HomeMy WebLinkAboutEVALUATION REPORT 8-1-18Sl.
( i
V�b
I
II`'BY ER®
i
AUG 01 20118 '
E
EXTERIOR RESEARCH & DESIGN, LLC.
ST. Lucie County, Permitting
FL CERTIFICATE OF AUTHORIZATION#9503
RE: East Coast Metals, Inc.
East Coat Metals Channel Metals
6"' Edition (2017) FBC HVh1Z
Affirmation of FL5374-R4
FILE
d� WEALED FASTENERS OR ATTACHMENTS
RITHE
60 AREaHERESP RORECORD.
v It3EE1NrRAGTOR OR RECORR D.
To Whom It May Concern:
This letter serves to document that we have reviewed Florida Product Approval File No. FL5374-R4,
and the Evaluation Report which forms the basis thereof, with respect to the 6 h Edition (2017) Florida
Building Code, High Velocity Hurricane Zone sections set forth in Section 2 of our Evaluation Report.
There are no changes to the Code that affect the Evaluation Report, and we have authorized the
applicant, East Coast Metals, Inc., to document compliance with the 6`s Edition (2017) Florida Building
Code, HVHZ through the Affirmation Process.
Please contact our Connecticut office with any questions.
Respectfully submitted, �E'R► I6oB -Do I C)�.u�r(.
%. �--� ST. LI c. COUNTY BUIL DIVISION
-- -REVIEWED FOR COMPLIANCEI/ i . j
ert Nieminen, P.E. rc�vlf u r y
President DATE
ja Reg. No. 59166 PLANS AND ER IT MUST BE KEP N JOB
SITE OR NO INSPECTION(S) WILL BE MADE
rYniaminanin�trinitvPrrl rnm
IFICATION OF INDEPENDENCE:
Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
Robert Nieminen, P.E. does not have, norwill acquire, a financial interest in any other entity involved in the approval process of the
product.
This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ON OFFICE:
)NNECTICUT:
BORATORY:
BUILDING SCIENCE RESEARCH I DESIGN I CONSULTATION
80 YESLER WAY, SUITE 200 1 SEATTLE, WA 98104 I TEL: 206 467 0054 I FAX:206 267 0267
353 CHRISTIAN STREET, UNIT 13 1 OXFORD, CT 06478 I TEL: 203 262 9645 I FAX: 203 262 9243
10 MAUNEY COURT I COLUMBIA, SC 29201 1 TEL: 803 989 8133 I FAX: 803 988 BI I I
1
TRaNl ! ERD
EXTERIOR RESEARCH & DESIGN, LLC:
Certificate of Authorisation //9503 ;
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
EVALUATION REPORT
East Coast Metals, Inc. Evaluation Report E10240.08.08-R4
Hialeah, FL 33010 Date of Issuance: 09/03/2008
Revision 4: 03/17/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction, materials; in,the.State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use ;;of the pr..o.dt ct•.u,nder the Florida Building Code and Florida Building Code,. Residential Volume. The products described
;herein.have been'evalbated for compliance with the 5'' Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced,,
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed it
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of :this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
RobertJ.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
rc
' The facsimile seal appearing was authorized by Robert Nleminen,
P.E. on 03/17/201S. Thls does not serve as an etectronimliy signed
document. Stgned, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or,
distributing products it evaluates.
2. Trinity[ ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
i
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or design guidance unless retained
specifically for that purpose.
OOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.3.7 Installation, non-HVHZ FRSA/TRI April 2012 (04-12) 2012
1518.8.1 Installation, HVHZ RAS 118, 119 & 120 2995
1523.6.5.2.2 Static Uplift Resistance TAS 101 1995
1711.2.1 Static Uplift Resistance SBCCI SSTD 11 1997
3. REFERENCES:
knfiv I Examination Reference Date
ERD (TST6049) Static Uplift Resistance E42730.08.13 08/23/2013
ERD (TST6049) Static Uplift Resistance ECM-SC6795.12.14-1 02/27/2015
ERD (TST6C49) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2015
Florida TEC (TST7393) TAS 101 S10-628R 10/27/2010
PRI (TST5878) TAS 101 ECM-001-02-01 09/21/2001
PRI(TST5878) TAS 101 ECM-003-02-01 06/13/2008
PRI (TST5878) TAS 101 ECM-004-02-01 06/13/2008
PRI(TST5878) TAS 101 ECM-005-02-01 06/13/2008
PRI (TST5878) TAS 101 ECM-006-02-01 06/13/2008
PRI (TST5878) TAS 101 ECM-007-02-01 06/13/2008
PRI (TST5878) TAS 101 ECM-008-02-01 06/13/2008
Florida Building Code Attachment Requirements FRSA/TRI.April 2012 (04-12) 04/2012
Florida Building Code - HVHZ Attachment Requirements RAS 118,119 and 120 1995
East Coast Metals Metal Quality Mill Certifications Various
Architectural Testing (QUA1844) Quality Control Participation Letter Exp.12/31/2018
L PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles A_Z�
are bonded in FBC Approved roof tile adhesive.
