Loading...
HomeMy WebLinkAboutBUILDING PLAN PAGE 32-3638'-8" 8'-4" 8'4" 11'-8" 10'4" KN KA 4 7[= .z O KA 0 0 00 .,OPENKA M 0 0 10'-0-3/4" TOP OF DECK 0 ti 4'-4„ 9, 8„ 7,_4„ 3'-4" 7'-0" 7'_0" 21'-4" 17'_4" 38'-8" SECOND FLOOR PLAN SCALE: 1/4 = 1'-0" 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F hW 04 U W 0 tj tQ q Iq ti h SVBDIV. de LOT: CREEKSIDE LOT #11 PROJECT# 04321.000 011R3 W0DEL: 4EGB "GALEN" GARAGE S WING: RIGHT PAGE: SECOND FLOOR PLAN & NOTES ,oh160 MPH EXP. C ARCHTECT- STATE OF FLOEM DRINT A E. 07/12/18 SCALE: 1/4"=1'-0" SHEET S 28'-0" 24'-0" 20'-0" 16'-4" 4'-0" ro i� C9 M 4 0 N 4 io N O iM IM o0 i N 0 N 0 0 ° o 4'-T 7'-4" c- 0 i- 14'_4„ 0 7,_$„ 13'-8" 17'-4" SECOND FLOOR DOWEL PLAN SCALE: 1/4" = 1'-0" 1441 N. RONALD REAGAN BLVD. LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F Chi r4 "".. 0 W A E x •r :317331)Iv. & LOT: CREEKSIDE LOT #11 PROJECT* 04321.000 011R3 MODEL: 4EGB "GALEN" GARAGE SWING: RIGHT PAGE: SECOND FLOOR DOWEL PLAN (160 MPH EXP. C AFtaF F F STATE ODA C.IUL 1 2 8 D TE 07/12/18 SCAL.'e : 1/4"=1'—O" S4.2j FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: USP DTC Wl (13) 10d x 1 1/2" HDG NAILS. SMALL JACKS < 9' MAY BE NAILED W/ (10)d x 1 1/2" HDG NAILS, CONCRETE TO WOOD FLOOR: USP LPTA W/ (10) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD: USP RT16A OR LUGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS 1 ARE TO BE GALVANIZED. 2 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL 7, 0„ 7' 2' Ir MANUFACTURER SHOWN IN STRUCTURAL PLANS. , ,. AIN, V ,tl� z 1� M� AM _9 W.. MM 4( � �� � � � � « m , 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND 8F16-lT/0M/0B 8F16-1 /0M/06 8F16-1T/OM10B CLEAR SPAN OPENINGS. F 7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4'). z. � 8. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS Ilk Y$ ,1 LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND %F 21' N APPROVAL. awl,40 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WTH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END` UNLESS OTHERWISE SHOWN DIFFERENT. (; 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. ?' 12. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS LuNO, PROVIDE BB1` NOTED OTHERWISE. I) WHERE ROOF 1061 All" TRUSSES BEAR, 011' L TOP OF WALL, EL.'m�`1 18'-8" LINO 410 qq° 01 Ilk, � '.WWI pSFdY bSYb �m'1 nUdYW (M1YNN 11N%� b BEAM SCHEDULE '",,, INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / &O.L. = BOTTOM OF LINTEL / T.O.A. = TOP OF ARCH / T.O.S = TOP OF SLAB � 4` ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT *41 REINFORCEMENT STIRRUPS . MARK DESCRIPTION fc (psi) SIZE W'xH' REMARKS — R) % ) 1 7 BTM. TOP MID SIZE SPACING 11141 BB1 MASONRY 3000 8x8 — (1) #5 — N/A N/A GROUTED SOLID % BB2 MASONRY 3000 8x16 — (1) #5 (1) 45 N/A WA GROUTED SOLID 3r iy' 61 I;) % ° % "CAST-CRETE" SAFE LOAD TABLES _ 10 < SAFE LATERAL LOADS FOR ) < 8F16-lT/0M/0B 81`16-1T/OM/013 SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS 8" PRECAST & PRESTRESSED U-LINTELS SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS )` GT SAFE LOAD �weti�n SAFE LOAD - POUNDS PER LINEAR FOOT �1er.