Loading...
HomeMy WebLinkAboutNOA ROOF TILE--------------- RECEIVED GGANNE By AUG 0 3 2098 -L-Uoli20oanti 15T. LWCle County, Permitr•,- MIENT OF REGULATORY AND ECONOMIC RESOURCES (RER) AND CODE ADMINISTRATION DIVISION [CE OF ACCEPTANCE (NOA) ma Aloof Tile, LL'C NE 91" hobee, °e FILE COPY :chobee, FL 34972 liIA14II DAIDE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786) 315.2590 F (786) 315 2599 ww .miamidade eo-0eeenomv OPE: i NOA is being issued under the applicable rules and regulations governing the use of construction materials. The umentation submitted bas been reviewed and accepted by Miami -Dade County RER -Product Control Section to be i in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). T is NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this pr Nutt or material tested for quality assurance purposes. if this product or material fails to perform in the accepted in er, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or su pend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if ft is determined by Miami -Dade County Product Control Section that this product or material fails to meet the reuirements of the applicable building code. T is product is approved as described herein, and has been designed to comply with the Florida Building Cods in;luding the Idigh Velocity Hurricane Zone of the Florida Building Code. JESCRIPTION: Plantation Roof Tile FLING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following st ternent: "Miami -Dade County Product Control Approved", unless otherwise noted herein. NEWAIL of this NOA shall be considered after a renewal application has been filed and there has been no change ir the applicable building code negatively affecting the performance of this product. TFMAIIINATION of this NOA will occur after the expiration date or if there has been a revision or change in the ff terials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, f • sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section o this NOA shall be cause for termination and removal of NOA. i ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the e piration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done i its entirety. SPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. is NOA renews NOA #14-1I20.04 and consists of pages 1 through 7, e submitted documentation was reviewed by Gaspar J Rodriguez. NOA No:: a5-0721.04 Expiration Date: 1210=0 Approval Date: 11/05/15 Page 1 of 7 I f, i R OFiNG ASSEmny APP120VAL C *gory: Roofmg Su -Category: Roofing Tiles M terial: Concrete 1. PRODUCT DESCRI noN Manufactured by Dimensions Test Product Applicant Specifications Descriotion Pla tation Tile Length: 16'/? TAS 112 Flat concrete roof tile for direct deck or Width: 13' battened nail -on, mortar or adhesive set applications. Tri a Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for W = varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each file profile. 2. . MANUFACTURING LOCATION I 1. Okeechobee, FL 2.2 SUBMITTED EVIDENCE: Test Aaency Test Identifier Test NanmelReport Date An4erican Test Lab of South RT0624.05-14 TAS 112 07/03/14 Re land Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) T Center for Applied 94-060B Static Uplift Testing Match, 1994 E� ineering, Inc. 94-084 PA 101(Adhesive Set) May 1994 (Mortar Set) j R land Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix Il PA 108 {Nail -On) i Re Technologies Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 PA 108 (Nail -On) Re fland Technologies P0631-01 Wind Tunnel Testing July 1994 PA 108 (Mortar Set) Rc fland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center -for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-76 PA 100 W lker Engineering, Inc. Calculations Aerodynamic Multiplier March 1999 April 1999 W6,1ker Engineering, Inc. Calculations 25-7183 March 1995 25-7094 February 1996 25-7496 April 1996 NOA No.:15-0721.04 Expiration Date: 12/08/20 Approval Date: 11/M/15 Page 2 of 7 2. rSi<JBmI'I'n ! EvmENCE: Test Agency Test Identifier Test Name/Renort Date Wal I er Engineering, Inc. Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Wa er Engineering, Inc. Calculations Two Patty Adhesive Set System April 1999 Fara augh Engineering and T295-11 TAS-108 10/05/11 Test g Inc. Fara augh Engineering and T306-11 TAS-108 10/04/11 Test ng Inc. Far augh Engineering and T279-11 TAS-108 09/23/11 Test ng Inc. 3. 1 l<16RITATI®NS 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix W. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20 3 of the Florida Administrative Code. NOA. No.: 15-0721.04 Expiration Date: 12/08i20 Approval Date: 11/05/15 Page 3 of 7 INSTALLATION 4.1 Plantation Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile. Profile Weight--W (ibf) Length-1(ft) Wlelth-w (ft) Plan ation Tile 11.6 1.375 1.08 Table 2: Aerodynamic Multipliers - 1 (0) l Tile Profile X (ft3) Batten Application 2, (ft3) Direct Deck Application Plan ation Tile 0.267 0.289 Table 3: Restoring Moments due to Gravity - M (ft Ibf) T e Greater than Pr file 2". 12" 3".12" -V: 12" 51112" 6"• 12" 7":12" Battens I Direct Battens I Direct Battens Direct Battens Direct Battens Direct Battens Direct Deck Deck Deck Deck I Deck Deck Plan -Tile ation ',� 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 1 7.32 6.26 7.04 NOA No.:15-0721.04 Expiration Date:12/08/20 Approval Date: 11/05/15 Page 4 of 7 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-ibf) For Mall -On Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (Alin 16132" (Min.19/32" plywood) plywood) Planation Tile 2-10d Ring Shank 30.9 38.1 17.2 Nails 1-10d Smooth or 7.3 9.8 4.9 Screw Shank !Vail 2-10d Smooth or 14.0 18.8 7.4 Screw Shank Nails 1 #8 Screw 30.8 30.8 18.2 2 #8 Screw 51.7 51.7 24.4 1-10d Smooth or 24.3 24.3 24.2 Screw Shank Nail Field Clip) 1-10d Smooth or 19.0 19.0 22.1 Screw Shank Nail Eave Clip) 2-10d Smooth or 35.6 35.5 34.8 Screw Shank Nails Field Clip) 2-10d Smooth or 31.9 31.9 32.2 Screw Shank Nails Eave Clip) 2A Od Ring Shank 50.3 65.5 4$.3 Nails' l 161stallation with a 4' the headlap and fasteners are located a minimum of 2W from the head of tile. Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) For Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plantation Tile Adhesive 31.33 2 S' a manufactures component approval for installation requirements. 3 F �)dble Products Company WeBond Average weights per patty 13.9 grams. W 2-Component Foam Roof Tie Adhesive AH-160. Avera a weight pera S grams. Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) For Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Plan ation Tile 3W 2-Component Foam Roof Tile Adhesive AH-160 118.94 3Mm 2-Component Foam Roof Tile Adhesive AH-160 40.45 4 Urge paddy placement of 45 grams of 3W 2-Component Foam Roof Tile Adhesive AH-160 5 M6d!um'paddy placement of 24 grams of 3M'" 2-Component Foam Roof Tile Adhesive AH-160. NOA No.: 15-0721.04 (Expiration Date.121000 Approval Date: 11/05/15 Page 5 of 7 f 'fable 7: Attachment Resistance Expressed as a Moment - Mt(ft-ibf' for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Seespecific mortar manufacturer's Notice of Acceptance; 5. LABELING All tiles shall bear the imprint or identifiable marldng of the manufacturer's name or logo as seen below or following sta went: "Miarni-Dade County Product Control Approved". OR ENTEGRA7.� PLANTATION Rom TILE LABEL (LOCATED ON YINDE im. OI FILE) 6. B ummgNG PERT nT R EQUMEMENTS. .1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. I i NOA No.- 15-0721.04 rt[ANOADE�cou�vnr Expiration Date,12108120 Approval Date: 11/'05115 Page 6 of 7 PROFILE DRAWING PLANTATION FLAT CUNCRETE FILE END OF TMS ACCEPTANCE NOA.No.:15-0,721.04 Expiration Date: 12/08/20 Approval Date:11/05/15 Page 7 of 7 RECEIVED AUG 0 3 2018 ST. Lucie County, Ps)rmftting MIAMI-DADE COUNTY DUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEP r 1,TMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARR AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599 NO' CE OF ACCEPTANCE (NOA) www.miamidade aov/economy ICP A.dhesives and Sealants, Inc. 12505W 44a° Street Coral prngs, FL. 33065 FILE COPY S+CO E: This OA is being issued under the applicable rules and regulations governing the use of construction materials. The doc nta .on submitted has been reviewed and accepted by Miami -Dade County RER Product Control Section to be used' Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This ,OA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Mirrial Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or mat tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manuf cturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of suet product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is deterrTned by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the „pplicable building code. This �oduct is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. PTION: 1CP Adhesives Polyset' AH-160 iG: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following "Miami -Dade County Product Control Approved", unless otherwise noted herein. REN#1 VAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the 4pplicable building code negatively affecting the performance of this product. 