Loading...
HomeMy WebLinkAboutWIND UPLIFT RESISTANCEBY no TRINITY ER® APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND -UPLIFT RESISTANCE ` Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 6-9 1B Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation,. Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13-14 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 15-16 F Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 1 6o New Reroof (Tear -Off) or Reeover E Non--�nsulatetl Mee'. A ac a BasetS eet. Bonded Roof Cover. 0- 3 2A Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 23-24 2B Steel or Structural Concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 25-27 2C Steel or Structural Concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 28-30 3A Structural Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 31-39 3B Structural Concrete New -or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 39 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 40-41 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 42 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 43-45 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 46 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 47 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 48 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 48 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 48 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 49-51 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 52 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 52 61) Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 52 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 53-57 Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report P40690.12.13-1-R6 for FL16717-RS Certificate of Authorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION Revision 6: 09/12/2017 °repaLedbv Robert Nieminen P-F 59166 Ro(yglassModifiedBTtum_en Roof Systems, (570) 384-1230 Appendix 1 Page 1 of 57 F)o \JTRINITYI ERD TABLE 1G: WOOD DECKS =NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasten Attach Base Ply Cap (Psf) No BASE PLY: Elastobase, Elastobase P, Polyglass G2 Base, OMG Flat Bottom Plates (square) with Roofgrip #14, W-98. Min. 19/32- CertainTeed Glasbase, Dekfast Hex (aka, Dekfast with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two None SBS-AA, SBS-TA, APP- 52.5 inch plywood Firestone MB Base, JM with or Trufast 3" Metal Insulation Plate with Trufast HD ionPLTPlate (2), equally spaced, staggered center rows TA Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 W 99 Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two None SBS-AA, SBS-TA, APP- _60.0 inch plywood (2), equally spaced, staggered center rows TA Dekfast Hex (aka; Dekfast PLT-H-2-7/8) with Dekfast #14, Min. 15/32- Polyglass G2 Base, OMG 3" Round Metal Plate with OMG HD, OMG Flat 10-inch o.c. in 4-inch lap and 10-inch o.c. in three SBS-AA, SBS-TA, APP- W-100. inch plywood Elastobase, Elastobase P Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" (3), equally spaced, staggered center rows None TA 75.0 Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, Min. 15/32- OMG 3" Round Metal Plate with OMG HD, OMG Flat 10-inch o.c. in 4-inch lap and 10-inch o.c. in three W-101. inch plywood Polyglass APP Base Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" (3), equally spaced, staggered center rows None APP-TA -75.0 Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, Min. 15/32- Polyglass G2 Base, OMG 3" Round Metal Plate with OMG HD, OMG Flat 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), SBS-AA, SBS-TA, APP- W-102. inch plywood Elastobase, Elastobase P Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" equally spaced, staggered center rows None TA -90.0 Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, Min. 15/32- OMG 3" Round Metal Plate with OMG HD, OMG Flat 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), W-103. inch plywood Polyglass APP Base Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" equally spaced, staggered center rows None APP-TA -90.0 Metal Insulation Plate with Trufast HD. Min. 15/32- Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), W-104. inch plywood Elastobase, Elastobase P Insulation Plates equally spaced, staggered center rows None SBS-AA 90.0 Min. OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), SBS-AA, SBS-TA or W-105. inch pllywoo plywood Elastobase, Elastobase P OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally spaced, staggered center rows None APP-TA -90.0 Plates Min. 2- OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with o.c. at 4-inch lap and 6-inch o.c. in three (3), W-106. inch plywood l w Polyglass APP Base OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally equally spaced, staggered center rows None APP TA -90.0 Plates W-107. Min. 1S/32- Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal. 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), None SBS-AA -120.0 inch plywood Insulation Plates equally spaced, staggered center rows Min. OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with o.c. at 4-inch lap and 6-inch o.c. in five (5), SBS-AA, SBS-TA or W-108. inch plywood plywood Elastobase, Elastobase P OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally equally spaced, staggered center rows None APP TA -120.0 Plates Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P40690.12.13-1-R6 for FL16717-RS Certificate of Authorization #9503 6T" EDITION (2017) FBC HVHZ EVALUATION Revision 6: 09/12/2017 Pfeoaredbv Robert-Nierninen,. PE59166 Polyglass Modified Bitumen Roof Systems (570) 384-1230 Appendix 1 Page 20 of 57 �0 TRINI7Y1E►tD TABLE 1G: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 15) MOP No. Deck (Note 1) Type Fasten Attach Base Ply Cap (psf) Min. OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with o.c. in five (5), 6-inch o.c. at 4-inch lap and 6-ter W-109. inch plywood plywood Polyglass APP Base OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally spaced, staggered center rows r None APP-TA -120.0 Plates ASPHALT -APPLIED ORTORCH-APPLIEDBASE .PLY: Elastobase, Elastobase P, Polyglass G2 Base, OMG Flat Bottom Plates (square) with Roofgrip #14, W-130. Min. 19/32- CertainTeed Glasbase, Dekfast Hex (aka, Dekfast with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, SBS- 52.5 inch plywood Firestone MB Base, JM or Trufast 3" Metal Insulation Plate with Trufast HD ionPILTPlate with (2), equally spaced, staggered center rows TA, APP-TA AA, SBS-TA, APP TA Perma-Ply 28, Tamko Glass Base or GAFGLAS #75 W-111. Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, SBS- -60.0 inch plywood (2), equally spaced, staggered center rows TA, APP-TA AA, SBS-TA, APP-TA Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, W-112. Min. 15/32- Polyglass G2 Base, OMG 3" Round Metal Plate with OMG HD, OMG Flat 10-inch o.c. in 4-inch lap and 10-inch c.c. in three BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, SBS- inch plywood Elastobase, Elastobase P Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" (3), equally spaced, staggered center rows TA, APP-TA AA, SBS-TA, APP-TA 75.0 Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, W-113. Min. 15/32- Polyglass APP Base OMG 3" Round Metal Plate with OMG HD, OMG Flat 10-inch o.c. in 4-inch lap and 10-inch o.c. in three APP TA APP-TA -75.0 inch plywood Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" (3), equally spaced, staggered center rows Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, W-114. Min. 15/32- Polyglass G2 Base, OMG 3" Round Metal Plate with OMG HD, OMG Flat 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, SBS- inch plywood Elastobase, Elastobase P Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" equally spaced, staggered center rows TA, APP-TA AA, SBS TA, APP-TA -90.0 Metal Insulation Plate with Trufast HD. Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14, W-115. Min. 15/32- Polyglass APP Base OMG 3" Round Metal Plate with OMG HD, OMG Flat 9-inch o.c. in 4-inch lap and 9-inch o.c. in four (4), APP TA APP-TA -90.0 inch plywood Bottom Plate (Accutrac) with Roofgrip #14 or Trufast 3" equally spaced, staggered center rows Metal Insulation Plate with Trufast HD. W-116. Min. 15/32- Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), BP -AA or SBS-AA SBS-AA -90.0 inch plywood Insulation Plates equally spaced, staggered center rows Min. 1ywoo OMG #12 Standard Roofgrip or OMG #14 Heavy Duty o.c. in three (3), o.c. at 4-inch lap and 6-ter BP -AA, SBS-AA, SBS- SBS- W-117. inch plywood Elastobase, Elastobase P (min. 1-5/8-inch long) with OMG 3" Round Metal Plates or equally equally spaced, staggered center rows r TA, APP-TA TA, AP, AA, SBSBS-SAS-TA, AA, SBS-TA, APP-TA -90.0 OMG Flat Bottom Metal Plates Min. OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with 6-inch o.c. at 4-inch lap and 6-inch o.c. in three (3), W-118. inch plywood plywood Polyglass APP Base OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally spaced, staggered center rows APP-TA APP-TA -90.0 Plates W-119. Min. 15/32- Elastobase, Elastobase P Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), BP -AA or SBS-AA SBS-AA -120.0 inch plywood Insulation Plates equally spaced, staggered center rows Exterior Research and Design, U.C. d/b/a Trinity ) ERD Evaluation Report P40690.12.13-1-R6 for FL16717-RS Certificate of Authorization #9503 6' EDITION (2017) FBC HVHZ EVALUATION Revision 6: 09/12/2017 P-reoared-by-RobetLNieminen, PE-59166 Polyglass Modified Bitumen Roof Systems; (570) 384-1230 Appendix 1 Page 21 of 57 , .• Q0 I RINITi I ERD TABLE 3G: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (SCREWS & PLATES), BONDED ROOF COVER System Base Sheet Roof Cover (Note 1S) MDP No. Deck (Note 1) Type Fasten Attach Base Ply Cap (Psf) Min. 15/32- OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with 6-inch o.c. at 4-inch lap and 6-inch o.c. in five (5), BP -AA, SBS-AA, SBS- SBS-SA, APP-SA, SBS- W-120. inch plywood Elastobase, Elastobase P OMG 3" Round Metal Plates or OMG Flat Bottom Metal equally spaced, staggered center rows TA, APP-TA AA, SBS TA, APP TA -120.0 Plates Min. OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with inch o.c. at 4-inch lap and o.c. in five (5), W-121. l w2- inch plywood Polyglass APP Base OMG 3" Round Metal Plates or OMG Flat Bottom Metal a enter r equally spaced, staggered center rows APP TA APP-TA -120.0 Plates SELF -ADHERING BASE PLY:" Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two SBS-SA, APP-SA, SBS- W 122. inch plywood (poly -film top) orTrufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows SBS-SA TA, APP-TA _52.5* Min. 19/32- Elastobase, Elastobase P Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast #14 12-inch o.c. in 4-inch lap and 12-inch o.c. in two W-123. inch plywood (poly -film top) orTrufast 3" Metal Insulation Plate with Trufast HD (2), equally spaced, staggered center rows Polyflex SA Base APP-TA -52.5* W-124. Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two SBS-SA SBS-SA, APP-SA, SBS- 60.0* inch plywood (poly -film top) (2), equally spaced, staggered center rows TA, APP-TA W-125. Min. 19/32- Elastobase, Elastobase P OMG Flat Bottom Plates (square) with Roofgrip #12 12-inch o.c. in 4-inch lap and 12-inch o.c. in two Polyflex SA Base APP-TA -60.0* inch plywood (poly -film top) 1 1 (2), equally spaced, staggered center rows Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P40690.12.13-1-R6 for FL16717-RS Certificate of Authorization #9503 GP EDITION (2017) FBC HVHZ EVALUATION Revision 6: 09/12/2017 vrPpamd-hv=Rehert-Nieminen. R€-59-16Fi Polyglass_6Bodifled Bitumen Roof Systems; (570) 384-1230 Appendix 1 Page 22 of 57