HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVIT'
L.Y
Ey1ditI Permit #
P/l
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name
Applicant:
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
+32.37/-42.62
+50/-60 DP
Ply Gem
Series 4712 Flange
FL 14039.1
Non -Impact
910 Wood Screw with sufficient length to achieve 1-1/4'embedment. Required anchors: Head (3). Jamb (3)
Mullions
N/A
+/-75 DP
Ply Gem
Series 4700 Flange
FL 15264.2
N/A
UseY..'Tapcon with sufficient length to achieve a l Y.' minimum embedment with 2 Wminimum edge distance.
Fixed Glass
+29.65/38.87
+/-55 DP
Ply Gem
Series 4701 Flange
FL 14434.1
Non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4' embedment. Required anchors: Head (3), Jamb (3)
Block Glass
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Skylights
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Sliding Glass Doors
+28.74/-42.62
+/-50 DP
Ply Gem
Series 4780
FL 14634.2
Non -Impact
3/16'Tapcon with sufficient length to achieve 1414-embedment. Required anchors: Head/Sill(6). Jamb(5) Each window.
Swing Type Doors
+30.64/-30.64
+67.0/-67.0
ThermaTru
3'0'R6'0' Smooth Star Rberglass
FL5891.5
N/A
MTepcon'/7, Min Embedment l-Ile,Mln Clearenm to edge Y. Mln Clearance to adjacent enchore; OR ELCO Tepcm 1/4'. Mn
French Doors
N/A
N/A
N/A
N/A
N/A
N/A
I N/A
Garage Doors
+25.91/-31.39
+36/-42
Clopay
16X7 Model 73W6
FL16546.4
N/A
Jamb to block onvertimijambl/4'X11/4'minembeddedTapmn.Maxspacirg0712'andI-ODsteelmatterrequired.
Hurricane Protection
N/A
+40/-40
Eastern Metal Supply
24ga Steel Panels
FL 11964.2
N/A
1/4" Tapcon Anchors, SG Tapcons or 1/4" X 3/4". All points Solid -set Anchors.
Roof Ventilation
N/A
Roofing Material
N/A
N/A
Tamko
N/A
FL18355.1
N/A
e nails per shingle. Standard type roofng nail, nail shanks should be 12 gauge wire and minimum heed or 3180.
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this
wind loads and forces specified by current code provisions.
Name: JAMES JOSEPH CANTWELL
Design Prof.
Signature:
ARCHITECT Cert. No. AR001207
These products provide adequate resistance to the
Date: 06/26/18
seal
FILE COPY