Loading...
HomeMy WebLinkAbout0502-1081-DESIGN CERTIFICATION FOR WIND LOAD COMPLIANCESCANNED a V . St. Lucie County >Y1 1 �CRR 'ng and Zoning Department 2300 Virl nia A -venue „a Fort Pierce, FL 34982 , Py 561F -462.1553 L Design Certification for Wind Lead Compliance This ertification is to be completed by the project design architect or engineer. This Certification must be submitted with all avvlic 4ions for building aermits involving the construction of new residence (single or multi• family). -residential addition, anv aceessry structure requiring a building permit, and any nonresidential structurt. This Certification shall not apply to interior rdnuvaiiuns (provided that no structural walls, columns or other similar component is being effected) edd Certain ether toinor buiidiny; permitj; For further assistance, please contact the Building Inspection Office at 4612-1553 or 462-2172. pto GG 'Il�tamae l U i�l offlca Ube only Street dress 1 permit Number I OccNancy Type Construction T Certi ' cation Statement: I certi that, to the best of my knowledger and belief, these plans' and speciiications have been designed to comps' with the applicable structural portion of the Building Lodes currently adopted and enforced by 5t, Lucie Count; Z also certify that structural elements depicted on these plans provide adequate resistance to the wind loads d forces specified by current code provisions. D Parameters and AssumpoQns Used: (Please check or complete the appropriate box.) rda Building Code 2041 Edition ASCE 7-9$ L n,o 2. $ui Iitxg Resign is (check one) Enclosed �_ Partially Enclosed Open Building �. 3. Bui'I ing Height: is' e N 4. Wind'Speed Used. in Building Design: 12-0 3 second gust B S. Wiry„ Exposure Classiircation (refer to exposure tables in Building Code identified in Line M; _ 6, Ave age Wind velocity Pressure on Exterior Faces of Structure 2 _ PSF 7. Pe Wind Velocity Pressure on Exterior paces of Structure 8. imp riance/UJse Factor (obtain from Building Code); 1 o 9. Jlao $: Floor JS _PSF Kbof/dead 25 P5F Roof/live 3 ° P5F 1.0. We Shear Walls Considered for Structure (check one): Yes X _ .__ No (If No, attach explanation) .11.18 Candnualte ]Amd Path Providpil(eherk ann)t Y+es , X No — (If Nn, attach sxplanatin") 12. A Campor*ot and Cladding Detail Provided (check one): Yes K No (if No, attach explanation) 13. M 'mum Soil Bearing Pressure: 25 >0 PSF As wit sed by my seal, I hereby certify that the information included with this certification is true and correct to the beet of my knowledge and belief. Nan= Design Scwt� S. DtSher AI A Certification 9. Aaoo 115 8 ! [Seal Here] Wald n: Sca* BIG kc i lee n t v bar .*Assoc Date; —at • • sLCCDV Fom # 020-00