HomeMy WebLinkAboutNOA-ASPHALT SHINGLESDEPARTMENT OF
BOARD AND CODI
i
NOTICE OF
Iko Industries L.
40 Hansen Rd. S
Brampton, Onta
L6W3H4
I
SCOPE:
This INOA is bein
documentation su
used; in Miami-D,
This NOA shall i
(in I Iiaini-Dade
or material testes
manufacturer wi.
of s>I ch product c
determined by IV
of the applicable
This product is a
including the Hil
Dt'SCRIPT101
LABELING: E
stafement: "Miai
I I
RE' NEWAL oill
in t'he applicable
TERMINATI
materials, use, a
sales, advertisinl
thiL NOA shall I`
ADVERTISE
by the expirat
it 'shall be don,
INSPECTIOl�
shall be availab
Tl is NOA rene'
The submitted
I id
.l0 1C05
TORY AND ECONOMIC RESOURCES (RER)
STRATION DIVISION
kCCEPTANC-E (NO
AUG 0 3 2018
o CANADA
ST. Lucie County, Permitting
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
rvww.miamidade.goy/economy
I issued under the applicable rules and regulations governing the use of construction materials. The
onitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
Je County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
)t be valid after the expiration date stated below. The Miami -Dade County Product Control Section
ounty) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
'or quality assurance purposes. If this product or material fails to perform in the accepted manner, the
incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
tmi-Dade County Product Control Section that this product or material fails to meet the requirements
uilding code.
)roved as described herein, and has been designed to comply with the Florida Building Code
i Velocity Hurricane Zone of the Florida Building Code.
: Cambridge, Cambridge HD, and Biltmore AR Asphalt Shingles
;h unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
-Dade County Product Control Approved", unless otherwise noted herein.
is NOA shall be considered after a renewal application has been filed and there has been no change
gilding code negatively affecting the performance of this product.
N of this NOA will occur after the expiration date or if there has been a revision or change in the
d/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
cause for termination and removal of NOA.
ENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
n date may be displayed in advertising literature. If any portion of the NOA is displayed, then
in its entirety.
A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
e for inspection at the job site at the request of the Building Official.
NOA No.14-0603.02 and consists of pages 1 through 4.
umentation was reviewed by Gaspar J Rodriguez.
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Pagel of 4
I
ij
I
I I.
ROOFING ASSE, BLY APPROVAL
i II
Categ'ory: Roofing
Sub -Category: Asphalt Shingles
Materials: Laminate
Deck !Type: Wood
SCOPE
�I
This approves a rl' Cing system using Cambridge AR, Cambridge HD, and Biltmore AR asphalt shingles
man>I factured by 0 Industries Ltd. as described in Section 2 of his Notice of Acceptance.
PRODUCT DES RIPTION
Prod ct Dimensions Test Specifications Product Description
Cambridge ��i 13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced
Man I facluring L ation W, 2, 3 laminate asphalt shingle.
Ca (bridge HD I' 13 3/4" x 40'/8" TAS 110 A heavy weight; fiberglass reinforced
l factW-ing L! cation #l, 2, 3 laminate asphalt shingle.
Man
I II
Biltmore AR 13 3/4" x 40'/8" TAS 110 A heavy weight, fiberglass reinforced
Manyact w ing L�' anon #1, 2 laminate asphalt shingle.
M I UFACTU' 1NG LOCATION
1. I Kankakeej L
2. Wilmington , DE
3. Sylacuaga;,AL
EVIDENCE S BMITTED
Test I' enc Test Identifier Test Name/Report
PRI Constructioi Materials Inc. IKO-050-02-01 TAS 100
Approvals
IKO-076-02-01
IKO-114-02-01
IKO-099-02-01
IKO-096-02-01
IKO-095-02-01
IKO-121-02-01
IKO-100-02-01
IKO- 115-02-01
3041689
3036971
3042673
TAS 100
TAS 100
TAS 100
ASTM D 3462
ASTM D 3462
ASTM D 3462
ASTM D 3161 (TAS-107)
ASTM D 3161 (TAS-107)
ASTM D 3462
ASTM D 3161 (TAS-107)
ASTM E 108
Date
12/21/09
02/21/12
09/25/ 14
05/12/14
09/27/ 13
09/27/ 13
09/25/14
05/21/14
09/25/ 14
02/23/11
01 /04/09
04/12/11
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 2 of 4
! I�
I'
LIMITATIONS j
1! Fire classil ication is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratingsof this product.
21. Shall not > installed on roof mean heights in excess of 33 ft.
31. All produ s listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G 0-3 of the Florida Administrative Code.
li
I
INSTALLATION
1. Shingles „call be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing call be in accordance with Roofing Application Standard RAS 115
3. The man li acturer shall provide clearly written application instructions.
4. Exposure, nd course layout shall be in compliance with Detail W, attached.
5�. Nailing s all be in compliance with Detail U, attached.
I�
I
LABELING j
j1. Shingles] hall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product ontrol Approved".
I
l QbDADE COUNTY
I'
BUILDING PE' MIT REQUIREMENTS
1. Applica 'on for building permit shall be accompanied by copies of the following:
1.1 1j, is Notice of Acceptance,
1.2 iy other documents required by the Building Official or the applicable code in order to properly
Ialuate the installation of this system.
I s�
ii
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 3 of 4
I
DETAIL A
I
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR COURSE LAYOUT
I I
------------
I II
'I
F- — -- — 24" -
14! -
i
it
i
i
I�- 4 _.
FIRST (BOURSE
OF ROOF
Note: Roofing Cement not shown in this layout.
This drawing is for course layout only. See Detail B
for nailing and cement placement details.
THIRD COURSE
SECOND COURSE
I
I
DETAIL B
CAMBRIDGE, CAMBRIDGE HD, BILTMORE AR
40 7"
a
END OF THis ACCEPTANCE
1"
5 8" EXPOSURE
NOA No.: 16-0329.13
Expiration Date: 05/05/21
Approval Date: 04/21/16
Page 4 of 4