Certification for Design Load Compliance
Project Name: Homan Residence
Project Address: Lot 2035 @ Nettles Island, St. Lucie County, FL
Permit #: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
,certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
. DESIGN CODE: Florida FBC Code 2010 Edition with 2017 Supplements using ASCE 7-10
Structure Designed as (check one): X Enclosed Partially Enclosed Open
Risk Category: _I X II III IV Exposure Category: B C X D
Design Wind Velocity 165 mph ASD X LRFD End Zone Width: 3 ft
,. Mean Roof Height 24 ft Roof Pitch: 4 :12 Parapet: NSA ft
Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 42.9 Zone 2: 74•7 Zone 3: 74.7 Zone 4: 50.9 Zone 5: 62.8 Garage: 52.3
7' Design Loads: Floor: 65 PSF Roof/Dead: 25 PSF Roof/Live: 30 Balcony: 60 PSF
Dock: NSA PSF Deck: NSA PSF Stairs: 40 PSF Fence: NSA PSF Railings: NSA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable` Explain Why Not:
9.II Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10�I Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? X Yes
I cis
'tify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
coly with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
Coty. I also certify that structural elements depicted on these plans provide adequate resistance to the design
Fospecified:
re, Dath, and Seal
07/25/2014
Shawn Stambaugh, PE PE#: 61850
Print Name
Cert # & Co. Cert Auth.
Quantum Engineering Associates, Inc.
300 Ave. of Champions, Ste 260, Palm Beach Gardens, FL 33418
Company Name &Address