July 31, 2018
RE: 5500 Orange Avenue
Whom It May Concern:
ISGANNED
BY
. l c!e Counbi
r office has performed design pressure calculations for the above referenced project and herby certify
it the proposed garage door is in compliance with the 2017 Florida Building Code, 160 mph wind zone,
)osure "C", risk category II.
Table 1609.3.1: Vint= 160mph
V,,d= 124mph
Table 1609.7(1): 12'h x 20'w door, 160mph = +23.3/-26.0
Table 1609.7(2): 30' mean roof height, Exposure C =1.21
red Design Pressures: 23.3 x 21= 28.19
-26 x 21= -31.46
ict: Janus International Corporation FL# 12765.3, Series 3100 26 ga. Door Assembly
ict Pressures: -+36.0 & -41.0
Seal, AIA