HomeMy WebLinkAboutNOA ROOF TILE---------------
RECEIVED
GGANNE
By AUG 0 3 2098
-L-Uoli20oanti 15T. LWCle County, Permitr•,-
MIENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
AND CODE ADMINISTRATION DIVISION
[CE OF ACCEPTANCE (NOA)
ma Aloof Tile, LL'C
NE 91" hobee, °e FILE COPY
:chobee, FL 34972
liIA14II DAIDE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315.2590 F (786) 315 2599
ww .miamidade eo-0eeenomv
OPE:
i NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
umentation submitted bas been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
i in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
T is NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this
pr Nutt or material tested for quality assurance purposes. if this product or material fails to perform in the accepted
in er, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
su pend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if ft is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
reuirements of the applicable building code.
T is product is approved as described herein, and has been designed to comply with the Florida Building Cods
in;luding the Idigh Velocity Hurricane Zone of the Florida Building Code.
JESCRIPTION: Plantation Roof Tile
FLING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
st ternent: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
NEWAIL of this NOA shall be considered after a renewal application has been filed and there has been no change
ir the applicable building code negatively affecting the performance of this product.
TFMAIIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
ff terials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
f • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
o this NOA shall be cause for termination and removal of NOA.
i
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
e piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
i its entirety.
SPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
is NOA renews NOA #14-1I20.04 and consists of pages 1 through 7,
e submitted documentation was reviewed by Gaspar J Rodriguez.
NOA No:: a5-0721.04
Expiration Date: 1210=0
Approval Date: 11/05/15
Page 1 of 7
I
f,
i
R
OFiNG ASSEmny APP120VAL
C
*gory: Roofmg
Su
-Category: Roofing Tiles
M
terial: Concrete
1.
PRODUCT DESCRI noN
Manufactured by Dimensions
Test
Product
Applicant
Specifications
Descriotion
Pla
tation Tile Length: 16'/?
TAS 112
Flat concrete roof tile for direct deck or
Width: 13'
battened nail -on, mortar or adhesive set
applications.
Tri
a Pieces L = varies
TAS 112
Accessory trim, concrete roof pieces for
W = varies
use at hips, rakes, ridges and valley
Varying thickness
terminations. Manufactured for each file
profile.
2.
. MANUFACTURING LOCATION
I
1. Okeechobee, FL
2.2
SUBMITTED EVIDENCE:
Test Aaency Test Identifier
Test NanmelReport Date
An4erican
Test Lab of South RT0624.05-14
TAS 112 07/03/14
Re
land Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
T
Center for Applied
94-060B
Static Uplift Testing
Match, 1994
E�
ineering, Inc.
94-084
PA 101(Adhesive Set)
May 1994
(Mortar Set)
j R
land Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix Il
PA 108 {Nail -On)
i
Re
Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
Re
fland Technologies
P0631-01
Wind Tunnel Testing
July 1994
PA 108 (Mortar Set)
Rc
fland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The
Center -for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering,
Inc.
Test #MDC-76
PA 100
W
lker Engineering, Inc.
Calculations
Aerodynamic Multiplier
March 1999
April 1999
W6,1ker
Engineering, Inc.
Calculations
25-7183
March 1995
25-7094
February 1996
25-7496
April 1996
NOA No.:15-0721.04
Expiration Date: 12/08/20
Approval Date: 11/M/15
Page 2 of 7
2.
rSi<JBmI'I'n ! EvmENCE:
Test Agency
Test Identifier
Test Name/Renort
Date
Wal
I er Engineering, Inc.
Calculations
25-7584
December 1996
25-7804b-8
25-7804-4 & 5
25-7848-6
Wa
er Engineering, Inc.
Calculations
Two Patty Adhesive Set System
April 1999
Fara
augh Engineering and
T295-11
TAS-108
10/05/11
Test
g Inc.
Fara
augh Engineering and
T306-11
TAS-108
10/04/11
Test
ng Inc.
Far
augh Engineering and
T279-11
TAS-108
09/23/11
Test
ng Inc.
3.
1 l<16RITATI®NS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61 G20 3 of the Florida Administrative Code.
