Loading...
HomeMy WebLinkAbout0502-1081-SURVEYGAA INED BY MIN. SETBACK REQ. RRONr SIDES CNR SIDES REAR ZNG. TECH, BUILDING SETBAL KZ): FRONT= 20' (SIDE LOAD GARAGE) FRONT= 25' (FRONT LOAD GARAGE) REAR= 15'. REAR= 3' (WITH PATIO/POOL DECK/ SCREEN) SIDE= 6' MODEL: "FAIRVIEW" LOT GRADING TYPE: "A" L=37.10' COMMON AREA MAIDSTONE , P.B . .B. 43, PGS 11,11A-11C r.,,. ` A&ar'� N robi l IF 10-1 �J PROPOSED COLUMN PROPOSED COVERED PATIO' LOT 137 PROPOSED RESIDENCE PROPOSED F.F. = 29.2 rs o. \j LOT 136 MAIDSTONE P. B. 43 Pgs 11,11A-11C ABBREVIATION LEGEND P.C. — POINT OF CURVATURE P.R.C. — POINT OF REVERSE CURVATURE P.C.C. — POINT OF COMPOUND CURVATURE P.T. — POINT OF TANGENCY ( _ PLAT P.I. — POINT OF INTERSECTION ) M — MEASURED P.C.P. — PERMANENT CONTROL POINT P.O.L. — POINT ON LINE (C) —CALCULATED P.R.M. — PERMANENT REFERENCE MONUMENT (E) — ENGINEERING PLAN C.B. — CHORD BEARING (A) — ACTUAL C.M. — CONCRETE MONUMENT CONC. — CONCRETE P.B. — PLAT BOOK Pg. — PAGE C.L.F. — CHAIN LINK FENCE N.R. — NON —RADIAL W.F. — WOOD FENCE RAID. — RADIAL C & G — CURB & GUTTER R. — RADIUS CAN — CABLE TELEVISION RISER L. — ARC LENGTH_ T • — TELEPHONE RISER NS_ —_ — — DE R.P. — RADIUS POINT L.P. __TR_ANSMRMEh Pf — LIGHT POLE R/W — RIGHT—OF—WAY P.P. — POWER POLE q — CENTER LINE NG — NATURAL GROUND SQ. FT. — SQUARE FEET EL. — ELEVATION W.M. — WATER METER A/C — AIR CONDITIONER F.H. — FIRE HYDRANT TYP-- TYPICAL N & D _ — NAIL AND DISC U.E. — UTILITY EASEMENT B.M. — BENCH MARK D.E. — DRAINAGE EASEMENT PVMT. — PAVEMENT D/U — DRAINAGE AND UTILITY EASEMENT F.B. — FIELD BOOK F.F. — FINISHED FLOOR — BUILDING SETBACK LINE FND — FOUND C.B:S. — CONCRETE BLOCK STRUCTURE REC — RECOVERED N PROPOSED COVERED ENTRY 9 LOT 136 MAIDSTONE N P.B. 43 Pgs 11,11A-11C SCALE: 1"=20' AJ ` 0- 0 R=80.00' / L=39.52' &--28-18'1�- (P)/ / / R=117 00.00' 6 L=47.68' e=-27'19'15" "V PROPOSEDCOLUMN / �c ¢y? V (CJ . PROPOSED DRIVEWAY PROPOSED WALK \�S / L=47.68' / 6 R=100.00' C L=61.96' 10' U.E. I (P) ro c*+v _ N G0� j CENTERLINE /273 M P.C./P.C.P a� ND _ G � 13 P.T./P.C.P 15. 6a�5 �0 - _ _Engineers - - - Planners Landscape Architects / CENTERLINE Ei7shASurveyors 0 / Lot 137, Maidstone according to the plat thereof as recorded in Plat Book 43, pages, .11, 11a, 11b and 11c of the Public Records of St. Lucie County, Florida. Survey Notes: 1. "NOT VALID WITHOUT THE SIGNATURE_AND_THE_ORIGINAL-RAISED— 'SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER". 2. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 135 MAIDSTONE AS RECORDED IN PLAT BOOK 43, PAGES 11 THROUGH 11C OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA AS BEING S 63.02'46" E (PER THE PLAT THEREOF). 3. THE "LEGAL DESCRIPTION" HEREON WAS PREPARED BY THE SURVEYOR PER THE CLIENT'S REQUEST, 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OR OPINION OF TITLE. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS —OF —WAY, AND/OR OWNERSHIP WERE FURNISHED TO THIS SURVEYOR EXCEPT AS NOTED. 5. ELEVATIONS BASED ON SITE BENCHMARKS PROVIDED BY BUILDER AS SET BY OTHERS AS SHOWN ON APPROVED ON ENGINEERING AS—BUILTS. 6. ELEVATIONS SHOWN HEREON WITH A "(E)" ARE PROPOSED PER CONSTRUCTION PLANS PREPARED BY OTHERS AND FURNISHED BY THE CLIENT. 7. NO UNDERGROUND INSTALLATIONS OR VISIBLE IMPROVEMENTS ON SITE OR BEYOND PROPERTY LINES HAVE BEEN LOCATED EXCEPT THOS SHOWN HEREON. CERTIFIED TO: KOLTER HOMES Surveyor's Certification: I hereby certify that the attached "SKETCH OF DESCRIPTION" of the hereon —described property is true ara correct to the best of my knowledge, information and belief as prepared under my direction on Feburary 1, 2005 . I further certify that this "SKETCH OF DESCRIPTION" meets the minimum technical standards set forth in rule 61g17-6 of the Florida Admirysttrative Code. Ralph A. )dieto, P.S.M. Professional Surveyor and Mapper Florida Registration No. 6025 1 FINAL SURVE)? I 1— l Construction Management STAKE OUT W w W. c p h e n g i n e e r s. c o m West Fulton Street, Sanford, Fl. 32771 P.O. Box2808, Sanford, Fl. 32772-2808 PLOT PLAN Phone: 40Z322.6841 Fax: 40Z330.0639 Cer'gicate of JTF I 2/1/05 rn No. 7143 I R=100.00' L=37.10' A--21015'27" COMMON AREA (P) MAIDSTONE P.B. 43, / PGS 11,11A-11C �( / 0,000000, INTERNAL BUILDING SETBACKS: FRONT= 20' (SIDE LOAD GARAGE) FRONT= 25' (FRONT LOAD GARAGE) REAR= 15' REAR= 3' (WITH PATIO/POOL DECK/ SCREEN) SIDE= 6' MODEL: "FAIRVIEW" LOT GRADING _TYPE: "B" Abbreviation Le_nend : *SYMBOLS SHOWN HEREON ARE NOT TO SCALE P.C. - POINT OF CURVATURE P.R.C. - POINT OF REVERSE CURVATURE P.C.C. - POINT OF COMPOUND CURVATURE r.�. r1,0� PROPOSED COVERED PATiO CA 6t- 27.7 LOT 136 MAIDSTONE P.B.- 43 Pgs 11,11 A-11 C P.T. - POINT OF TANGENCY (P) - PLAT P.I. - POINT OF INTERSECTION (E) - MEASURED P.C.P. - PERMANENT CONTROL POINT --POINT (C)) - CALCULATED P.O.L. ON LINE P.R.M. - PERMANENT REFERENCE MONUMENT (E) - ENGINEERING PLAN C.B. - CHORD BEARING (A) - ACTUAL C.M. - CONCRETE MONUMENT CONC. - CONCRETE P.B. - PLAT BOOK C.L.F. - CHAIN LINK FENCE Pg. - PAGE W.F. - WOOD FENCE N.R. - NON -RADIAL C & G - CURB & GUTTER =RAD•= =-RAD1Al _ ATV - CABLE TELEVISION RISER R. - RADIUS -- --- —_ T _ — — L. - ARC LENGTH TRANS - TRANSFORMER PAD 0 - DELTA L.P. - LIGHT POLE R.P. - RADIUS POINT P.P. - POWER POLE R/W - RIGHT-OF-WAY NG - NATURAL GROUND Z - CENTER LINE SO FT - SQUARE FEET EL. - ELEVAMN ---- -- - A/C - AIR CONDITIONER TYP. - TYPICAL U.E. - UTILITY EASEMENT D F- - DRAINAGE EASEMENT D/U - DRAINAGE AND UTILITY EASEMI F.F. - FINISHED FLOOR BSL - BUILDING SETBACK LINE C.B.S. - CONCRETE BLOCK STRUCTURE W:M.