Hip & Ridge Channel Metal is available in 119=3/8-inch3/8-inch) length by 2.5, 3, 3.5, 4, 5, 6 or 7-inch (±3/8-inch).................................------.heights..with-l.5=inch-L.1/16-inch).deck-flanges.—_.-._..-.._.._.._.._......_.._..__..._..__..._... ........... ..... ...,__............ _._............... ............ ..
Exterior Research and Design, U.C.
Cefdf cute ofAuthaflzatlan #9503
Evaluation Report E10240.08.08-R4
FL5374-R4
Revision 4: 03/17/2015
Page 2 of 7
�4 fTRINITY
4.2 Trim Lock Channel Metal: Pre -formed metal channel
designed for use as whip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel Metal is available in 119-3/8-inch (±
3/8") length by 3, 15, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.54nch (± 1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof tile adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(± 3/8") length by 3, 3.5, 4, 5 or 6-inch L+ 3/8-inch) heights
with 1.5-inch L 1/16-inch) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
I�
➢ Galvanized Steel: Min. 0.019±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
➢ Galvalume Steel: Min. O.019 ± 0.002-inch, ASTM A792, AZ55, min. 35 KSI.
➢ Aluminum: Min. 0.032±0.002-inch, ASTM B209, 3003-1-114, min. 21 KSI.
➢ Stainless Steel: Min. 0.019 ± 0.002-inch, ASTM A240/A48O, T304, min. 35 K51.
I
5. UmITATIONS:
i
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of,
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting orl
design guidance unless retained specifically for that purpose.
i
Exterior Research and Design, I.I.C.
Certificate of Authorization p9503
I
I
Evaluation Report E10240.08.08-R4 ,
F.L5374-R4
Revision 4: 03/17/2015
Page 3 of 7
v
i
TRINITY I ERD
5.2 FOR HVHZ JURISDICTIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,) or uplift resistance (F,),
as determined in accordance with RAS 127, not greater than the following values.
Refer to the tile adhesive manufacturer's published installation instructions for adhesive paddy placement details.
➢ "INDEPENDENT” paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part the adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
L . PERFORMANCE LIMRATIONS- HVHZ INDEPENDENT PADD .PLACEMENT ,.,::: a':` :r= "=?'•
, Y.
Y.
TO MARGINO ETVA ... ..:..... ...: FSAF LREADYAPPLIED
'
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mr (ft-lbf)
F' (Ibf)
Hip & Ridge
galvanized
clay or
3M'" 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AH-160
Trim Lack
galvanized, Galvalume',
clay or
31VITM 2-Component Foam
Independent
171
159
aluminum or stainless steel
concrete
Roof Tile A&l iveAH-160
Trim Lock Plus
galvanized, Galvalume',
clay or
3MTM 2-Component Foam
Independent
177
165
aluminum or stainless steel
concrete I
Roof Tile AdhesiveAH-150
_
ABLEV ERF.ORMANCELIMRATIONS-.Hv HZ'INTERDEPENDENTPADDYPLACEMEg.
r 4T01MARG/N OFSAFETYAlREAOYAPPUED :..:. •C '
._.
- _ . ...... ... .._. .. ..: .. . ..... _.,...,... ......_:.. .<-''
. ,.....a,:...u..,:�.:,..._.,<.-....: ,. ,..:.". :....... .... �,..:...� <,.. ..
