HomeMy WebLinkAboutCARPORT SPECIFICATIONS9m,
ALWAIN"UIVI UEN DESIGNI-1�ti �
Constru.cti.on Eng.in:eering -
*Ptan Try Yp e
❑ creen Room/Sun Room/Fill In
❑ ool Screen/Cage (Non -Removable Screen — Designed to withstand actual Wind Speed)
0 1 ar Port
❑ atio Cover
❑ , ther:
*d,ontractor Name: Master Craft Aluminum Products
*Address: 1634 SE Niemeyer Cir
* ty: Port St Lucie
* I' `�
ip Code: 34952
* hone/Fax: 772-335-1177
*
mail: mastercraftaluminum@gmail.co
* hoose One:O Mail ❑ Pick Up ❑ E-File ❑Fed Ex* 2 No of Copies
tg
For FedEx option go to www.aluminumscreendesi ng com and provide FedEx account #)
ayment ❑Check Credit Card
-(For Credit Card option go to www.aluminumscreendesign.com to pay by credit card)
E ineeringg prepared by:
Engineer: Michael Thompson, MSc, P.E. (P.E. # 47509)
4401 Vineland Road- Suite A6 Orlando, FL 32811 `
Office:407-734-1470 Cell: 407-721-2292
Project Manager Paul Thomas 386-479-9504 Fax: 888-923-8181
Email: aluminumscreendesigneyahoo.com
Webslte: www.aluminumscreendesign.Com CA#30930
U nsulated "Pan Roof
❑ utter ❑Fascia ❑Block wall ❑Conventional Wall ❑ 4' Wall
Uprights X Top Plate X Kick Plate
ra �_Screen��age
❑ ome ❑ Gable ❑ Mansard ❑ Shed/Slope
❑ Gutter ❑Fascia ❑Block Wall ❑ Conventional Wall
B aims X Uprights X Purlin X Kick Plate
Insulated ❑ Pan Roof
Gutter ❑Fascia ❑Block wall ❑Conventional Wall 0 0 Wall
ams 2 X 6 Post 3 X 3
Insulated ❑Pan Roof
Gutter ❑Fascia ❑Block Wall ❑Conventional Wall ❑ O Wall
ams X Post X
Existing ❑ New: 4"Slab ❑Pier ❑Ribbon Footer X
Pavers ❑6" Thickened Edge
e: In the event that there is a conflict with the design plans and general notes and design standard, the contractor
II utilize the more stringent dimensions and member sizes prior to ordering materials, fabrication and/or
struction between the plans and the general notes and design standard.
gineer: Michael Thompson, MSc, P.E. (PE#47509)
)1 Vineland Road Suite A6, Orlando, FL 32811
%#309301-Ph 407-734-1470/Fax 407-734-1790
ALUMINUM SCREEN DESIGN
IBM lum'; ` A S DA I . uminum' P. Consiruttiun En:glnee.ring y,
General Notes & Design Standards
(Unscreened Patio Room Enclosure) -
The following are general design standards. More stringent design standards may be noted on the plans —In the event
of a conflict in plans and/or design standard dimensions and/or member sizes, the contractor must utilize the more
stringent dimensions and/or member sizes prior to ordering materials, fabrication and/or construction.
Design Codes:
Florida Building Code 2017 (61 Edition)
Aluminum Design Manual 2015
ASCE 7-10
Design Loads:
Pursuant to FBC Chapters 16 & 20
Ultimate Wind: -150 MPH (FBC Table 2002.4) (45 ps,)
Risk Category: -See attach site specific plan sheet (FBC Table 1604.5)
Exposure Category: -See attach site specific plan sheet (FBC 1609.4.3)
Additional Load requirements:
Structural members supporting screened enclosures are designed for wind in both of two orthogonal directions using
the pressures given in Table 2002.4. Each primary member is also designed for a 300 pound load applied vertically
downward along any 1 foot of any member, not occurring simultaneously with wind load. In addition to wind
pressures, purlins is also be designed for a 200 pound load applied vertically downward along any 1 foot of any
member, not occurring simultaneously with wind load.
Design Basis:
Allowable Stress Design (ASD) =Allowable Strength Design (ASD) divide by safety factor
General Requirements:
Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies acceptance of
information shown as correct and obligates himself to any expense, real or implied, arising from their use.
