Loading...
HomeMy WebLinkAboutEVALUATION REPORT ASPHALT ROOF SHINGLESTRINITY 1 ERD I am AUG 3 12018 ST. Lude c'ountyf EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 EV 14.UATION REPORT GA Il Evaluation Report 01506.01.08-1122 1 Ca; pus Drive FL10124-R20 Parsippany, NJ 07054 Date of Issuance: 01/03/2008 (80 766-3411 Revision 22: 09/20/2017 SCO This valuation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of cons ruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. or use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The pro' cts described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code sectins noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABUI NG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted here�I and FBC 1507.2.7.1 / R905.2.6.1. CONY1NUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the refer' nced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acce tance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the prod ct changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete revie 11 of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVE TISEMENT: The Evaluation Report number preceded by the words "Trinity ERD Evaluated" may be displayed in adve ising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPE I� ION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its dis ributors and shall be available for inspection at the job site at the request of the Building Official. This E'll aluation Report consists of pages 1 through 6. Preps ied by: Rober�J.M. Nieminen, P.E. Florida egistration No. 59166, Florida DC4 ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P,E. on 09/20/2027. This does not serve as an electronically signed document. CERTIFI TION OF INDEPENDENCE: 1. Tri 11.ItyIERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or dis Ibuting products it evaluates. 2. Tri tyl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Ro rt Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for whi h the evaluation reports are being issued. 4. Rol, rt Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the 5. Thilllis a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any pro' ct on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained spe4fically for that purpose. 3. I �J\T�RINITYJERD SYSTEMS EVALUATION: SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1507.2.4/ 1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3 / R905.1.1 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 REFERENCES: Kattl Examination Reference Date _ GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL (TST 1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 U L (TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 lesearch and Design, I.I.C. Evaluation Report 01506.01.08-R22 of Authorization #9503 6'" EDITION (2017) FBC NON-HVH2 EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 2 of 6 4. rTRINITY ERD Enfty Examination Reference Date UL (TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 10CA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK12070 11/04/2010 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL, LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, U.C. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, U.C. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, U.C. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 10/20/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 11/01/2016 UL, U.C. (QUA 9625) Quality Control Inspection Report, R21, Shafter, CA 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 10/21/2016 UL, I.I.C. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 11/17/2016 UL, I.I.C. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 11/04/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Ennis, TX 11/03/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 11/01/2016 PRODUCT DESCRIPTION: 4.1 Asphali Shinm: 4.1.1 Marq is ' eatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, Fortitude'", GlenwoodTM', Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield'm, Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldTM II, Timberline® Natural Shadow® Timberline l$t3" Timberline® Cool Series®, Timberline Ultra .k HD® and Woodland® are fiberglass reinforced, lamiriated asp alt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldlm Ridge Cap Shingles and imbe�rtex�,.P.cemium Ridge Cap Skiing a re fiberglass reinforced, hip and ridge asphalt roof shingles. iResearch and Design, U.C. Evaluation Report 01S06.01.08-R22 e of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-RZO GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 6. F)o -JI RINITY I ERD 4.3 Accessory Starter Strips: 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch" Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatchTm are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (V,It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to VM =150 mph (V„It =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles or Starter Strip 6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Research and Design, I.I.C. Evaluation Report 01S06.01.08-1122 e ofAuthorizoNon #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL30124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 4 of 6 C)o TRINITY, ERD 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite Pl. S30 Roof & Flashing Sealant". 11.51 Sealant 1 • (292 mm) 1 ° Sellante (25 mm) (25 mm) Enduit d dtanchM6 • • 12' (305 mm) Nail Clavo 6 518' - 7 5/8' Clouer (168 -194 mm) 12' (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 11.5, Sealant t• CMMM) 1- Sollanlo (25 mm) (25 rn;/Geduit d'bt sch616 Nall al% t 12' anuer 1(305 n:rn) 9' (220 MM) 12' (3305 MM) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. r Research and Design, I.I.C. Evaluation Report 01506.01.08-R22 to ojAuthorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 5 of 6 7, 8. 9. TRINITY I ERA LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 611320-3 QA requirements. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Research and Design, I.I.C. Evaluation Report 01506.01.08-1122 > oJAuthorimHon #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 6 of 6 TRINITY I ERD REPORT 1 C Impus Drive Par ippany, NJ 07054 (80 )766-3411 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report O1S06.01.08-R22 F1.10124-1120 Date of Issuance:01/03/2008 Revision 22: 09/20/2017 Thi Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of contruction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The pros ucts described herein have been evaluated for compliance with the 6t" Edition (2017) Florida Building Code sectIons noted herein. GAF Asphalt Roof Shingles LAB' LING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted her in and FBC 1507.2.7.1 / R905.2.6.1. Co ITINUEo COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the WE enced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acc ptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete revs w of this Evaluation Report relative to updated Code requirements with each Code Cycle. 17 ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in adv rtising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INS crION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or I ts Istributors and shall be available for inspection at the job site at the request of the Building Official. Evaluation Report consists of pages 1 through 6. ared by: t J.M. Nieminen, P.E. Registration No. 59166, Florida DC4 ANE1983 The facsimile seal appearing was authorized by Robert Nleminen, P.E. on 09/20/2017. This does not serve as an electronically signed document. CERTIhCATION OF INDEPENDENCE: 1. IrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or istributing products it evaluates. 2. Rich nityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. bert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for the evaluation reports are being issued. 4. k� obert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any roject on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 1.1 2.1 3.1 C)o \I TRINITY I ERD SYSTEMS EVALUATION: SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1507.2.4 / 1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3 / R905.1.1 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 REFERENCES: kniLW Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 01NK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 01NK9226 05/21/2001 UL(TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 01NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/2005 UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 OSNK27924 02/10/2006 UL(TST 1740) ASTM D3161 OSNK27924 02/11/2006 UL (TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161,D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161,D7158,D3462 08CA06100 03/13/2008 Research and Design, I.I.C. Evaluation Report 01506.01.08-R22 r ofAuthorizotion N9503 6EDITION (2017) FBC NON-HVHZ EVALUATION F1.30124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 2 of 6 4.11 C)o ,I I RINITY I ERD Kafty Examination Reference Date UL (TST 1740) ASTM D3161,D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161,D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161,D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161,D7158,D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161,D7158,D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161,D7158,D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161,D7158,D3462 IOCA13686 05/15/2010 UL (TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL (TST 1740) ASTM D3462 10CA11953 10/29/2010 UL (TST 1740) ASTM D3161,D7158,D3462 1ONK11951 10/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 IONK12070 11/04/2010 UL (TST 1740) ASTM D3161,D7158,D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161,D7158,D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48408 12/08/2011 UL (TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161,D7158,D3462 4787434542 05/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 10/20/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 11/01/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Shafter, CA 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 10/21/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 11/04/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Ennis, TX 11/03/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 11/01/2016 PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, Fortitude', Glenwood TM, Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShieldT"", Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldT"I II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldTm Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Research and Design, I.I.C. Evaluation Report 01506.01.08-1122 a ojAuthorizoNon #9503 6Te EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 6. �IT�NInIERD 4.3 Accessory Starter Strips: 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker'"" Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatch1m Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch'"' are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to V,,d = 150 mph (V,,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (V„it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61620-3. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 611520-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6.2 Starter Shinales or Starter Strip: 6.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot, Camelot 11, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Research and Design, I.I.C. Evaluation -Report 01S06.01.08-R22 ,e of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 4 of 6 C�o TRINITY I ERD 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite Pl. S3O Roof & Flashing Sealant". 11.5° Sealant 1• (292 min) 1° Sellante (25 mm) (25 mm) Enduit d'dtanchdite tf d l ' 12 (305 min) Nail Clavo 6 5/8° - 7 5/8° Clouer (168 - 194 mm) 12' (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel Pl. Roofing and Flashing Sealant. it - 51 Sealant 1• (292rim) t" Sollenlo (25 mm,) (25 rmn firtduit d'6tand1&be il•' • I Nail cbv0 B2° C-ouer (305 wrn) (229 rim) U I t2- (20S rmn) 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R9O5.2.5. Staples are not permitted. Research and Design, I.I.C. Evaluation Report 01506.01.08-R22 e ojAuthorizatio,10503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL20124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 5 of 6 7.1' 8.1 9.1 \�I TRINITY I ERD LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - 19 Research and Design, U.C. Evaluation Report 01506.01.08-1122 be ojAathorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION FL101241120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 6 of 6