Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEr., . FLORIDA ENERGY EFFICIENCY CODE C — FOR BUILDING CONSTRUaCTIft * ORM 9OO-A•89 SECTION 9 — RESIDENTIAL POINT SYSTEM METHOD CLIMATE ZONES �'. DEPARTMENT OF COMMUNITY AFFAIRS CENTRAL 4 5 6 � BUILDER: PROJEC NAME AND AD ESS: _ PERMITTING CLIMATE 4 ❑ 5 ❑ 6�< OFFIC . ZONE: OWNER IIho�aw PERMIT ' JURISDICTION � o NO.: Ii I NEW CON TRUGTION ` IF MULTIFAMILY, NUMBER OF BY CONDITIONED FLOOR AREA ®FT SO. GLASS AREA AND TYPE ///❑��` UNITS COVERED THIS SUBMITTAL: �, CLEAR TINT,FILM,SOLAR SCREEN ADDITION PREDOMINANT EAVE OVERHANG mE SPANE ��FT SINGLE- FT., MULTIFAMI II ATTACHED ❑ CHECK IF THIS SUBMITTAL REPRESENTS A WORST CASE CONDITION: LENGTH PORCH m.❑ FT FT. DOUBLE- PANE PANE (gym FT. DOUBLE- ANE ❑�❑ FF SINGLE -FA ILY DETACHED ❑ NGTHOVERHANG _ u R NET WALL AREA AND INSULATION EXTERIOR!,MASONRY FT, R = J� M .� EXTERIOR FRAME F0. R = EXTERIOR STEEL R = ❑ EXTERIOR LOG R = m .n�� FT FT ADJACENT 'MASONRY ,R = ADJACENT FRAME R = ADJACENT STEEL R = ADJACENT LOG.. R =430. ,CEILING AREA AND -INSULATION FLOOR TYPE AND, INSULATION UNDER IATTIC,- r` R = SINGLE ASSEMBLY R = SLAB PERIMETER R = RAISED: 0 CON R = D s. � , M F ® F0. d FOT. ,u . FO. N—J-J FT DUCTS 1. _ COOLING' -SYSTEM HEATING SYSTEM HVAC CREDITS HOT WATER SYSTEM HOT WATER CREDITS IN UNCONIN ED C ENTRAL ELECTRIC STRIP El HEAT CEILING FANS ELECTRIC SOLAR: ❑ S.F. _ m SPACE R El Room El NATURAL GAS PUMP ❑ ❑ CROSS VENTILATION NATURALGAS , HEAT RECOVERY icHecKi ❑ 2001il ❑ PACKAGE TERMINAL OTHER ❑ ROOM UNIT OR FUELS ❑ WHOLE HOUSE FAN El OTHER FUELS DEDICATEDPTI IN .IJED AIR CONDITIONER PACKAGE TERMINAL HEAT PUMP ❑ NONE ❑ATTIC RADIANT El NONE HEAT PUMP: } � SPACE R Ir Ilil ElINONE ®, A�UEHSPFI BARRIER AMULTIZONE EF = ® E.F. NUMBER OF BEDROOMS, SEERIEER = . , = IN RATION PRACT CE USED /' O T C_ • X 1 OO = ❑ ❑$ TOTAL AS -BUILT POINTS TOTAL BASE -POINTS CA CU TED E 1. j rX2 CALCULATED ENERGY PERFORMANCE INDEX MUST NOT EXCEED 100 POINTS. In accordan 'e with S lion 553.907. 5.S.' I certify that the plans and specific Eions c ere t calcul n are n complian h the Florida Enei y Co Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed, this building will be inspected for compliance in accordance with Section 553.908 F.S. OWNI N\ ERIAG I ' BUILDING OFFICIAL: DATE: I DATE: 9A I PRES RIPTIVE MEASURES Must be met or exceeded by all residences.). - COMPONEN S SECTION I REQUIREMENTS CHECK WINDOWS 904.1 MAXIMUM OF 0.5 CFM PER LINEAR FOOT OF OPERABLE SASH CRACK. EXTERIOR & I ADJACENT DO RS 904.1 MAXIMUM OF 0.5 CFM PER SO. FT. OF DOOR AREA. INCLUDES SLIDING GLASS DOORS, SOLID CORE, WOOD PANEL INSULATED OR GLASS DOORS ONLY. EXTERIOR J01 TS CKS I & Cl 904.1 TO BE. CAULKED, GASKETED, WEATHERSTRIPPED OR OTHERWISE SEALED. WATER HEATE IS II 904.2 MUST BEAR LABEL INDICATING COMPLIANCE WITH ASHRAE STANDARD 90 OR COMPLY WITH EFFICIENCY AND STANDBY LOSS REQUIREMENTS. SWITCH OR CLEARLY MARKED CIRCUIT BREAKER (ELECTRIC), OR CUT-OFF GAS MUST BE PROVIDED. AN EXTERNAL OR BUILT-IN HEAT TRAP MUST BE PROVIDED. SWIMMING PO S & SPAS 904.3 SPAS & HEATED POOLS MUST HAVE COVERS (EXCEPT SOLAR HEATED). NON-COMMERCIAL POOLS MUST HAVE A -PUMP TIMER. GAS SPA & POOL HEATERS MUST HAVE MINIMUM THERMAL EFFICIENCY OF 75%. HOT WATER j PIPES 904.4 INSULATION IS REQUIRED ONLY FOR RECIRCULATING SYSTEMS INCLUDING HEAT RECOVERY UNITS. IN SUCH CASES, PIPING HEAT LOSS SHALL BE LIMITED TO 17.5 BTUMILINEAR FOOT OF PIPE, SHOWER HEAD 904.5 WATER FLOW MUST BE RESTRICTED TO NO MORE THAN 3 GALLONS PER MINUTE AT 80 PSIG. " HVAC DUCT jil CONSTRUCTIONII 903.2 904.E CONSTRUCTED IN ACCORDANCE WITH INDUSTRY STANDARDS & LOCAL MECHANICAL CODES. DUCTS IN 1 UNCONDITIONED SPACE MUST BE INSULATED TO MINIMUM R- 4.2 & JOINTS M T BE SEAL HVAC CONTROLS 904.7 1 SEPARATE READILY ACCESSIBLE MANUAL OR AUTOMATIC THERMOSTAT FOR EACH SYSTEM. INSULATION jil I 904.9 I CEILINGS —MIN. R-19. COMMON WALLS —FRAME R-11 OR CBS R-3. FRAME COMMON CEILINGS & FLOORS R-11. �i ll� 9-57 1P 19 1 MEADOWOOD-UNIT B-FT. PIERCE FLORIDA ENERGY EFFICIENCY CODE p {' FOR BUILDING CONSTRUCTION 1 ' ection 9 Compliance Program --Residential Point System Method Version 2.0 January, 1989 Department of Community Affairs tl Pr ntou.t generated by EPI89 and submitted in lieu of Form 900-A-89 TH S COMPL",IANCE FORM IS VALID IF SUBMITTED BEFORE JANUARY 1, 1990 -----------,------------------------------------------------------------------- PROJECT ------------- PERMITTING OFFICE: - AND ADDRESSli CLIMATE ZONE: 4 5 66 BUILDER: 9 PERMIT NO.: -- ---- ------------------- -------------- OWNER: it 4) JURISDICTION NO.:I��}/�---- -------------------------------------------------------------------{{-11--',---�L-��----- BUILDING OFFICIAL COMPO VALUE CHECKLIST STRUCTURE E: Singc�le- amily PREDOMINANTJEVE OVERHANG Length: 0.00 PORCH 0 G Length: 0.00 WINDOWS Single Ant Total Area: 626.0 WALLS 1. Ext Nori tBlock Int Area: 1578.0 P.-Value : 3.0 2. Ext Wood�Frame Area: 44.0 R-Value: 11.0 3.. Adj Wood' Frame Area: 324.0 R-Value: 11.0 DOORS 1: Ext Wood Area: 48.0 2. Ext Wood Area: 21.0 3. Ad' Wood, Area: 21.0 CEILINGS 1. FLAT finder Attic Area: 2508.0 R-Value : 30.0 FLO RS II 1. ISlab-on- rade Perim: 280.0 R-Value: 0.0 DUCTS Uncond. pace Length: ALL R-Value: 4.2 COOLING 1. Central /C SEER: 10.50 HEATING 1. Strip He 'It STRIP: 1.00 HOT WATER Multizone: Credit 4 Bedrooms: 3 1. Electric it EF: 0.88 (Dedicated Heat Pump EF: 3.00 INFILTRATION 11 11 Practice: 2 lConditioned Floor Area: 2508.0 4 it AS BUI,IiT POINTS / BASE POINTS =' 100 = EPI 45`01.5 46568.5 97.9 11 GLASS TO FLOOR AREA RATIO = 0.2496 1 xx P I CRIPTIVE MEASURES — -------------- � � (Must be met or exceeded by,all residences) =�----REQUIRII�IENTS ------ — - COMPONENTS I ------------------ SECTION ---------------- --------- WINDOWS l ----- 904.1 — ------------ --------------------- —Maximum of 0.5 C.E'�Ii per linear foot of operable ---------- - sash crack. EXTERIOR & ------------------------------------p 904.1 ---j ,- --------------------- Maximum of 0.5 CFM per sc. ft. of door a:rpa. ADJACENT DOORS Includes sliding glass doors, solid core, - wood panel, insulated, or glass doors only. - ------ EXT. JOINTS-------------------------------------------------------pp---------- & 