Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL EXTERIOR DOORSBuilding Code Online COr ,:viva :Y Page 1 of 5 Product Manufacturer �PlastprorIne /�NanyaYP.lastics Corp. Address/Phone/Email 5200 W CENTURY BLVD. LOS ANGELES, CA 90045 (440)96b-9773 Ext16 rickw@rwbldgconsultants.com Authorized Signature Vivian Wright rickw@rwbldgconsultants.com Technical Representative Scott Johnson Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440)969-9773 Ext18 scottjohnson@plastproinc.com Quality Assurance Representative Ron O'Connell Address/Phone/Email 5200 W Century Blvd. Los Angeles, CA 90045 (440) 969-9773 Ext16 ronoconnell@plastpro.com Category E-zterior Doors Subcategory Swinging Exterior Door Assemblies` Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Lyndon F. Schmidt, P.E. the Evaluation Report Florida License PE-43409 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Ryan J. King, P.E. Validation Checklist -Hardcopy Received Certificate of Independence FL15213 R3 COI jbj Certificate of Independence.pdf Referenced Standard and Year (of Standard) Standard Year 101/I.S.2 1997 101/I.S.2/NAFS 2002 AAMA/WDMA/CSA101/I.S.2/A440 2005 ASTM E1886 2002 ASTM E1996 2002 ASTM E330 2002 TAS 201, 202, 203 1994 Mps://w111.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZ 1 Q... 7/16/2018 Building Code Online Page 2 of 5 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL15213 R3 EQUIV (aa) Eouivalency of Standards.pdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/20/2017 Date Validated 10/20/2017 Date Pending FBC Approval 10/24/2017 Date Approved 12/12/2017 ' Summary of Products Go to Page 10 d id Page 1 / 2 FL # Model, Number or Name Description Ell 52.13.1 a. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door - Grain/Rustic/Mahogany Series Inswing/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.1.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.1 for Design Pressure Ratings, any FL15213 R3 AE (a) Eva[ 15213.1.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.2 b. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series Fiberglass Door 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.2.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.2 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.2.pcif additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.3 c. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO - Fiberglass Door Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.3.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Thir&Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.3 for Design Pressure Ratings, any FLIS213 R3 AE (a) Eval 15213.3.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.4 d. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Lip Lite" Glazing - Inswing/Outswing (OX or. Fiberglass Door Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.4.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.4 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.4.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.5 e. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Single Door with Sidelites Grain/Rustic/Mahogany Series utilizing "Lip Lite" Glazing - Inswing/Outswing (OXO - Fiberglass Door Configuration) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Installation Instructions FL15213 R3 II (a) Inst 15213.5.pcif Verified By: Lyndon F. Schmidt, P.E. 43409 Created by Independent Third Party: Yes https://ww�.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yVVKJZI Q... 7/16/2018 Building Code Online Page 3 of 5 https:/, Design Pressure: N/A I Evaluation Reports Other: See INST 15213.5 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.5.pdf additional use limitations, installation instructions and product Created by Independent.Third Party: Yes particulars. 