Loading...
HomeMy WebLinkAboutNOA'St. ti SCANNED ST. LUCIE COUNTYkG DMSI®Al By REVIEWED FOR CO ,�s r-VIE . 2. I�:O@'c OU � ATE 1IAP0! PLANS ND ERMIKEWtn PT ON JOB ,o , rlli SITE OR NO INSPEWILL BE MADE DEPARTMENTOF REGULATORY AND ECONOMIC RESOURCES (PER) BOAfiD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NOA) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 31525-99 www.miamidade.p,ol/econolnv Cert4inTeed Corporation CONCEALEDFASItNtli�VMHI IRuniviririv 18 Mbores Road Mals�ern, PA 19355 ARE.TNE_AESPONSIBILITY OF THE 1, CONTRACTOR OF RECORD, SCO,rE: This 1 OA is being issued under the applicable rules and regulations governing the use of construction materials. The docu entation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used J,,n Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This OA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In �lami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this prod ct or material tested for quality assurance purposes. If this product or material fails to perform in the accepted mann9r, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspe 'l d the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it isi determined by Miami -Dade County Product Control Section that this product or material fails to meet the requi ements of the applicable building code. o v rn M x g"<OmM '�WCaM This roduct is approved as described herein, and has been designed to comply with the Florida Building Code m v � -o ZE inclu ing the High Velocity Hurricane Zone of the Florida Building Code. = 0 � 0 CD C"-n-4> cnmpv DES 1,1 RIPTION: CertainTeed Modified Bitumen Roofing Systems over Wood Decks. ry n y �zz r LAB LING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and follow�6 rn 0 state nt: "Miami -Dade County Product Control Approved", unless otherwise noted herein. W m _f m v roo000 Cn REN WAL of this NOA shall be considered after a renewal application has been filed and there has been no chw o in the 'applicable building code negatively affecting the performance of this product. u' 9 TER1�!�[INATION of this NOA will occur after the expiration date or if there has been a revision or change in the matert ils, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sal as, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. 'ISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its -INSPE'CTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall bell available for inspection at the job site at the request of the Building Official. This NOA revises NOA #14-0224.03 and consists of pages 1 through 42. The submitted documentation was reviewed by Alex Tigera. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 1 of 42 8 WING SYSTEM APPROVAL Ilo 'ate : Roofing tate or : Modified Bitumen P ial: APP/SBS ub- late leck e: Wood Design Pressure: -127.5 psf. Zaxiitnum T ' E NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description All eather/Empire Base 39 3/s" x 65' 10"; ASTM D 4601, Type Asphalt coated, fiberglass reinforced Sheet Roll weight: 70 lbs. II base sheet. (2 squares) UL Type G2 Flexi as Base Sheet 39 3/8" x 98'9"; Roll ASTM D 4601, Type Modified Bitumen coated fiberglass weight: 90 lbs. II base sheet. (3 squares) UL Type G2 Flintl tic Base 20 39 3/s" x 49' 6"; Roll ASTM D 6163, Modified Bitumen coated fiberglass weight: 90 lbs. Grade S, Type I base sheet. (1.5 squares) Flintg as Ply Sheet Type IV 39 3/s" x 1647'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply sheet. weight: 381bs. IV (5 squares) UL Type G1 Flintgl s Premium Ply Sheet 39 3/s" x 1647'; Roll ASTM D 2178, Type Fiberglass, asphalt impregnated ply Type I weight: 40lbs. VI sheet. (5 squares) UL Type G1 Flintla tic STA 39 3/s" x 32' 10"; Roll ASTM D 6222, Smooth surfaced APP Modified weight: 87 lbs. Grade S, Type I Bitumen membrane with non -woven I (1 square) polyester mat reinforcement for torch application. Flintla Itic GTA 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintla is GTA-FR 39 3/8" x 32' 10' ; Roll ASTM D 6222, Granule surfaced APP Modified weight: 105 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Flintla ' is GMS 39 3/a" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 94 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. i NOA No.: 14-0529.02 MIAMMADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 2 of 42 NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Premium GMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 101 lbs. Grade G, Type II Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. FR-P 39 3/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Premium FR-P 39 3/8" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 101 lbs. Grade G, Type II Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. FR Dual Cap 39 3/8" x 32' 10"; Roll ASTM D 6162, Granule surfaced SBS modified weight: 103 lbs. Grade G, Type I bitumen membrane with a nonwoven (1 square) polyester/fiberglass composite mat reinforcement for use in cold or mop applications. FR Cap 30 39 s/s" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 86 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. FR Cap 30 T 39-3/8" x 32' 10"; Roll ASTM D 6163, Granule surfaced SBS Modified weight: 100 lbs. Grade G, Type I Bitumen membrane with fiberglass (1 square) mat reinforcement for torch application. Base 20 T 39-3/8" x 33'; Roll ASTM D 6163, Modified Bitumen, coated fiberglass Weight: 81 lbs. Grade S, Type I base sheet for torch application. (1 square) FR Cap 30 CoolStar 39 s/s" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 88 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. FR Cap 30 T 39 3/8" x 32' 10"; Roll ASTM D 6163, Fire resistant, granule surfaced SBS weight: 102 lbs. Grade G, Type I Modified Bitumen membrane with (1 square) fiberglass mat reinforcement for mop applications. Covered with reflective CoolStar Coating. