HomeMy WebLinkAboutWORKSHEET1 I •%. / III �/�'
_WORKSHEET
Elf A'AIPAPFa
COMPONENTS
JI,
COMPLIANCE
TO BE INSTALLED • M
B Ifs
PACKAGE:
9
EXTERIOR WALL• II..:•
•
R � %:..• ..
"' 'ae e�'uyra�'Nuy.
IN ;I
' _
WOOD FRAME: R = _!�
MASONRY: R =
LI
CEILING INSULATION -'
p 9..
•�
='
R =
SLAB- R =
FLOOR TYPE
RW: R =
S'AB: R = 0
RAISED WOOD: R =
RAISED CONCRETE: R =
RC: R o
FOR RENOVATIONS ONL
PERC�NT OF
'//
15
CONDITIONED'
TOTAL GLASS AREA SO, FT.
FLOORIAREA20%:
COND, FLOOR AREA = C SO. FT. _ ._, x 100 -
GLAS
SC: ST:
SINGLE CLEAR (SC): _� SINGLE TINT (ST):
i'IYPE
DC:
DOUBLE CLEAR DC : DOUBLE TINT D :
•:
OVERII
ANG • , .
r�
WIDTH = � _6L FT.
OPTION 1
OPTION 2
.;•;
,.,
(Selec.l'Ione)
:..:
FOR GLASS ON GABLED ENDS
AREA OF GLASS WITHIN 61/1 FEET
X .0225
OF PRESCRIBED OVERHANG' _
z
COND. FL AREA. MAX. SO. FT.
TOTAL AREA OF GLASS =
O
it
AR'_A OF GLASS
ON GABLED ENDS - SO. FT.
AMA OF ACTUAL GLASS ON GABLED .
0
/ so. Fr
N
ENDS MUST NOT EXCEED 2.2s46 OF
CONDITIONED
0 ED FLOOR AREA.
SO. FT.
G
R
C7
—AND—
FOR GLASS ON NON- GABLED ENDS
X 100
.
TOTAL LINEAR FEET OF GLASS MORE
THAN 61h FEET BELOW PRESCRIBED
•
OVERHANG =
FEET
MUST BE EQUAL TO OR GRE4TER THAN 80%.
TOTAL LINEAR FEET OF CLASS MORE
THAN 64 FEET BELOW PRESCRIBED
O' 'ERHANG MUST NOT EXCEED 14 FT,
DUCTS
COND. ' y/—
UNCOND, R=x D
_ IN. CONDITIONED SPACE: yes �._ no R 75
SPACE COOLING
SYSTEM
SEER = _ 7• R
SEER
STR:
ELECTRIC STRIP (STR)
SPACE. HEATI G
SYSTEM
COP =
HEAT PUMP (HP): COP = _ a .
NATURAL GAS (NG): AFUE =
NG: AFUE =
P,.HP: COP =
l
OP: AFUE =
SOLAR: S.F. = NONE
0
R
OTHER FUELS (OF): AFUE _
Mh
AN
AND
AND
ELECTRIC
=
ELECTRIC RESISTANCE: EFEF
WATER HEAT NG
SYSTEM
HEAT RECOVERY
NATURAL GAS (NO): EF =
AWH
DEDICATED HEAT PUMP: EF -
";..,
=:
NG: EF : ' '
SOLAR: SF • —(MIN. .40)
OTHER FUELS (OF): EF -
.;rp _"'`:•'•
OF: EF ='.
NATURAL.GAS: EF =
OTHER REQUIREMENTS.;'
:'NONE:.::,. •�
i
CFICV
NCNE CEILING FANS (CF): INSTALLED CROSS VENTILATION (CV):
GENERALID RECTIONS
1. Choose'oi
tion incluc
Items acts
2. On the we
3: Fill in the
these req
4. On the we
must be 4
5. Complete
6. Read "MI
7. Read, sig
of the component'packages from page 2 by which'you intend to comply with the code. Packages "A" through "0" are for new constru
g`additions to. existing residences. Packages "P" and "Q" are for residential renovations only. For renovations, only the energy-relatr
ly being renovated must meet the prescriptive requirements.
sheet above, fill in the blank "Compliance Package: " with the component package letter ("A" through "Q") you have chose
aces dnd�r the heading "Compliance Package: " with the component requirements for the package you have chosen. Co;
ements from -the charts on page 2,
sheet above fill in all the applicable sF; ces in the "To Be Installed" column with the Information requested. All "To Be Installed" valu,
tat to or better than the required IovcT;,
9 information requested on the top half of page 1 based on the workshoot information.
num Requirements for All Packages' :•, Tablo,10A on page 1 and check to Indicate your intention to comply with all applicable iten-
and date the "Owner/Agent" certifics?ion statement at the bottom of page 1.
q*