Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED dy iuclec®nobf B R W Building Consultants, Ir Consulting and Engineering Services for the Building Indi P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate of Authorization No. RECEIVE AUG 31 201 ST. Lucie County, Product Sub Category Manufacturer Product Name �i Category Amerimax Home Products, Inc. 450 Richardson Drive P O— rd V that Pedonitastt Panel Walls Soffits Lancaster, PA 17604 tNrl �ofit Telephone: 717.228.3714 u Scope: This is a Product Evaluation report issued by RW Building Consultants, Inc. and Lyndon F. Schmidt, P.E. (Syst ID # 1998) for Amerimax Home Products, Inc. based on Rule Chapter No. 61 G20-3, Method 1 D of the State of Florid Product Approval, Department of Business & Professional Regulation. II RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the comp ny manufacturing or distributing the product or in any other entity involved in the approval process of the product na ed herein. 1 Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural req irements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wa dressing or stucco. 3. Site conditions not covered by the details of drawing FL-5896.1 require further engineering analysis by a licensed engineer o registered architect. 4. Wood/CBS wall construction, by others, must be designed properly to receive loads from the soffit and/or 2" x 2° batten stripsli 5. All connectors shall be corrosion resistant. 6. Aluminum soffits shall conform to the specification and labeling requirements of FBC Section 1709.10. 7. The perforated panel soffit has been tested for Wind Driven Rain according to TAS 100(A): 8. See drawing FL-5896.1 for size and design pressure limitations. Supporting Documents: 1. Test Report No. Test Standard Testing Laboratory Signed by TEL 05-1116-1 TAS 202-94 and TAS 203-94 Testing Evaluation Lab.,lnc. Wendell W. Haney P.E. G9146.01-109-18 TAS 100(A)-95 Architectural Testing, Inc. Joseph A. Reed. P 2. Drawing No. Prepared by Signed & Sealed g (�Rc�.aa; Lyndon F. Schmidt, E. No. FL-5896.1 RW Building Consultants, Inc.. CA#9813) � � ocQcf Y 3. Calculations Prepared by A�� �,-, O E ,ti! &, s c�o� Signed &Sealed b. Anchoring RW Building Consultants, Inc. (CA #9813) Ho d�Lyndon F. Schmidt, I .E. o c;.; 409 ° 4. Quality Assurance o Certificate of Participation issued by National Accreditation and Management Institute, certifying that Amerimax Home Products, Inc. is •� o Spa ra a E OF manufacturing products within a quality assurance program that compliesAl with ISO/IEC 17020 and Guide 53.E ` L G t���� Lyndon F. Schmidt, E. FL PE No. 4 09 Sheet 1 of 1 HOME PRODUCTS, INC. 450 RICHARDSON DRIVE, LANCASTER, PA 17604 PHONE: 717-228-3714 STANDARD V PANEL & STANDARD PERFORATED V PANEL ALUMINUM SOFFIT GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown an details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 4. For design pressure ratings see chart this sheet. 5. Wood/CBS wall construction by others, must be designed property to receive loads from the soffit and/or 2" x T' batten strips. 6. All connectors shall be corrosion resistant. 