Loading...
HomeMy WebLinkAboutGENERATOR CONCRETE PADa� N 0 1tiN'�N T,��IpT GENERATOR W I ry AMERICAST GENERATOR CONCRETE PAD PAD THICKNESS PpD LENGPN ISOMETRIC VIEW PAD DIMENSIONS: GENERATOR TABLE:. CONCRETE PAD GENERATOR - I = I GENERATOR UNIT BY o SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR M I MINIMUM WEIGHT REQUIRED) }-- 54" LENGTH PLAN VIEW CONCRETE PAD ROAD MESH MASTERFIBER 3" MIN MAC100 -f4e MIN GROUNDS ,, „ , „ , „,,, , 50" 54" SCANNED t) BY (ON -GRADE APPLICATIONS ONLY) AMERICAST =hflmcE,m ina wm •NADIR IN ANMMC1A:' FEDTAXp394252M2 LICENSEL+59R206f0163 sm P-Wow A- Pm Maros. FL 740p Tal: 772-971-19M I= 7724644=9 Email; aal .ancrlcnN�.crm er eha.lexdfQtOlr�whe HVHZ OR NON-HVHZ COUNTY RISK EXPOSURE EXP RISK EXPOSURE EXP RISK I EXPOSURE EXP C I D 11 C D III, IV C D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19'Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf 186 MPH 146.80 Psf 156.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 SO KW 25.00 " 48.00 " 29.00 " 387 Ibs . 41.43 Psf EXP C 175 MPH & D 156 MPH Generac 005872 & 005884 14 KW 25.00 " 48.00 " 29.00 " 439 Ibs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 6459, 6461, 6462 16 KW 25.00 " 48.00 " 29.00 " 513 Ibs 47.44 Psf Generac 006721 16 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac 005873 & 005885 17 KW 25.00 " 48.00 " 29.00 " 455 Ibs 47.44 Psf Generac 005874 & 005886 17 KW 25.00 " 48.00 " 29.00 " 421 Ibs 47.44 Psf Generac 005875 & 005887 20 KW 25.00 " 48.00" 29.00 " 451 Ibs 47.44 Psf Generac 006729 & 006730 20 KW 25.00 " 48.00 " 29.00 " 516 Ibs 47.44 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00 " 29.00 " 526 Ibs 47.44 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 500 Ibs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 39.09 Psf EXP C 170 MPH & D 156 MPH GE 04038215KW 15 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf EXP C 180 MPH & D 156 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf GE 40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 43.83 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 41.43 Psf EXP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 5621bs 43.83 Psf EXP C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75" 49.00 " 31.60" 570 Ibs 44.00 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " 406 lb! 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & 007039 20 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac 007042 & 7043 22 KW 25.00 " 48.00" 29.00 " 466 Ibs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS T I -Q (SEE.GENERATOR GENERATOR S) 1kA 6 IC�`AL3fANIZEGENE- WASHER& RUBBER I (SEE CONCRETE PAD VIBRATION PAD SCHEDULE FOR DIMENSIONS & WEIGHT REQUIRED) CONCRETE PAD - � 6,000 PSI 4 n I LIGHTWEIGHT— n CONCRETE MIX ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI - OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE; 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS %" SIMPSON TITEN HD, - SEE ANCHOR SCHEDULE 2"x3"x3/a" GALV. STEEL WASHER RUBBER VIBRATION PAD CONCRETE PAD 6,000 PSI LIGHTWEIGHT X CONCRETE MIX MASTERFIBER MAC 100 NOTES: FOAM CORE 2" WIDTH 54" LENGTH 1 Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". ISTANCL3TROM-UNFT-EDGE Tn rl ry SIDE VIEW FRONT VIEW 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS -�-ze--t FRANK L. B NARDO, P.E. PE# 004654 I �il 03u `1,' 0.1.8 n I RECEIVED 6OEO,D, '3 P.E. aPPELR`5 BMW 2328 N M. BAITISTO, F- VALID FOR I FIERMI NOTICE: IF THIS SHEET DOES AUG)j n U 23 NOT CONTAIN AN ORIGINAL SIGNATURE & ENGINEER SEAL: IF THERE IS A DIGITAL - I i SIGNATURE ON SHEET 1, THIS ST. Lucie County, Permitting SHEET IS PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED I- _ __ _ _ _ AND SEALED. IF THERE IS NO WIND DESIGN REQUIREMENTS_ DIGITAL SIGNATURE ON SHEETI OR THIS SHEET DOES NOT CONTAIN AN ENGINEER'S (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017 )) ORIGINAL SIGNATURE & SEAL, THIS SHEET IS A COPY DRAFT. AT -GRADE SIGN METHOD rrnn p fV ULTIMATE DESIGN WIND SPEED Vult = 186 mph U NOMINAL DESIGN WIND SPEED Vasd = 144 mph Z �qT o RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A ® W Cn , u i EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= a: w ►.- M ui OwU CO U LL cc w ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT W 1L N X N LV FACTOR = 0.85 PRESSURE AT HEIGHT H qh = 77.56 O 2 Ib/ft2 ¢ w UJ U "� X ~ > Q " w FORCE COEFFICIENT Cf = 1.44 c� a � Q LLI L.0 LD WIND PRESSURE O Orm'??Z H P= qh G Cf = 56.80 Ib/ft2 (ASD) 11, N O A W O W w W 0'-1 W v@z GENERAL NOTES 3 LL vtu" U) U O W 1U 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE . to in SIXTH EDITION (2017). 14 - n 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. N O CD SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH d THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE O 0 DESIGN PRESSURE'ASD" CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN.U. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS / /� LU O O STATED HEREIN. 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL V 4 Q. U_ Ln Q GI Y H= r4 F- CLEARANCE. A MINIMUM DISTANCE FROM UNIT O W M TO PAD EDGE IS SPECIFIED. S. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF / � V �.! .,� of LLJ W U) 6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL [ -1 W f\ 11.I VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR rt-4 a CA N En O TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 7. RESISTANCE Q N LU O_ � P1 (, O TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. n S M O M U_ :5 J (D8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY- `. Y OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) Lr) LLI SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE .ni CO EXPRESS RESPONSIBILITY OF THE CONTRACTOR. U) W 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS U. < SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES O INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL LL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT B WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL C1 RESPONSIBILITY OF THE INSTALLING CONTRACTOR, CONTRACTOR SHALL 0 z o m w LL m m ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE rc x PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY V LL LL , z w 6 Z 3 O O O WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING - � I I CONTRACTOR. p S g g , z 11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY .q� � �.� z ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE N a $ ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY ��++ w p OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL RES0913D_IN_AT_ ED_ B_Y THE PERMI.TRNG CONTRACTOR. `12 m - __ 12. T - ERI - E�BT=PERTAIN TO ANv-c9Ft�rt7t= C'Q _ o PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS o OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ARE SHOWN TO z N ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY COPrtiIGHT ENGINEERING EXPRESS SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. J-��� J1 --ENGEXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPOWDISCOVERY-OF-ANYYNACCURATE 1INEERING . _ INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS SCALE: NTS UNLESS NOTED AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR of ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS \ \ GENERATOR _ \ I ' II PAD �\ THICKNESS �PPOI.EN'� PAD DIMENSIONS: CONCRETE GENERATOR Fa = GENERATOR UNIT BY o SEPARATE SUBMITTAL 3 (SEE SCHEDULE FOR M MINIMUM WEIGHT REQUIRED) 54" LENGTH PLAN VIEW CONCRETE ROAD MESH- MAC100 GROUND - 50" 54" 32" WIDTH 3" MIN 4„ ISOMETRIC VIEW 4" MIN F AMERICAST GENERATOR- CONCRETE GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMA ST 'B ADR INI AMEMOA- FEDTAXOZD4252362 LICENSa7599306i0113 9W;Wma0 Alv. Fen Dbm, FL 7067 T.I. 772-9714M F- 777J64-0SOD EmdL- HVHZ OR NON-HVHZ COUNTY RISK EXPOSURE EXP RISK EXPOSURE EXP RISK EXPOSURE EXP I C D II C I D III, IV C D P. BEACH 150 MPH 30.44 Psf 36.94 Psf 110 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf1 50.28 Psf, 186 MPH 46.80 Psf 56.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00 " 48.00 " 29.00 " 387 Ibs 41.43 Psf EXP C 175 MPH & D 156 MPH Generac 005872 & 005894 14 KW 25.00 " 48.00 " 29.00 " 439 Ibs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 6459, 6461, 6462 16 KW 25.00 " 48.00 " 29.00 " 513 Ibs 47.44 Psf Generac 006721 16 KW 25.00 " 48.00 " 29.00 " 448 Ibs 47.44 Psf Generac 005873 & 005885 17 KW 25.00 " 48.00 " 29.00 " 455 Ibs 47.44 Psf Generac 005874 & 005886 17 KW 25.00 " 48.00 " 29.00 " 421 Ibs 47.44 Psf Generac 005875 & 005887 20 KW 25.60 " 48.00 " 29.00 " 451 Ibs 47.44 Psf Generac 006729 & 006730 20 KW 25.00" 48.00 " 29.00 " 516 Ibs 47.44 Psf Generac 006551 & 006552 22 KW 25.00 " 48.00" 29:00 " 526 Ibs 47.44 Psf Kohler 14RES & 20RES 14-20 KW 26.00 " 48.00 " 29.00 " 500 Ibs 47.44 Psf GE 40323GE & 40324GE 13 KW 35.00 " 39.40 " 39.00 " 540 Ibs 39.09 Psf EXP C 170 MPH & D 156 MPH GE 04038215KW 15 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf EXP C 180 MPH & D 156 MPH GE 04037817KW 17 KW 33.00 " 48.00 " 30.50 " 484 Ibs 43.83 Psf GE 40330GE & 40331GE 20 KW 33.00 " 48.00 " 30.50 " 600 Ibs 43.83 Psf Briggs & Stratton 040243-0 10 KW 31.00 " 32.00 " 34.00 " 430 Ibs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00 " 31.60 " 507 Ibs 41.43 Psf EXP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 15 KW 33.75 " 49.00 " 31.60 " 562 Ibs 43.83 Psf EXP C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00 " 31.60 " 568 Ibs 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75 " 49.00 " 31.60 " 570 Ibs 44.00 Psf Generac 7035, 7036, 7037 16 KW 25.00 " 48.00 " 29.00 " M lbs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & 007039 20 KW 25.00 " 48.00- 29.00 " 448 Ibs 47.44 Psf Generac 007042 & 7043 22 KW 25.00 " 4___'. 