15213.6 f. Smooth/Wood Grain/White Wood 6'8 "Impact" Opaque Fiberglass Double Door - Grain/Rustic/Mahogany Series Inswing/Outswing (XX - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.6.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.6 for Design Pressure Ratings, any PL15213 R3 AE (a) Eva[ 15213.6.Ddf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.7 g. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series Fiberglass Door 6'8 "Impact" Opaque Fiberglass Double Door with Sidelites utilizing "Snap Frame" Glazing - Inswing/Outswing (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.7.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.7 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.7.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.8 h. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series Fiberglass Door 6'8 "Impa.ct" Opaque Fiberglass Double Door with Sidelites utilizing "Lip Lite" Glazing - Inswing/Outswing (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.8 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213,8.1)df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.9 [. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series Fiberglass Door 6'8 "Non Impact" Glazed Fiberglass Single Door utilizing "Snap Frame" Glazing Inswing/Outswing (X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 I1 (a) Inst 15213.9.Ddf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.9 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.9.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.10 j. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO Fiberglass Door - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.10.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.10 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.10.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.11 k. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelites utilizing "Snap Frame" Glazing - Inswing/Outswing (OXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 11 (a) Inst 15213.11.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.11 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.11.1)df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.12 I. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Double Door utilizing Grain/Rustic/Mahogany Series N "Snap Frame" Glazing - Inswing/Outswing (XX - Fiberglass Door Configuration) .floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 Q... 7/16/2018 Building Code Online Page 4 of 5 Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.12.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.12 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.12.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.13 m. Smooth/Wood Grain/White Wood 6'8 "Non -Impact" Glazed Fiberglass Double Door with Grain/Rustic/Mahogany Series N Sidelites utilizing "Snap Frame" Glazing - Inswing/Outswing Fiberglass Door (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 I1 (a) Inst 15213.13.odf ' Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.13 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.13.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.14 n. Smooth/Wood Grain/White."Wood Grain/Rustic/Mahogany Series N Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Single Door utilizing "Lip Lite" Glazing - Inswing/Outswing (X - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213,14,ocif Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.14 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.14.1)df additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.15 o. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series N Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelite utilizing "Lip Lite" Glazing - Inswing/Outswing (OX or XO - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.15.odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.15 for Design Pressure Ratings, any FL15213 R3 AE (a) Eva[ 15213.15.0clf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.16 p. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series N Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Single Door with Sidelites utilizing "Lip Lite" Glazing - Inswing/Outswing (OXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 I1 (a) Inst 15213.16.12df Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.16 for Design Pressure Ratings, any FL15213 R3 AE (a) Eva[ 15213.16.0f additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.17 q. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series N Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Double Door utilizing "Lip Lite" Glazing - Inswing/Outswing (XX - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.17.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: See INST 15213.17 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213,17,odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.18 r. Smooth/Wood Grain/White Wood Grain/Rustic/Mahogany Series N Fiberglass Door 6'8 "Non -Impact" Glazed Fiberglass Double Door with Sidelites utilizing "Lip Lite" Glazing - Inswing/Outswing (OXXO - Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.18,odf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.18 for Design Pressure Ratings, any FL15213 R3 AE (a) Eva[ 15213.18.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. https://ww}',r.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv3yV VKJZ 1 Q... 7/16/2018 t i . Flor da Building Code Online • . Page 5 of 5 15213.19 s. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door - Grain/Rustic/Mahogany Series N Inswing/Outswing (X - Configuration) Fiberglass Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 II (a) Inst 15213.19.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E. 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.19 for'Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.19.pdf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. 15213.20 t. Smooth/Wood Grain/White Wood 8'0 "Impact" Opaque Fiberglass Single Door with Sidelite Grain/Rustic/Mahogany Series N utilizing "Snap Frame" Glazing - Inswing/Outswing (OX or XO Fiberglass Door - Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15213 R3 I1 (a) Inst 15213.20:pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E, 43409 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: INST 15213.20 for Design Pressure Ratings, any FL15213 R3 AE (a) Eval 15213.20.odf additional use limitations, installation instructions and product Created by Independent Third Party: Yes particulars. Go to Page D id Pagel/ 20 0 I Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlc-records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 1'g W] 'iagg ECheck ®+�. Credit Card Safe Ittps:// floridabuilding.org/pr/P_app_dti.aspx?param--wGEVXQwtDgv3yVVKJZ1Q... 7/16/2018 5200 W. CENTURY BLVD. LOS ANOELES, CA 90045 Smooth / Wood Grain / White Wood Grain Rustic / Mahogany Series Fiberglass Door INSWING / OUTSWING "IMPACP` GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBq structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shag be beyond wall dressing or stucco.. 3. When used in areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2 &.R301.2.1.2 and does not require an impact resistant covering. This product meets missile level'U' and includes Wind Zone 4 as defined in ASTM El996 and FBC Sections 1607.