A change to the structural drawings due to the acceptance of alternates and/or substitutes is the responsibility of the
contractor and must be submitted to the engineer for approval.
The general contractor and each subcontractor shall review the approve construction plans in its entirety and verify
all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or
structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans
prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the
review and approval from the, designer and/or structural engineer. Then designer and/or structural engineer shall
bear no responsibility or liability for the construction of premises and accuracy of the drawings.
Foundation and Earthwork:
Applicable only when unsuitable soils are encountered.
When unsuitable soils are encountered as specified bearing strata, notify owner's representative/engineer.
Soil bearing capacity — 2,000 psf Minimum
Provide neat excavation for footing and place concrete immediately after excavation and inspection.
Pump water from footing excavation if greater than one inch.
Compact all fill to 95% ASTM D698 density.
Unit soil weight = 105 pcf
Internal angle of friction = 30 degrees
Coeff. Of friction between footing and soil = 0.5
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
MEASDALUMINUM SCREEN DESIGN
A?umindrn & Consiruciicn £n.ginee.r?ng
Structural Aluminum: Q
Conform to latest edition of Florida Building Code and Aluminum Design Manual standard practice for`aluminum
design. I e
All aluminum shall be 6005-T5 (E=10,000 ksi; Fy = 35 ksi) with a minimum wall thickness of 0.046"
Splicing prohibited without prior approval as to location and type.
Burning of holes in aluminum members is prohibited. Any member with burned holes must be replaced.
Aluminum Protection:
Shall be pursuant FBC 2003.8.4. Aluminum surfaces in contact with dissimilar materials, lime -mortar, concrete, or
other masonry materials, shall be protected with powder coated or ESP paint or alkali -resistant coatings, such as
heavy -bodied bituminous paint or water -white methacrylate lacquer.
Screws:
Aluminum self -tapping screws shall conform to ASME B 18.6.4 specification.
Self -tapping screws shall meet the requirements of ADM J.5
Maximum fastener spacing shall not exceed (3+20t) where "t" is the member thickness in inches.
For roofing and siding connection, use minimum #12 screws for end and side laps spaced at 12" max for side lap
and end lap fasteners shall be no more than 2" from the end of overlapping sheets.
For bottom plate and column base, secure with '/4" tapcons a minimum embedment of 1 1/8" and 2 '/4" respectively
into concrete footer.
Bolts:
Bolts and other fasteners shall be aluminum, stainless steel, hot -dip or electro-galvanized steel. Double cadmium
plated steel bolts may also be used. Bolt holes diameter shall not exceed 1/16" larger than the bolt diameter and shall
be spaced at a minimum of 2.5 times the bolt diameter with minimum edge distance of 1.5 times the bolt diameter.
Bolts shall meet the requirements of ADM J.3
Concrete
Conform to ACI 318, latest edition and ACI 301
Compressive Ultimate Strength (Minimum at 28 days) shall be 3000 psi
Exposed chamfer edges shall be 3/4"
Reinforcing Steel:
Conform to ACI 318 and 315, Latest edition
All reinforcement steel shall be ASTM A615 Grade 60.
Smooth dowels & ties shall be ASTM A185
Welded Wire Fabric shall be ASTM A185 or A82 (Flat sheet).
Deformed bar anchors shall be ASTM A496, Grade 70
Cover: Footing 3"
Washer:
Washers shall be used under bolt heads and under nuts.
Hole Alignment:
Poor matching holes must be rejected. Contractor shall prevent holes from drifting and distort the metal. All chips
and foreign matter between contacting surfaces shall be removed before assembly.
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
ASALUMINUty"i SCREEN DESIGN
Nvrninum & Consirut:tf.en Engineering
Beams & Uprights: In the event of a conflict with the values in this table and the site specific plan, the contractor must utilize the more
stringent dimensions and/or member sizes between the site specific plan and the below applicable span limitations
prior to ordering materials, fabrication and/or construction.