29.00 " 466 Ibs 47.44 Psf GENERATOR MOUNTING CONFIGURATION: (SEE CONCRETE PAD SCHEDULE FOR DIMENSIONS & WEIGHT REQUIRED) 54" LENGTH GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS TO GENERATOR (SEE GENERATOR SPECS) THICK GALVANIZED PAD i kEGEIVED AUG0;22018 I ANCHOR TO PAD SCHEDULE SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 TITEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED O CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS 3/D" SIMPSON TITEN HD, SEE ANCHOR SCHEDULE 2"x3"x3/8' GALV. STEEL - WASHER RUBBER VIBRATION PAD - 6,000 PSI LIGHTWEIGHT CONCRETE PAD X CONCRETE MIX E 6,000 PSI ` LIGHTWEIGHT MASTERFIBER MAC 100 J CONCRETE MIX & ROAD MESH C NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN -a L. BERNARDO, P.E. 037JV,20 18 oa ED, :r. v.E, APKN;5,,OHDY! DON M: IBI, TTISTO; P. E. ' i p rt SIGNATURE ON SHEET 3, THIS } 1 1,}�,._.��y WOO. ���101� SHEET IS PART OF A DIGITALLY _ SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNEI L - - - - - - - - - - - - - - - - - AND SEALED. IF THERE IS NO WIND DESIGN REQUIREMENTS_ DIGITAL SIGNATURESHEET H DOES EST NOT (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION CONTAIN AN ENGINEER'S (2017 )) ORIGINAL SIGNATURE & SEAL, THIS SHEET IS A COPY DRAFT. AT -GRADE SIGN METHOD rrnn 0 N ULTIMATE DESIGN WIND SPEED Vult = 186 mph U NOMINAL DESIGN WIND SPEED Vasd = 144 mph Z .-) V RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A ® IL fn 'n V f EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= a: )ii f- M 4 In 0 0.85 W O5JA-vim LL ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND GUST EFFECT FACTOR LL U) �^ O. V) C, W W Lu = 0.85 PRESSURE AT HEIGHT H qh = 77.56 O 2 �'�' x Ib/ft2 FORCE _Z w W U '-' z 0- In COEFFICIENT Cf = 1.44 a <' Q W w L7 LLO WIND PRESSURE U g Or m Q�Z P= qh G Cf = 56.80 Ib/ft2 (ASD) N 0� u W W O W w 0 N GENERAL NOTES rnOz W a=W 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE 0 w w 10 SIXTH EDITION (2017). n 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH 0. THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE O 0 DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY Lq ASSEMBLY AS SHOWN. oe 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS STATED HEREIN. ; � U w 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL Q LL Ln Q O Ol U! Y ,Z., = ry N It CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. 5. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF +•-� ( , V L M F- - 6. THE AREA UNDER CONCERETE SLAB ON GROUND N w uj SHALL HAVE ALL W 0 r, VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR p'-', U) 0 TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. 7. RESISTANCE Q N W O- H M z U O TO SLIDING OF THE PAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. �� MO � B. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED &INSTALLED BY M Y O OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) N Lu SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE .^-1 m EXPRESS RESPONSIBILITY OF THE CONTRACTOR. W N Q -- 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS < SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES O INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL -1 u FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT W WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. 10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL G RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR o S o u'Sg a . SHALL • ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS G RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE S U 9 111 1 o �g R ' PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY iU - II. LL z �+ O 0 3 O O 3 3 WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS WATER -TIGHTNESS SHALL.BE THE FULL RESPONSIBILITY OF THE INSTALLING CONTRACTOR. o €o q Li pZ 11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE $ ? o ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE INTEGRITY OF ALL SUPPORTING SURFACES a �" TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR. 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN SPECIFIC w o o z TO ANY - - - y �- z o kWEcT-.iFE=4NFORMATFON=C-0NTmNEQHEREIW4S:BASED-0 - - ---- CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS �. - SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. M 2 Lu � DIMENSIONS ARE SHOWN TO z 0 N ' ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY COPYRIGHT ENGINEERING EXPRESS SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO 1 %-3961.1 REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INF6RMATION-PRIORT6-MODIFICATION-OF-EXISTING-FIELD-CONDIRONS- -SCAIFNTSUNCESSTJOTEO AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR OP ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS ^ OR AFFIRMATIONS ARE INTENDED. 'C(