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5, Site conditions that deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. TABLE OF CONTENTS $HEET 0 DESCRIP110N 1 Typical elevation, design pressures, & general notes 2 Door panel details. 3 Horizontal cross sections 4 . Vertical cross sections 5 Buck and frame anchoring- 2X buck masonry construction 6 Frame anchoring -1 X buck masonry construction 7 Big of materials & components 37 57' MAX. O.A. FRAME WIDTH z z 3 o w w v n 0 0 OVERALL � DESIGN PRESSt1RE (PSF)'. � SWING FRAME_ . ,DIMENStO[V POSITIVE TfEGdT1VE ; INSWING 37.50" x 82.00" +65.0 -70.0 OUTSWING 37.5&' x 80.37" +65.0 -65.0 v P;,�U ro 9'. _? n a:�=T z 4�p% to 1111 *Ilia mo a n cao ug �mc a V 0 �01 I Iz ^ a w z Z3 Z NZ [a1 -E.- 02/16/12, _ saaL: N.T.S. a 5 MG. BY. JK m erne. Dr: LFS 3 DR4WIM' rJa.: �' FL— 15213,1 0 SHEET 1 OFL N aJ R:\Oients\Plastpro, Inc PERMANENTA - Florida Product Approvals\FL-15213 Fiberglass Door - Inswing-Outswing\C - Drawings\FL 15213 (2017)\FL-15213.1-.8dwg, 2.1 79.25' MAX. DOOR PANEL HEIGHT N � I O = v Zoe" _ m � = I Q •O Ili 1.20" � N O I I 00 0 �. M o a 29 I 0 p o , T ! no I z o >r OA N I O O o , • I I �z 1 1 sz it <w n II II 3a Z m m 0 A 0 .,` v•��ycenleF••.r ., / No.43409 G =*' k October 19, 2017 PRODUCT: Document. Prepared Ely: ; Lyndon F. SchmidtLASTPR��j�••• G O )DOOR �� P.E. No. 43409 FlBERCLA NALI PART OR ASSEMBLY: /{�,,1I� BUILDING CONSULTANTS, INC. DOOR PANEL DETAILS d 1iY4 P.O. Box 230, VoIrlco, FL 33595 Phone No.: 813.659.9197 m A -n � I� N N Cn W T V N 2 10 19 17 UPDATE TO 6TH ED. (2017 FBC LFS 1 04 22 15 UPDATE TO 5TH ED. (2014) FBC JK NO DATE BY 0 2072 R.W. BUILDING CONGUL-M INC. R:\Clients\Plastpro, Inc PERMANENT\A - Florida Product Approvals\FL-15213 Fiberglass Door - Inswing-Outswing\C - Drawings\FL 15213 (2017)\FL-152131-.8.dwg, 3.1 I O A .91 m O ono CR0 L rr-- y5y' A 3 N rn n 0 z r o w I N W y ;R in V � N z O a 2 10 19 17 UPDATE TO 6TH ED. 2077 FBC LFS 1 04122175 UPDATE'TO 5TH ED. (2014 FBC JK NO DATE BY w .00, V A �z ttt1111111� SCPiIbJjO ����i uc¢rleF'•. A •� No.43409 October 19, 2017 PRODUCT: Document. Prepared By;- , ; ��j's.S1• �0 ���'••• PLASTPRO INC. Lyndon F. Schmidt P.E. No. 43409 .� FIBERGLASS DOOR �$/ �AL` !!!llllltlt� PART OR ASSEMBLY: m �/t-/�� BUILDING CONSULTANTS, INC. HORIZONTAL CROSS SECTIONS d l vV P•0• Box 230, Voirtco, FL 33595 Phone No.: 813.659.9197 i 2012 R.W. BUILCIN0 CONauLTAN" INC. R'\Clients\Plastpro, Inc PERMANENT\A - Florida Product Approvals\FL-15213 Fiberglass Door -inswing-Ounwing\C - Drawings\FL 15213 (2017)\FL-15213.1-.8.dwg, 4.1 41 r N u � xtn\ V N m 2 rn O a m a O a M O a 0 a 2 10 1977 UPDATE TO 6TH ED. (2017 FBC LFS 1 04 22 15 UPOATE TO 5TH ED. (2014) FBC JK NO DATE BY M m a 09 O a 0 s M !t7 1 0 Sy z O PC 0.19' CSINK (7P-) m AN X rn a X� X^ c n Y- 0 Cr �y M n z Z M O a 1-1/4.'MIN. EMB. (TYP.) 1-i/4"MIN. EMS. (TYP.) `ttttlltlll7j7 / No.43409 October 19, 2017 DUCT: Doeumentn Proparotl Br. 1W. ��j••• ���'�� • ``��` PLASTPRO I Lyndon F. Schmidt P.E. No. 43409 FIBERGLASS OR " OR ASSEMBLY: /t- BUILDING CONSULTANTS, INC. VERTICAL CROSS SECTIONS r! liW P.O. Box 230, Valr)co, FL 33595 Phone No.: 813.659.9197 FSPE C.A. No. 9813 ) 2072 R.W. BUILDING CONSULTANTS INC. 9 6 1 TYP. HEAD & JAMBS to 2X BUCK MASONRY—\ OPENING � z 0 BUCK ANCHORING HINGE JAMB CONCRETE ANCHOR NOTES: I Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarlofnis. 2. Concrete anchor locations noted as "MAX. ON CENTER" must be adjusted to maintain the min. edge distance to mortar joints, additional concrete anchors may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: ' "MI . ... .... NCANCR MIN;C-L..E..AR..A. TYPE -SIZE, TO . ... .. .E .... ... .............. ...... . .. ............ ..... . . ............. :EDGE ITW 2" 4" —TAPCON ELCO 1/4" 1-1/4" 4" ULTRACON WOOD SCREW INSTALLATION NOTES: Ill 1. Maintain a minimum 5/8"edge distance, I" end distance, B, I" o.c. spacing of wood screws to prevent the spriffing of wood. 2X BUCK FRAME MASONRY OPENING FRAME -HORING 'Mo7s—ort(y-'2X burk-cWrfS1rUCCCCC-----fi HINGEJAMS 46 W ,!� .... .el ...... .. To ZOO, �4 11 t� 31 R. - 2 z $ 0 CM E 07 M in a.E o E* -Z 6 0 0 C IJ 0 C-) cc 0 0 X (n Et as m In Ic 0 L) r�c ) M STRIKE JAMB STRIKE PLATE DETAIL "El I 1 =1 6 z o z E.- 02/16/12 'z M- N.T.S. BY.- JK M --ur. LFS i5y No.: Ir W FL-15213.1 rr 5 of 7 Y-1 1-1 6" �o 30 T4YP.HEVAD & JAMBS Ix J BUCK ;o FRAME—'\, MASONRY— U z OPENING z 0 HINGE JAMS r* fRAMEANCHORiNG A 'K4 nry1X.6-ucICc-"s ction CONCRETE ANCHOR NOTES: 1. Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortarldints. 2. Concrete anchor locations noted as "MAX ON CENTER" must be adjusted to maintain the min. edge distance to mortarjoints, additional concrete anchors 'may be required to ensure the "MAX. ON CENTER" dimension are not exceeded. 3. Concrete anchor table: N,CLEARANCE ............. .. .... .".... .... TYP ........ ................ .imirbmiNv-TONIASONRY �.. -M,,.- DJACE..M .......... .. ....ANCHOR ............ ... ............ ....I I....................................... . .... ... Afft.......�... ITW ® TAPCON 1/4- 11-1/4" 2' 4" ELCO 114- 1.114, 1. Ir ULTRAC00 ITW . I 3/16--f 1-1/4. 3. I 1-1/2, 1CO WOOD SCREW INSTALLATION NOTES: 1. Maintain a minimum 516'edge distance, l"end distance, & 1"O.c. spacing of wood screws to prevent the splitting of wood. STRIKE JAMS HINGE JAMS STRIKE PLATE DETAIL a, 21, Z* 0 Z, E C; 'o 9 [L 5 q O M IL a, E Cg �A -�-a: 9 0 ot: Up C,Z Op OEO Ke u, :Co EnCD .51 W 1: rL Ca 0 0 z ZD z d 121 1 i Z 13 a DATE- 02/16/12 SCALE N.T.S. I MS. ffy., JK F5 CHK. BY.. LFS NO.: IMMIX 213.1 1SHEET _6_ V 7 -- -BiLL0f-MA7ERlAM-- ITEM -DESCRIPTION MATERIAL I MASONRY - 3.000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 2 1 X BUCK SG >= 0.55 WOOD 3 2X BUCK SG >= 0.55 WOOD 4 1 /4" MAX. SHIM SPACE - 5 1 /4" X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 6 #10x2-1/2" PFH WOOD SCREW 1.IS MIN. EMBEDMENT STEEL 8 119 x3/4" PFH WOOD SCREW STEEL 9 DOOR SKIN MIN. 0.075" THICK FIBERGLASS 10 INSWING VINYL DOOR BOTTOM SWEEP BY ENDURA VINYL 10A VINYL DOOR BOTTOM SWEEP #3628 BY HOLM IND. VINYL 1 I REINFORCEMENT WOOD FOR LOCK WOOD 12 FINGER JOINTED PINE JAMB WOOD 13 #9 x 2-1 /4' PFH WOOD SCREW STEEL 14 BOTTOM RAIL CELLULAR PVC 15 INSWING ADJUSTABLE THRESHOLD BY ENDURA ALUM. / WOOD 15A INSWING ADJUSTABLE ALUMINUM THRESHOLD BY DLP ALUM. / WOOD 16 FORCE 5 WEATHER STRIPPING BY ENDURA FOAM 16A COMPRESSION WEATHER STRIP QLON 650 BY SCHLEGEL FOAM 17 KWIKSET KEYED ENTRY - SIGNATURE SERIES STEEL 18 KWIKSETDEADBOLT- SIGNATURE SERIES 780 STEEL 20 POLYURETHANE FOAM BY NANYA POLYURETHANE 21 4" x 4" BUTT HINGE STEEL 23 POLY FIBER JAMB COMP. / VINYL 24 HINGE & LATCH STILE CELLULAR PVC 25 1 TOP RAIL CELLULAR PVC 26 DEADBOLT STRIKE PLATE STEEL 27 LATCH STRIKE PLATE STEEL 28 OUTSWING BUMP THRESHOLD ALUM. / WOOD 29 HINGE & LATCH STILE REINFORCEMENT LVL 30 1 /4" X 3-3/4" PFH TIW CONCRETE SCREW STEEL 31 #9 x l" PFH WOOD SCREW STEEL 32 1 /4" x 3-1 /4" PFH ITW CONCRETE SCREW STEEL 33 3/16" X 3-1/4" PFH ITW CONCRETE SCREW STEEL 40 1 DOOR PANEL- SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS 4.56" — 2.43' --i T2 JAMB 15A ADJUSTABLE INSWING SILL N 4.56"��N6 8 Ea °g m m 9 0 0 mda E `o= 2.17 2.43" —►{ 23 POLY FBER JAMB 4.56" ^{ T �OUTSWING BUMP iHRESHOLDBUMP THRESHOLD LE, N.T.S. �. BY. JK BY: LFS h9NO NO.: FL-15273.1 1 7 OF 7