Loading...
HomeMy WebLinkAboutROLLING FIRE DOORSAtlas up to 14, 12'0" in nished v tories Le Doors c less the high an writers' These di up, chaii operate( and autc still be u Either th F3 slat c, An oscill control t' The trig closing melting 1600 fu smoke Fuse lin ed on b SCANNED nfAv fire doors By F�^r it nn�r�n(f�.nnpp{ ng Steel Fire Doors close ally in case of fire. Doors sq. ft. in area and up to vidth or height are Fur- th Underwriters' Labora- iels Class A, B, C or D. ,er these dimensions but 1 40'0" wide and 30'0" supplied ',with Under- .aboratories oversize ion. ors can bq manual push hoist, crank hoist or motor Although they are U.L. rated natically closing, they can ed as service doors. curved C slat or the flat n be used. sting governor is supplied to e rate of descent when the closing device is activated. gyring of the automatic echanism is a result of the ider the heat of fire of ble links oi� by means of a heat detector. > or detectors can be mount- h sides of1the wall. Class Al- Fire Class B Class C partition Class D Atlas Fir and. liste Laborat( Factory Compar Rolling factured N.J. 088 by the U furnishej icates wl labeling' maximui Operatic operate( gear red chain) (h 12 Vertical (3 hour rating) raft (11/2 hour) - Corridor and room j4 hour) - Exterior walls (11/2 hour) Doors hale been tested by Underwriter's es, Inc., and the Associated utual Fire Insurance I irk specifications ire doors are to be as r)anu- iy Atlas D9or Corp., Edison, 18. They.are to be labeled derwritersj Laboratories or with U.L. oversize certif- ere the opgning exceeds the ize, but isiless than the i oversize designation. n to be (manual, push up (chain hoist operated using ction and galvanized hand ind crank hoist operated { using gears and removable hand crank) (by motor operator). Doors to automatically close in event of fire. Curtains are to be assembled of in- terlocking slats cold roll formed from (galvanized steel) (stainless steel). Gauge of steel is to satisfy Under- writers' Laboratories requirement for label designated. Each end of every slat is to be fitted with a malleable iron endlock to act as a wearing surface in guides, to prevent flame passage, and to maintain slat align- ment. Steel slats are to be galvan- ized with a zinc coating in accor- dance with A.S.T.M. A 525-80. Each curtain is to be reinforced with a bottom bar consiting of two (steel) (stainless steel) angles. Spring counterbalance is to be housed in a steel pipe of diameter and wall thickness to restrict max- imum deflection to .03" per foot of door width. Springs to be helical torsion type designed to include an overload factor of 25% and for optimum ease of operation. Hand chain pull load is not to exceed 35 lbs. Springs are to be grease packed and are to be mounted on a cold rolled steel inner shaft. Spring tension is to be adjustable from outside of end bracket plate. Furnish sealed ball bearings to minimize wear of pipe shaft rotation around inner shaft. Bracket plates carrying pipe counterbalancing shaft are to be of steel plate no less than '/4" thickness. The drive end bracket plate is to be fitted with a sealed ball bearing.. Plates are to house ends of each door coil. Each door is to be equipped with an oscillating governor to control the speed of descent. Guides are to consist of (structural steel) (stainless steel) angles of 3/16" minimum thickness. Hoods to house each coil are to be fabricated of (galvanized steel) (stain- less steel) sheet metal no lighter than #24 U.S. gauge and are to be laterally reinforced. In order to pre- vent sag, furnish intermediate hood supports where door width exceeds 12'011. Locking chain hoist doors are to include a hand chain locking bracket for padlocking chain. Crank hoist doors to include a locking disc on crankbox for padlocking. Gearing for motor operated doors is to be self locking. Fimsh for ungalvanized