�A�w PLF SAFE LOAD -POUNDS PER LINEAR FOOT L ,,,,,, „tl, ,,,,, ,,,,M 110 :,,,,, AM, 10� ,,,,, ,. �. „,M; ,,,,,v ,*N -9911.11 ; >,, ,h, ,,, � u TYPE 8F8-0B 8F12-0B BFi6-OB BF20-OB BF24-OB BF26-OB BF32-0B TYPE RCMU TYPE BFB-0T 9f12-iT BFi6-1T 8F20-iT BF24AT 8F28-iT BF32-1T GT '��`, LENGTH SUS BFB-1B 8F12-1B 8F16-1B BF20-1B BF24-18 8F21-18 BF32-1B LENGTH SUS 8F8 LENGTH 8F6-2T BF12-2T 8F16-21 BF20-2T BF24.2T 8F28-2T 8F32-2T h 3069 3719 5163 6607 6654 9802 10951 1 3'-6" PRECAST 1025 1024 1598 1569 2655 3524 439a 5263 6132 7001 ,011," `1Qp 3'-6" (42") PRECAST 2231 3069 4605 6113 7547 8974 19lf,4 11809 (42') 3'-6" (42") PRECAST 1569 2655 3524 4394 7001 �11, % 2561 2751 3820 4890 5981 701 8107 1383 2305 3060 3615 5263 4570 6132 5325 6079 9 4'-0" (48') PRECAST 1966 2693 4605 6113 7547 8974 10N4 11609 4'-0" 48' PRECAST ( ) 765 763 1309 4'-0" (48") PRECAST 1363 2305 3060 3815 4570 5325 6079 IA f $�, 4'-6" (54") PRECAST 1599 1969 2189 2110 4375 2931 6113 3753 7547 4576 8672 59P0 10LC� 6224 11809 4'-6" (54') PRECAST 592 591 1073 4'-6" (54") PRECAST 1207 1207 2040 2040 2707 2707 3375 4043 4711 5379 ' �,pdx^^� ."'0 ,< 8F16-lT/OM/OB 8F16-lT/OM/OB 1349 1438 1999 2560 3123 3B� 4249 1016 171 n 2276 3375 2838 4043 3399 4711 3961 5379 4522 "1' 5'-4" (64') PRECAST 1217 10127sd 5'-4" (64") PRECAST 411 411 745 5'-4" (64') PRECAST10 a s 1 1883 3090 5365 7547 7342�s� 67�3ns7 1016 1715 227E 2838 3399 3961 4522,,E `R 1105 1173 1631 2090 71A9 mom 3470 or>A ASR�.,., e b. dump awv ,ry r „ euva fdv ,N, e,u wu'tw m aw sw.a rav4 �-z,�s �z: awx am v nwt, SECOND FLOOR LIFT BEAM PLAN SCALE: 1/4" = l'-O" 1441 N. RONALD REAGAN Bl LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com L AA #: 0003325 F W W 0 A 4 ti SUBDIV. ae LOT: CREEKSIDE LOT #11 PROJECT* 04321.000 011R3 MODEL 4EGB "GALEN" GARAGE STnNG: RIGHT PAGE: SECOND FLOOR LIFT BEAM PLAN 160 MPH EXP. C ARCHITECT- STATE OF FLORIDA J n TE:: 07/1 SCALE: 1/4" SHEET S51 FRAMING NOTES 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: USP OTC W/ (13) 10d x 1 1/2" HOG NAILS. SMALL JACKS < 9' MAY BE NAILED W/ (10)d x 1 1/2" HOG NAILS, CONCRETE TO WOOD FLOOR: USP LPTA W/ (10) 10d x 1 1/2" HOG NAILS, WOOD TO WOOD: USP RT16A OR LUGT2 W/ 10d x 1 1/2" HOG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS 0E AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED, 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON LINTEL MANUFACTURER SHOWN IN STRUCTURAL PLANS, 6. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 7. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 8. THE TRUSS FRAMING SHOWN IS, SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 9. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 10. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 11. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS, 12. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS, 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. COLUMN SCHEDULE MARK SIZE & BASE PLATE OR REMARK DESCRIPTION REINFORCEMENT 4x4 (3 112"x3 1/2") USP PAU44 W/ 5/8" DIA. x D SYP. PT, WOOD POST 6" EXP. BOLT No D2 DOUBLE STUD 4x6 (3 1/2"x5 1/2") USP PAU46 W/ 5/8" DIA. x D3 SYP. PT; WOOD POST 6 L EXP. BOLT s 2-PLY U: -3104 LBS 1-PLY G: 5272 LBS U: -541 LBS 2A G: 1333 LBS 3.1 , 1 A �— S3.1 in 2-PLY U:-1836 LBS G: 2965 LBS 1C T-0" m DIAGONALS FOR BOTTOM CHORD BRACING @ 20'-0" O.C. MAX (TYP.) U:-757 LBS G:1962 LBS 1A 2-PLY U:-1862 LBS G: 3019 LBS II It II II 11 11 II II II II li II II II II �i 111 II II II II O 11 - II II II II II II II II � N II II II 1 1 - ,y� I I co I u u u u u � � 6 II Au n nmu-�II IIII II 31 n u u�\e it Lu a� u u u u u un 11 II II II II II II II /I� II II I II ioUto IRIDGE � II II II Il_ JI II u u u u II II II It I II 'SjQ II II II II - u u n u II II II I �� n w u a �yl a li u II II II II II II II i� I II I II II II GT tijA 53.1 = II II II II II II II = 2-PLY U: 5913 LBS G:10879LBS ROOF FRAMING PLAN SCALE: 114" = V-0" T-2" n II 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 F 04 W may.. O A ti sui33DIY. & LOT: CREEKSIDE LOT #11 PROJECT# 04321.000 011R3 adODEL: 4EGB "GALEN" GARAGE SWING: RIGHT PAGE: ROOF FRAMING PLAN 160 MPH EXP. C ARCHITECT STATE OF FLORDA JU 1 -20 ACRA NO 937 DA 07/12/18 SCALE: 1/4"=1'-0" SHEET kam 1..J GABLE - E'L7 •# jri-#Y # # • : • : • :#7r#i-r Mr,►# #t r J • : • + : • Moi-W.4 • 1 • • 1 • So• • • • • • • • • • • • • • • #p� . 4 Yt•�� •_• •_•_• . • • • • • HIP ROOF ROOF WIND DESIGN PRESSURES NET(GROSS)! • • . • 39.48 •.8 • ! • ZONE BASIC WIND SPEED: •! MPH EXPOSURE:WIND RISK •' APPLICABLE COEFFICIENTPRESSURE ! ROOF DIAPHRAGM FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" O.S.B. OR 1/2" CDX EXT. PLYWOOD, FOR CEMENTITIOUS TILE AND METAL ROOFING, USE MIN. 5/8 CDX EXT. PLYWOOD, WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT SUPPORTED PANEL EDGES AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS. SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 8d GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4' OF GABLE END. GENERAL NOTES: ALL AGGREGATE USED IN CONCRETE: STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT pROMDE6°kAIR ENTRAINED CONCRET ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2017, 6th EDITION ALL EXPOSED EDGESOFCONCRETEA ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 530-13/ASCE 5-13 AISI SPECIFICATION FOR THE DESIGN OF PROVIDE 6-MIL CONTINUOUS POLYETH COLD -FORMED STEEL STRUCTURAL MEMBERS 2011, ASCE 7-10 AND AISC SPECIFICATIONS DRAWINGS. SEAMS LAPPED 61NCHES1 ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND FORM -WORK: SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, FORM -WORK, SHORING, AND BR EXCEPT WHERE DIFFERENT DETAIL IS SHOWN. AND FOOTINGS SHALL BE DESIG "RECOMMENDED PRACTICE FOF ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT EXCLUSIONS FROM TF TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART WATERPROOFING, FLASHING, S OF THE WORK. ARE NOT PART OF THE STRUCT ON THE TYPE OF CONSTRUCTIC THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS WELDED WIRE MESH: DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIE -DOWNS. WELDED WIRE MESH, SHALL BE TYPICAL DETAILS. MINIMUM LAP THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION SUPPORTED WITH 2" CHAIRS SF REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A615 GR ACCORDANCE W/THE TYPICAL DESIGN LOADS: SPECIFICATIONS. CONTRACTOR onQDIrATinni un0l7nKMAi AMr ROOF/ WALL/ FLOOR SHEATHING FASTENER SCHEDULE a ,,may=' •.,•s. NAIL SCHEDULE SIZE TYPE MIN. LENGTH MIN. DIA. SHANK TENSILE STR. SHANK 8d RING SHANK, 2 1/2" 0,120" 170,000 RING (16-20 RINGS SCREW SHANK PER INCH) 8d SCREW SHANK 2 1/2" 0.120" PNEUMATIC SCREW -NAILS I 1, NAIL SIZE PER ASTM F1664 2. INTERNATIONAL STAPE, NAIL & TOOL ASSOCIATION (ISANTA) ESR-1539 EXTERIOR SHEATHING USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SEE DETAIL. 8d RING SHANK GUN NAILS @ 4" O.C. ,. TOP & BOTTOM EDGES J ( z Z 0 ' IL z = rn U O J Z . CO z 00 Co z ao Y Z Q 2' 1n C . z Elf . -o 00 J Z� W = ui Y =U (n O O ,T z Ir 0000 J Z Y Q W co m U w, LU U��I Q O 2 00 W z o- TOP CORD BLOCKING AT 4' O.C. MAX IN FIRST 2 FRAMING SPACES AT EACH END. RAFTER .OR TRUSS ROOFSHEATHING -\ BUILDING LENGTH ROOF SHEATHING LAYOUT AND ENDWALL BRACING FOR GABLE END FRAMING C8d RING SHANK GUN NAILS 6" O.C. IN FIELD Cad RING SHANK GUN NAILS @ 12" O.C. IN FIELD or 8d x 2 1/2" SCREW SHANK PNEUMATIC SCREW -NAILS @ 17 0.6�N FIELD J\ TYP. 3/4" T&G SQb-rLUUK UtIRIIVI.i I.iLUtU IUALL thh'UJtU IVItIVItStKJ LL CONFORM TO ASTM C33. MAXIMUM AGGREGATE SIZE SHALL BE 3/4`. WOOD: XPOSEDTO EARTH OR WEATHER NON -BEARING WOOD WALLS TOP PLATES & STUDS CAN BE SPF. TO BE CHAMFERED 314'. ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BRACING, LEDGERS, BLOCKING, CRIPPLERS SILLS ETC. SHALL BE SOUTHERN PINE NO. 2 OR BETTER F = 10 PSI AND A MODULUS OF b 1 0 :NE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON ELASTICITY= 1,400,000 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL BE (SEALED WITH ADHESIVE TAPE. PRESSURE TREATED. PRESSURE TREATED BOTTOM PLATE REQUIRED. WOOD FOR NON-STRUCTURAL USES SHALL BE RATED TO RETENTION LEVELS OF 0.25 PCF OF A BORATE PRESERVATIVE TREATMENT: DISODIUM CORROBORATE TETRAHEDRAL (DOT). WOOD FOR STRUCTURAL USE THAT SHALL BE TREATED FOR ANY :ING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, REASON SHALL BE RATED TO RETENTION LEVELS OF 0.42 PCF FOR DOT OR MORE. NAILS, SPIKE, BOLTS USED _D AND CONSTRUCTED IN ACCORDANCE WITH ACI 347, W/ DOT SHALL BE HOT DIPPED GALV. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT ONCRETE FORM -WORK. CONTAINS MORE THAN 1/2" OF HEARTWOOD. .SE PLANS: MINIMUM NAILING PER FBCR 2017, 6th EDITION, SEE NAILING SCHEDULE ON PLANS. WD ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS AL PLANS ASTHEYARE NOT CONSIDERED TO BE STRUCTURAL.DEPENDING PROVIDE SOLID BLOCKING UNDER ALL POINT LOADS AND WOOD COLUMNS WITH 2x STRUCTURAL LUMBER THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. SYP #2. UNTREATED WOOD SHALL NOT BE IN DIRECT CONTACT WITH CONCRETE, SEAT PLATES SHALL BE PROVIDED AT BEARING LOCATIONS WITHOUT WOODEN TOP PLATES. 