1 E)(INVATION of this NOA will occur after the expiration date or if there has been a revision or change in the maten ls, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this N A shall be cause for termination and removal of NOA. ISEN ENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its INSPIEICTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall b available for inspection at the job site at the request of the Building Official. This N A renews NOA 16-0315.01 and consists of pages 1 through 11. The su ptted documentation was reviewed by Alex Tigera. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 RO ING COMPONENT APPROVAL: Cate g ry: Roofing Sub C tegory: Roof file adhesive Mate als: Polyurethane This a roves ICP Adhesives Polyset® AR-160 as manufactured by ICP Adhesives and Sealants, Inc. as described JPdPh'e otce of Acceptance. For the locations where the design pressure requirements, as determined by applicable code, do not exceed the design pressure values obtained by calculations in compliance vsrith Roofing ion Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP es Polyset° AH-160. CTS MANUFACTURED BY APPLICANT: Dimensions Test Product Description Specifications hesives N/A TAS 101 Two component polyurethane foam adhesive PolyTesives AH-160 ICP Foam N/A Dispensing Equipment Dispe �er RTF1000 ICP A ihesives ProPack-0 N/A Dispensing Equipment 30&16 PRO U' CTS NIANU1FACTURED BY OTHERS: Any M ami Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistarlice values with the use of ICP Adhesives Polyset' AH-160 roof file adhesive. MAN�j3FACTURING LOCATION: 1. Tomball, TX. PHYS CAL PROPERTIES: Property Test Results Densi ASTM D 1622 1.6 lbs./ft.3 Compr sive Strength ASTM D 1621 18 PSI Parallel to rise 12 PSI Perpendicular to rise Tensile trength ASTM D 1623 28 PSI Parallel to rise Water bsorption ASTM D 2127 0.08 Lbs./Ft2 Mois Vapor Transmission ASTM E 96 3.1 Perm / Inch Dime onal Stability ASTM D 2126 +0.07% Volume Change @ -40' F., 2 weeks +6.0% Volume Change @158°F., 100% Humidity, 2 weeks Closed ell Content ASTM D 2856 86% Note: T e physical properties listed above are presented as typical average values as determined by a epted ASTM test methods and are subject to normal manufacturing variation. NOA No.: 17-0322.03 httart tp� fug Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2of11 t E NCE SUBMITTED. Test Agency Test Identifier Test Name/Reipo Date Center or Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/16/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Iiaboratories NB-589-631 ASTM D 1623 02/01/94 Polym Division Rai a Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 South st Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[l] ASTM E 84 01/16/95 Trinity ngineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Coip. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 11 MI ATIONS: Y. F re classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. 1 P Adhesives Polyset* AH-160 shall solely be used with flat, low, & high the profiles. 3. inimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. of Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset° AH-160 roof file adhesive th their file assemblies shall test in accordance with TAS 101. 5. 1 products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and R le 61G20-3 of the Florida Administrative Code. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 3 of 11 I. �CP Adhesives Polyset' AH-160 maybe used with any roof tile assembly having a current NOA that lists ttachment resistance values with the use of ICP Adhesives Polysee AH-160. 2. CP Adhesives Polyset� AH-160 shall be applied in compliance with the Component Application section and the orresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP dhesives Polysee AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value etermined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive ttachment data is noted in the roof tile assembly NOA. 3. CP Adhesives Polyset'�' AH-160 and its components shall be installed in accordance with Roofing Application tandard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. stallation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and ealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having 5. alibration of the ICP Adhesives Foam Dispenser RTF1000 dispensing equipment is required before application f any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between ].0-1.15 (A): 1.0 (B). 6. 7. S. 9. Adhesives Polysetl AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF 1000 or ICP esives ProPack' 30 & 100 dispensing equipment only. Adhesives Polysee AH-160 shall not be exposed permanently to sunlight. must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives sets AH-160 has been dispensed. Adhesives Polysee AR-160 placement and minimum patty weight shall be in accordance with the :ement Details' herein. Each generic tile profile requires the specific placement noted herein. