HomeMy WebLinkAboutMOISTURE-DENSITY RELATIONSHIPMANm � Ardaman & Associates, Inc.
f 0811iVwl�%
P. 0. Box 8687
Port St. Lucie, Florida 34985
(407) 337-1200 B . P . #50940
-;; MOISTURE -
DENSITY RELATIONSHIP
P' OJECT' 2545 Jernigan Road
FILE NO.: 89-5596 Report #7
Lots 13,14,15 & 16 Block
D
R PORTEDTO: panorama Homes
DATE: December 6, 1989
SUMMARY OF TEST RESULTS
SAMPLE NO.
SAMPLED BY
E.C.
SAMPLE LOCATION
On Site
120
TEST METHOD
ASTM D-1557
MAXIMUM DRY
DENSITY PCF
117.5
OPTIMUM WATER
CONTENT %
9.8
115
UNIFIED SOIL
CLASSIFICATION
SC
SOIL DESCRIPTION:
Brown Clayey Fine Sand..
110
ENEENNEENNEMEMNLL FOR SPECIFIC GRAVITY
11MMEMENNEENEEMENNOL, EQUAL TO
EMENNENNNEEMENE ONE
mmmmmmmmmmmmmmmi
851 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1. 1 1 I I I IN
5 10 15 20 25 30 35
WATER CONTENT — PERCENT OF DRY WEIGHT
FORM (Rev.4/86)
By t
AS A MU PAL PROTECTION TO CLIENTS THE PUBLIC AND OURSELVES. ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS ANC AUTHOPi-
ZATION QR PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL