HomeMy WebLinkAboutTRUSS DRAWING=LIFE SAFETY WARNING
HIP VALLEYS ARE DIFFICULT TO INSTALL, PROBLEMS CAN BE ADDRESSED BY CUTTING HIP VALLEYS IN HALF & FINDING CORRECT LOCATION
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT I/
This symbo Identifies Life Safety Warnings that
should be r ad and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
,. TO DETERMINE IF MULTIPLE PLY. A
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Soin or less
60 degrees
orless
♦ram 112 s an �, Tag �prox 2/3 to
Tag line approx 9 line 1/2 of Span.
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane is used. Truss must be set this way if crane is used.
Truss is an example, your truss may not match. Truss is an example, your truss may not match.
Insist crane operator sets truss this way. I Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
A are installed. A
•
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
-equirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
!\ WARNING 0,
The size of these trusses makes it necessary that they e set by a profeesional builder
3miliar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
1 wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
Hatch Legend
Q yCEILING @ 101
2.5/12 VAULT
BRG WALL @ 91- 411
BRG WALL @ 111- 8111
OCONNECTIONS DESIGNED
AND SUPPLIED BY OTHERS
JOTES:
INTERNAL LOAD BEARING WALLS REQUIRED BY TRUSSES AS SHOWN ON THIS LAY
ALL BEAMS BY OTHERS.
TRUSS TO LEDGER CONNECTIONS DESIGNED AND SUPPLIED BY OTHERS.
BUILDER IS TO BALANCE FRAME CEILINGS AS NEEDED.
d Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers II
,L.
II
CORNOERJACKS
ARE NOT BEVELED.
SEE STANDARD
NGINEERING.
24''O C. THRU
t1l
CORNERJACKS
ONLY 24'
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
Z)UUAKt UU I tNU
2X4 TOP CHORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
V \,.D V/ll\L VV 1 LIrV
2X4 TOP CHORD
WALL HEIGHT 9'-4"
END DETAIL: COFFER
i
I
r� 2.5
4-01
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 9'4"
END DETAIL: (A)
5It-
6-11=G I 1
N
FABRICATION AGREEAIIENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this buss placement diagram layout, which is the sole authority for
etermining successful fabrication of the busses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days W delivery the
ldersigned agrees that no backcharges will be allowed. In the event such written notice is famished Chambers Truss
fall have three (3) business days in which to begin repairs required, or to substitute other busses, at Chambers option,
her 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of "BCSI` summary sheet by TPI & WTCA-
5. Delivery is to job site. It Is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
responsible for dump delivery only. The buyer is responsible for additional delivery expenses ff Chambers Truss has
redeliver because job site is not prepared for delivery a buyer is not prepared for delivery of busses. Buyer is
sponslble to Chambers Truss for lowing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change it any charges are made in this layout A $50 per hour
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to. or if no agreement a reasonable price.
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date d
:livery 'd buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
asonable attorneys fee for collections in event of payment not timely made. 1-10 % per month service charge will be
Wed for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
iyment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
ndersigned agrees to pay such indebtedness including attorneys tees, d default in payment for material be made by the
dpient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
erein, the parties agree that the sole venue for any such action will be Saint Luce County, Florida.
11. Design responsibilities are per `"'National Standard And Recommended Guidelines On Resporsdn2ities For
onstruction Using Metal Plate Connected Wood Trusses ANSI/TPUWTCA 4 - 2002'"'
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per'BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary
po ry and permanent bracing are required and can save I'rfe and property
and is the responsibility of the truss erector.
.111161
Study the contents of the information packet included on delivery before
setting trusses.
.1111161111,
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
®
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
3105 Oleander Avenue
Fort Pierce, Florida 34982.6423
800-551.5932
Fort Pierce 772-465-2012 Fax 772465.8711
Vero Beach 772-569-2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
PLUMB CUT END
_.—,--.._.-.. .. _..._
—
LOADINGrOESIGN CRITERIA REDUCIBLE
2X4 TOP CHORD
DESIGN
PER CODE SUCH AS SW I&M 5.1
LEDGER BOTTOM @ 10'
END DETAIL: (B)
county
Saint Lucie County
Building Department
City of Port Saint Lucie
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 0
Top Chord Dead
7 42 0
Bottom Chord Live
-10-Non Conccurent 0
Bottom Chord Dead
10 3 0
Total Load
47 7.2 0
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
16,
Building Type
Enclosed
Building Category
It: Non Restrictive
Exposure Category
C>Open Terrain with scattered obstructions
Miles from Ocean
5
Conforms to Florida Building Code 2017
R.D.L.=Restraining Dead Load
C.B.=Continuous Bracing
PAUL WELCH INC.
MECH-ELECT-CIVIL ENk_,,
1984 BILTMORE ST. #114
PORT SAINT LUCIE, FL
PAUL WELCH P.E
FLA REG NO.29945
r
4(k I 204
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75217
SCALE: 1 /4" = 1 D-0r1
145 total trusses, 47 unique designs
Designer: BLW Reviewed by: _
Date: 06/04/18
FOR
JC & Sons
DESCRIPTION: t—ILE Copy
NGUYEN I
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
75217