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 3 of 42 'I TRA I Flintl Flint] Flintl Base NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description GTA CoolStar 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 1061bs. Grade G, Type I Bitumen membrane with non -woven . (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. GTA-FR CoolStar 39 3/8" x 32' 10"; Roll ASTM D 6222, Granule surfaced APP Modified weight: 1061bs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for torch application. Covered with reflective CoolStar Coating. GMS CoolStar 39 3/s" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 97 lbs. Grade G, Type I Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Premium GMS 39 3/8" x 32' 10"; Roll ASTM D 6164, Granule surfaced SBS Modified weight: 103 lbs. Grade G, Type II Bitumen membrane with non -woven (1 square) polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. FR-P CoolStar 39 3/s" x 32' 10"; Roll ASTM D 6164, Fire resistant, granule surfaced SBS weight: 103 lbs. Grade G, Type I Modified Bitumen Membrane with (1 square) non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. Premium FR-P 39 3/8" x 32' 10"; Roll weight: 103 lbs. (1 square) Ultra Poly SMS 39 3/s" x 32' 10"; Roll t weight: 90 lbs. (1 squares) Glasbase Base Sheet 36" x 98' 9"; Roll weight: 75 lbs. (3 squares) ASTM D 6164, Fire resistant, granule surfaced SBS Grade G, Type II Modified Bitumen Membrane with non -woven polyester mat reinforcement for mop application. Covered with reflective CoolStar Coating. ASTM D 6164, Smooth surfaced SBS Modified Grade S, Type I Bitumen Membrane with non -woven polyester mat reinforcement for mop applications. ASTM D 4601, Type Asphalt coated, fiberglass base sheet. II, UL Type G2 NOA No.: 14-0529.02 M", I•DADE COUNTY . • • • • � Expiration Date: 06/19/18 ! I Approval Date: 09/24/15 Page 4 of 42 I TRA i Flintl si Sheet Yose i NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Poly SMS Base Venting Base Sheet Flintl §tic APP Base T i II Flintl tic Ultra Glass SA I Black iamondTM Base Sheet APPROVED INSULATIONS: Dimensions 39 3/s" x 64' 3"; Roll weight: 901bs. (2 squares) 39 3/8" x 32' 10' ; Roll weight: 85 lbs. (1 square) 39 3/8" x 65' 4"; Roll weight: 100 lbs. (2 squares) 39 3/8" x 33' 11"; Roll weight: 73 lbs. (1 square) 36" x 687'; Roll weight: 781bs. (2 squares) Test Product Specification Description ASTM D 4601, Modified Bitumen coated polyester Grade S, Type II ' base sheet. UL Type G2 ASTM D 3909 Mineral Surfaced fiberglass reinforced ASTM D 4897, Type buffer sheet. II UL Type G3 ASTM D 6509 Modified Bitumen coated fiberglass base sheet. I:T, IY0"D &W ASTM D 1970 TABLE 2 Product Name Product Description i F1intB and ISO Polyisocyanurate foam insulation F1intB iardH ISO Polyisocyanurate foam insulation ACFO -II Polyisocyanurate foam insulation High Density Wood Fiberboard Wood fiber insulation board Perlite nsulation Perlite insulation board DensD ck, DensDeck Prime Water resistant gypsum board H-Shie Polyisocyanurate foam insulation I ENRG 3 Polyisocyanurate foam insulation ENRG 3 25 PSI Polyisocyanurate foam insulation Multi- ilax FA-3 Polyisocyanurate foam insulation SECUI�16,CK Gypsum -Fiber Roof Board homogenous fiber reinforced Self -adhering, fiberglass reinforced, SBS modified bitumen base/ply sheet. Self -adhering fiberglass reinforced modified bitumen base sheet Manufacturer (With Current NOA) CertainTeed Corporation CertainTeed Corp. Atlas Roofing Corp. Generic Generic Georgia Pacific Gypsum LLC Hunter Panels LLC Johns Manville Corp. Johns Manville Corp. RMax Operating, LLC USG Corp. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 5 of 42 1.' 2. 3. 4. 5. 6. 7. 8. 9. 10 11 12 13 14 ) FASTENERS: TABLE 3 Product Product Manufacturer Name Description Dimensions (With Current NOA) Trufast #12 DP Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. Trufast 3" Metal Galvalume steel plate 3" round Altenloh, Brinch & Co. U.S., Insulation Plate Inc. FlintFast #12 Coated, carbon steel screw various CertainTeed Corp. FlintFast 3" Insulation Galvalume AZ50 steel plate 3" round CertainTeed Corp. Plate FlintFast #14 Insulation fastener for wood various CertainTeed Corp. and steel decks Simplex MAXX Cap Polymer fastner 1" long Simplex Nails, Inc. OMG #12 Standard Insulation fastener for wood various OMG, Inc. Roofgrip and steel. OMG 3" Galvanized Steel Galvalume stress plate 3" round OMG, Inc. Plates Trufast #14 HD Fastener Insulation fastener for wood various Altenloh, Brinch & Co. U.S., and steel decks Inc. OMG Heavy Duty Insulation and membrane Various OMG, Inc. fastener OMG 3 in. Round Metal Galvalume AZ50 steel plate 3" round OMG, Inc. Plates AccutTrac Hextra Carbon steel fastener Various OMG, Inc. AccuTrac Plates Galvalume stress plate. 3" square OMG, Inc. AccuTrac Flat Bottom A2-SS aluminized steel plate 3" square OMG, Inc. Plates NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 6 of 42 3 k SURFACING/COATING OPTIONS: TABLE 4 i components must be applied according to manufacturer's application instructions. Any coating, listed used as a surfacing, must be listed within a current NOA. a Number Manufacturer Application Generic Gravel applied at 400 lbs/sq., adhered with flood coat of asphalt at 601bs/sq. Generic Slag applied at 3001bs/sq., adhered with flood coat of asphalt at 60 lbs/sq. Karnak Corp. Karnak (#97 AF) Fibrated Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. CertainTeed Corp. F1intCoat A-150 applied at an application rate of 1.5 gal/sq. Gardner Asphalt Corp. APOC #212 Fibered Aluminum Roof Coating applied at an application rate of 1.5 gal/sq. Gardner Asphalt Corp. APOC #400 Sunbrite applied at an application rate of 3 gal./sq. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 7 of 42 PRI P,NCE SUBMITTED: Test Aeency/Identifier Name Report Date Mutual Research Corp. FM 4470 3Y8ALAM 03/23/96 FM 4470 OD3A3.AM 04/04/97 FM 4470 2DOAO.AM 12/23/98 FM 4470 1D7A4.AM 11/09/98 FM 4470 3039046 06/15/10 FM 4470 3048520 09/19/13 rriters Laboratories, Inc. UL 790 R11656 01/11/13 States Testing Company ASTM D 5147 97457-4 06/03/88 ASTM D 5147 97-457-2R 12/02/87 .turn Technologies, Inc. ASTM D 4601 AX31G81) 09/05/08 ASTM D6164 AX31G8F 06/05/09 ASTM D6222 AX31G8G 06/05/09 ASTM D 3909/ D 4897 AX31G8C 09/05/08 TAS 114(J) 3504.06.01-1 06/05/01 TAS 114(J) 3507.08.99-1 04/18/01 TAS 117 (13) 3503.10.06 10/10/06 TAS 117 (13) 06490.04.07-R1 06/27/07 TAS 114 (H) Letter 04/05/06 TAS 114 3533.01.06 01/06/06 TAS 114 3521.0.7.04 07/29/04 TAS 117 (B)/ ASTM D 6862 C8500SC.11.07 11/30/07 TAS 114 C8370.08.08 08/19/08 ASTM Physical Properties C10080.09.08-R4 03/25/10 ASTM D6164/D4798 C31410.01.11-2 01/10/11 ASTM D4601 C40050.09.12-1 09/28/12 ASTM D1970 C40050.09.12-2 09/28/12 ASTM D5147/D4798 C31410.10.10-R1 11/01/12 ASTM D5147/D4798 C31410.01.11-1-R1 11/01/12 ASTM D1876 C35460.05.11 06/16/11 ASTM D1876, TAS 114 (H), C42110.08.12 08/13/12 TAS 117 (B) FM 4474/TAS 114 C39670.08.12 08/20/12 TAS 117B C35500.02.11 02/09/11 ASTM D4798 C31410.01.11-2A-Rl 02/21/13 ASTM D4798 C31410.12.13 12/05/13 ASTM D6222 C40050.12.13-R1 12/31/13 TAS 117, TAS 114 C30310.12.09-R1 03/07/14 ASTM D1876, TAS 114 (H), C45620.03.14 03/27/14 FM 4474 ASTM D1876, TAS 114 (H), C47320.03.14-R1 04/01/15 FM 4474 ;ion Materials ASTM D6163 CTC-032-02-01 01/22/08 LLC ASTM D6163 CTC-066-02-01 08/09/11 ASTM D6222 CTC-070-02-01 08/09/11 NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 8 of 42 CE SUBMITTED: Test Agency/Identifier Name Report Date ASTM D6164/D4798 CTC-093-02-01 08/09/11 ASTM D2178 CTC-122-02-01 03/13/12 ASTM D2178 CTC-123-02-01 03/13/12 ASTM D4601 CTC-127-02-01 03/13/12 ASTM D6163 CTC-128-02-01 06/11/12 ASTM D6163 CTC-129-02-01 06/11/12 ASTM D6164 CTC-132-02-01 06/11/12 ASTM D6164 CTC-162-02-01 05/09/13 ASTM D6164 CTC-161-02-01 05/09/13 ASTM D6162 CTC-183-02-01 10/02/13 ASTM D6164 CTC-190-02-01 12/02/13 ASTM D1970 CTC-199-02-01 01/22/14 NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 9 of 42 APPROVED ASSEMBLIES: Membrane Type: APP Modified Deck l ype 1I: Wood, Insulated Deck ]Description: 19/32" or greater plywood or wood plank Type A(1): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All G61*ral and System Limitations apply. Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One of more layers of any of the following insulations. Insulation Laver, Insulation Fasteners Fastener Table 3 Densit /ft2/ft' ACFo m-H, Multi -Max FA-3, ENRGY 3, F1intBoard ISO, H-Shield Mini i!m 1.5" thick N/A N/A Note: IAll insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT �nge and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insula ton attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of app oved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used a a top layer placed with the polyisocyanurate side facing down. Base Sheet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Ply Sh et: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS, Glasbase Base Sheet, (Optional) Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base or one or more plies of Flintglas Ply Sheet (Type IV) or Flintglas Premium Ply Sheet (Type VI) adhered in a full I mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass -SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Memb ane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered. Or One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar torch adhered to base or ply sheet. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 10 of 42 Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 11 of 42 Mem 11rane Type: Deck Type 1I: DeckDescription: Systei Type A(2): SBS Modified Wood, Insulated 19/32" or greater plywood or wood plank Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All Goneral and System Limitations apply. Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One of, more layers of any of the following insulations. Insulation Fasteners Fastener Table 3 Density/ft' I, ENRGY 3, ENRGY 3 25 PSI, F1intBoard ISO, H-Shield, FlintBoardH ISO 1.5" thick N/A N/A Appr ed Perlite Insulation Mini 'um'/4" thick N/A N/A ApprJ�I ed High Density Wood Fiberboard Minim'# m %" thick N/A N/A DensDeck, DensDeck Prime Miniifi m 1/4" thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of app roved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used a a top layer placed with the polyisocyanurate side facing down. Base S eet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Option' al) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self - adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 12 of 42 ibrane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply sheet. Bing: Any of the approved surfacing/coating options listed in Table 4. Max} um Design -52.5 psf (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 13 of 42 Deck Type: APP Modified 1I: Wood, Insulated Deck'Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. Syste Type A(3): Anchor sheet mechanically fastened; all layers of insulation adhered with approved asphalt. All General and System Limitations apply. Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One of more layers of any of the following insulations. Insulation Fasteners Fastener Table 3 Density/ft' ACFo m-II, Multi -Max FA-3, ENRGY 3, FlintBoard ISO, H-Shield Minin um 1.5" thick N/A N/A ' I Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT nge and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insula on attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of app, oved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used a',i a top layer placed with the polyisocyanurate side facing down. Base: III One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Ply Sh'bet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Option" al) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or GTA-FR CoolStar torch adhered to base or ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -60 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 14 of 42 brane Type: SBS Modified Type 1I: Wood, Insulated Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c. m Type A(4): Anchor sheet mechanically fastened; all layer of insulation adhered with approved asphalt. All general and System Limitations apply. Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Anchor sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. One Or more layers of any of the following insulations. i Laver Insulation Fasteners Fastener Table 3 Density/ft' H, ENRGY 3, ENRGY 3 25 PSI, F1intBoard ISO, H-Shield, FlintBoardx ISO .1.5" thick N/A N/A Perlite Insulation '/a" thick N/A N/A High Density Wood Fiberboard Vz" thick N/A N/A DensDeck Prime 1/" thick N/A N/A Note: I'All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT nge and at a rate of 20-401bs./100 ft. Please refer to Roofing Application Standard RAS 117 for nsula io n attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of apffoved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used a$ a top layer placed with the polyisocyanurate side facing down. ' Base beet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq I I II I NOA No.: 14-0529.02 M DADECOUNTY • Expiration Date: 06/19/18 Approval Date: 09/24/15 �I Page 15 of 42 Ply Sheet: One ply of All Weather/Empire Base Sheet, Glasbase Base Sheet, Flexiglas Base Sheet, (Optional) Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20- 401bs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch applied. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to base/ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to base/ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -60 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 16 of 42 Me "I brane Type: APP Modified I Dec Type 1I: Wood, Insulated I Dec Description: 15/32" CDX plywood at 24-inch spans attached with #8 screws spaced 6-inch o.c. Sys in Type B(1): Base layer of insulation mechanically fastened, top layer adhered with approved adhesive. I All eneral and System Limitations apply. One r more layers of any of the following insulations. l ISO, ACFoam-II, H-Shield, F1intBoardH ISO 1.5" thick Insulation Fasteners Fastener Table 3 Density/ftz 1 or 3 1:1.33 Note Base layer shall be mechanically attached with fasteners and density described above. Insulation panels liste4iare minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be incre'� sed maintaining the same fastener density (See Roofing Application Standard RAS 117 for fastening l ISO, ACFoam-II, H-Shield, FlintBoardn ISO 1.5" thick Insulation Fasteners Fastener Table 3 Density/ft' N/A N/A Note: Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG 1 Lov Viscosity Insulation Adhesive in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Roofing Avvli I ation Standard RAS 117 for insulation attachment. Basel eet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. I Ply S �et. One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered. I Memb I ane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Any of the approved surfacing/coating options listed in Table 4. Design -67.5 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 17 of 42 I Me brane Type: Dec Type 1I: Dec Description: System Type B(2): APP Modified Wood, Insulated 15/32" CDX plywood at 24-inch spans attached with #8 screws spaced 6-inch o.c. Base layer of insulation mechanically fastened, top layer adhered with approved adhesive. All general and System Limitations apply. One 4r more layers of any of the following insulations. l ISO, ACFoam-II, H-Shield, F1intBoarda ISO 1.5" thick Insulation Fasteners Fastener Table 3 Density/ft' 1 or 3 1:1.33 Note Base layer shall be mechanically attached with fasteners and density described above. Insulation panels liste are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be aining the same fastener density (See Roofing Application Standard RAS 117 for fastening inc4sed maintdetails). . X Gypsum -Fiber Roof Board 1/4" thick Insulation Fasteners Fastener Table 3 Density/ft' N/A N/A Note• Top layer of insulation shall be adhered with Millennium One Step Foamable Adhesive, Millennium PG- 1 Lo• r Viscosity Insulation Adhesive, Insta-Stik Quik Set Insulation Adhesive, OlyBond 500 or OlyBond 500 Green in 3/4" — 1" wide beads spaced 12 inch o.c. Please refer to Roofing Application Standard RAS 117 for insul `ion attachment. Base Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. Ply Sheet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Any of the approved surfacing/coating options listed in Table 4. Design -90 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 18 of 42 Me "brane Type: APP Modified Dec Type 1I: Wood, Insulated Dec Description: 15/32" CDX plywood at 24-inch spans attached with 8 screws spaced 6-inch o.c. Syst m Type C(1): All layers of insulation simultaneously attached. All eneral and System Limitations apply. I One ; r more layers of any of the following insulations. Insulation