Loading...
HomeMy WebLinkAboutLETTER DESIGN PRESSURE CALCULATIONSArchitectonic- Inc St. Lucie County Planning & Development Services Building and Code Regulation Division July 31, 2018 RE: 5500 Orange Avenue Whom It May Concern: ISGANNED BY . l c!e Counbi r office has performed design pressure calculations for the above referenced project and herby certify it the proposed garage door is in compliance with the 2017 Florida Building Code, 160 mph wind zone, )osure "C", risk category II. Table 1609.3.1: Vint= 160mph V,,d= 124mph Table 1609.7(1): 12'h x 20'w door, 160mph = +23.3/-26.0 Table 1609.7(2): 30' mean roof height, Exposure C =1.21 red Design Pressures: 23.3 x 21= 28.19 -26 x 21= -31.46 ict: Janus International Corporation FL# 12765.3, Series 3100 26 ga. Door Assembly ict Pressures: -+36.0 & -41.0 Seal, AIA Delaware Avenue Tel: 772 460 7751 www.architedtonicinc.com Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1