HomeMy WebLinkAboutEVALUATION REPORT-MODIFIED BITUMEN ROOF SYSTEMW NN BY St, L((f de om COPY353 IOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 FILE Christian Street, Unit 13 .,,,"TRINITY: Oxford, CT 06478 (203) 262-9245 TION REPORT Ta"co Roofing Evaluation Report T39820.12.11-R3 O Information Way; Suite 225 FL9487-R5 Lit le Rock, AR 72202 Date of Issuance: 12/09/2011 (2 ) 913-1750 Revision 3: 10/02/2017 SC PE: Th � Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of co truction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E' for use of the product under the Florida Building Code. The product described herein has been evaluated for co pliance with the 6`h Edition (2017) Florida Building Code sections noted herein. LeakBarrier® EasySti&m Modified Bitumen Roof Systems LAB'LING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted hel in. CO INLIED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Qu ity Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this'fvaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product cha 'ges or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Eval � ation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TRiNiTYIERD Evaluated" may be displayed in adv I Ising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INS ITION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its di' trlbutors and shall be available for inspection at the job site at the request of the Building Official. This valuation Report consists of pages 1 through 4, plus a 3-page Appendix. Prep'red by: Prepi Robe J.M. Nieminen, P.E. Florid ,I Registration No. 59166, Florida DCAANE1983 a)ttttttrn,.,� —� � The facimilie seal appearing was authorized by Robert Nieminen, P.E. on 30/02/2017. This does not serve as an electronically signed document. CERTIFIOTION OF INDEPENDENCE: 1. E erior Research & Design, LLC. d/b/a Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in a company manufacturing or distributing products it evaluates. 2. Ex erior Research & Design, LLC. d/b/a TrinitylERD is not owned, operated or controlled by any company manufacturing or di ributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for w ch the evaluation reports are being issued. 4. Ro ert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the 5. Thi is a building code evaluation. Neither Trinity lERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any pr ect on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained spGCifically for that purpose. OFING SYSTEMS EVALUATION: 311 4.1' TRINITY �ERD SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: LeakBarrier® EasyStickT" Modified Bitumen Roof Systems, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the 6thEdition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Property 1504.3.1 Wind 1504.7 Impact 1507.10.2 Physical Properties 1507.10.2 Physical Properties 1507.11.2 Physical Properties 1507.11.2 Physical Properties REFERENCES: Entity Examination PRI (TST5878) Physical Properties ERD (TST6049) Wind - FM4470/4474 ERD (TST6049) Wind - FM4470/4474 ERD (TST6049) Wind - FM4470/4474 ERD (TST6049) Physical Properties UL (QUA1743) Quality Assurance Standard Year FM 4474 2011 FM 4470 2012 ASTM D226 2009 ASTM D4601 2012 ASTM D6163 2008 ASTM D6164 2011 Reference Date TOT-041-02-01 05/24/2006 TAR-SC7960.01.16 01/31/2016 TAR-SC5670.03.16 03/21/2016 T6460.06.07-R2 05/26/2017 T6470.08.07-R2 06/02/2017 Service Confirmation Exp. 06/28/2020 PRODUCT DESCRIPTION: This Evaluation Report covers LeakBarrier® EasyStick'"" Modified Bitumen Roof Systems installed in accordance with Tarco Roofing published installation instructions and the Limitations / Conditions of Use herein. The following . A +, m L4 i m the cnhiort c%xtprnc TABLE 1:.ROLL-GOODS FOR LEAKBARRIER® EASYSTICKT"" MODIFIED BITUMEN ROOF SYSTEMS Type Product Specification Reference Type Grade Base Sheets: LeakBarrier® Easyl-ay'" ASTM D226 II N/A LeakBarrier® EasyNailBase"" ASTM D4601 (published) II N/A Smooth Surfaced Membranes: LeakBarrier® EasyBase- ASTM D6163 I S Granule Surfaced Membranes: LeakBarrier® EasyStick'" ASTM D6164 I G lesearch and Design, LLC. Evaluation Report T39820.12.11-R3 opauthorization #9503 6n EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-RS LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017 Page 2 of 4 'x .`i T.NI D LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire classification does not form part of this Evaluation Report; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. Exterior J search and Design, U.C. Evaluation Report T39820.12.11-R3 Certificate fAuthorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-R5 LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3:10/02/2017 Page 3 of 4 9 INSTALLATION: 6.1 EasyStickTM' Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published installation instructions, subject to the Limitations / Conditions of Use noted herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: Underwriters Laboratories —QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com - THE THREE (3) PAGES THAT FOLLOWS FORMS PART OF THIS EVALUATION REPORT - Exterior esearch and Design, LLC. Certificate offtthorization #9503 Evaluation Report T39820.12.11-R3 CH EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-RS LeakBarrieO EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017 Page 4 of 4 APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE Table Deck Application Type Description Page 1A Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 2 1B Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 2 1C-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 2 1C-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 3 1D Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 3 _ The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: i= Wood Deck: OMG #12 or N14 HD with OMG 3 in. Galvalume Steel Plate (non -ribbed) or Tru-Fast DP or HD with Trufast 3" Metal Insulation Plates. Minimum %-inch plywood penetration or minimum 1-inch wood plank embedment. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the CIA requirements of F.A.C. Rule 61G20- 3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105. 7. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, U.C. d/b/a Trinity( ERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick"" Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 1 of 3 W TABLE 1A: WOOD DECKS — NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE C: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Top Insulation Layer Roof Cover MDP No. Deck (Note 1) Base Insulation Layer (psf) Type Fasteners Attach Base Ply Ply Cap W 1. Min. 15/32" plywood (Optional) One or more layers, Min. 3/8-inch SECUROCK Gypsum- Note 2 z 1 per 1 ft EasyBase (Optional) EasyBase EasyStick Plus 52.5 at max. 24" spans any combination, loose laid Fiber Roof Board W-2. Min. 15/32" plywood (Optional) One or more layers, Min. EnergyGuard 2-inch ACFoam II, Polyiso, ENRGY 3, H-Shield, ISO 95+ Note 2 z 1 per 1 ft EasyBase (Optional) EasyBase EasyStick Plus -82.5 at max. 24" spans any combination, loose laid GL or Multi -Max FA3 TABLE 1B: WOOD DECKS— NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Insulation Layer Base Sheet Roof Cover MDP No. Deck (Note 1) Type Attach Type Fasteners Attach Base Ply Cap (psf) W 3 Min. 15/32" plywood Any type, thickness or Loose laid EasyLay Note 2 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. One or two plies, EasyStick Plus -60.0 at max. 24" spans combination in two (2), equally spaced, staggered center rows EasyBase W 4 Min. 15/32" plywood Any type, thickness or Loose laid EasyLay Note 2 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in One or two plies, EasyStick Plus -135.0 at max. 24" spans combination four (4), equally spaced, staggered center rows EasyBase W 5 Min. 15/32" plywood Any type, thickness or Loose laid EasyNailBase Note 2 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in One or two plies, EasyStick Plus -135.0 at max. 24" spans combination I four (4), equally spaced, staggered center rows EasyBase TABLE IC-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER System Base Sheet Roof Cover MDP No. Deck (Note 1) Type Fasteners Attach Base Ply Cap (psf) Min. 19/32" plywood 12 ga. annular ring shank nails and min. 32 ga., 1-5/8" 7-inch o.c. in the 4-inch lap and 7-inch o.c. in three One or two plies, EasyStick Plus -60.0 W 6 at max. 24" spans Easy Lay diameter tin -caps. (Ref: FBC 1517.5) (3), equally spaced, staggered center rows EasyBase W 7 Min. 15/32" plywood EasyLay Simplex MAXX Cap Fastener 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in One or two plies, EasyStick Plus -82.5 at max. 24" spans four (4), equally spaced, staggered center rows EasyBase Min. 15/32" plywood 12 ga. annular ring shank nails and min. 32 ga., 1-5/8" 4-inch o.c. in the 4-inch lap and 4-inch o.c. in four One or two plies, EasyStick Plus -120.0 W 8 at max. 24" spans Easy Lay diameter tin -caps. (Ref: FBC 1517.5) (4), equally spaced, staggered center rows EasyBase W 9' Min. 15/32" plywood EasyNailBase 12 ga. annular ring shank nails and min. 32 ga., 1-5/8" 4-inch o.c. in the 4-inch lap and 4-inch o.c. in five One or two plies, EasyStick Plus 120.0 at max. 24" spans diameter tin -caps. (Ref: FBC 1517.5) (5), equally spaced, staggered center rows EasyBase Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick— Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 2 of 3 TABLE 1C-2: WOOD DECKS— NEW CONSTRUCTION,,REROOF (Tear -Off) or RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (screws & plates), BONDED ROOF -COVER System Base Sheet Roof Cover MDP No. Deck (Note 1) Type Fasteners Attach Base Ply Cap (psf) W 10 Min. 15/32" plywood EasyLay Note 2 10-inch o.c. in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced, One or two plies, EasyStick Plus -60.0 at max. 24" spans staggered center rows EasyBase W-11. Min. 15/32" plywood EasyLay Note 2 8-inch o.c. in the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced, One or two plies, EasyStick Plus -135.0 at max. 24" spans staggered center rows EasyBase W 12 Min. 15/32" plywood TEasyNaflBas, Note 2 6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced, One or two plies, EasyStick Plus -135.0 at max. 24" spans staggered center rows I EasyBase TABLE 11): WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off) SYSTEM TYPE F: BONDED ROOF COVER System Deck (Note 1) Roof Cover MDP No. Type Joint Treatment Base Ply Ply Cap (psf) _ - W 13:• '. Min 15/32" plywood— None ,�`-(Optional).EasyBase,_ _ _ _ -= --(Optional)-EasyBase r` —EasyStick:P-lusr — ---75.0 tmax._24�spans w W 14. Min. 15/32" plywood Plywood joints are covered with 4-inch wide strips of EasyBase, rolled into (Optional) EasyBase (Optional) EasyBase EasyStick Plus 120.0 at max. 24" spans place to create continuous bond. Exterior Research and Design, LLC. d/b/a Trinity IERD Evaluation Report T39820.12.11-R3 for FL9487-RS Certificate ojAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017 Prepared by: Robert Nieminen, PE-59166 LeakBarrier" EasyStick" Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3 of 3