Field Density Tests iiif Compacted Soils Method D-6938
Proje
t: Proposed Residence Lot.11, Creekside
Date:
October 5, 2018
Addr
ss: 3142 Tidewater Circle; Fort Pierce, FL
Order #:
18DR886
Area
I ested: Building Pad
Permit #:
�Q r� - DU3 7 .
Mate
jal Type: Pale Brown Sand with Traces of Shell
Tech:
BK
Clien
D:R. Horton, Inc.
Addr
ss: 1430 Culver Drive NE
Compaction Req.:
95%
Palm Bay, FL 32907
Proctor Method:
ASTM D-1557
Test
#
TEST LOCATION
Probe
Depth
Elev.
Moist
%
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
%
Compaction
Pass
1
I enter of Building Pad
12"
FL',
8.4
107.0
109.5
14.0
97.7%
Yes
2
t-W Corner of Building Pad
12"
FL
9.1
106.4
109.5
14.0
97.2%
Yes
3
E Corner of Building Pad
12"
FL
9.7
106.1
109.5
14.0
96.9%
Yes
4
5
6
8
9
10
11
12
13
14
Rema �I s: See Reverse Side (Page 2 of 2) for,Additional Information for Disclaimer
This is a Compaction Test only on the top 12" of the pad and is not a verificatio of SoVE earigg Capacity.
Legend or Elevation:
Z' A �
PR = P ofroll 1,2,3 = 1st, 2nd, 3rd Lift Submitted by:
SL = Sringline FL = Final Lift Keith. LeBlanc,' P.E.
SG = S. bgrade BG = Below Grade Federal Engineering &,Testing, Inc:=
BC = B i ecourse BOF = Bottom of Footing Florida Reg. No. 59394
TOP = I� p of Pipe FG = Finished Grade Certificate of Authorization #5471
As a mutt I protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorization for pub!lcation of statements,
conclusio s or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree of compaction of the tested layer of material
only. A de sity does not replace a soil bearing capacity determination. These density tests do not certify the underlying•soii "materiais b9ldw the prdpVSed structure. The results
do not pre lude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certify that the underlying soils will su► oort the proposed structure
without se lement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be perfomiedro (;valuate the,su'itability of the 'underlying
soil to sup' ort the proposed structure. After laying dormant for a period of 90 days or after heavy rain/storms, retesting must be performed on this work.
PAGE 1 of 2
Compacted Solis Method D-6938 Disclaimer
Pursuant to your request, Federal Engineering & Testing, Inca (FETj has' performed a compaction test at the referenced
project on the reverse side. -The purpose of our test was to determine the degree of compaction -of the tested layer .of
material only. In no way shall a compaction test replace a soil bearing capacity determination. A soil boring test must be
performed by the client prior to construction to verify subsoil conditions. Our scope of services only included testing the top
12" of added fill material. FET was not contracted to -perform supervision of the building pad preparation. This testing of t(ille
added fill material does not include an, analysis of the underlying soil materials to determine if they are capable of`supporting
the proposed structure without settlement. This density compaction test does not warranty any underlying soil materials Ior
conditions below the tested top 12 inches of material. If no soil borings have been performed in the location of the proposed
structure, we recommend performing soil borings below all foundation areas of the proposed structure to verify the underlying
soil conditions.
Environmental analysis of the soil materials is not part of the scope of services. If environmental analysis of the soils''is
required', we can provide a proposal for performing an environmental analysis of the soil materials. The scope of services) ;is
for determination of the degree of compaction of the tested' layer of material only. No -other analysis is implied or warranted.
Job project specifications were not available at the time the work was performed. Determination of the pass/fail compaction
results are based on current common industry requirements of 95% of the ASTM D-1557 standard for building foundations
and 98% of the AASHTO T-180 standard for paved areas such as roadways and parking lots. If different specifications are
required, Federal Engineering & Testing, Inc..shall be notified.
Our findings are relative to the date and areas of our site work and should not be relied upon to represent conditions on other
areas or dates. Any subsequent site disturbances due to water erosion, rain waters, construction activities, excavations,
,overgrown, vegetation, traffic and other disturbances will void this test and the site must be re -compacted and re -tested prior
to construction.
As a mutual protection to clients.,the public and ourselves, all reports are submitted are the confidential property of clients
and authorization for use, publication of statements, conclusions or extracts from or regarding our reports is reserved
pending written approval.
It has been a pleasure working with you and we look forward to doing so in the near future.
I!
Page 2 of 2
REIgz ��D
LMA
I L ECQPYo9-.-)1)V
e eraeSt.
Phone 954-784-2941
800-848-1919
Fax 954-784-7875
& TESTING INC.
St �U 9 ��panitr;
www.fed-eng.com
25
JSW 13th Ave Pompano Beach, Fl. 33069
Field Density Tests of Compacted Soils Method D-6938
P
ject: Proposed Residence Lot 11, Creekside
Date:
October 5, 2018
A
dress: 3142 Tidewater Circle, Fort Pierce, FL
Order #:
18DR886
A
a Tested: Building Pad
Permit #:
190? =6013 °y
M
terial Type: Pale Brown Sand with Traces of Shell
Tech:
BK
Client:
D.R. Horton, Inc.
A
l dress: 1430 Culver Drive NE
Compaction Req.:
95%
Palm Bay, FL 32907
Proctor Method:
ASTM D-1557
Te
t
TEST LOCATION
Probe
Depth
Elev.
Moist
%
Dry
Density
PCF
Proctor
Value
PCF
Optimum
Moisture
%
Compaction
Pass
Center of Building Pad
12"
FL
8.4
107.0
109.5
14.0
97.7%
Yes
SW Comer of Building Pad
12"
1 FL
9.1
1 106.4
109.5
14.0
1 97.2%
Yes
NE Corner of Building Pad
12"
FL
9.7
106.1
109.5
14.0
96.9%
Yes
6I1
Eli
91
1d
11'
1
1'
1 11
,►ot'tii�ir��.
Rer harks: See Reverse Side (Page 2 of 2) for Additional Information for Disclaimer ��'� )OM Z'�--Zzd1,
This Is a Compaction Test only on the top 12" of the pad and Is not a verification of Soi ea_ri P -capa'cl_ty:<;,-,
Leg nd for Elevation:
PR Proofroll 1,2,3 = 1st, 2nd, 3rd Lift Submitted by:
SL Springline FL = Final Lift Keith LeBlanc, P.E: u i
SG '- Subgrade BG = Below Grade Federal Engineering & TQiMg I ' q
BC ' Basecourse BOF = Bottom of Footing Florida Reg. No. 54394
r•
TOP = Top of Pipe FG = Finished Grade Certificate of Authorizatl6n'#54 t��-�,`•`�t
Asa Autual protection to clients, the public and ourselves, all reports are submitted as the confidential property of clients, and authorl2afAlnl rypubllca"on �siatemants,
concl ¢ions or extracts from or regarding our reports is reserved pending our written approval. A density test determines the degree of compacttoPycf thritest�d layer of material
only. i density does not replace a soil bearing capacity determination. These density tests do not certify the underlying soil materials below the prorposed siructure. The results
donol reclude or guarantee that future settlement and cracking will not occur. A soil boring test is required to certlry that the underlying soils will support the proposed structure
withou settlement. If no soil borings have been performed to verify the underlying soils, we recommend that soil borings be performed to evaluate the suitability of the underlying
soil to upport the proposed structure. Aker laying dormant for a period of 90 days or after heavy rain/storms, retesting must be performed on this work.
PAGE 1 of 2