NOA. No.: 15-0721.04
Expiration Date: 12/08i20
Approval Date: 11/05/15
Page 3 of 7
INSTALLATION
4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile. Profile
Weight--W (ibf)
Length-1(ft)
Wlelth-w (ft)
Plan
ation Tile
11.6
1.375
1.08
Table 2: Aerodynamic Multipliers - 1 (0)
l
Tile
Profile
X (ft3)
Batten Application
2, (ft3)
Direct Deck Application
Plan
ation Tile
0.267
0.289
Table 3: Restoring
Moments due to Gravity - M (ft Ibf)
T
e
Greater than
Pr
file
2". 12"
3".12"
-V: 12"
51112"
6"• 12"
7":12"
Battens
I Direct
Battens
I Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Deck
Deck
Deck
Deck
I
Deck
Deck
Plan
-Tile
ation
',�
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
1 7.32
6.26
7.04
NOA No.:15-0721.04
Expiration Date:12/08/20
Approval Date: 11/05/15
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-ibf)
For Mall -On Systems
Tile
Fastener Type
Direct Deck
Direct Deck
Battens
Profile
(Alin 16132"
(Min.19/32"
plywood)
plywood)
Planation
Tile
2-10d Ring Shank
30.9
38.1
17.2
Nails
1-10d Smooth or
7.3
9.8
4.9
Screw Shank !Vail
2-10d Smooth or
14.0
18.8
7.4
Screw Shank Nails
1 #8 Screw
30.8
30.8
18.2
2 #8 Screw
51.7
51.7
24.4
1-10d Smooth or
24.3
24.3
24.2
Screw Shank Nail
Field Clip)
1-10d Smooth or
19.0
19.0
22.1
Screw Shank Nail
Eave Clip)
2-10d Smooth or
35.6
35.5
34.8
Screw Shank Nails
Field Clip)
2-10d Smooth or
31.9
31.9
32.2
Screw Shank Nails
Eave Clip)
2A Od Ring Shank
50.3 65.5
4$.3
Nails'
l 161stallation
with a 4' the
headlap and fasteners are located a minimum of 2W from the head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
For Two Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Plantation
Tile
Adhesive
31.33
2 S' a manufactures component approval for installation requirements.
3 F
�)dble Products Company WeBond Average weights per patty 13.9 grams.
W 2-Component Foam Roof Tie Adhesive AH-160. Avera a weight pera S grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Single Patty Adhesive Set Systems
Tile Profile
Tile Application
Minimum Attachment Resistance
Plan
ation Tile
3W 2-Component Foam Roof Tile Adhesive AH-160
118.94
3Mm 2-Component Foam Roof Tile Adhesive AH-160
40.45
4 Urge
paddy placement of 45 grams of 3W 2-Component Foam Roof Tile Adhesive AH-160
5 M6d!um'paddy
placement of 24 grams of 3M'" 2-Component Foam Roof Tile Adhesive AH-160.
NOA No.: 15-0721.04
(Expiration Date.121000
Approval Date: 11/05/15
Page 5 of 7
f
'fable 7: Attachment Resistance Expressed as a Moment - Mt(ft-ibf'
for Mortar Set Systems
Tile Profile
Tile Application Attachment
Resistance
Seespecific mortar manufacturer's Notice of Acceptance;
5. LABELING
All tiles shall bear the imprint or identifiable marldng of the manufacturer's name or logo as seen below or following
sta went: "Miarni-Dade County Product Control Approved".
OR
ENTEGRA7.�
PLANTATION Rom TILE LABEL (LOCATED ON YINDE im. OI FILE)
6. B ummgNG PERT nT R EQUMEMENTS.
.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
I
i
NOA No.- 15-0721.04
rt[ANOADE�cou�vnr Expiration Date,12108120
Approval Date: 11/'05115
Page 6 of 7
PROFILE DRAWING
PLANTATION FLAT CUNCRETE FILE
END OF TMS ACCEPTANCE
NOA.No.:15-0,721.04
Expiration Date: 12/08/20
Approval Date:11/05/15
Page 7 of 7
RECEIVED
AUG 0 3 2018
ST. Lucie County, Ps)rmftting MIAMI-DADE COUNTY
DUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEP r 1,TMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARR AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NO' CE OF ACCEPTANCE (NOA) www.miamidade aov/economy
ICP A.dhesives and Sealants, Inc.