'TM A185, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE ACI WOOD TRUSSES: 1ALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL BE :ED 3'-0" OC, EACH WAY, TO BE DESIGNED AND FABRICATED IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATIONS FOR STRESS -GRADE LUMBER AND ITS FASTENINGS" BY THE NFPA. TRUSS DESIGNS SHALL BE SIGNED AND SEALED BYA PROFESSIONAL ENGINEER REGISTERED IN FLORIDA, SEE NOTED FOR SHOP DRAWINGS, CONNECTOR PLATES SHALL BEA MINIMUM THICKNESS OF 0.036"AND BE MANUFACTURED FROM STEEL HE 60 DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN MEETING THE REQUIREMENTS OF ASTM A446, GRADE A, AND SHALL BE HOT -DIPPED GALVANIZED. NDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND 1ALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO DESIGN, FABRICATE, AND ERECT WOOD TRUSSES IN ACCORDANCE WITH TPI-14. "DESIGN NATIONAL ROOF: LIVE LOAD FLOOR: LIVE LOAD 40 psf oUDJIZ .l COMMENTARYAND RECOMMENDATIONS FOR HANDLING, INSTALLATION BRACING METAL -PLATE -CONNECTED TYP. MIN LAPS SHALL BE AS FOLLOWS: 14 BAR - 25" #6 BAR - 36" WOOD TRUSSES. 20 psf TOP CHORD -non-concurrent #5 BAR - 30" #7 BAR - 42" 10 psf BTM CHORD -non-concurrent PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS TRUSS MANUFACTURER WILL PROVIDE CALCULATIONS INDICATING ADDITIONAL DEAD LOADS FOR THE ROOF FOR ADDITIONAL INFORMATION. LOCATIONS WITH GUSSETS, CRICKETS AND VALLEY LOCATIONS REQUIRING ADDITIONAL ROOF FRAMING FOR DEAD LOAD DEAD LOAD INTERSECTIONS OF HIGHER OR LOWER ROOFS IN ACCORDANCE WITH ANSI A58.1-1982. 15 psf TOP CHORD 20 psf TOP CHORD ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING, (7 psf w/ ASPHALT SHINGLES) (10 psfw/ No GYPCRETE) THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. 10 psf BTM CHORD 5 psf BTM CHORD MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE DEAD LOAD TO RESIST WIND UPLIFT: 10psf WALL. CONTRACTOR SHALL SUBMIT SIGNED AND SEALED DRAWINGS FOR ALTERNATE CONNECTION DETAILS AT BALCONY LIVE LOAD 60 psf TRUSSES/GIRDERS TO COLUMNS AND WALLS FOR APPROVAL. RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL WIND: DEAD LOAD SPEED =160 MPH 3- SECOND GUST INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. ROOF & FLOOR LAYOUTS PROVIDED ON THESE PLANS ARE TO BE USED AS A GUIDE FOR BEARING (ASCE 7-10 (FBC R2017) EXPOSURE C, RISK CATEGORY II) DETERMINATIONS, FEASIBILITY & ARCHITECTURAL AIDE. TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS LAYOUT, SPANS & ALL TRUSS/ HEADER ENGINEERING. ANY DISCREPANCIES FROM THESE LAYOUTS THAT DRAWING REVIEW. WITHOUT THE APPROVAL OF THE ENGINEER. AFFECT THE STRUCTURAL BEARING AS CALLED OUT ON THESE PLANS SHALL BE NOTIFIED TO THE `'SHOP STRUCTURAL ENGINEER OF RECORD PRIOR TO MANUFACTURE OFTRUSSES. THE TRUSS FABRICATOR SHALL SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT MASONRY: PROVIDE ENGINEERED SHOP DRAWINGS OF EACH INDIVIDUAL TRUSS AND A FULLY DIMENSIONED ERECTION OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE PLAN SHOWING COMPONENT LAYOUT. SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A FLORIDA COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC, "SPECIFICATION MASONRY STRUCTURES" (ACI 530/ASCE 51TMS 402, BUILDING CODE REQUIREMENTS FOR LICENSED PROFESSIONAL ENGINEER. ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO MASONRY STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), AS THE HURRICANE STRAPS SPECIFIED ON THE WALL SECTIONS AND PLANS ARE PROVIDED TO FACILITATE THE THE ARCHITECT. DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. PUBLISHED BY THE MASONRY STANDARDS JOINT COMMITTEE. CONSTRUCTION SCHEDULE, AND MAY CHANGE PREDICATED ON THE TRUSS AND GIRDER REACTIONS SHOP DRAWINGS IN THE FORM OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON- PROVIDED BY THE TRUSS ENGINEER. TRACT DOCUMENTS) ARE PROHIBITED WITHOUT THE EXPRESS RITTEN PERMISSION FROM W - ALL BLOCK WALLS SHALL BE TWO -CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK THE TRUSS TO STRUCTURE CONNECTIONS AND LOADS SPECIFIED ON THIS PLAN SHALL SUPERCEDE THOSE THE ENGINEER. MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE fm = 1500 PSI. BLOCK SHALL BE PLACED USING OF THE DELEGATED TRUSS ENGINEER. WIND UPLIFT VALUES HAVE BEEN BASED ON ASCE 7-10 COMPONENT IN ALL INSTANCES, THE CONTRACT DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE AND CLADDING WIND LOAD PRESSURES. THE DELEGATED TRUSS ENGINEER SHALL BE RESPONSIBLE FOR CHECKED, UNLESS OTHERWISE SPECIFIED IN WRITING BY THE ARCHITECT. PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ALL TRUSS TO TRUSS CONNECTIONS. --' _ ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS FOUNDATION/ SITE PREPARATION: — SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" ALL SHEET METAL FRAMING CONNECTORS SHOWN ON THE PLANS SHALL BE "USP STRUCTURAL FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, COURSE AGGREGATE, AND SHALL BE PLACED W/A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION CONNECTORS" BY USP, OR EQUAL UNLESS NOTED OTHERWISE ON PLANS, INSTALL CONNECTIONS FOOTING EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TOA DRY DENSITY TO CONSOLIDATE GROUT. WITH THE SIZE AND NUMBER OF BOLTS/NAILS AS RECOMMENDED BY THE MANUFACTURER IN THE OF AT LEAST 95% OF THE MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELYONTHIS PROJECT. MORTAR SHALL BE LATEST CATALOG. ACCORDANCE WITH ASTM D-1557. TREAT ALL SCAL FOR TERMITE PROTECTION. PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM 0-270. HORIZONTAL AND VERTICAL MORTAR JOINTS -- SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER CELLS TO BE FILLED. TO VERIFY SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS �� __ FAILING TO MEET THE GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND -- _ FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL RETESTED AT THE CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN REINFORCING. CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL BE MADE BY THE GEO-TECH. ENGINEER. LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O. CONCRETE: STRUCTURALSTEEL: CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS. AS FOLLOWS: THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS, 2,600 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 9TH EDITION, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM 3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB. �. _ A36, Fy = 36 ksi FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM A-500, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM-53, GRADE B, TYPE E OR S, Fy = 35 ksi. TUBE AND PIPE CONTRACTOR SHALL SUBMIT PROPOSED MXDESIGNS, WITHHISTORICAL STRENGTH DATA .- COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. FOR EACH SEPARATE MIX PRIOR TO CONCRETE PLACEMENT. CONCRETE SLUMP SHALL - NOT EXCEED 5"41- PRIOR TO THE ADDITION OF PLASTICIZER. ANCHOR BOLTS ATTHE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL OTHER BOLTS SHALL BE ASTM A325-N BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS SHALL CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OFACI 301 ANDASTM C-94OR BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD, MEASURING, MIXING, TRANSPORTING, ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUMTIME ALLOWED FROM WHEN WATER IS ADDED ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J-BOLTS ARE TO BE STEEL. TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OFANY NON COMPLIANCE WITH THE ABOVE. REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): B. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER: 1-1/2" FOR #5 AND SMALLER 2"FOR #6 AND LARGER C. FOR CONCRETE NOT EXPOSED TO WEATHER 3/4' FOR SLABS, WALLS AND JOISTS 1-1/7 FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS FASTENER SCHEDULE WINDOWAND DOOR BUCK FASTENERS FASTENER APPLICATION SIZE TYPE SPACING REMARKS APPLICATION SIZE TYPE SPACING REMARKS 1x2 PT FURRING TO CASE HARDENED COIL 80/C GARAGE DOOR BUCK SEE DETAIL SEE DETAIL SEE DETAIL SEE DETAIL MASONRY/CONC. NAIL 11/V LONG, TO MASONRY/GONG SGD,AL EXT.DOORS CASE HARDENED COIL 91,0/C WINDOW/DOOR/FASTENED GARAGE DOOR BUCK SEE DETAIL SEE DETAIL SEE DETAIL SEE DETAIL It PT, SEE NOTE 7 NAIL 1 1/2" LONG. STAGGERED INTO MASONRY/CONC. TO MASONRY/CONC. WMDOWBUCK CASE HAR DEN ED CO IL 91,o/C WINDOW/DOOR/ FASTENED METAL STRAP TO CONTACT THIS ENGINEER FOR SPACING 1x PT, SEE NOTE NAIL 1112"LONG . STAGGERED INTO MASONRY/GONG. MASONRY/CONE. REQUIREMENTS EXT. SWING DOOR 1/4"° "TAPCON" 12 0/C 112"EMBED, 4" END. NON -BEARING WOOD 1/2"O EXPANSION 24" O/C 4"EMBED .4"END BUCK 2x PT, SEE NOTE 7 NO WASHER FASTNER DIST., 1 12' EDGE DIST. WALL TO CONE SLAB W/ WASHER BOLT DIST., 3" EDGE DIST. 2x PT WINDOW BUCK 0.138-PAF x 2 1/8" 9" O/C 4" END. DIST., 1 1/2"PT TO STEEL COL„ SEE W/ WASHER STAGGERED EDGE DIST. NOTE 7 NOTES 1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED 4. PAF SHALL BE HILT] X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NCA OR THE SPACING DETAILED ABOVE 6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXPECT FOR AN EXTERIOR SWING DOOR VYITH A WOOD DOOR FRAME. 1x MEMBERS ARE NAILED AND 2x MEMBERS ARE SECURED W/ TAPCONS OR PAF TO THE SUBSTRATE. 1441 N. RONALD REAGAN BL LONGWOOD, FL 32750 PH: 407-774-6078 FAX: 407-774-4078 www.abdesigngroup.com AA #: 0003325 ll;,N W h Chi W A E Ety E StTBDIV. 89 LOT: CREEKSIDE LOT #11 PROJECT# 04321.000 011R3 MODEL• 4EGB "GALEN" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHITECT STATE OF FLORIDA jig; 07/12/18 SCALE: 1/4"=11-0" SHEET SNl