Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCECOt1NTY F L O Planning & Development Services Department SCANNED, Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462 ' IW e crom Certification for Design Load Compliance Project Name: Homan Residence Project Address: Lot 2035 @ Nettles Island, St. Lucie County, FL Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and ,certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) . DESIGN CODE: Florida FBC Code 2010 Edition with 2017 Supplements using ASCE 7-10 Structure Designed as (check one): X Enclosed Partially Enclosed Open Risk Category: _I X II III IV Exposure Category: B C X D Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 3 ft ,. Mean Roof Height 24 ft Roof Pitch: 4 :12 Parapet: NSA ft Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: 42.9 Zone 2: 74•7 Zone 3: 74.7 Zone 4: 50.9 Zone 5: 62.8 Garage: 52.3 7' Design Loads: Floor: 65 PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 60 PSF Dock: NSA PSF Deck: NSA PSF Stairs: 40 PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable` Explain Why Not: 9.II Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10�I Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes I cis 'tify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to coly with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie Coty. I also certify that structural elements depicted on these plans provide adequate resistance to the design Fospecified: re, Dath, and Seal 07/25/2014 Shawn Stambaugh, PE PE#: 61850 Print Name Cert # & Co. Cert Auth. Quantum Engineering Associates, Inc. 300 Ave. of Champions, Ste 260, Palm Beach Gardens, FL 33418 Company Name &Address FILE COPY