- ---WATER-METER- F.H. - FIRE HYDRANT N & D - NAIL AND DISC B.M. - BENCH MARK PVMT. - PAVEMENT M.H. - MANHOLE FND - FOUND REC - RECOVERED / CENTERLINE P.T./P.C.P LOT 137 WOODEN FORMBOARDS PROPOSED F.F. = 29.2 s LOT 136 MAIDSTONE P.B. 43 Pgs 11,11A-11C F 28,0 r SCALE: 1"=20' PROPOSED COVERED ENTRY i r op O• I 29,E R=80.00' / L=39.52' a=28*18'1X" / (PI/ / R=100.00' L=47.68' �=2T19'15" s ?Ooo. rO�RY?3 r'e GpgD¢'F J R=100.00' L=47.68' A-2719'15" P P.C. (C) 60 49 R=100.00' L=61.96' / 6=35'29'53" (P) �/CE�NTER.LLINE P.C./PC.P AS —BUILT SURWY �,i�(�-' LECA1 DEWRIPnay -V- Lot 137, Maidstone, according to the plat thereof, as V ' recorded in Plat Book pages 11a through 11c of the \ Public Records of St. Lucie Countyy,, Florida. Survey Notes: y O 4 �pp5 3. THE 'LEGAL DESCRIPTION" HEREON WAS PREPARED BY THE SURVEYOR PER THE CLIENT'S REQUEST. 4. THIS SURVEY WAS PREPARED WITHOUT THE BENEFIT OF AN ABSTRACT OR OPINION OF TITLE. NO INSTRUMENTS OF RECORD REFLECTING EASEMENTS, RIGHTS —OF —WAY, AND/OR OWNERSHIP WERE FURNISHED TO THIS SURVEYOR EXCEPT AS NOTED. 5. ELEVATIONS BASED ON SITE BENCHMARKS PROVIDED BY BUILDER AS SET BY OTHERS AS SHOWN ON APPROVED ON ENGINEERING AS—BUILTS. 6. ELEVATIONS SHOWN HEREON WITH A "(E)" ARE PROPOSED PER CONSTRUCTION PLANS PREPARED BY OTHERS AND FURNISHED BY THE CLIENT. 7. NO UNDERGROUND INSTALLATIONS OR VISIBLE IMPROVEMENTS ON SITE OR BEYOND PROPERTY LINES HAVE BEEN LOCATED EXCEPT THOSE SHOWN HEREON. 8. BUILDING PAD SET AT 29.40' AT THE DATE OF STAKEOUT SHOWN HEREON AND INCLUDES A .20' ADJUSTMENT UP IN ELEVATION AS REQUESTED BY CLIENT. 9. THIS IS NOT A BOUNDARY SURVEY. THE PURPOSE OF THIS / AS —BUILT 'SURVEY IS TO SHOW THE LOCATION AND ELEVATION OF THE WOODEN FORMBOARDS ON THE PROPOSED LOT. NO CORNERS HAVE BEEEN SET OR RECOVERED AT THE DATE OF THIS SURVEY DUE TO ONGOING SITE CONSTRUCTION. P.T./P.C.P "NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED L OF A FLORIDA LICENSED SURVEYOR AND MAPPER". BEARINGS SHOWN HEREON ARE BASED ON THE NORTHEAST. OF LOT 137 MAIDSTONE AS RECORDED IN PLAT BOOK 43, ES 11 THROUGH 11C OF THE PUBLIC RECORDS OF ST. LUCIE NTY, FLORIDA AS BEING S 46'31'47" E (PER THE PLAT 10. PROPOSED FINISHED FLOORS ARE PER ENGINEERING PLANS PROVIDED BY LBFH INC., AND DATED 06/16/04. CERTIFIED TO: Q� KOLTER HOMES d,5^1 l D U Surveyor's Certification: I hereby certify that the attached "AS —BUILT SURVE,I.i ,of :the hereon —described property Is true and correct,,to the best o ` my knowledge, information and belief as preparei under my'direailon'. on May 2, 2005. 1 further certify that this 'AS7 BUILT SURVEY" �'' meets the minimum technical stondards_3etl:forth in rule Wg17=6 of the Florida Administrative Code. Professional Surveyor and Mapper Florida Registration No. 6025 Engineers REVS OtVBY., vDATE Planners -- Landscape Architects FINAL SURVEY Surveyors AS —BUILT SURVEY JTF 5/3/05 www. ephengineers. c 0 m - 500 West Fulton Street, Sanford, Fl. 32771 P.O. Box 2808, Sanford, Fl. 32772-2808 PLOT PLAN JTF 2/1/05 Phone: 407.322.6841 Fax: 407.330.0639 Certificate of Authorization No, 7143