HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil Nuclear Gauge
Report Date: 10/4/2018
Test Method: ASTM D 6938
Port St. Lucie
FBPE CA of 4930
607 NW commodity Cove
Port St Lucie, FL 34986
Phone: 772-924-3575 1 Fax: 772-924-3580
Client: Project:
Doyle Masonry, Inc. 17-6476.00
P.O. Box 12339 Doyle Masonry, Inc. 2017-2018 Master
Fort Pierce, FL.34979-2339 Agreement
Various Locations
FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification(pcf)
N134
Maximum
Dry Density
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
35
10/2/18
8188 D1557
N/A
100.3
12.8
97.8
12
98
95 / 105
Pass
36
10/2/18
8188 D1557
N/A
100.3
11.9
97.6
12
97
95/ 105
Pass
37
10/2/18
1 8188 D1557
N/A
1 13.4
1 100.3
12.3
96.5
1 12
1 96
1 95 / 105 1
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
35
Pad: 2035 Nettle Island Jenson Beach, NE Comer
0-1'
Humboldt / 5001 SD / 9086 /
Keller, Marcus
36
Pad: 2035 Nettle Island Jenson Beach, Center
0-1'
Humboldt 15001 SD / 9086 /
Keller, Marcus
37
Pad: 2035 Nettle Island Jenson Beach, SW Corner
0-1'
Humboldt / 5001 SD / 9086 /
Keller, Marcus
Remarks I Comments
Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testinq aqencv.
OCT 0 4 2018
ST. Luc(e C<at�ni�Y�_® 9
o 6321
18/04/�
11 KeptrP. E. 41
SiOOT
St, uN�� ���
1lllllt
1e Renortc-shaI1zW=be repredaee �xcept'rrr frt�t ; - isut-the wn en approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
U-*3