surfaces is to consist of a shop coat of rust inhib- iting metallic primer. Field painting is not included in this section. Stainless steel to have (#2B) (#4) finish. Installation is to be by manufacturer or his authorized representative. optional featurs-5 Motor operation (add ). Motor operator is to include high starting torque motor, reduction gear- ing, solenoid brake, limit switches for upper and lower limits of door travel, emergency hand chain with elec- trical interlock to break motor c;rcuit when hand chain is engaged, mag- netic relay contactor, overload pro- tection, prewiring to terminal block, and 3 button operating station. Motor is to be removable for repair without effecting emergency opera- tion. Manufacturer is to furnish wiring diagram. Safety edge (add). Safety edges are to be furnished for motor oper- ated doors. Upon contact with obstruction door is to (stop) (stop and reverse to open position). Field wiring is not included in this section. PainVng If all surfaces are to be painted including galvanized mate- rial — substitute the following under the "FiNISH" heading: (Galvanized slats ::nd hoods are to be furnished with a baked on coat of epoxy mod- ified r.olyester. Other surfaces excec t for bearings are to be shop paint._-d with a coat of metallic primt Field painting is not included in thi:­. section). Sea' 'hat are Underwriter's Labora- torie.- fisted (smoke) are to be fur- nish< at the sill, jambs and header. FOR SMOKE DOORS — PAGE 16. 08330/ATL!j j,, i roiling F ' doom 13uyLine 0371 LIII pcking Furnish cylinder locks on bppttom bars ; (masterkeyable to building system). Cylinder locking four motor operated doors to include electrical interlock to pre,- ant door orration before door is Lnlocked. ThIru wall fusible link. Provide 1.fusgible Links on both sides of wall. Srlr' oke detectors and magnetic holders: 1 S l,loke and/or heat detecting devices or , ther fire alarm systems are being us d with increasing frequency to ac'bate-rolling fire doors. These de- vic' s are used in conjunction with elel, tromechanical release units (m gnetic holders). The smoke or he t detectors can be furnished by Atl °s or by other trades as specified buil the magnetic holders must be furnished by the door manufacturer. No field wiring included For Thigh cycle ,or severe duty application corjtact factory. Malgnetic holOers: TyR]6 FS continuously en rgized fail safe unit. Rel 1 ases when there is an iltl terrruption of power supply. Available in 110AC, 24V AC 24 'IDC, 12V DC i i � I I i I I TyR AR releases when current is applied on sign?l from the detector oral rm syste . Avail- ableiwith adjustable tim del a' only in 110I AC e manual operation D + 1 between iambs F12** chain operation 4 F21** 1 D+�1/2- motor operation F41** 4,,.1, „ 1121 „ 217' headroom F F l required at motor operator using MB IAI E operator shown — r masonry opg. width f•--t—wsee pages 29-30. *4" is dimension of top hood reinforcing bead. Where headroom is limited 4" requirement can be eliminated by turning bead down. Where units are mounted above ceiling, coil must be raised at least 7" above ceiling to allow dropout mechanism to function for automatic closing. height H D to 710" 16" 7'0%8" to 817" 17" 87%8" to 1110" 18" 11 '0'/8" to 127" 19" 12'7'/s" to 1517" 20" 1571/8" to 18'0" 21" r width W A B C E F to 8'0" 81/2" 81/4 " 81/2 " 91/2" 812" 8'0" to 12'0" 81/2" 83/4" 8%11 10" 83�" 1210" to 18'0" 81/2" 91/2" 91/2" 101/2" 8%" 18'0" to 24'0" 91/2" — 101/2" 11" — "Two letter suffix defines curtain material. (GS) Galvanized steel unpainted. (PS) Galvanized steel with baked coat of epoxy modified polyester. (ST) Stainless steel. j ern®ke detectors: 1 •\�_v y�, Photo electric type can be Ionization type available furnished with heat detector for 115 volt. Trim, compact, as well. Available for 115 volt low profile design. U.L. service, U.L. listed. listed. 13