150 MPH
PRIMARY HEADER BEAM MEMBERS -OPEN COVERED PATIO -(No Screen Insert)
SIZE
3" Pan Roof Span
Maximum Roof Span
= 6'-0"
3" Pan Roof Span
Maximum Roof Span
= 81-0"
3" Pan Roof Span
Maximum Roof Span =10`
0"
3" Pan Roof Span
Maximum Roof
Span=12'-0"
3" Pan Roof Span
Maximum Roof Span =
15'-0"
2 X 4
9'-0"
9'-0"
8'-0"
7'-0"
7'-0"
2 X 5
12--0"
111-0"
10'-0"
9'-0"
8'-0"
2 X 6
13'-0"
121-0"
11'-0"
11'-0"
10`-0"
2 X 7
15'-0"
14'-0"
1,3'-0"
12'-0"
11'-0"
2 X 8
15'-0" *
151-0"
15'-0"
15'-0"
13`-0"
2 X 9
15'-0" *
15'-0" *
15'-0'" *
15'-0"
F2 X 10
15'-0" *
IV-0" *
15'-0" *
15'-01,
Wumn size is 3 x 3 x 0M5" (11V) unless noted otherwise with a max height of 9'-0" '(CSR) control < 1A Largerspan req larger column size.
Knee Bracing:
Contractor shall provide knee bracing on 45 degree angle pursuant the attach detail sheet that specified size and
length requirements. Knee bracing on upright above super gutter intersection shall be connected to upright no more
than 6" above the super gutter. Knee brace size shall be a minimum of 2 x 2 for beam span of 15' max; 2 x 3 for 30'
max; 2 x 4 for beam span greater than 30'.
Intermediate/Header Beam:
Contractor is required to install a minimum 2 x 7 intermediate header beam supported with 3 x 3 column spaced at
10 feet (max) when insulated roof span exceeds 15 feet.
Patio Cover-
Contractor is required to install insulated roof covering pursuant to the Florida product approval specification.
Overhang shall be a maximum of F-0" along the side, 3'-0" along the front and 1/2" along the front interface
between the super gutter and the attached pool cage knee riser wall. Maximum deflection shall be limited to L/80.
Edge Distance:
Contractor is required to install uprights to provide a 2" minimum clearance from edge of slab and/or footer.
Michael Thompson, P.E. #47509/CA#30930
4401 Vineland Road., Suite A6, Orlando, FL 32811. (P) 407-734-1470 (F) 407-734-1790
www.aluminumscreendesign.com
In the event of a conflict in member sizes shown on
the plans and the general notes, the contractor must
utilize the more stringent member size requirements. -
Engineer: Michael Tompson, P.E. 47509/CA30930
Swart
o Str tur
36 Alta Loma
' Port St Lucie, 34952
150 MPH Exp B
2x6FauthVW1 Eba,i 2x6 Ftxr hXAMIEba. Installing a 28 x 12 carport
on the side of the home.
Roo_ f Type The structure
_� will have a 4th wall. `
1: Monoslope Tx 1 T x 4' x .024 Composite Roof Panels 71z
2. Roof Material; V x 41 x .n9e Elite 2000 The concrete is exsitng.
Composite Panel, 1 #density foam,
Florida product approval FL 7561-R4 2 x 6 SMB
a,. II B4'�
Fountdation II 2VT
Exisitng Concrete. No additional concrete footing
or slab is required to resist the. loads imposed by
the proposed construction if the existing slab is (5) 914 x 4" lags w/ a 1-1/2" neoprene
(4) 3/8" x 4" thru bolts w/1" washer per panel
in sound condition. waghprsq
Load Criteria
150 MPH Exp B
Category 1- Carport Non -Habitable
2x6SMB
2x6
Al self mating beam sections
W are to be stitched with #12 screws
W
Xx
6" from the ends and 127 center to
x 2 x 3 x.aso knee brace for X
W
W Center.
W edge beam end fourth wall beam
W
x
X
X 1-Wx2-116'x 1-11T x.06o
X
O
C wl (3) 012 x.on bolh aides
Q
SNp
to
N
tD and (3) #12 x 3r4' into the post b
N N
C
C
C
a
�
� 7
2 x 2 x 3 x .125 Angles w/ 3/8" Concrete
Fasteners (2-114' Embedment) w/
on either side of the upright w/
(2) 318" thru bolts
Header Attachment to Fascia