HomeMy WebLinkAboutBLOWER DOOR TEST FORMPlanning & Development Services Building & Code Regulation Division SCANNED 2300 Virginia Ave, Rm 201 BY Fort Pierce, FL 34982 St, Lucie C al Phone:772-462-2165 Fax:772-462-6443 I go a"D11? RECEIVED BLOWER DOOR TEST FORlifll SEP272' li House Infiltration Test Certification LST.ucie County, Permitting Prescriptive and Performance Method I Datef g Permit #: g o < < Contract' r: ::)—C_ Job Add ss: g 2 9 S S'g ,'� e. l� �rl, '� e Constru ion: New Construction — Complete 1-f- f+ L.&Iry C, . Ft_ 31+19s 2 ( ) Existing — ktetr Addition House Ini�'Itratlon Test Results SLC Climate Zone 2 CFM (50) 4 1 3.3 2 Test Date: Volume �I `Z- .( 1 0 $ - ACH (50) CFM (50) x 60 / Volume Mechanical Ventilation required less than 3 ACH i Passing results must be & ACH (50) or less (0 Pass ( ) Fail i FBC, Ener; The buildi hour in Cl blower do Section 5! approved provided thermal e, FRC, Reside Where the i pressure of i the dwellir Testing Coi � Company t 1 hereby cer requirement I Signature: _ i i Printed Nan License/Cerl or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per ate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in 993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an ird party. A written report of the results of the test shall be signed by the party conducting the test and the code official. Testing shall be performed at any time after creation of all penetrations of the building teal . r infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a .2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. e: Pro -Duct Services Address: 1915 Rio Vista Drive, Ft. Pierce, FL 34949 y that the above House Infiltration results demonstrate compliance with FBC Energy Conservation in accordance with Section R402.4.1.2 Climate Zone 2. . Martin Klein #: 5061633 1 BUILDING PERFORMANCE INSTITUTE, INC. 107 Hermes Road, Suite 210 Malta, NY 12020 (877) 274-1274 www.bpi.orgMartin Wein BPi 00:5061633 SM (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) CERTIFIED PROFESSIONAL DESIGNATION EXPIRATION DATE Infiltration & Duct Leakage (IDL) 4/262021 BUILDING PERFORMANCE INS