HomeMy WebLinkAboutREVISION 1-9-19i
OFFICE U ONLY:
SCANNO
DATE FILE I: gad PERMIT #
REVISION II EE: :Lijd �- Cog*-' RECEIPT #
PLANNING & DEVELOPMENT SERVICE
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553
APPLICATION FOR BUILDING PERMIT REVISI
PROJECT INFORMATION
.TION/SITE
D TAILED DESCRIPTION OF PROJECT
VISIONS:
C , NTRACTOR INFORMATION:
SIATE of FL REG./CERT. #: CBC051145
131. SINESS NAME: GHO Homes
QV, ALIFIERS NAME: William Handler
AIRDRESS: 590 NW Mercantile Place
CII Y: Port Si Lucie STATE: - FL
P ONE (DAYTIME): 772-873-1711
01 R/BUILDER INFORMATION:
N E: GHO Homes
A DRESS: 590 NW Mercantile Place
: Port St Lucie STATE: FL
ATE (DAYTIME: 772-873-1711 -
EIITECT/ENGINEER INFORMATION:
LESS: 11634 SW Rowena St
• Port St Lucie
dE (DAYTIME): 561-629-6975
SD CC: 9123109
Rel ised 06130/17
i
I
=RECEIVED
ST. LUCIE CO CERT. #:
ZIP: 34986
FAX: 561-689-0909
ZIP: 34986
FAX: 561-689-0909 -
S
FOR
FLi
F
}
Projei
Streel
City, Sote, Zip:
Owne
Desig
1. New
2. Sing
3. Num
,4. Num
k�l.
5. Is thl
x 6. Con(
Com
7. Winc
S
b. U
S
c.. U
s
d. U
S
L Area
Area
8. Floo
a. SIB
b. N/
c. N/
1 r.IAQQ
'i
I here
this c,
Code.
PREF
DATE
s I here
with tt
OWN
DATE
: . r:nn
- wr
enve
1 /8)
f,
RECEIVED
JAN 0 9 2019
R405-2017 ST. Lucie.County, Permitting
RIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
irida Department of Business and Professional Regulation - Residential Performance Method
Builder Name:
Permit Office: PermitJ 6 b 8 D, 3 Q
: tJumber. /
Jurisdiction:
County: St. Lucie (Florida Climate Zone 2 )
MW-278
3360 BENT PINE DR
FORT PIERCE, FL, 34951
FL, Fort Pierce
!onstruction or existing
family or multiple family
er of units, if multiple family
er of Bedrooms
a worst case?
tioned floor area above grade (ft2)
tioned floor area below grade (ft=)
lws(443.6 sgft.) Description
actor: Dbl, U=0.62
GC: SHGC=0.26
'actor: N/A
GC:
'actor: N/A
GC:
'actor: N/A'
GC:
Veighted Average Overhang Depth
Veighted Average SHGC:
Types (2284.0 sgft.)
-On-Grade Edge Insulation
Area: 0..194
New (From Plans)
Single-family
1
3
No
2284
0
Area
443.61 ft2
ft2
ft2
ft2
0.000 ft.
9. Wall Types (2380.9 sgft.)
Insulation
Area
a. Concrete Block - Ext Insul, Exterior
R=4.0
2071.10 ft2
b. Frame - Wood, Adjacent
R=11.0
309.78 ft2
c. N/A
R=
ft2
d. N/A
R=
ft2
10. Ceiling Types (2284.0 sgft.)
Insulation
Area
a..Under Attic (Vented)
R=30.0
2284.00 ft2
b. N/A
R=
ft2
c. N/A
R=
ft2.
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Main
6 724
12. Cooling systems
a. Central Unit
13. Heating systems
a. Electric Strip Heat
0.260 14. Hot water systems
Insulation Area a. Electric
R=0.0 2284.00 ft2 b. Conservation features
R= ft2 None
R= ft2 15. Credits
Total Proposed Modified Loads: 72.89
Total Baseline Loads: 76.09
certify that the plans and specifications covered, by
elation are in compliance with the Florida Energy
RED BY:u
01 /08/ 19
certify t fit thig'builbl ng,. as design e is in compliance
Florida //Energy Cod.
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code,
Before construction is completed
this building will be inspected for
compliance with Section 551908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
kBlu/hr Efficiency
46.0 SEER:16.00
kBtu/hr Efficiency
25.0 COP:1.00
Cap: 50 gallons
EF: 0.940
Pstat
I
PASS I-
Alance requires certificationby the air handler unit manufacturer that the air handler enclosure qualifies as I
led factory -sealed inr accordance with R403.3.2.1.