7. Aluminum soffits shall conform to the specification and labeling requirements of FBC Section 1709.10. B. The perforated panel soffit has been tested for Wind Driven Rain according to TAS 100(A). TABLE OF CONMM SHEErR DESCRIPTION 1 Typical elevation, design pressures & general notes 2 Typical anchoring decals & soffit details 3 Typical anchoring detals & soffit detaiiis 4 BIII of motericils & components ALUM. 3105-H25 12'STANDARD V PANEL (MAX 24"SPAN) ALUM.3105-H25 12" STANDARD PERFORATED V PANEL (MAX 24"SPAN) ;DESIGN PRESSURE (PSO: -" :: :SOEFirTMODEL` POSITIVE: ,::NEGATIVE._ 12" STANDARD V PANEL SOFFITT +50.0 -50.0 12" STANDARD'V PANEL SWIM +50.0 -50.0 (PERFORATED) •! . * _ • ., •. �.0 Z 9o;; JltI 111 0mz° ds z °z _ �m cw 11 maa12 000 u nno i .f N Z O 03 23 09 = = N.T.S.WS 9 3 ar: Dm er: LFS 3 rc FL-5896.1 .T 1 OF 4 0 TYP INSTALLATION ON A WOOD WALL V SGSTWG STRUCTURE 6 � 4 10 HORIZONTALLY oc 3 "A DETAIL J CHANNEL INSTALLATION n a "TUAL ROOF PITCH VARIES M IG=0.42OR BOYER) NX.24" O.C. SPACING I6' O,C. MAX. —_ETAIL%1 FOR J CHANNEL INSTALLATION SEE DETAIL "6 FOR SOFFIT INSTALLATION (TYP.) EXISTING STRUCTURE DETAIL "B" SOFFIT INSTALLA77ON ACTUAL ROOF PITCH VARIES RAPIER (G = 0.42 OR BETTER) MAX 24' O.C. SPACING • d , °de TYP INSTALLATION ON A CBS WALL L SEEDETAIL"A FOR J CHANNEL INSTALLATION SEEDETAIL"B"FOR SOFFIT INSTALLATION (TYP.) INSTALLED AT EACH PANEL OVERLAP JOINT (12'MAX.O.C.) EDGE DISTANCE ,''�����► I 1111 1\,\ o d m z OR •: bm=V ug 9 0� N mda� VA\ li �Z ED pp�� 3a b� W np--Z 0312, 09 °z E N.T.S. 9 5 BY. DIMS m BY: LFS 3 a YWO NDa D FL-5B96.1 °o n 2 ov 4 n 24" O.C. MAX. SPACING FOR THESTRUCTURALSUPPORT (BY OTHERS) OF THE 2" X 7' BATTEN STRIPS .ETD AT EACH OVERLAP JOINT. SEE DETAIL A SHEET #2 FOR J CHANNEL INSTALLATION 3 2 SEE DETAIL V SHEET #2 g FOR SOFFIT INSTALLATION TYP, INSTALLATION 3 ON A WOOD WALL 24" O.C. MAX. SPACING FOR THE STRUCTURAL SUPPORT (BY OTHERS) OF THE 2" X 2" BATTEN STRIPS NSTALLEO AT EACH -(Dp AN(1 OVERLAP JOINT SEEDEAIL A SHEET#2 —� FOR J CHANNEL INSTALLATION SEE DETAIL V SHEET #2 FOR SOFFIT INSTALLATION 1 3 TYP. INSTALLATION ON A CBS WALL 24' ACTUAL ROOF PITCH VARIES �� 0'�,••''��-• RAFTER (G=0A2OR BETTER) MAX. 24" O.C. SPACING 8�18' O.C. MAX. 7': / 7 BATTENSI 16 O.C.MAX. B ACTUAL ROOF PITCH VARIES RAFTER (G =0A2OR BErM) MAX. 24" O.C. SPACING MOMENT SOFFITOVI CUT OU G 1 LOOKING UP ® SOFFIT 3 N.T.S. i , K� o 0 � zap a m d 8 N •• Z g' XZd z m c3 Em a a tt°B M 9 d t a a maa� 6 = 0 0 O tJ Z� a 5p 0`3 o2R �a Z ru aaZ �Q xOa �O or gyJ v� . d Bat old EIM-03I I l °_ 2c�a h n "gyp i na�z a =03 23/09 N.T.S. 'd 6W DWS m' BY. LFS ; VM NO.'. K m FL-5896.1 °a . 3 of 4 n BILL OF MATERIALS REM I DESCRIPTION MATERIAL 1 STANDARDV PANEL SOFFIT 0.0I7-THK. ALUMINUM 3105 H251 ALUMINUM 2 STANDARD PERFORATED V PANEL SOFRT O-017"THK.ALUMINUM 3105H25 ALUMNUM 3 STANDARD"J"CHANNEL OAI75'THK.ALUMINUM) ALUMINUM 4 JIG 0.125' MIN. x 1" LONG ROORNG NAIL WfIH 7/16" DIA. HEAD STEEL 5 ii8 x 1" PPHSMS STEEL 6 2' x 2" BATTEN STRIP SOUTHERN YELLOW PINE G = 0.55 OR BETTER WOOD . 7 1 Od COMMON NAIL IT LONG STEEL 8 108x2-I/7'PFHWOOD SCREW STEEL 9 3/1Vx 2-31,V ELCO UURACON CONCRETE SCREW, EMBEDMENT=1.25 MM., EDGE DISTANCE =1"MIN., CENTERLNE TO ADJACENT ANCHORS = 4' MIN. STEEL SUBSTRATE NOTES: 1. WOOD SUBSTRATE: G = OA2 OR BETTER 2. MASONRY SUBSTRATE: 3,000 PSI CONCRETE (ACI 301) OR HOLLOW BLOCK (ASTM C90). "V" PANEL l±fR Flow SO F fREEFiOINAREA :AREA PERFORATED 11.23 7.876 LR.,250"TYP. .077' MIN VIEW A - A PERFORATION DETAIL 2X SCALE a�a�0 a a�a"a�a aoaoadaoa�aoan°n anaaanannnnaaaa 6" 1.21' I r- O.R..020'TYP. TYP. lk I � ''�',� I I 10 I Ii �Ve 1. :W6 co a, Its alt1t v o g z°O 6.6• /y ` `e\ \\v1 (� �g 9m cw O o a a y� mdaLo OR � ...020"TYP. c .250" "; N ��I v 0.2r 1. o� g g � OSTANDARD V PANEL SOFFIT 1 RN.125RX.02DP. Egg EPA > � _ W� ti ^ \\ a J � g� -A d // ot= / 03(r nnn'aa °na' annnana a ,I a°a°n°a n°nan°a a� naabonn .. 0.125' -A 0.91 TYP. o 1YP. O- 1.81T TYP. N � 1 Y VIEWSHOWN FOR REFERENCE R.O50"TYP. OUTSIDE OSTANDARD "J" CHANNEL 0.27" wth 0312310 " I�- N.T.S. 1" c owo. BY: DWS OSTANDARD PERFORATED V PANEL SOFFIT cim BY. LFS 2 RIB .125 R X .02 DP. owoxmo No-- FL-5896.1 sKa 4 ov 4 0 z