Loading...
HomeMy WebLinkAboutFIELD DENSITY TEST REPORTArdaman & Associates, �NT� copy- PortP.O. Box 8687 St. Lucie, FL 34952 i� (407) 337-1200 FIELD DENSITY TEST REPORT PROJEC ' : 2545 Jernigan Road FILE NO.: 89-5596 Lots 13,14,15, & 16 Block D REPORT NO.: 7 REPOR D TO: Panorama Homes PAGE NO.: 1•. OF 1 ' l DATE: December 6, 1989 TEST LOCATION TEST MDR. DRY DENSITY MOISTURE DEPTH/ PERCENT NO. DATE NO. (PCF)° ELEVATION COMPACTION 1 outh Wall Near Wall 11-30-89 1 111.1 8.5 0 to -1 94.6 # 2 renter of Building Pad 11-30-89• 1 110.0 8.2 0 to -1 93.6 3 enter of Buildin'•Pad 11-30-89 1 107.7 9.1 -1 to -2 91.7 I 4 �orth Wall Near Wall-.j-: = 11-30-89 1 110.3 8.8 0 to -1 93.9 5 6test of #1 I 12-05-89 1 112.0 8.0 0 to -1 95.3 6 Retest of #2 12-05-89 1 112.1 8.8 0 to -1 95.4 7 ��etest of #3 12-05-89 1 112.4 9.0 -1 to -2 95.7 8 6etest of #4 12-05-89 _lT 112.3 8.2 0 to -1 95.6 FIELD T ST: ASTM D2937 ❑. D2922 [f D2167 ❑ D1556 ❑ 'Area does not meet project MINIMU COMPACTION REQUIRED: 95 PERCENT requirement of 95% compaction LAB P RATORY MOISTURE — DENSITY RELATIONSHIPS MSl -MEAN SEA LEVEL FS =FLOOR SLAB $uBGRADE MDR NO. TEST METMOD MAXIMUM DENSITY @ OPTIMUM MOISTURE M - MEANLIMERSEA BASE FS .- GRADE 1 I ASTM D-1557 117.5 PCF C 9.8% SG = STABILIZED SUBGRADE NG = NATURAL GROUND I PCF C % FFG - FINISH FLOOR GRADE PR - PENETROMETER READING 11 PCFC % SOF . BOTTOM OF FOUNDATION PD = PROBE DEPTH By •S A M1';1V1" PR ' ECTION TO CLIENTS THE PUBLIC AND OURSELVES ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY Of W- CLIENTS ANO AUTMORkION :)A PUB.ICATID� OF STATEMENTS CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN ArPROVA. I