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment Based
Uplift Based
Mr (ft-Ibf)
F' (Ibf)
Trim Lock or Trim
galvanized, Galvalume®,
clay or
3MTM 2-Component Foam
Lack Plus
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
Interdependent
95
88
Trim Lock
galvanized, Galvalume®,
clay or
3MTM Roof Tile Adhesive
Interdependent
99
94
stainless steel
concrete
RTA-1
Trim Lock
aluminum
clay or
3M'" Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-i
Trim Lock Plus
galvanized, Galvalume',
clay or
3M'" Foam Roof Tile
Interdependent
90
84
aluminum or stainless steel
concrete
Adhesive RTA-1
rim Lock
galvanized, Galvalume' or
clay or
TILE BOND— Roof Tile
Interdependent
123
117
stainlesssteel
concrete
Adhesive
rim Lock
aluminum
clay or
TILE BOND'" Roof Tile
Interdependent
79
73
concrete
Adhesive
IIII
Trim Lock Plus
galvanized, Galvalume',
clay or
TILE BOND'" Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
rim Lock
galvanized, Galvalume' or
clay or
Touch'n Seal Stormeond '
Interdependent
146
139
stainless steel
concrete
Roof Tile Adhesive
rim Lock
Aluminum
clay or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof Tile Adhesive
rim Lock Plus
galvanized, Galvalume®,
clay or
Touch'n Seal StormBond
Interdependent
58
54
aluminum or stainless steel
concrete
Roof Tile Adhesive
Exterior Research and Design, U.C.
Certif{cate of Authorization N9503
Evaluation Report E10240.08.08-R4
FL5374-R4
Revision 4: 03/17/2015
Page 4 of 7
,. TRINITY,ERb
5.3 FOR NON-HVHZ JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lock Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
hssive-manufa-cturel'3IiQislishe-i Insta lation instructions tor adhesive pa y p acement details.
"INDEPENDENT" paddy placement means parh indivirliml tilp is hnnrlarl to the rhanpal M®tal in its 9WR, SIR&
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual the is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
' %, :::TABLE.TA: PEHFORMANGEII ITATIONS..'.?NON �IVHZ `INDEPENDENT PADDY PUICEME T. i :' :..'c i '. `; :`:: ?• ':i•:: `:<
a..
SAFE7YAUtGiIDYiIA•ED
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Hip & Ridge
galvanized
clay or
3MTM 2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume®, aluminum or
clay or
3MTM 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
T3M- 2-Component FoamIndependent
178
stainless steel
concrete
ile Adhesive AH-160
T B:
ALE2B:-'PERFaRMA .CE:LINIRAT101115-NON= VHZ'?1NiERDEPENDEN'f'P H ADDY PLACEMEM.'
SAF ALREADY' PPUED ..
Hlp/Ridge Metal
Tile
Adhesive
Allowable i
Design
Metal Type
Type
Placement
Trim Lock or Trim
galvanized, Galvalume®, aluminum or
clay or
3MTM 2-Component Foam Roof
Lock Plus
stainless steel
concrete
Tile AdhesiveAH-160
Interdependent
98
Trim Lock
galvanized, Galvalume® or stainless
clay or
3MTM Foam Roof Tile Adhesive
steel
concrete
RTA-i
Interdependent
110 i
Trim Lock
aluminum
clay or
3MTM Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
3MTM Foam Roof Tile Adhesive
stainless steel
concrete
RTA-1
Interdependent
93
i
Trim Lock
galvanized, Galvalume® or stainless
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
152
steel
concrete
Trim Lock
aluminum
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Pius
galvanized, Galvalume°, aluminum or
clay or
TILE BOND- Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
Trim Lock
galvanized, Galvalume® or stainless
clay or
Touch'n Seal StormBond Roof
steel
concrete
Tile Adhesive
Interdependent
148
Trim Lock
Aluminum
clay or
Touch'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
galvanized, Galvalume®, aluminum or
clay or
Touch'n Seal StormBond Roof
Interdependent
61
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, I.I.C. Evaluation Report E10240.08.08-R4 '
Certificate ofAuthorizallon #9503 FL5374-R4
Revision 4: 03/17/2015
Page 5 of 7
A
- l
1'
T��IYi ERD
f$
6. INSTALLATION:
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ.
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1X-inch long x 3/8-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges. Fasteners shall be
positioned %-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RAS 118; Drawing 13; Detail 3; RAS 119, Drawing 12; Detail 3; or RAS'120; Drawing 15; Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lock Plus Channel Metal Installation
6.3.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
........ ....... ....._... .....useof the -subject tile adhesive:."-1........ ----- ...... ......... .._..-_..-._...... _............. ....... .... ................. _.-------................................. ...._._...... ... ................... -------................. ........
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-114
CerHicate ofAathorhation #9503 FL5374-R4
Revision 4: 03/17/2015
Page 6 of 7
• `\ J TRINITY I ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the tile adhesive manufacturer's Approved, publishi d
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements. '
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
i
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after Weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance prior to placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc. — QUA1844; (717) 764-7700
- END OF EVALUATION REPORT -
t
Exterior Research and Design, U.C. Evaluation Report E10240.08.08-R4 ,
Certificate ofAvthorization #9503 FL5374-R4
Revision 4: 03/17/2015