HWY Al PIERCE. 49 Scale: 1 in = 30ft. Oin. DATE 7/10/2019 AG 1 OF 5 TOP OF POOL EQUIPMENT SLAB TO BE INSTALLED AT BASE FLOOD ELEVATION +1' POOL EQUIPMENT LOCATION l Oft. HL PROVIDE MIN. 42" BARRIER BY OTHERS PER PERMIT #1901-0541 5' SUN SHELF W1 FOUNTAIN BUBBLER TOP OF POOL EL. 23.5' DEC-O-DRAIN 3 ft. DIMENSIONS TAKEN @ WATERLINE -111 -24" 9'*v _ll I SLOPE POOL DECK 118" PER V AWAY FROM POOL 11 ft 4 in. r 12V LED LIGHT 23 ft. 4 in. LOT 2 C N ro d 5 ft. 3 in. PROVIDE MIN. 42" BARRIEF BY OTHERS PER PERMIT #1901-0541 A REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC NOTES: IF WATER SOURCE IS A PRIVATE WELL. PREFILTER WATER TO FILL POOL ALL METALLIC ITEMS WITHIN 5.0" OF WATERS EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (u.I. Ilatetl) FROM POOL STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS.,..,.G. F.I. OUTLET 10' MIN. AND 20' MAX. FROM POOL IF ENCLOSURE IS REQUIRED ADD SCREEN OR FENCE AROUND POOL OR PROPERTY GATES TO BE SELF CLOSING AND SELF LATCHING PROVIDE DOOR AND WINDOW ALARMS AS REQUIRED STEEL OVERLAP @ 48 TIMES DIAMETER ESTABLISH THE LOCATION OF ALL UTILITIES AT SWIMMING POOL CONSTRUCTION SITE AND HOLD MINIMUM CLEARANCE DIMENSIONS ESTABLISHED BY THE LOCAL REGULATORY AGENCY. ALLOW MIN. IT HORIZONTAL CLEARANCE FROM OVERHEAD ELECTRIC LINES TO POOL WATER. DECK SHALL HAVE A SLIP RESISTANT FINISH WITH NO SHARP EDGES AND BE POSITIVELY SLOPED FOR DRAINAGE PROVIDE WEEP HOLES AND DEWATERING PUMPS AND ANY OTHER METHODS NECESSARY TO PREVENT THE POSSIBILITY OF THE POOL FLOATING DUE TO HYDROSTATIC UPLIFT PRESSURE WHEN THE POOL IS EMPTY. BACKFILLING OF THE POOL SHALL BE DONE CAREFULLY TO ASSURE THAT NO DAMAGE TO THE PIPING OCCURS AND BACKFILLING SHALL BE DONE WITH CLEAN SOIL FREE FROM ORGANICS AND DEBRIS AND SHALL BE COMPACTED SO THAT NO VOIDS EXIST PROVIDING A FIRM BEARING FOR THE DECK ALL PIPING TO BE PVC SCHEDULE 40 MINIMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO GUNITE (CONCRETE) THIS IS NOT A DIVING POOL. SWIMMING POOL FILL HOSE TO BE EQUIPPED WITH VACUUM BREAKER LOCATE POOL RETURNS DOWN 18" MIN. BELOW THE POOL BEAM POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101.6.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERALNOTES: 1) PLANS DESIGNED PER 2017 Sth EDITION F. B, C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP TANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PI 13) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT, 4) ALL CONCRETE SHALL CONFORM TO A.CJ 31 B-11. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3, 000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T.S.M: 1S. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.C. POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REOUIREMENTS IN F.B.C. g) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION.680.26(C) oil# K •• • Na L'•• •••i ,N • 40�II t� a 664Ida STATE OF f-U g.D *3 o a .