Fasteners Table 3 1 ISO, ACFoam-II, H-Shield, F1intBoardx ISO 1.5" thick N/A Notejjj All layers shall be simultaneously fastened; see top layer below for fasteners and density. SECT ROCK Gypsum -Fiber Roof Board Mini�um'/4" thick Insulation Fasteners Table 3 1 or 3 Fastener Density/ft2 N/A Fastener Density/ft' 1:1.33 Note:' All layers of insulation shall be mechanically attached using the fastener density listed above. The insul ion panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall ' e increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resist nce in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requi'ements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base $beet: One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. Ply One ply of Flintlastic STA or Flintlastic APP Base T, torch adhered. One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA- FR CoolStar, torch adhered. Any of the approved surfacing/coating options listed in Table 4. Design -67.5 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15. Page 19 of 42 Membrane Type: APP Modified Decl,l Type 1I: Wood, Insulated Dec Description: 15/32° CDX plywood at 24-inch spans attached with #8 screws spaced 6-inch o.c. i Syst m Type C(2): All layers of insulation simultaneously attached. All i eneral and System Limitations apply. One �r more layers of any of the following insulations. Insulation Fasteners Table 3 l ISO, ACFoam-II, H-Shield, F1intBoardx ISO 1.5" thick N/A Notet,J All layers shall be simultaneously fastened; see top layer below for fasteners and density. l ISO, ACFoam-II, H-Shield, F1intBoardx ISO 1.5" thick Insulation Fasteners Table 3 1 or 3 Fastener Density/ftz N/A Fastener Density/ftz 1:1.33 Note4j All layers of insulation shall be mechanically attached using the fastener density listed above. The insul ion panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall a increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resist ' nce in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requi , ements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Base heet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self -adhered. I Ply S et: One or more plies of Flintlastic APP Base T or Flintlastic STA, torch adhered. Mem l, ane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR- or Flintlastic GTA- FR CoolStar, torch adhered. Any of the approved surfacing/coating options listed in Table 4. Design -75.0 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 20 of 42 i Membrane Type: SBS Modified Deck (Type 1: Wood, Non -insulated Deck Ali escription: 15/32" CDX plywood at 24-inch spans attached with 8d ring shank nails spaced 6-inch o.c Systei Type E(1): Base sheet mechanically fastened. All Q peral and System Limitations apply. Base heet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet mechanically attached as detailed below. Su Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR- P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-401bs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf (See General Limitation #9) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 21 of 42 All bran Type: APP Modified Type 1: Wood, Non -insulated Description: 15/32" CDX plywood at 24-inch spans attached with 8d ring shank nails spaced 6-inch o.c m Type E(2): Base sheet mechanically fastened. and System Limitations apply. Sheet: One ply of Flintlastic APP Base T mechanically attached as detailed below. Fastened with Simplex MAXX Cap fasteners spaced 9" o.c. in the 2" side lap and 12" o.c. in two evenly divided, staggered rows in the center of the sheet. One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR- P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-401bs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf (See General Limitation #9) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 22 of 42 I Me bran Type: APP Modified DecL Type 1I: Wood, Non -Insulated Decl� Description: 19/32" or greater plywood or wood plank System Type E(3): Base sheet mechanically fastened. All Cvneral and System Limitations apply. Base (Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fastdhing: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin III caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply S�eet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Op nal) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar torch adhered to base/ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 23 of 42 Mem rane Type: SBS Modified Deck ype 11: Wood, Non -Insulated Deck escription: 19/32" or greater plywood or wood plank Syste Type E(4): Base sheet mechanically fastened. All General and System Limitations apply. Base heet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply S ° eet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Opti nal) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 MIMI-DADE COUNTY . • 1 1 Expiration Date: 06/19/18 III Approval Date: 09/24/15 Page 24 of 42 )rane Type: SBS Modified Type 1I: Wood, Non -Insulated Deck Description: 15/32" CDX plywood at 24-inch spans attached with #8d ring shank nails spaced 6-inch o.c. System Type E(5): Base sheet mechanically fastened. All eneral and System Limitations apply. Bas Sheet: One ply of Glasbase Base Sheet or Yosemite Venting Base Sheet, mechanically attached as described below. Fastened with FBC HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6" o.c. in four, equally spaced staggered center rows. Ply I eet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Op Tonal) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -52.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 25 of 42 i Mem rane Type: APP Modified Deck Type 1I: Wood, Non -Insulated Dec !Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c S Y st Type E : YP O Base sheet mechanical) fastened. Y All C eneral and System Limitations apply. Base sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Fast i ing: Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply S eet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Optional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one ` or more Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic STA or Flintlastic APP Base T torch adhered. Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR or Flintlastic GTA-FR CoolStar torch adhered to base/ply sheet. Any of the approved surfacing/coating options listed in Table 4. m Design -60 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 26 of 42 Me " brane Type: SBS Modified Dec c Type 1I: Wood, Non -Insulated I� Dec i Description: Minimum 19/32" thick plywood attached using approved nails spaced 4" o.c. at wood joists spaced maximum 24" o. c Sys iem Type E( ): Base sheet mechanically fastened. All eneral and System Limitations apply. Bas Sheet: One ply of All Weather/Empire Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase Base Sheet or Flintglas Premium Ply Sheet Type VI mechanically attached as detailed below. Base sheet shall be lapped 4" and fastened with 11 ga. annular ring shank nails and approved tin caps 8"o.c. in the lap and three rows staggered in the center of the sheet 8"o.c. Ply heet: One ply of All Weather/Empire Base Sheet, Flintlastic Ultra Poly SMS Base Sheet, Glasbase (Op ional) Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or one or more plies of Flintglas Ply Sheet Type IV or Flintglas Premium Ply Sheet Type VI adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-401bs./sq. or one ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered or Flintlastic Ultra Poly SMS Base Sheet torch adhered. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -60 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 27 of 42 Mem Deck Deck All ( Sepa (Opt Base Fasts Ply Men Surf (Opt Max Pres ane Type: SBS Modified ype 1: Wood, Non -Insulated ascription: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Type E(8): Base sheet mechanically fastened eral and System Limitations apply. Sheet: One or more layers of Glasbase Base Sheet, loose laid. One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8" o.c. at the 3" lap and 8" o.c. in three, equally spaced center rows. One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self adhered. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 401bs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -60 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 28 of 42 i i � I I Me brane Type: APP Modified Dec k Type 1: Wood, Non -Insulated Dec I Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Sysl I m Type E(9): i Base sheet mechanically fastened I All fieneral and System Limitations apply. Sep ration Sheet: One or more layers of Glasbase Base Sheet, loose laid. (Op iional) Bask, Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Fastening: Anchor sheet shall be fastened with FBC HVHZ nails and tin caps spaced 8" o.c. at the 3" lap and 8" o.c. in three, equally spaced center rows. Ply heet: I One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self adhered. Me brane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Sur cing: Any of the approved surfacing/coating options listed in Table 4. Design -60 psf (See General Limitation #7.) I� NOA No.: 14-0529.02 MIAMI•DADE COUNTY • Expiration Date: 06/19/18 Approval Date: 09/24/15 j Page 29 of 42 i brane Type: SBS Modified Type 1: Wood, Non -Insulated Description: Minimum 19/32" thick plywood attached using 8d ring shank nails spaced 6"o.c. at wood joists spaced maximum 24" o.c. n Type E(10): Base sheet mechanically fastened All eneral and System Limitations apply. Separation Sheet: One or more layers of Glasbase Base Sheet, loose laid. Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. OMG #12 Standard Roofgrip fasteners with OMG 3" Galvanized Steel Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or Flintfast #12 fasteners with Flintfast 3" plates spaced 7" o.c. at the 4" wide laps and 7" o.c. in two, equally spaced staggered center rows. Ply sheet: One ply of Flintlastic Ultra Glass SA, self adhered. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -67.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 30 of 42 i Men brane Type: SBS Modified i Decl Type 1: Wood, Non -Insulated Dech Description: Min 19/32' thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Syst Type E(11): Base sheet mechanically fastened All qeneral and System Limitations apply. Base heet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All Weather/Empire Base Sheet, mechanically attached as described below. Fast ping: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 6 o.c. in four, equally spaced staggered center rows. Ply eet: One ply of Black,Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. men brane: One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Surf cing: Any of the approved surfacing/coating options listed in Table 4. (On U onan Design -82.5 psf (See General Limitation 47.) NOA No.: 14-0529.02 MIAMMADE COUNTY Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 31 of 42 i J Mein i brane Type: APP Modified Dec I Type 1: Wood, Non -Insulated DecR Description: Min "/3? thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Syst I m Type E(12): Base sheet mechanically fastened All i° eneral and System Limitations apply. Bas Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet or All Weather/Empire Base