12505W 44a° Street
Coral prngs, FL. 33065 FILE COPY
S+CO E:
This OA is being issued under the applicable rules and regulations governing the use of construction materials. The
doc nta .on submitted has been reviewed and accepted by Miami -Dade County RER Product Control Section to be
used' Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This ,OA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Mirrial
Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or mat tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manuf cturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of suet product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
deterrTned by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the „pplicable building code.
This �oduct is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
PTION: 1CP Adhesives Polyset' AH-160
iG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
"Miami -Dade County Product Control Approved", unless otherwise noted herein.
REN#1 VAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the 4pplicable building code negatively affecting the performance of this product.
1 E)(INVATION of this NOA will occur after the expiration date or if there has been a revision or change in the
maten ls, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this N A shall be cause for termination and removal of NOA.
ISEN ENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its
INSPIEICTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall b available for inspection at the job site at the request of the Building Official.
This N A renews NOA 16-0315.01 and consists of pages 1 through 11.
The su ptted documentation was reviewed by Alex Tigera.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
RO ING COMPONENT APPROVAL:
Cate g ry: Roofing
Sub C tegory: Roof file adhesive
Mate als: Polyurethane
This a roves ICP Adhesives Polyset® AR-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
JPdPh'e
otce of Acceptance. For the locations where the design pressure requirements, as determined by applicable
code, do not exceed the design pressure values obtained by calculations in compliance vsrith Roofing
ion Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
es Polyset° AH-160.
CTS MANUFACTURED BY APPLICANT:
Dimensions Test Product Description
Specifications
hesives N/A TAS 101 Two component polyurethane foam adhesive
PolyTesives
AH-160
ICP Foam N/A Dispensing Equipment
Dispe �er RTF1000
ICP A ihesives ProPack-0 N/A Dispensing Equipment
30&16
PRO U' CTS NIANU1FACTURED BY OTHERS:
Any M ami Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistarlice values with the use of ICP Adhesives Polyset' AH-160 roof file adhesive.
MAN�j3FACTURING LOCATION:
1. Tomball, TX.
PHYS
CAL PROPERTIES:
Property
Test
Results
Densi
ASTM D 1622
1.6 lbs./ft.3
Compr
sive Strength
ASTM D 1621
18 PSI Parallel to rise
12 PSI Perpendicular to rise
Tensile
trength
ASTM D 1623
28 PSI Parallel to rise
Water
bsorption
ASTM D 2127
0.08 Lbs./Ft2
Mois
Vapor Transmission
ASTM E 96
3.1 Perm / Inch
Dime
onal Stability
ASTM D 2126
+0.07% Volume Change @ -40' F., 2 weeks
+6.0% Volume Change @158°F., 100% Humidity, 2
weeks
Closed
ell Content
ASTM D 2856
86%
Note: T
e physical properties listed
above are presented as typical average values as determined by
a
epted ASTM test methods
and are subject to normal manufacturing variation.
NOA No.: 17-0322.03
httart
tp� fug
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2of11
t
E
NCE SUBMITTED.
Test Agency
Test Identifier
Test Name/Reipo
Date
Center
or Applied Engineering
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/16/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Iiaboratories
NB-589-631
ASTM D 1623
02/01/94
Polym
Division
Rai a
Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
South
st Research Institute
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[l]
ASTM E 84
01/16/95
Trinity
ngineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex
Coip. Testing Services
528454-2-1
TAS 101
10/23/98
528454-9-1
528454-10-1
520109-1
TAS 101
12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1
TAS 101
03/02/99
520109-2-1
11 MI ATIONS:
Y. F re classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. 1 P Adhesives Polyset* AH-160 shall solely be used with flat, low, & high the profiles.
3. inimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. of Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset° AH-160 roof file adhesive
th their file assemblies shall test in accordance with TAS 101.
5. 1 products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
R le 61G20-3 of the Florida Administrative Code.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 3 of 11
I. �CP Adhesives Polyset' AH-160 maybe used with any roof tile assembly having a current NOA that lists
ttachment resistance values with the use of ICP Adhesives Polysee AH-160.
2. CP Adhesives Polyset� AH-160 shall be applied in compliance with the Component Application section and the
orresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
dhesives Polysee AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
etermined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
ttachment data is noted in the roof tile assembly NOA.