•��4�.r v#QW10NA�y,,��� B. M. AKERS P.E. 68449 LAYOUT PLAN TITLE LOT 2 VENETIAN ADMINISTRATION LLC DESCRIPTION 4416 N. HWY Al FT. PIERCE FL.34949 Scale: 114" = 1LO" DATE 7/10/2019 PAGE 2 OF 5 PIPING NOTES ALL PIPING TO BE PVC SCHEDULE 40 N�. iMUM AND ALL PRESSURE PIPING AND MAIN DRAIN PIPING MUST BE PRESSURE TESTED PRIOR TO y GUNITE (CONCRETE) PROVIDE 5 PIPE DIAMETERS CLEAR LENGTH BEFORE PUMPS ON SUCTION SIDE LABEL ALL VALVES AND PIPES PIPING TO BE INSTALLED 18" MIN BELOW GRADE AND TRENCHES TO BE CONDUIT FOR WATER LEVELOR TO BACKFILLED W/ CLEAN SAND SOLENOID III WATER SUPPLY WELL WATER: IF POOL IS TO BE FILLED WITH WELL WATER PROVIDE PREFILTER WHEN FILLING POOL r— AUTOFILL SENSOR IS IN TROUGH AND WATER IS ADDED TO POOL POOL EQUIPMENT LOCATION TOP OF POOL EQUIPMENT SLAB TO BE INSTALLED AT BASEFLOOD ELEVATION +1' (16.4 NAVD) +jR 3" POOL n 2" TROUI 3" SPA POOLDESIGNNET I I I I PIPING IS SHOWN j SPACED FOR CLARITY j CONNECT SPA AIR LINE I TO EACH THERAPY JET j I I j 3n. I i I .- LEVEL CONDUIT— .- ............ AUTOFILL LINEc FOUNTAIN LINE— — - LIGHT CONDUIT— ------------ 2" VACUUM LINE-- LIGHT CONDUIT ------------------- MAIN -24" -0 -5, 0„ CRITICAL: PROVIDE PLUMB AND ACCURATE LEVEL WATER LINE FOR NEGATIVE EDGE Hh 4x CEP Y +0" MAIN DRAIN 5' SUN SHELF W/ FOUNTAIN BUBBLER NOTE: LIGHTS MUST BE AMBER COLOR 12V LED LIGH),, 0v —��------------------------- i----_-_-_-_--------•------------_.------ ---------.._.----------------------------------------.----------_-------_-_-__----__-_-_-------- LEGEND: O-RETURN LINE -ELEVATION -2-WAY VALVE • 3-WAY VALVE CHECKVALVE -BUTTERFLY VALVE SKIMMER VALVE ACTUATOR NTS NOT TO SCALE 0 OVERFLOW LINE ❑ CONCRETE DECK BY REVIEWED FOR OTHERS CODE COMPLIANCE ST. LUCIE COUNTY BOCC MIN. 18" CLEAR FOR FUTURE --- SOLAR IC40 CELL NOTE. WA FERBOND FITTING TO BE BELOW WATERLINE AT ALL TIMES ATER BOND FITTING PB2008 2.1/2" POOL RETURN 1-1/2" BUBBLER FILTER PAD DETAIL 3 HP PENTAIR 1.1/2 H.P. AIR VS PUMP BLOWER I I FILTERLU d N F- O '7 ¢ N CHECK VALVE Provide min. 4 times pipe diam. clear straight length a O a v a CHECK Z VALVEo o p 2-1/2" SPA Z JETS O T PENTAIR 1-1/2 H.P.V.S. EDGEPUMP w O O a O J a a y I I I i I I I I I I I POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 454.2.6A /R4101..6,1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 20176th EDITION F, B. C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANS1/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 150C PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS, SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A. C.131sl 1. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3.000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITEISHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T. S. M. 15, STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 8J PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F.-PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F. B.0 POOL EQUIPMENTTO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. 3) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 580,26(C) •1 IINq�� ` sF•.. �.• .;. , 00 .•` t . 88NY �� I I � i • -0 STATE OF ?� % A. '•g O.� F'•., O A ••' B. M. AKERS P.E. 68449 PIPING PLAN TITLE LOT 2 VENETIAN ADMINISTRATION LLC DESCRIPTION 4416 N. HWY A1A FT. PIERCE, FL.34949 Scale: 1/4" = V-0" DATE 7/10/2019 PAGE 3 OF 5 G.F,1, (NOTE BELOW) -.111 , 3912 IN 12" PANEL CONDUIT CONTROLLER HLORINATOR- 3#BTHHN & 1 #101N 1" CON, HEAT - PUMP GFI PUMP BREAKER 3 0121N 12" 1.5HP AIR BLOWER 4.5A 220V MOTOR I i PUMP I MPOOL PUMP OTOR COMPLIES WITH SHIP VS 403.9 FBC ALL ELECTRICAL PER PENTAIR 2014 N.E.C. 16A ALL EQUIPMENT TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS ALL METALLIC ITEMS WITHIN 5'-0" OF WATER'S EDGE OF POOL TO BE BONDED WITH #8 SOLID INSULATED WIRE (UL listed) FROM POOL STEEL, ALL GROUND WIRES CONNECTED TO STEEL WITH BRASS GROUND LUGS...... G.F./. OUTLET 10' MIN, AND 20' AAAV CD(n&A Onni OONCRETE DECK 1Y OTHERS 4' DECK BY OTHERS iI 11 I II #8 AWG INSULATED COPPER jl I I WIRE EPDXY COATED 12v TRANSFORMER !---- - ---------------- --------1 LIGHT CORD LIGHT (IN CONDUIT) #8 AWG INSULATED COPPER WITH #4s @ 12" OYC WIRE EPDXY HORIZONTAL & VERTICAL COATED PLASTER FINISH 12" FLOOR WITH #5 12" O/C BOTH WAYS '^ DOUBLE MAT POOL STEEL OVERLAP @ 48 TIMES DIAMETER STRUCTURAL DETAIL ANTI -ENTRAPMENT 1. TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION PUMP ONLY DURING PEAK HOURS 1O Z AQUASTAR THAT 2. POOL FILTRATION PIPING MUST BESIZEDIN MAIN DRAIN 32CDFL101 THE VELOCITY DOES NOT EXCEED H IN THE 316 GPM Q 3.9 FPS RETURN LINE AND BFPS IN THE SUCTION LINE. SUCTION FLOOR INSTALLATION • . 3. FILTER AREA BASED ON 6 HOUR TURN OVER PILING POOL 4. FILTER PUMPS -A MIN. OF 4 PIPE DIAMETERS SHALL BE INSTALLED BEFORE PUMP. SEE PILING PLAN — 5. INLET FITTINGS SHALL BE DIRECTIOINAL. —�. 6. PROVIDE A MIN. 18" OF HORIZONTAL OR VERTICAL OAT BOND CONNECTION POOL/ SPA PIPE BETWEEN FILTER AND HEATER OR DEDICATED W/ APPROVED POTTING COMPOUND SUCTION AND RETURN LINES SHALL BE: INSTALLED TO MAIN DRAIN DETAIL ALLOW FOR FUTURE ADDITION OF SOU4R HEATING 12V UNDERWATER EQUIPMENT, UL APPROVED LIGHT EXPANSION #4s e JOINT O/C BOTH WAYS — �S (SEALED DOUBLE MAT 2" OVERFLOW TOSTORM GRADEBEAMS WITH 6 #5 AND #3 HOOPS 12"O/C 1" CONDUIT TO LOOR 1H WAYS WITH #5 BREAK AWAY @ 12" O/C BOTH WAYS WALL $FOUNDATION Ll DOUBLE MAT BY OTHERS PER PERMIT 41901-0541 PILINGS BY OTHERS NEGATIVE EDGE SECTION Scale: nts BEND PILING L STEEL INTO POOLFLOOR TYP. POOL SECTION Scale: nts POOLDESIGNWNET 23'-4" 10'-6" VGB APPROVED MAIN DRAIN GRATE SECURED IN PLACE SO TOOLS — ARE