Loading...
HomeMy WebLinkAboutENGINEERINGFL l �E .A SCANNED ENGINEERING & TESTING, INC. a LMa�11 Phone: (866) 781-6889 *Fax: (866)184-8550 , ivw.tloridaengineeringandtesting.com A�� t 9fj vv 250SM. 13`"Avenue i.ST. Pompano Beach, FL 33069 Lucie County, Permitting DATE: 7/31/18 JOB ORDER #: 18-3089 CLIENT: Tradewinds Roofing, Inc. ADDRESS: PO Box 13208 Fort Pierce, FL 34979 PROJECT: Mark Kicklighter Residence Flat Wood Non -Insulated Deck ADDRESS: 2710 S: 28111 Street Fort Pierce, FL 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Project Information: Height = 12' Exposure: C Basic/Ultimate Wind Speed: V„1r=170 mph q2 Length = 22' Category: H Nominal Wind Speed: V.d=V„ it*�0.6 a Width = 15' Slope: < 7° (asd = allowable strength design) Parapet Wall: N/A Residential KZ = 0.85, Kzt =1.0, Ka = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*KXztKdV2 Velocity Pressure („ it): q=0.00256(0.85)(1.0)(0.85)(170)2 = 53.45 psf Velocity Pressure (.d): q=0.00256(0.85)(1.0)(0.85)(170*g0.6)2 = 32.07 psf Width of Pressure Coefficient: 0.1(1 T) = 1.5' 0.4(12') = 4.8' } use: 3'0" Effective Wind Area: <l W For parapet height three feet (3') or larger, zone three (3) shall be treated as zone two (2). External Pressure Coefficient: 1) GCP1 = -1.0 2) GCP2 = -1.8 3) GCP3 = -2.8 Internal Pressure Coefficient: 1) GCPi = 0.18 �01 '-ate %. QU1 Quality. Ar iy ✓lssrcrance y Page 2, 7/31/18, Job Order #1_ - _i89 - Tradewinds Roofing, Inc. `LO Mark Kicklighter Residence Flat Wood Non -Insulated Deck 2710 S. 28th Street; Fort Pierce, FL: Design Pressures Based on Vasd: 1) Field P1 = 32.07*[(-1.0) — (0.18)] _ -37.8 psf 2) Perimeter P2 = 32.07*[(-1.8) — (0.18)] _ -63.5 psf 3) Corners P3 = 32.07* [(-2.8) — (0.18)] _ -95.6 psf Attachment Requirements Per RAS-117: Based on the requirements of Florida Product Approval # FL1046-R8, Appendix 1, Page 6 of 22, System No. W-11, with a maximum design pressure of-52.5psf, the following are our recommended fastening patterns to attach the proposed two plies of PermaPly 28 or Ventsulation base sheet to the minimum 19/32" plywood deck utilizing approved 11 ga. annular ring shank nails and 32ga., 1-5/8" diameter tin caps: Field: 9" o.c. @ 4" laps and 2 staggered rows 12" o.c. Perimeter: 9" o.c. @ 4" laps and 3 staggered rows 9" o.c. Corners: 9" o.c. @ 4" laps and 4 staggered rows 9" o.c. Notes: Corners and perimeter area dimension shall not be less than a = 3'0" Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC and information provided by client. Client is responsible for verifying existing/proposed conditions/decks as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. \111I IIP Sincerely, ��� NLAN w. ,.- � icEiy ••••sue /i 4642 Mark A. Mesi P.E. Florida Engiri &S'Y41*60, Inca Florida Reg. -�So'8 Certificate of ////III111�`