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 ]Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Area Minimum Paddy Gram Weight Ea v IlCourse - Flat, Low, High All Eave Course 17-23 sq. inches 45-65 Profiles Flat, ' w, High Profiles #1 17-23 sq. inches 45-65 Flat Qfile 42 10-12 sq. inches 30 Low P ofile #2 12-14 sq. inches 30 High 'rofile #2 17-19 sq. inches 30 Flat, L'ow, High Profiles #3 Two Paddy s: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two-P ece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge)20-25 sq. inches each bead Two P ece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan Al' app owed products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufa tuner's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miami - Dade C unty Product Control Seal as shown below. Bum G PEwmn REQUIREMENTS: As req red by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 .expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 ADHESIVE PLACEMENT DETAIL # 1 Flat/Low 1Pro%le Tile l . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cn') — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. l Ugh Profile / Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cmZ) — 23 (148.4 cmZ) square inch adhesive contact with the underside of the tile. N®A No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 ]Page 6 of 11 -AD1iESIVE PLACEMENT DETAIL # 2 Elatt Lew Pro le Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the file closest to the overlock of the file being set. Insure approximately 17 (109.7 cmz) — 23 (148.4 cm'-) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cm') - 12 (77.4 cm') square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tale Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm'-) — 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x T (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cm'-) square inch adhesive contact with the underside of the tile. (Instructions continued on nextpage) NOA No.: 17-0322.03 Expiration bate: 05/10/22 Approval Date: 04/27/17 Page 7 of 11 ADREs E PLACEMENT DETAIL # 2 (CONTINUED) High ➢'rofi➢e I Single Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm) - 23 (148.4 cmz) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the tmderlayment positioned as shown under the pan portion of the file closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 17" (109.7 cm) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. N®A No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 8 of 11 41 D ESAVE PLACEMENT DETAiLL # 3 Hata *i?iasi9le'ae �tc�3l9e' On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat file or under the pan portion of the tile for low or high profile tile closest to the overlock of the file being set. Leave approximately 4" (101.6 nun) up from the eave edge free of foam to prevent the expanded adhesive from blocldng the weep holes. Insure approximately 17-23 inZ (109.7-148.4 cm) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1" (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the imderlock for the second course tile to be installed. Insure approximately 8-9 in2 (51.6-58.1 cm'-) of adhesive contact with the underside of the tile. (Instructions continued on nact page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 9of11 r DETAIL # 3 (CONTINUED) 3. Also apply a 2" (50.8 mm) x 4" (101.6 mm) x 3/4" (19 mm) paddy on top of the eave course tile surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the first course of tile. Install second course of tile. Insure approximately 9 (58.1 cmZ) -11 (71crn-) square inch adhesive contact with the underside of the tile at the overlap and 7 (45.2 cmz) - 9 (58.1 cmz) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expirations Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 r 1) to ace enough adhmhreto achieve'65 to 70 MtactWkhthepan'tda un covers upside da"Maccadhesive€a in.fromoutside edgeofcavertlh A I instau thfttiie..Fnsuri� 26to Vndedayment v JOsure ih'91e Fasda ADHESIVE PLACEMENT DETAm Two PIECE BARREL Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" �itPcaeimris (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocking until adhesive has a chance to cure. Two Piece -Barrel - High Prafiletie 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cmZ) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner cc�u.sgaf edge of each side of the cover tile. Leave Jim approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan tile course. Insure a minimum of 20 (129 cmz) - 25 (161.3 cm`) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) nailers or the tie wire system using galvanized, stainless steel, or copper wire and compatible nails may be used. END OF THIS ACCEPTANCE N®A No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11