,fiance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an;
?e leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
j
19 2:14 PM EnergyGauge®USA Section R405.4.1 Compliant Soft RarEVISJ,ON
FILE COPY,
1
i
FORM Ani;-9n, 7
1KrO1 IT QI 1KARAA w w11or0-14i..A� ------
-
PROJECT
Title:
Bulldin
Owner
# of U
Builde
Permit;
Jurisdl'
Family
New/E.
om
Comm
Type:
ame:
Is:
Name:
(lice:
Uon:
ype:
sting:
' nt:
i�
MW-278
User
1
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2284
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 3300 BENT PINE DR
County: St. Lucie
City, State, Zip: FORT PIERCE,
FL, 34951
CLIMATE
/
V
II Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Nur4lber
Name
Area Volume
1
Blockl
2284 21241.2
SPACES
Nu
ber
Name
Area Volume Kitchen Occupants
Bedrooms
Iniil ID Finished Cooled Heated
1
Main
2284 21241.2 Yes 4
3
1 Yes Yes Yes
FLOORS
1 #
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
I Slab -On -Grade Edge Insulatio Main 209.9 ft 01
i
2284 ft'
—
1 0 0
j
ROOF
/
V
�I #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emift Deck Pitch
Tested Tested Insul. (deg)
1
Hip
Flat ille/slate 2554 ft' 0 ft1 Medium
0.46
N 0.9 No 0 26.6
ATTIC
V
#
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2284 111
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
2284 ft' 0.1 Wood
2:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
l �
'
i
FORM RI
052017
INPUT SUMMARY CHECKLIST REPORT
WALLS
ff2j
Adjacent
--To
Space `
WaIL4pA p
Cavity Width Height Sheathing Framing Solar Below
R alua-Ft-In-Ft- In Area-_R-1/alue_Eraction_Abso"rade°/
Exterior
Concrete Block - Ext Insul Main
4 32 0 11 4
362.7 ft'
0
0
0.3
0
Exterior
Concrete Block - Ext Insul Main
4 55 0 9 4
513.3 ft'
•0
0
0.3
0
Exterior
Concrete Block - Ext Insul Main
4 58 2 9 4
542.9 ft=
0
0
0.3
0
_ 4
SW
Exterior
Concrete Block - Ext Insul Main
4 8 7 11 4
97.3 ft'
0
0
0.3
0
5
W
Exterior
Concrete Block - Ext Insul Main
4 55 11 9 4
521.9 ft'
0
0
0.3
0
6
NW
Exterior
Concrete Block - Ext Insul Main
4 2 11 11 4
33.1 ft'
0
0
0.3
0
_ 7 I
-
Garage
Frame -Wood Main
11 27 4 11 4
309.8 ft'
0
0.25
0.3
0
I
DOORS
#
Omt
Door Type Space
Stones U Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Main
None .39
3
8
24 ft'
WINDOWS
Orientation shown is the entered Proposed orientation.
/
I
Wall
Overhang
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Depth
Separatii
i
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
48.0 ft'
0 ft 0 in
0 ft 0 In
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
8.0 ft'
0 ft 0 In
0 ft 0 In
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
8.0 ft'
0 It 0 In
0 ft 0 in
!4I
n
1
Metal
Double (Clear)
Yes
0.62
0.26
N
15.0 ft'
0 ft 0 In
0 ft 0 in
5
e
2
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 W
0 ft 0 In
0 ft 0 in
e
2
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 ft'
0 ft 0 In
0 ft 0 in
e
2
Metal
Double (Clear)
Yes
0.62
0.26
N
9.0 W
0 ft 0 In
0 ft 0 in
s
3
Metal
Double (Clear)
Yes
0.62
0.26
N
43.3 W
0 ft 0 In
0 ft 0 In
s
3
Metal
Double (Clear)
Yes
0.62
0.26
N
112.4 ft'
0 ft 0 In
0 ft 0 In
0
s
3
Metal
Double (Clear)
Yes
0.62
0.26
N
31.6 ft'
0 ft 0 In
0 ft 0 In
1
s
3
Metal
Double (Clear)
Yes
0.62
0.26
N
6.5 ft'
0 ft 0 In
0 ft 0 In
sw
4
Metal
Double (Clear)
Yes
0.62
0.26
N
20.0 ft=
0 ft 0 In
0 ft 0 In
I
sw
4
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 ft'
0 ft 0 in
0 ft 0 In
w
5
Metal
Double (Clear)
Yes
0.62
0.26
N
21.3 W
0 ft 0 in
0 ft 0 in
w
5
Metal
Double (Clear)
Yes
0.62
0.26
N
6.5 ft=
0 ft 0 In
0 ft 0 In
I
w
5
Metal
Double (Clear)
Yes
0.62
0.26
N
12.0 ft'
0 ft 0 in
0 ft 0 In
rl
NW
6
Metal
Double (Clear)
Yes
0.62
0.26
N
16.0 f12
0 ft 0 In
0 ft0 in
GARAGE
#
RooArea
Calling Area
Exposed Wall Perimeter
Avg. Wall Height
Exp
1
686 ft'
686 ft°
64 ft
9.3 ft
Int Shade Screening
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
None
Wall Insulation
1
1/8/2019I:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
. i
'FORM A, ns_2m.7
1K101 1r 011r1A11AAov ocso%or
INFILTRATION
#
mpe Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Whc
ehouse Proposed ACH(50)
.000295
1770.1 97.18 182.75 .224 5
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COPA 25 kBtulhr 1
sys#1
COOLING SYSTEM
_
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER:16 46 k8tulhr 1380 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.94 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cori # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft:
DUCTS
/
— Supply —
# Location R Value Area
-- Return -- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1 Attic 6 724 ft'
Attic
601 ft' Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Progran
Cooling
WritinggHJan
VenUn
able Thermostat: Y
'I Jan Feb Mar
HFeb XMar
Jan Feb XMar
Ceiling Fans:
Apr Ma M Jun ui Au Se Oct Nov
E pr f MayJun 111 ul AuMSep W Oct Nov
[x] A r [ Ma Jun Jul M Aug Se Oct Nov
Dec
Dec
Dec
R
1/8/2011,I2:14 PM EnergyGaugeS USA Section R405.4.1 Compliant Software Page 4 of 5
{- I
l
FORM F 05-2017
IINDI IT CI IMIWADV f%UCf%V1 1eT n=snnt
Thermo l at Schedule: HERS 2006 Reference
Hours
Schedul,Type
-. 1
2
3
4
5
6
7
8
9
10
11
12
Cooling D)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
80
10
80
80
78
78
78
78
78
78
Cooling EH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating D)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
168
68
68
68
68
68
68
66
68
66
Heating EH)
AM
PM
66
68
66
68
66
66
66
68
66
68
68
68
68
68
68
68
68
88
68
68
68
66
68
66
MASS
�ss Type
Area
Thickness
Furniture Fraction
Space
fault 8 Ibs/s .ft.
0 fl=
0 ft
0.3
Main
Name:
Rating Compant:
r
Signature:
Date:
1 1/8/2019 � 14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
I
4
I
ZU1
i
EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED
ENERGY PERFORMANCE INDEX* = 96
The lower the Energy Performance Index, the more efficient the home.
1
New home or, addition
1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R
6.0
2
Single-family or multiple -family
2. Single-family b) Return ducts R
6.0
c) AHU location Attic/Attic
3
No, of units (if multiple=family)
3. 1
4
Number of bedrooms
4. 3 13. Cooling system: Capacity
46.0
5.1
Is this a worst case? (yes/no)
a) Split system SEER
5. No b) Single package SEER
16.0
Ground/water source SEERICOP"area
6.
Conditioned floorc)
(sq. ft.)
i
6. 2284 d) Room unit/PTAC EER
e) Other
7.
Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260 14. Heating system: Capacity
25.0
c) Area
7c. 443.6 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8.
kylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
8a. NA d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA e) Gas furnace, LPG AFUE
9.'Floor
type, insulation level:
f) Other
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b. 15. Water heating system
c) Concrete, raised (R-value)
9c. a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
1
' Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1. e) Dedicated heat pump with tank EF
12. Masonry (Insulation R-value)
10A2. 4.0 f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11
Ceiling type and insulation level .
a) Ceiling fans
a) Under attic
11 a. 30.0 b) Cross ventilation
No
b) Single assembly
11 b. c) Whole house fan
No
c) Knee walls/skylight walls
11 c, d) Multizone cooling credit
d) Radiant barrier installed
11 d. No e) Multizone heating credit
i
f) Programmable thermostat
Yes
*L
ei required by Section R303.1.3 of the Florida
Building Code, Energy Conservation, if not DEFAULT.
I c
rtify that this home has complied with the Florida
-Building Code, Energy Conservation, through the above energy
sal•ling
features which will be installed (or exce9d6d) in this home before final inspection. Otherwise, a new EPL
dis
• lay card will be co m leted based on in oiled
I'
code compliant features.
Bu
der Signature:
Date:
Ad
I
ress of New Home: 3300 BENT PINE DR
City/FL Zip: FORT PIERCE, FL 34951
1/8/2019
1 14:22 PM EnergyGauge® USA 6.0.02 - F1aRes2017 PBC 6th Edition (2017) Compliant Software
Page 1 of 1