REQUIRED FOR REMOVAL MAXIMUM FLOOR SLOPE lft.IN7ft 12" FLOOR WITH #5 0 12" O/C BOTH WAYS DOUBLE MAT GRADESEAMS WITH 6 #5 AND #3 HOOPS ® 12" O/C 8" WALL WITH #4s 12" O/C BOTH WAYS 12" FLOOR WITH #5 012" O/C BOTH WAYS DOUBLE MAT GRADESEAMS WITH 8 #5 AND #3 HOOPS 12"O/C PILINGS BY OTHERS SPA SECTION Scale: nts 114' TAP CON BOLTS 3" LONG @ (4) LOCATIONS PUMP 1W TAP CON BOLTS 114' TAP CON BOLTS 4" THICK CONCRETES 13 EQUIPMENT ANCHORAGE DETAIL � I I POOL ' I i I . I PER 2014 NEC (680.26C "EQUIPOTENTIAL BONDING GRID"): #B AWG WIRE Is" TO 24" HORIZONTALLY BEYOND THE ABAESDCWG ROIOPPER BONDING JUMPER SHALL BE INSTALLED IN AT LEAST FOUR (4) LOCATIONS AROUND PERIMETER OF THE POOL OR SPA AND ATTACHED TO DECK STEEL WI APPROVED GROUND LUGS. EQUIPOTENTIAL BONDING GRID # 400 3/4" CLEVIS HANGERROD #7 REBAR PIPE 4 SUPPORTS 4' O/C -- ----- — 2"PVC 3/8" THREADED STEEL ROD #400 CLEVIS HANGERS SIZE VARIES W/PIPE SIZE RETURN LINE LOOP V I., PVC PIPING 4'-0" O/C MAX. WALL SECTION PIPING NTS REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC MRI/PSP.7 INE TYPE ISIZE LOW GPM PS AIN DRAIN LINE 3" 130 5.9 ETURN LINE 12-1/2"1 130 1 8.5 HERAPY JETS 1 2-1IZ' 1 130 1 8.5 POOL SPECIFICATIONS LENGTH 23 ft. 4 in. WIDTH 11 ft. 8 in. MIN. DEPTH 3 ft. MAX. DEPTH 4 ft. 6 in. AREA 228 s.f. PERIMETER 70ft INLETS (2) 1-1/2" DIRECTIONAL INLETS LIGHT(S) (1) 12V 5G LED AMBER COLOR - PENTAIR PUMP (1) INTELLIFLO VARIABLE SPEED 011018 - PENTAIR FILTER PENTAIR CARTRIDGE CCP320 S.F. MAIN DRAINS POOL (3) AQUASTAR CHANNEL CONTROLLER (1) EASYTOUCH - PENTAIR CHLORINE GENERATOR INTELLICHLOR IC-20 - PENTAIR FEATURE COLOR VISION LED BUBBLER - PENTAIR SPA SPECIFICATIONS +flmIn, ILIGHT(S) (1) 12V 5G LED AMBER COLOR - PENTAIR % POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954) 941-1124 info@swimmingpoolplan.com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454.2 INCLUDING BUT NOT LIMITED TO 464.2.8.8 IR4101.8.1 ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2.17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES'. 1) PLANS DESIGNED PER 2017 681 EDITION F.B.C. RESIDENTIAL CHAPTERS 42 & 45 and ANSI/NSPI 3, ANSIINSPI 5, ANSI/APSP 7,ANSI/APSPACC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PSF. 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH. IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A.C.I 318-11, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/ SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS GRADE 60 OR NEW BILLET STEEL CONFORMING TO A.T.S.M.15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPINGALL POOL PIPING SHALL BEAR THE N.S.F: PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P, V. C. MIN, POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.S.O 7) WATER S1'-PLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NU CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. 8) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 880.26(C) loss d h � A SF•,•• • •mot #.' 88449_I1 l' 1 w •-0: STATE OF .�wZ . S0- 5%,. c.4 O R `0 �`2% ,�;iI&1ONA� � �0, B. M. AKERS P.E. 68449 DETAILS TITLE LOT 2 VENETIAN ADMINISTRATION LLC DESCRIPTION 4416 N. HWY A1A FT, PIERCE FL.34949 Scale: 1/4" = V-0" DATE 7/10/2019 PAGE 4 OF 5 I� I PILE GROUT MIN. 5000 PSI @ 28 (13) 16"ROUND AUGER -CAST 12'FLOOR WITH DOUBLE MAT CONC. PILINGS 35 TON ass®1Z'Q/C BOTHWAYS COMPRESSION CAPACITY INSTALLED TO 30' BGL OR REFUSAL 3 (BY OTHERS) I I I I I I 6 # 16" DIAM. AUGER _ CAST PILE PROVIDE SONG TUBE TO EXTEND PILE ABOVE GRADE TO POOL SLAB ELEVATION ALL PILES TYP. #3-8" X 8" HOOPS @ 8" O/C LENGTH OF PILE PILING&PADSECTION VIEW NTS POOLDESIGNNET r. __J L__J 16" DIAM, AUGER CAST PILE #5 BARS @ 12" C/C BOTH _ WAYS IN POOL FLOOR REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC POOLDESIGN.NET 30 S.W. 5th COURT POMPANO BEACH FLA 33060 (954)941-1124 info@swimming pool plan. com CERTIFICATE OF AUTHORIZATION N. 9871 DESIGN PER FLORIDA BUILDING CODE 454,2 INCLUDING BUT NOT LIMITED TO 454.2.6.6 /R4101 Al ENTRAPMENT PROTECTION FOR SUCTION INLETS 454.2,17 RESIDENTIAL SWIMMING BARRIER REQUIREMENTS REVISIONS GENERAL NOTES: 1) PLANS DESIGNED PER 2017 8th EDITION F, B. C. RESIDENTIAL CHAPTERS 42 & 46 and ANSI/NSPI 3, ANSI/NSPI 5, ANSI/APSP 7,ANSI/APSP/ICC 15 2) THE SITE MUST HAVE UNDISTURBED SAND, ROCK, SAND AND ROCK, WITH A MINIMUM BEARING VALUE OF 1500 PER 3) THE FOLLOWING IS DETERMINED BY RATIONAL ANALYSIS. SOIL CONDITIONS IN THIS AREA HAVE BEEN BY PAST EXPERIENCE CAPABLE OF SUPPORTING A POOL AND DECK OF SIMILAR SIZE AND DEPTH, IF CONDITIONS DIFFER FROM CONDITIONS SPECIFIED ABOVE, THIS ENGINEER SHALL BE NOTIFIED PRIOR TO FURTHER CONSTRUCTION OF THIS PROJECT. 4) ALL CONCRETE SHALL CONFORM TO A, C,I 318-11, CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI FOR PNEUMATICALLY PLACED CONCRETE (GUNITE/SHOTCRETE) 5) ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OR NEW BILLET STEEL CONFORMING TO A.T,S.M -15. STEEL SHALL BE BENT, LAPPED, AND PLACED IN ACCORDANCE WITH A.C.I. STANDARDS AND SPECIFICATIONS. 6) PIPING: ALL POOL PIPING SHALL BEAR THE N.S.F: PW SEAL OF APPROVAL AND SHALL BE SCHEDULE 40 P.V.C. MIN. POOL PIPING TO COMPLY WITH F.B.0 . POOL EQUIPMENT TO APPLY TO F.B.C. 7) WATER SUPPLY AND DISPOSAL SHALL BE SO ARRANGED THAT THERE IS NO CROSS CONNECTION WITH A DOMESTIC WATER SUPPLY OR WATER DISPOSAL SYSTEM AND SHALL MEET ALL REQUIREMENTS IN F.B.C. g) EQUIPOTENTIAL BONDING GRID SHALL BE INSTALLED PER 2014 NEC SECTION 68026(C) t gt1gl o K bINO * o IL . g 9 ; STATE OF C OW g8�„NA� t••• B. M. AKERS P.E. 68449 PILING PAGE TITLE LOT 2 VENETIAN ADMINISTRATION LLC DESCRIPTION 4416 N. HWY A1A FT. PIERCE FL.34949 Scale: 3/8" = V-0" DATE 7/10/2019 PAGE 5 OF 5