904.1 To be caulked, casketed, weatherstri ed or CRACKS otherwise sealed. , ----------- WATER HEA -------------------- 904.2 ---------------------------- Must bear label indicating compliance w/ASHRAE i standard 90 or comply with efficiency and standby loss requirements. Switch or clearly marked circuit breaker (electric), or cut-off (gas) must be provided. An external or built in heat trap must be provided. ------------------------------------------------------------------------------ SWIMMING PO,LS 904.3 Spas and heated pools must have covers (except & SPAS solar heated). Non-commercial pools must have a pwnp timer. Gas spa & pool heaters must have minimum thermal efficiency of 75% -----------'------------------------------------------------------------------- HOT WATER 904.4 •Insulation is required only for recirculating PIPES systems. In such cases, gpaping heat loss shall be limited to 17.5 BTU/H/Linear Ft. of pipe. ------- - SHOWER HEAD ---------------------------------------------------------------- 904.5 Water flow must be restricted to no more than 3 - - -------------------- gallons per minute at 80 PSIG. ------ ------------------------------ HVAC DUCT 903.2 -------- Constructed in accordance with indust-- CONSTRUCTION 904.6 standards & local mechanical codes. Ducts in Unconditioned space must be insulated to '------------------------------------------------------------------- minimum R-4.2 & joints must be sealed. ----------- HVAC CONTRO S 904.7 Separate readily accessible manual or automatic --- ---- ------------------------------------------------------------------ thermostat for each system. INS'ULATION 904.9 Ceilings -Min R-19. l Common Walls - Frame R-11 or CBS R-3. Frame Coinnon Ceilings & Floors R-11. m INFILTRATION REDUCTION PRACTICE COMPLIANCE CHECILIST I COMPONENTS !II -....... -- CTICE #2, Exterior WaU.ls & Floors Exterior W. DuctWork. Fireplaces Exhaust Fa Combustion In iAccorda I Hereby a specificat lation are Florida En OWNER/ I DATE: is & Ceilings iances.. REQUIREM NTS Comply with Practice #1 and_ - thefollowing_ Top plate penetrations sealed. Infiltration barrier installed. Sole plate/floor joint caulked or sealed. Penetrations, Joints and cracks on interior surface caulked, sealed, and gasketed Ductwork in unconditioned space must be sealed. Equipped with outside combustion air, doors, and flue dampers. Equipped with dampers. Combustion devices see M3.2 ( f) . Provided with outside combustion air. with Sec. 553.907 F.S., .fy that the plans and covered by this calcu- c_om l iance w.Lth"Yhe z> ACT 4T Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section- 153.908 F.S. ,,BUILDING OFFICIAL: DATE: i� m 10 d� I :{::i::{. •l• •;: x::I::I::i::r• :: :i: a::{: v,::;::l::{::1: :=1::I::i::l- :1::;::1::1::l: x::;::l::I::i::1::;::;: a::;::1::1::k �::1::{::1::l: x :1::1: a: a: �::{::i: a::1: �::1::1: x: a: �::{::i::;::l::{::l::i: a::;::{::;::;: ::l::{: SUMMER CALCULATIONS • N... a... �.... .