HomeMy WebLinkAboutGENERATOR CONCRETE PAD\ \ GENERATOR
PAD \ %`
THICKNESS \ �� \• GIN
�PPO LEN
•c -n .Tr AETCSA/
PAD DIMENSIONS:
CONCRETE PAD
GENERATOR
= I GENERATOR UNIT BY
o SEPARATE SUBMITTAL
3 (SEE SCHEDULE FOR
N I MINIMUM WEIGHT
REQUIRED)
Ll
I} 54" LENGTH
°I PLAN VIEW
C)
CONCRETE PAD
ROAD MESH
CL MASTERFIBER 3" MIN
3 MAC100 �4" MIN
N
m GROUNDS rcc. .i•-z%r., ,... -: zzC
50"
54"
GENERATOR TABLE:
ERICAST GENERATOR CONCRETE PACE
(ON -GRADE APPLICATIONS ONLY)
ow
AMERICAST
RMUNMULOta corn
lu'W10IN AAMIMCM0,
FEDTA 0=4252361 LICENMO59fl.30pS0163
S M;W-w Aw. Fon Pines, FL 11922
Tel. 717A7]-193I Faz 773�6A-gyp
Email: yglea(.`aneri.easHaeran nr ehMdoiM2672�ohoee
lscMNw
BY
Sit. Lude
HVHZ OR NON-HVHZ
RISK
EXPOSURE EXP
RISK
EXPOSURE EXP
RISK
EXPOSURE EXP
COUNTY
I
C
I D
11
C
D
III, IV
C
I D
P. BEACH
150 MPH
30.44 Psfj
36.94 Psf
170 MPH
39.09 Psf
47.44 Psf
180 MPH
43.83 Psf
53.19 Psf
BROWARD
156 MPH
32.92 Psf
39.95 Psf
170 MPH
39.09 Psf
47.44 Psf
180 MPH
43.83 Psf
153.19 Psf
MIAMI-DADE
165 MPH
36.83 Psf
44.69 Psf
175 MPH
41.43 Psf
50.28 Psf
186 MPH
46.80 Psfj
56.80 Psf
BRAND &MODEL
CAPACITY
WIDTH
LENGTH
HEIGHT
WEIGHT
ALLOWABLE
PRESSURE
COMMENTS
Generac 005871 & 005883
10 KW
25.00 "
48.00 "
29.00 "
387 lbs
41.43 Psf
EXP C 175 MPH & D 156 MPH
Generac 005872 & 005884
14 KW
25.00 "
48.00 "
29.00 "
439 lbs
47.44 Psf
EXP C 186 MPH & D 156 MPH
Generac 6459, 6461, 6462
16 KW
25.00 "
48.00 "
29.00 "
51316s
47.44 Psf
Generac 006721
16 KW
25.00 "
48.00 "
29.00 "
448 lbs
47.44 Psf
Generac 005873 & 005885
17 KW
25.00 "
48.00'
29.00 "
455 lbs
47.44 Psf
Generac 005874 & 005886
17 KW
25.00 "
48.00 "
29.00 "
421 lbs
47.44 Psf
Generac 005875 & 005887
20 KW
25.00 "
48.00 "
29.00 "
451 lbs
47.44 Psf
Generac 006729 & 006730
20 KW
25.00 "
48.00 "
29.00 "
516 lbs
47.44 Psf
Generac 006551 & 006552
22 KW
25.00 "
48.00 "
29.00 "
526 lbs
47.44 Psf
Kohler 14RES & 20RES
14-20 KW
26.00 "
48.00 "
29.00 "
500 lbs
47.44 Psf
GE 40323GE & 40324GE
13 KW
35.00 "
39.40 "
39.00 "
540 lbs
39.09 Psf
EXP C 170 MPH & D 156 MPH
GE 04038215KW
15 KW
33.00 "
48.00 "
30.50 "
484 lbs
43.83 Psf
EXP C 180 MPH & D 156 MPH
GE 04037817KW
17 KW
33.00 "
48.00 "
30.50 "
484 lbs
43.83 Psf
GE 40330GE & 40331GE
