BLOWER DOOR TEST FORM St. Lucie County
House Infiltration Test Certification
Prescriptive and. Performance Method
Date: S G (,A Permit #: g v — 0( Z k
Contrac or: _ �r 13 A e Aff
� i I e K� (, �_��i� lob Ad i ess: ���, ��(- S�- . ,
Constrw' ion: New Construction — Complete ( ) Existing —After Addition
House I 'filtration Test Results SLC Climate Zone 2
CFM (5 = 1 2 6 q Test Date:
Volume it 7T LT 0 2'T
ACH (5 = CFM (50) x 60 / Volume = Mechanical Ventilation required less than 3 ACH
Passing �esults must be & ACH (50) or less .Pass ( ) Fail
FBC, Ene gy
The buil Ong or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in imate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower d' or at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 3.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approve third party. A written report of the results of the test shall be signed by the party conducting the test and
provide to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal ', nvelope.
FBC, Re �den4ial
U!lhere t e air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressur of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testin om an
Compa Name: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949
i
I hereb certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
require ents in accordance h Secti n R402.4.1.2 Climate Zone 2.
Signatu ;e:
i
Printed ame: Martin Klein
Licerlsei Certification #: 5061633