HomeMy WebLinkAboutENGINEERING0310.170055.0000
UNIVERSAL DateTypedt No.: September 11, 2018
ENGINEERING SCIENCES `��a /�
Consultants In: Geotechnical Engineering • Environmental Sciences Ul�J1i N `�fl FED
Geophysical Services Materials Testing • Threshold Inspection
Building Code Administration, Compliance Inspection & Plan Review
820 Brev rd Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Construction Materials Testing Services RECEIVED
FIELD AND LABORATORY REPORT COVER PAGE
SEP 19 2018
Client: Ryan Homes
1450 Centrepark Blvd Suite 340 ST. Lucie County, Permttkin9
West Palm Beach, FL 33401
Project: Oakland Lake Estates Subdivision House Lot Investigation Lot11 I$08
-oaoZ.
5352 Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
As requ sted, Universal Engineering Sciences, Inc. (LIES) representative(s) performed construction materials testing and/or
field insR� ection services on the above project. Testing results and/or inspection observations are reported on the attached
sheets. Jjfhe contents of this package are summarized below:
SCODe of Work
Work O?,#er No.
Date
Type of Report
6633 -1
10/11/2017
In -Place Density Test Report w/Activity Record
1005p 0-1
09/13/2018
Activity Record
I
We hopg this information is sufficient for your immediate needs. If you have any questions, please do not hesitate to contact
the und8rsianed.
�to� v gg�nc z7o
O�
`:cn:n�
�SS+iii —
`L
A
, o
gag
�g B
°tea =• � iA
W
•
• m' .�.
90 A
M
�y N sn
Z
in
0
o��
in �fd
O
�I'o o�C
��m
V
C m
�__ CL O Gmp'.
Z��n moo- oo..
vs
°'$�'�•� a
in� r*
fD o
ICC Ern : jomcalli@nvdnc.com; tridley@nvrinc.com
FILE COP �
Sincerely,
Universal Engineering
Sciences, Inc.
Certificate of Authorization No. 00000549
Richard E.
Hoaglin, P.E.
2018.09.13
16:50:48
-04'00'
Richard E. Hoaglin, P.E.
FLORIDA
Professional Engineer No. 48796
UNIVERSAL.
UES Project No: 0310.1700455.0000
UES DOCS No:
UES Report No: 66331-1 ARC 101117
ENGINEERING SCIENCES On -Site Time (hrs): 0.25
Consultants In: Geotechnical Engineering a Environmental Sciences; Lab Time (hrs): 0.00
i Geophysical Services • Materials Testing Threshold Inspection Travel Time (hrs): 0.25
Building Code Administration; Compliance Inspection & Plan Review Total Time (hrs): 0.50
820 Br, vard Avenue, Rockledge, FL 32955 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Projec : Oakland Lake Estates Subdivision House Lot Investigation
Oakland Lake Circle , Ft. Pierce, St. Lucie County, FL
Date I Activity: Wednesday, 11 October, 2017
Tecnq cian: Cliff Cherrnay
As req i ested, a Universal Engineering Sciences Technician was present at the above referenced project site for the
purpos of earthwork testing for Lot 11.
DENSI TEST
While - n site, the technician observed the general condition of the areas to be tested and performed 1 density test for Lot 11
at 535 Oakland Lake Cir. This test was performed in accordance with the ASTM D-6938 Nuclear Gauge Method and
found t, meet the project compaction requirements of 95% of the maximum dry density per ASTM D-1557.
BEAR �IG CHECK
Tech
ni ian also hand augered to a depth of 5' and organic material was found at the 1' depth. This material is unsuitable and
shouldl�e removed prior to construction.
U..N*l VERSAL
ENGINEERING SCIENCES
.Consultants In; Geotechnical Engineering • Environmental Sciences
Geophysical,5ervices • Materials Testing s Threshold Inspection
Building-CodeAdministration_,.Compliance Inspection Si Plan Review
820 Bre4rd Avenue, Rockledge, FL 32965 - P: 321.638.0808 - F: 321.638.0978
UES Project No: 0310.1700455.0000
UES DOCS No:
UES Report No: 66331-1 DT 101117
In -Place Density Test Report
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Projec : Oakland Lake Estates Subdivision House Lot Investigation
Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
Area Tested: Lot 11
Type o Test: Field: ASTM D-6938 Nuclear Gauge Method Date of Test: 10/11/2017
II Lab: ASTM D1557 Modified Proctor
Technj;cian: Cliff Cherrnay
Requiements: 95% of Proctor maximum dry density. These tests apply to the fill and/or surficial soil conditions
II only and do not address the condition of the underlying soils below the tested depths.
Field Dry
Field
Test
Depth
Proctor
Density
Moisture
%
Comments
No.
Location of Test
Range
(inch)
(2)
(PCF)
1
%
Compaction
(3)
1
L t 11
0-1 ft
12.00
7492
114.5
11.8
99
A
(1) R f. Datum: 0 = Top of Final Grade
(2)
Maximum
Optimum
Proctor
Dry
Moisture
#
Density
Content
7424
115.0
12.0
(3) Comments Key
A. Compaction meets min. requirements
B. Compaction does not meet min. requirements
C. Moisture does not meet requirements
D. Recompaction required
E_ Recomoacted. Retested. Meets Reauirements
j
UES Project No: 0310.1700465.0000
UNIVERSAL UES DOCS No:
UES Report No: 100650-1 ARC 091318
ENGINEERING SCIENCES On -Site Time (hrs): 0.26
Consultants In: Geotechnical Engineering • Environmental Sciences' Lab Time (hrs): 0.00
Geophysical Services a Materials Testing i Threshold Inspection Travel Time (hrs): 0.26
Building Code Administration; Compliance Inspection & Plan Review Total Time (hrs): 0.50
820 Brqe and Avenue, Rockledge, FL 32966 - P: 321.638.0808 - F: 321.638.0978
Activity Record
Client: Ryan Homes
1450 Centrepark Blvd Suite 340
West Palm Beach, FL 33401
Projec : Oakland Lake Estates Subdivision House Lot Investigation
Oakland Lake Circle, Ft. Pierce, St. Lucie County, FL
Date otct
ivity: September 13, 2018
Technn: Cliff Cherrnay
As req sted, a Universal Engineering Sciences Technician was present at the above referenced project site for the
purpos! of earthwork testing for Lot 11.
BEARI IG CHECK
Technid an revisited site to verify that the debris had been removed. The fill soils appear to be suitable.