20 KW
33.00 "
48.00 "
30.50 "
600 lbs
43.83 Psf
Briggs & Stratton 040243-0
10 KW
31.00 "
32.00 "
34.00 "
436Ibs
43.83 Psf
Briggs & Stratton 040302-2
12 KW
33.75 "
31.60 "
507 lbs
41.43 Psf
EXP C 175 MPH & D 156 MPH
Briggs & Stratton 040303-1
15 KW
33.75 "
31.60 "
562 lbs
43.83 Psf
EXP C 180 MPH & D 156 MPH
Briggs & Stratton 040304-1
18 KW
33.75 "
31.60 "
568 lbs
44.00 Psf
Briggs & Stratton 040305-1
20 KW
33.75 "9.00
31.60 "
570 Ibs
44.00 Psf
Generac 7035, 7036, 7037
16 KW
25.00 "
29.00 "
406 lbs
47.44 Psf
EXP C 186 MPH & D 156 MPH
Generac 007038 & 007039
20 KW
25.00 "
29.00 "
448 lbs
47.44 Psf
Generac 007042 & 7043
22 KW
25.00 "
1 29.00"
466 lbs
47.44 Psf
GENERATOR MOUNTING CONFIGURATION:
ANCHOR TO PAD SCHEDULE
SUBSTRATE I DESCRIPTION I
CONCRETE: (2)-3/8"0 TITEN HD
(6000 PSI OR EQUIVALENT,
MIN.) 2-3/4" FULL EMBED
O CONCRETE, 3" MIN
EDGE DISTANCE, 6"
MIN. SPACING TO ANY
ADJACENT ANCHOR.
NOTES:
1. ANCHOR QUANTITY PER LONG SIDE
2. EMBEDMENT AND EDGE DISTANCE
EXCLUDES FINISHES, IF
APPLICABLE.
3. ENSURE MINIMUM EDGE DISTANCE
AS NOTED IN ANCHOR SCHEDULE.
4. ENSURE MINIMUM SPACING TO
ANY ADJACENT ANCHORS.
5. FOLLOW MANUFACTURER'S
INSTALLATION INSTRUCTIONS TO
INSTALL ANCHORS.
GENERATOR
ATTACHMENT BASE,
VARIES WITH MODEL
SEE GENERATOR SPECS
GENERATOR %' SIMPSON TITEN HD,
GENERATOR ATTACHMENT BASE SEE ANCHOR SCHEDULE
OR SIMPSON A24 ANGLE BRACE 2"0"x3/e' GALV. STEEL -
W/ (4) #10 SS 316 SELF -DRILLING WASHER
SCREWS RUBBER VIBRATION PAD -
F ( TO GENERATOR
SEE TO
SPECS)
THICK GALVANIZED
GENELTOR WASHER& RUBBER
(-SEE_ CONCRETE PAD VIBRATION PAD Z
C7 CONCRETE PAD
DIICEFO - 6,000 PSI
& DIMENSIONS WEIGHT GHTiNEi
= I REQUIRED) CONCRETE PAD v X CONCRETE MIX6,000 PSI
4.. LIGHTWEIGHT ` MASTERFIBER MAC 100. j
LL�l Fl CONCRETE MIX & ROAD MESH
- - - - - -a - - -- - - - - -- -- I - NOTES: - - - - - - - - - -- - FOAM CORE
32" WIDTH 54" LENGTH -} 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH-, NO - LESS 2" ESS THAN :-
2. X DISTANCE 3" FROM UNIT EDGE TO CLIP.
m SIDE VIEW FRONT VIEW 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN
o ANCHOR REQUIREMENTS
t--zn--�
FRANK L. BEN RDO, P.E.
i
PE# 0D46549
�
3
03, f2�018
Ir tlE=CID, P.E. APPEARS 6aDW
DON M. I TTISTO, P.E.
