Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
EVALUATION REPORT
SCANNED BY St. tuwe Coon e Fi ' ALUATION REPORT e Roofing Products Florida LLC. East Country Road 470 Orville, FL 33585 400-3245 RECEIVE® EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 AUG O 201� 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 F__Lucie County, P�rrmlttlnq ^ (203) 262-9245 Evaluation Report E1322.09.06-115 FL7473-R8 Date of Issuance: 02/24/2009 Revision 5:10/16/2017 )PE: s Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of istruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, . for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The (ducts described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code HVHZ) sections noted herein. : Eagle Roof Tiles LING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced duality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of t is Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product c anges or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this EII aluation Report relative to updated Code requirements with each Code Cycle. I VERTISEMENT: The Evaluation Report number preceded by the words "Evaluated by Robert Nieminen, P.E." may be drlsplayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its ditirety. I IIn�SPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. is Evaluation Report consists of pages 1 through 5. spared by: t J.M. Nieminen, P.E. Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/16/2017. This does not serve as an electronically signed document. Signed, sealed hardcopies have been transmitted to the Product Approval Administrator and to the named client IFICATION OF INDEPENDENCE: TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. This is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ii TTRJN1TYJEkb1' I! ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Eagle Roof Tiles, as produced by Eagle Roofing Products Florida LLC, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code (NON-HVHZ) through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.3.5, R905.3.5 Physical Properties ASTM C1492 2003(2009) 1507.3.7, R905.3.7 Attachment Requirements FRSA/TRI April 2012 (04-12) 2012 1504.2.1.1 Overturning Moment SSTD 11 1997 3. REFERENCES: Enti Examination Reference Date ATL(TST 3782) ASTM C1492 RT0310.01-17, 02-17, 03-17 03/15/2017 ATL (TST 3782) ASTM C1492 — Freeze/thaw RT0706.01-17, 02-17, 03-17 09/25/2017 Tile Roof Institute SSTD 11 Membership Letter 11/29/2005 ATI (QUA 1844) Quality Assurance Inspection Report 06/07/2017 4. PRODUCT DESCRIPTION: 4.1 ASTIVI C1492;,Tvpe ll1(Low Profile):., . w, h.. , ,.a.., BELA R ,.. A Exterior Research and Design, L.I.C. 0 EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-R5 Certijlcate ojAuthorization a9sm Eagle Roofing Products Florida LLC.; (800)`400-3245 FL7473-R8 Revision 5:10/16/2017 Page 2 ofB ��TRINITYJERD 4.2 ASTM C1492, Type 11 (Medium Profile):, NAIL 'HOLE 4.3 I ASTWC1492• Type I (High Profile):,` LIMITATIONS: 5.1 This is a building code o evaluation. Neither Trinity IER nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project hich this aluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification is not part of this evaluation; refer to FBC 1505.2, Exception 2 (for non-combustible deck) or listing by an approved testing agency for fire rating of this product. 5.4 Underlayment shall be that which holds Florida Product Approval for use with tile roofing systems. The underlayment Product Approval shall specify allowable method(s) of tile installation (mechanical attachment, mortar -set and/or adhesive -set) for use with the specific underlayment. For mortar -set or adhesive -set tile roofing applications, the underlayment Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 5.5 "Color -Bonded" or "Slurry -Coated" files are limited to use on projects in areas subjected to weathering indices of 50 or less (negligible weathering), as outlined in Figure 1 of ASTM C1492-03(2009)1, reproduced below for reference. This limitation does not apply to the "Color -Through' product offering. 5p, MEATHEMWd RE416N4. NEGL , ALE NEAfHERING` M.OD:ERATE WEAiTHE;RIN;GY [ `-} S:EVE`RE W.EATHEfi"7,N,G: 5.6 All products in the roof assembly shall have quality assurance audit in accordance with FAC Rule 61G20-3. Research and Design, U.C. 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-RS r ojAuthoriration #9503 Eagle Roofing_ Products Florida LLC.; (800) 460-3245 FL7473-R8 Revision 5:10/16/2017 Page 3 of 5 T�TwNITYJER'b 6. INSTALLATION: 6.1 Eagle Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of FBC 1507.3 and the FRSA/TRI Florida High Wind Concrete and Clay Tile Installation Manual. 6.2 Underlayment shall be installed in accordance with FRSA/TRI April 2012 (04-12) or the underlayment manufacturer's current Product Approval. For mortar -set or adhesive -set tile roofing applications, the underlayment current Product Approval shall specify attachment methods for the underlayment system to resist wind uplift design loads in accordance with Table 1A of FRSA/TRI April 2012 (04-12). 6.3 Tile Attachment: 6.3.1 Mechanically Attached Tile: Wind load resistance shall be in accordance with Table 3 of FRSA/TRI April 2012 (04-12) to resist the Uplift Moment determined in Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3. 6.3.2 Mortar -Set Tile: Wind load resistance shall be in accordance with Table 2A or 2B of FRSA/TRI April 2012 (04-12) or FBC 1609.5.3 in conjunction with the mortar manufacturer's Product Approval. 6.3.3 Adhesive -Set Tile: Wind load resistance shall be in accordance with Table 2A or 21B of FRSA/TRI April 2012 (04-12) or FBC 11 1609.5.3 in conjunction with the adhesive manufacturer's current Product Approval. Refer to the current version of the referenced Florida Product Approval for paddy -placement details and performance data.; , 6.3.4 TILE ADHESIVES FOR ADHESIVE -SET TILE SYSTEMS Manufacturer Products Florida Product Approval DAP Foam, Inc. "Touch N' Seal Storm Bond" FL14506 "Touch N' Seal Storm Bond 2" FL21374 Dow Chemical "TILE BOND"" FL22525 ICP Adhesives & Sealants, Inc. "Polyset® AH-160" FL6332 "Polyset® RTA-1" FL6276 Hip and Ridge Tile: Tile shall be installed in accordance with FRSA/TRI April 2012 (04-12). For hip and ridge tile installatillilns atop hip and ridge metal, refer to the hip and ridge metal manufacturer's current Product Approval (e.g., FL5374) or test report in accordance with SSTD 11 for allowable loads to resist those determined'in accordance with Table 1A of FRSA/TRI April 2012 (04-12). Exterior Research and Design, I.I.C. e" EDITION (2017) FBC NON-HVHZ EVALUATION Evaluation Report E1322.09.06-115 certificate afAuthori:ation #gs03 Eagle Roofing Products Florida LLC.; (800) 400-3245 FL7473-118 Revision 5:10/16/2017 Page 4 of S. QOTRINIT'YIERD LABELING: 7.1 Each unit shall bear the imprint or identifiable marking of the manufacturer's name or logo. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. MEMO E A-1 GL E 0 FLORIDA EAGLE FL (LOCATED ON UNDERSIDE OF TILE) (LOCATED ON FRONTSIDE OF TILE) 7.2 Tile not tested for freeze -thaw shall state clearly that the lot has not been tested for freeze -thaw acceptance on all lot tags or certification. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Sumterville; FL _ QUALITY ASSURANCE ENTITY: Architectural Testing, Inc. — QUA1844; (717) 764-7700 - END OF EVALUATION REPORT - ASTM C3492-03, Standard Specification for Concrete Roof Tile, © ASTM International Research and Design, U.C. CH EDITION (2017) FBC NON-HVHZ EVALUATION ofAuthori:ation #9503Eagle Roofing Products Florida LLC.; (800) 460-3245 Evaluation Report E1322.09.06-R5 FL7473-R8 Revision 5:10/16/2017 Page 5 of 5