-.. �..;. ?. •1- .R :{: �::k �:J,: �::;: a:1::{o a:.y: a: a: 8::1::;::1::{::{::{::{::C :� :k :1::{: �::G a::1: �::{: ;1: %t::::1: a: y::g :{: ;1::{::{::,: : �::{rk::{::I: a::{::1::!::1:1: y::f::l: c{::{: BASE AS -BUILT ------------------------- ------------ ------------ GLASS=- ORIEN AREA ----- --=- �,Ix BSPM = POINTS TYPE ------=---- ------------------------- N 76.0� 47.8 3632.8 SGL T SGL T SGL T E 70.0 102.0 7140.0 SGL T SGL T SE 25.0104.1 2602.5 SGL T I SGL T S 315.0 90.9 28633.5 SGL T SW 72.0 1104.1 7495.2 I � 1102.0 6936.0 TNT INT INT TNT INT INT INT INT SGL TINT SGL TINT SGL TINT SGL TINT SGL TINT SGL TINT: SGL TINT SGL TINT SGL TINT SGL' TINT SGL TINT SGL TINT SGL 'TINT SGL TINT SGL TINT SC ORIEN AREA x SPM x SOF = POINTS -------------------------------------- N SW 72.0 1104.1 7495.2 I � 1102.0 6936.0 TNT INT INT TNT INT INT INT INT SGL TINT SGL TINT SGL TINT SGL TINT SGL TINT SGL TINT: SGL TINT SGL TINT SGL TINT SGL' TINT SGL TINT SGL TINT SGL 'TINT SGL TINT SGL TINT SC ORIEN AREA x SPM x SOF = POINTS -------------------------------------- N 36.0 51.5 0.93 1714.9 N 22.0 51.5 0.91 1026'.0 N 18.0 51.5 0.69 639.6 E 6.0 107.1 0.90 576.2 E 64.0 107.1 0.26 1782.1 SE 20.0 110.3 0.42 926.5 SE 5.0 110.3 0.22 121.3 S 15.0 98.3 0.88 1292.6 S 36.0 98.3 0.91 3220.3 S 36.0 98.3 0.89 3149.5 S 48.0 98.3 0.30 1419.0 S 96.0 98.3 0.39 3680.4 S 48.0 98.3 0.88 4167.9 S 12.0 98.3 0.25 294.9 S 24.0 98.3 0.25 589.8 SW 18.0 110.3 0.99 1962.2 SW 20.0 110.3 0.42 926.5 SW 24.0 110.3 0.42 1111.8 SW 5.0 110.3 0.22 121.3 SW 5.0 110.3 0.22 121.3 W 9.0 107.1 075 723.8 W 23.0 107.1 0:87 "2132.1 W 36.0 107.1 0.90 3457.2 ji .15.x CONDOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS. I GLASS AREA FACTOR POINTS POINTS POINTS .15-25081,10 626:0 0.601 56440.0 33916.1 --------35157_6 --- - ---------------------------------------------- - AREA -III BSPM = POINTS I TYPE ---------- - WALLS------- ----------------- 1-- Ext' 1622.0 � 1.00 1622.0 Adjl 324.0 0.70 226.8 DOORS------- 1-- Ext:. 69.0 it 4.80 331.2 Adj 21.0 1.60 33.6 CEILINGS -----'---- UA 2508.0 0.60 1504.8 FLOORS-------�-- Slb 280.0 '131.80 -8904.0 INFILTRATION-------- 2508.0 i10.90 27337.2 TOTAL SUMMERI POINTS r,cznc:zo , TOTAL x SUM PTS 56069.7 R-VALUE AREA .x SPM = POINTS Ext NormWtBlock Int 3.0 1578.0 1.40 2209.2 Ext Wood Frame 11.0 44.0 1.90 83.6 Adj Wood Frame 11.0 324.0 0.70 226.8 Ext Wood 48.0 7.20 345.6 Ext Wood 21.0 7.20 151.2 Adj Wood 21.0 2.40 50.4 Under Attic 30.0 2508.0 0.60 1504.8 Slab -on -Grade 0.0 280.0 -31.90 -8932.0 Practice #2 2508.0 10.90 27337.2 G n I n A A COOLING TOTAL x CAP x DUCT x SYSTEM x CREDIT = COOLING POINT'S COMPON RATIO MULT MULT MULT POINTS 0.43 24110.0 1 58134.4 1.000 1.140 0.320 1.000 21207.4 1 :;::;: x: y::;: -�• -�- �- •r •r •� ::;: a=-:;: : �::;:,:.y::;::;: a: ;;: a: ;;::;: a::;: ::::::::::::::: �::;::� :}: �: a: �::;::;: ;;::;::r• :;::;: a::;:::;= a::�: =r :;::;::;::;::;::;:::: �::;: a::;: 7::;::;; :;:::::;::;:.y::;::;::{::;: x: r WTIv'TER CALCULATIONS :�::;: �;: y::f: a• •;• -;::;: a• •�-, i1::;: a::;: �::;: a.:;::;::;::{::}::;::�::;: a: �:.y::;::r.:{::i::;::;::;:: a::;: a: �:::::::::::::::::;: ;;::{::,: �::;::;::;::;::�::{::;::;::;:::::;::;::;: : y: �::;::}::;::l::;: a: �: a::� :;: : : __- BASE '-== - __= AS -BUILT ORRIIEN--AREA,ix-BWPM----POINTS IL----- N 76.01 5.6 425.6 E 70.01, -5.6 -392.0 ' SE 1 25.0 -13.4 11 -•335.0 S 315.Od -14.0 -4410.0 SW 72.0 1-13.4 -964.8 W 68.011I -5.6 -380.8 TYPE SC ORIEN AREA x WPM x WOF = POINTS ------------------------- ------------------- SGL TINT N 36.0 9.6 1.04 359.4 SGL TINT N 22.0 9.6 1.05 222.5 SGL TINT N 18.0 9.6 1.20 207.4 SGL TINS' E 6.0 -2.0 .0.44 -5.3 SGL TINT E 64.0 -2.0 -5.04 645.1 SGL TINT SE 20.0 -9.7 0.05 -9.7 SGL TINT SE 5.0 -9.7 -1.01 49.0 SGL TINT S 15.0 -10.2 0.93 -141.5 SGL TINT S 36.0 -10.2 0.95 -348.8 SGL TINT S 36.0 -10.2 0.93 -343.3 SGL TINT S 48.0 -10.2 -0.83 408.7 SGL TINT S 96.0 -3.0.2 -0.13 '127.3 SGL TINT S 48.0 -10.2 0.93 -455.3 SGL TINT S 12.0 -10.2 -1.09 133.4 SGL TINT S 24.0 -10.2 -1.09 266.8 .SGL TINT SW 18.0 -9.7 0.99 -172.6 SGL TINT SW 20.0 -9.7 0.05 -9.7 SGL TINT SW 24.0 -9.7 0.05 -11.6 SGL TINT SW 5.0 -9.7 -1.01 49.0 -SGL TINT SW 5.0 -9.7 -1.01 49.0 SGL TINT W 9.0 -2.0 -0.36 6.5 SGL TINT. W 23.0 -2.0 0.27 -12:6 SGL TINT W 36.0 -2.0 0.44 -31.9 .15 x COND.ZOOR / TOTAL GLASS = ADJ. x GLASS = ADJ GLASS I GLASS AREA AREA FACTOR POINTS POINTS POINTS --�- J 1.� ?508.0 ----------- 1---------- ------------ 626.0 -------------------------------------------- 0.601-6057.0-3640.0 981.6 ----------------------=---=---__________=___ AREA BWPM = POINTS ----------------------------------------------------- I TYPE R-VALUE AREA. x WPM - POINTS ------------ WALLS-------'i--- ------------- Ext 1622.0 1.10 1784.2 Ext NormWtBlock Int 3.0 1578.0 3.80 5996.4 Ext Wood Frame 11.0 44.0 2.00 88.0 Adj 324.0 I 1.80 583.2 Adj Wood Frame 11.0 324.0 1.80 583.2 DOORS -------''--- Ext 69.0 5.10 351.9 Ext Wood 48.0 7.60 364.8 Ext Wood 21.0 7.60 159.6 Adj 21.0 III. 4.00 84.0 Adj Wood 21.0 5.90 123.9 CEILINGS- ---''17---- UA 2508.0 0.60 1504.8 Under Attic 30.0 2508.0 0.60 1504.8 FLOORS------ --- Slb 280.0 -1.90 -532.0 Slab -on -Grade 0.0 280.0 2.50 700.0 INFILTRATION -------- 2508.0 1 4.10 10282.8 Practice #2 2508.0 4.10 10282.8 TOTAL WINTER, WINTER - POINTS 10418.9 } 20785.1 ` -------- =----------------- TOTAL x SYS EM = HEATING I TOTAL x CAP x DUCT x SYSTEM x CREDIT = HEATING WIN !PTS T POINTS COMPON RATIO MULT MULT MULT POINTS ---------- 1041i8.9 - --; - ------------------------- --- ----------- - --- - ------------ ---- ---- 21325.E ---1 r-===='1877_5--20785_1--1_000-1_140- -1_000----0_900--_ 45 :1; :1., 1. ;j: 4. .1: :.,: *:I: WATER HEATING BASE AS -BUILT --------- — ---------- NUhl OF T TOTAL TANK VOLUME EF TANK x MULT x CREDIT TOTAL BEDR,4S RATIO MULT --------- ------- 2 --------------------------------------- 3 3 7.0 10581.0 so 0.88 1.000 35227.0 0.29 3068.5 � SUMMARY BASE AS -BUILT ------------------- ------------------------------------------------ COOLING dEATTNG HOT WATER TOTAL I COOLING HEATING ' HOT WATER TOTAL POINTS + qOINTS + poj,,TTS = POINTS POINTS + POINTS +.-POINTS = POINTS ----- --------------- --------------------------------------- 24110.0 1-l77.5 10581.0 46568.5 21207.4 21325.6 3068.5 45601.5 F8 EPI = 97.9