2328
NOTICE: I IS SHEET DOES
�
NOT CON AN ORIGINAL
SIGNATURE & ENGINEER SEAL
IF THERE IS A DIGITAL
I
SIGNATURE ON SHEET 1, THIS
SHEET IS PART OF A DIGITALLY
SIGNED FILE, SHALL REMAIN IN
DIGITAL FORMAT, & PRINTED
COPIES OF THIS DOCUMENT
L
ARE NOT CONSIDERED SIGNEI
- _. - - - - - - - - - - - - - - - _ _ _ - -
WIND DESIGN REQUIREMENTS-
AND SEALED. IF THERE IS NO
RSsEETSHEET IOHET
DOES NOT
CONTAIN AN ENGINEER'S
ORIGINAL SIGNATURE & SEAL,
(BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION
(2017 ))
THIS SHEET IS A COPY DRAFT.
AT -GRADE SIGN METHOD
'n
tD
N
ULTIMATE DESIGN WIND SPEED Vult = 186 mph
0
NOMINAL DESIGN WIND SPEED Vasd = 144 mph
Z
li't p
RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A
®
LIJ M m U i
EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd=
C[ uJ
M `:9 In 0
Uj-J
0.85
W
W
LL .2 (A
ENCLOSURE CATEGORY = N/A HEIGHT H = AT GROUND
GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H = 77.56
W
W
LL (n ^' X N Tu
0 I? w
qh
= u'ri =
SZ
Ib/ft2
? �
w W U IL
FORCE COEFFICIENT Cf = 1.44
~ % Q " w w
�Q W
WIND PRESSURE -
Z
_.7uL90
m
P= qh G Cf = 56.80 Ib/ft2 (ASD)
X
o� 4��
N a n w u
W
O w
V '-1 W v @ Z
GENERAL NOTES -
N a=W
1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE
LLI
0 W w
SIXTH EDITION (2017).
PM
n
2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH
THIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A
JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE.
N N
SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH
O a ZO
THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUAL TO THE
DESIGN PRESSURE "ASD" CAPACITY VALUES LISTED HEREIN FOR ANY
W LU
ASSEMBLY AS SHOWN.
DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS
STATED HEREIN.
/�
\J) Q 00
(D a3.
y Z LU
4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL
Q 0 ONj
W
N I,) t
X
CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED.
5. CALCULATIONS MADE USING LIGHTWEIGHT CONCRETE 125 PCF
+y
V �
M
W In
6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL
I-1 n
ad W
W
HAVE ALL
VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR
W
00 =
.J p,cyl
N U) C1
TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS.
7. RESISTANCE TO SLIDING OF
N
W
m0 Z U
THE PAD ON THE GROUND IS NOT PART OF THIS
DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. .
Of n
C M O
LL
v g LD
z
a. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED & INSTALLED BY
C M
Y 0
OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.)
N
SHALL BE AS PER MANUFACTURER RECOMMENDATIONS AND ARE THE
ti IW- m
EXPRESS RESPONSIBILITY OF THE CONTRACTOR.
W V)
Q
9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS
Ur <
SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, et. al.
INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES
p
INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL
LL
FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT
Lu
m
r-
z
WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM
DEVIATIONS OF THIS PLAN.
Q a
.0
,
10. WATER -TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL
G o
S o
RESPONSIBILITY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL
ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS
RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE
In
LL m
PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY
V ,
WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS
WATER -TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING
LLo
2
3 O
O O
CONTRACTOR.
p g
g s
,
pzp
11. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY
T3 z o
ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE
6 $'
ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE
INTEGRITY OF ALL SUPPORTING SURFACES
¢ p
S o
TO THIS DESIGN WHICH SHALL
BE COORDINATED BY THE PERMITTING CONTRACTOR.
12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC
w o
S
PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON
CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS.
ENGINEERING EXPRESS
SHALL
id"
E
NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS
-- -- DIMENSIONS
ul
10c
-DATA-OP-MEASUREMIM - ARE SHOWN TO
-ESIGIT-CKl
z
-
ILLUSTRATE DESIGN FORCES AND O EKRIERIA-THE'PMAY1tA
COPYRIGHT ENGINEERING EXPRESS
SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN.
WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION.
J-�
1
ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO
REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE
.
INFORMATION PRIOR TO MODIFICATION. OF EXISTING FIELD CONDITIONS
SCALE: NTS UNLESS NOTED
AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR
/-�
OF
ADDITIONS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR
---CERTIFICATION
13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS
OR AFFIRMATIONS ARE INTENDED.
I