BLOWER DOOR TEST FORM
House Infiltration Test Certification
Prescriptive and Performance Method
AJ G q/
Date• `I ( Permit #: �y D d
Cont LO N PDy 1 G
Job dress: �-03�5 �Je_++I-Ae-5 6 [V J
Cons (,ruction: ()0 New Construction — Complete ( ) Existing —After Addjtion
Hou a Infiltrati n Test Results SLC Climate Zone 2 L/-s CF (50) _ 5CI Test Date: L I
Voldine = _La 61 9
AC �(50) = CFM (50) x 60 / Volume = Mechanical Ventilation required less than 3 ACH
Pas f,ing results must be & ACH (50) or less (, Pass ( ) Fail
FBC, nergy
The w ing or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hou I in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blo er door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Sect l )n 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
app ved third party. A written report of the results of the test shall be signed by the party conducting the test and
pro ;tided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
the iMt envelope.
Residential
the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
-e of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
ailing unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
TeAlniz Com an 7r
Col pany Name: _y FA Address: N wnm m � c1Y- (fV
I h ' reby certify that the above House Infiltrati n results demonstrate compliance with FBC Energy Conservation
re uirements i ordance ection R40 . .1.2 Climate Zone 2.
5i1 ature: _
Name ��✓� CcCVI Ck ��
#: 6n 2 s® (Ul