Sheet, mechanically attached as described below. i Fast ning: Anchor sheet shall be fastened with HVHZ nails and tin caps spaced 6" o.c. at the 3" lap and 3 o.c. in four, equally spaced staggered center rows. Ply heet: One ply of Black Diamond Base Sheet, self -adhered. Membrane: Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Suri cing: Any of the approved surfacing/coating options listed in Table 4. MaAmum Design -82.5 psf (See General Limitation #7.) NOA No.: 14-0529.02 MIAMI•DADE COUNTY i . • • • � , Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 32 of 42 I Memb ane Type: SBS Modified Deck rli a 1I: Wood, Non -Insulated Deckcription: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 6-inch o.c. Type E(13): Base sheet mechanically fastened. All General and System Limitations apply. Base Sheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20 or Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center of the sheet. One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Any of the approved surfacing/coating options listed in Table 4. Design -90 psf. (See General Limitation #9) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 33 of 42 All brane Type: APP Modified Type 1I: Wood, Non -Insulated Description: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 6-inch o.c. m Type E(14): Base sheet mechanically fastened. eneral and System Limitations apply. Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in two evenly divided, staggered rows in the center of the sheet. One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar, torch -applied Any of the approved surfacing/coating options listed in Table 4. n Design -90 psf. (See General Limitation #9) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 34 of 42 Meml' ane Type: SBS Modified Deck I ype 1I: Wood, Non -Insulated DeckPescription: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 6-inch o.c. Type E(15): Base sheet mechanically fastened. All G4hi eral and System Limitations apply. Base Iheet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet mechanically attached as described below. Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, F1intFast #12 or F1intFast #14 fasteners with F1intFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in three, equally spaced staggered center rows. Ply Sleet: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Opti nal) Sheet, Flintlastic Base 20, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -97.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 35 of 42 brave Type: SBS Modified Type 1I: Wood, Non -Insulated Description: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 4-inch o.c. m Type E(16): Base sheet mechanically fastened. All general and System Limitations apply. One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexiglas Base Sheet, All Weather / Empire Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divided, staggered rows in the center of the sheet. Ply Sheet: None One ply of Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar adhered to base sheet with approved mopping asphalt applied within the EVT range and at a rate of 20-40 lbs/sq. or one ply of Flintlastic FR Cap 30 T, Flintlastic FR Cap 30 T CoolStar, torch -applied. Any of the approved surfacing/coating options listed in Table 4. Design -105 psf. (See General Limitation #9) NOA l io.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 36 of 42 Me Dei Dei Sys All brane Type: APP Modified Type 1I: Wood, Non -Insulated Description: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 4-inch o.c. m Type E(17): Base sheet mechanically fastened. eneral and System Limitations apply. Sheet: One ply of Flintlastic APP Base T mechanically fastened with Simplex MAXX Cap fasteners spaced 6" o.c. in the 2" side lap and 6" o.c. in three evenly divided, staggered rows in the center of the sheet. Me brane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR, Flintlastic GTA-FR CoolStar, torch -applied Any of the approved surfacing/coating options listed in Table 4. Design -105 psf. (See General Limitation #9) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 37 of 42 i Mem wane Type: SBS Modified Deck l ype 1: Wood, Non -Insulated Deck f Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Type E(18): Base sheet mechanically fastened All General and System Limitations apply. Base heet: One or more layers of Glasbase Base Sheet, .Yosemite Venting Base Sheet, Flexiglas Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Base sheet shall be fastened with OMG 12 Standard Roofgrip fasteners with OMG 3 in. Round Metal Plates or AccuTrac Plates or Trufast #12 DP fasteners with Trufast 3" Metal Insulation Plates or F1intFast #12 Fasteners with FlintFast 3" Insulation Plates spaced 7" o.c. at the 4" lap and 7 o.c. in three, equally spaced center rows. Ply S; eet: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA self -adhered. Su One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic Cap 30, Flintlastic FR Cap 30 or Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -105.0 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 38 of 42 All 1' Q� I Ply P:e brane Type:_ SBS Modified Type 1: Wood, Non -Insulated Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. m Type E(19): Base sheet mechanically fastened eneral and System Limitations apply. •ation Sheet: One ply of Glasbase Base Sheet, loose laid Sheet, Flintlastic Base 20, Flintlastic Poly gMS-Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. Base sheet shall be fastened with FBC HVHZ nails .and tin cn ps spaced 4w o.c.at,the 3' p "'�f,.".: One ply of Black Diamond Base Sheet or Flintlastic Ultra Glass SA, self adhered. OJne ply oFlntlastic