3. CP Adhesives Polyset'�' AH-160 and its components shall be installed in accordance with Roofing Application
tandard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. stallation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
ealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
5. alibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application
f any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
].0-1.15 (A): 1.0 (B).
6.
7.
S.
9.
Adhesives Polysetl AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP
esives ProPack' 30 & 100 dispensing equipment only.
Adhesives Polysee AH-160 shall not be exposed permanently to sunlight.
must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
sets AH-160 has been dispensed.
Adhesives Polysee AR-160 placement and minimum patty weight shall be in accordance with the
:ement Details' herein. Each generic tile profile requires the specific placement noted herein.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
]Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Area
Minimum Paddy Gram
Weight
Ea v IlCourse
- Flat, Low, High
All Eave Course
17-23 sq. inches
45-65
Profiles
Flat, '
w, High Profiles
#1
17-23 sq. inches
45-65
Flat
Qfile
42
10-12 sq. inches
30
Low P
ofile
#2
12-14 sq. inches
30
High
'rofile
#2
17-19 sq. inches
30
Flat, L'ow,
High Profiles
#3
Two Paddy s: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two-P
ece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge)20-25 sq. inches each
bead
Two P
ece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
Al' app owed products listed herein shall be labeled and shall bear the imprint or identifiable marking of the
manufa tuner's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade C unty Product Control Seal as shown below.
Bum G PEwmn REQUIREMENTS:
As req red by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
.expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
ADHESIVE PLACEMENT DETAIL # 1
Flat/Low 1Pro%le Tile
l . Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cn') — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
l Ugh Profile / Single Pan Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive
contact with the underside of the tile.
N®A No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
]Page 6 of 11
-AD1iESIVE PLACEMENT DETAIL # 2
Elatt Lew Pro le Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the file closest to the overlock of
the file being set. Insure approximately 17 (109.7 cmz)
— 23 (148.4 cm'-) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cm') - 12 (77.4 cm') square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tale
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm'-) —
23 (148.4 cmz) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x T (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cm'-) square inch adhesive
contact with the underside of the tile.
(Instructions continued on nextpage)
NOA No.: 17-0322.03
Expiration bate: 05/10/22
Approval Date: 04/27/17
Page 7 of 11
ADREs E PLACEMENT DETAIL # 2 (CONTINUED)
High ➢'rofi➢e I Single Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm) -
23 (148.4 cmz) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
tmderlayment positioned as shown under the pan
portion of the file closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 17"
(109.7 cm) - 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
N®A No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 8 of 11
41 D ESAVE PLACEMENT DETAiLL # 3
Hata *i?iasi9le'ae
�tc�3l9e'
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat file or under the pan
portion of the tile for low or high profile tile closest
to the overlock of the file being set. Leave
approximately 4" (101.6 nun) up from the eave
edge free of foam to prevent the expanded adhesive
from blocldng the weep holes. Insure
approximately 17-23 inZ (109.7-148.4 cm) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the imderlock for
the second course tile to be installed. Insure
approximately 8-9 in2 (51.6-58.1 cm'-) of adhesive
contact with the underside of the tile.
(Instructions continued on nact page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 9of11
r DETAIL # 3 (CONTINUED)
3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4"
(19 mm) paddy on top of the eave course tile
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the first course of tile.
Install second course of tile. Insure approximately
9 (58.1 cmZ) -11 (71crn-) square inch adhesive
contact with the underside of the tile at the overlap
and 7 (45.2 cmz) - 9 (58.1 cmz) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expirations Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
r
1)
to
ace enough adhmhreto achieve'65 to 70
MtactWkhthepan'tda
un covers upside da"Maccadhesive€a
in.fromoutside edgeofcavertlh A
I instau thfttiie..Fnsuri� 26to
Vndedayment
v
JOsure
ih'91e Fasda
ADHESIVE PLACEMENT DETAm
Two PIECE BARREL
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
�itPcaeimris (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocking until adhesive has a chance to
cure.
Two Piece -Barrel - High Prafiletie
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cmZ) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
cc�u.sgaf edge of each side of the cover tile. Leave
Jim approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan tile course. Insure a minimum of
20 (129 cmz) - 25 (161.3 cm`) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) nailers or the tie wire
system using galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF THIS ACCEPTANCE
N®A No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11