G1YIS klintlas�FRDu�aap,!Fftntlastic ar, Flinlasn pr`errui m-GMS Premium GMS CoolStar, Flintlastic FR-P, lintlastic-FR Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStarjlintlastic-Gap 3.0, Cap 30 ox Blintlastic FR CapO CoQlStar adhered-t pbly beet with approved_mo� applied within the:EVT-range-and-at a-rate-of-20-to-40-lbs/sq. or F,.Flintlastic lint astir i Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -105 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 39 of 42 Me "brane Type: APP Modified Deci Type 1: Wood, Non -Insulated Ded Description: Min 19/32" thick plywood at max 24" spans attached 6" o.c. using #8 wood screws. Systi m Type E(20): Base sheet mechanically fastened I All eneral and System Limitations apply. i Sep ation Sheet: One ply of Glasbase Base Sheet, loose laid Bas Sheet: One or more layers of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flexibase Base Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheet, mechanically attached as described below. I Fast ning: Base sheet shall be fastened with FBC HVHZ nails and tin caps spaced 4" o.c. at the 3" lap and 4" o.c. in four, equally spaced center rows Ply heet: One ply of Black Diamond Base Sheet, self adhered. Men brane: One ply of Flintlastic GTA, Flintlastic GTA CoolStar, Flintlastic GTA-FR CoolStar or Flintlastic GTA-FR torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. n Design -105 psf (See General Limitation #7.) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 40 of 42 Type: SBS Modified 1I: Wood, Non -Insulated iption: 15/32" CDX plywood at 24-inch spans attached with #10 wood screws spaced 4-inch o.c. Type E(21): Base sheet mechanically fastened. All I neral and System Limitations apply. Base " heet: One ply of Glasbase Base Sheet, Yosemite Venting Base Sheet, Flintlastic Base 20, Flintlastic III Poly SMS Base Sheet or Flintlastic Ultra Poly SMS Base Sheef mechanically attached as described below. Fastened with Trufast #12 DP Fastener or Trufast #14 HD Fastener with Trufast 3" Metal Insulation Plate, OMG Heavy Duty fasteners with 3 in. Round Metal Plates, OMG AccutTrac Hextra with AccuTrac Flat Bottom plates, FlintFast #12 or FlintFast #14 fasteners with FlintFast 3" Insulation Plates spaced 6" o.c. at the 4" lap and 6" o.c. in four, equally spaced staggered center rows. Ply Sh' et: One or more plies of Glasbase Base Sheet, All Weather/Empire Base Sheet, Flexiglas Base (Optioal) Sheet, Flintlastic Base 20, Flintlastic Poly SMS Base Sheet, Flintlastic Ultra Poly SMS Base Sheet adhered to the base sheet in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. or one or more plies of Flintlastic Base 20 T or Flintlastic Ultra Poly SMS Base Sheet, torch applied. One ply of Flintlastic GMS, Flintlastic GMS CoolStar, Flintlastic Premium GMS, Flintlastic Premium GMS CoolStar, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic FR-P CoolStar, Flintlastic Premium FR-P, Flintlastic Premium FR-P CoolStar, Flintlastic FR Cap 30, Flintlastic FR Cap 30 CoolStar adhered to ply sheet with approved mopping asphalt applied within the EVT range and at a rate of 20 to 40 lbs./sq. or one ply of Flintlastic FR Cap 30 T or Flintlastic FR Cap 30 T CoolStar torch adhered to ply sheet. Any of the approved surfacing/coating options listed in Table 4. Design -127.5 psf. (See General Limitation #7) NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 41 of 42 WOOD DECK SYSTEM LIMITATIONS: slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. LIMITATIONS: 1. ,lire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire atings of this product. 2. 16sulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control �llpproval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the 1 T range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. 11 standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size s I all be 4' x 4' maximum. 4. In overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations hen the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot opping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at e ch side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the s rips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. 1 te: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. F�stener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as toted in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. F��'�tener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fatener resistance value in conjunction with the maximum design value listed within a specific system. Should th ;� fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, pr pared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered R of Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value to en from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application St ' ndard RAS 117. 7. Pe 'meter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener de sities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred wit in this NOA, General Limitation #9 will not be applicable.) 8. Al �Jattachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Robfmg Application Standard RAS 111 and applicable wind load requirements. 9. Th ". maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, pe meters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at ennced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically ref rred within this NOA, General Limitation #7 will not be applicable.) 10. All roducts listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Ruli 61G20-3 of the Florida Administrative Code. 1I END OF THIS ACCEPTANCE NOA No.: 14-0529.02 Expiration Date: 06/19/18 Approval Date: 09/24/15 Page 42 of 42