Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEle Y i i BY ORM R405-2017 St Lu c'opint1" LORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Meth" d oject Name: WERT- RUIZ'RESIDENCE Builder Name: tr sett 220.OLSON AVENUE Permit Office: ST LUCIE COUNTY lity, State, Zip: FORT PIERCE, :FL , Permit Number. wner. Jurisdiction: ign Location:, FL, Fort Pierce county:. St. Lucie.(Fiorids Climate Zone 2 ) 1. • ew construction or existing New (From Plans) 9. Wall Types (1216.0 sgft,) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - ExOnsul, Exterior 13=4.1 1216.00'ft2 3. umber of units, if multiple family1 b, N/A R= ft2 c: N/A R= ftZ 4.: umber of Bedrooms 3 d. N/A R= ftz 5. this a worst case? No 10: Ceiling Types (1257.0 . gft;j Insulation Area 6. 3onclitioned floor area above grade (ftz) 1257 a: Under Attic (Vented)` R=30.0 1257.00 ftz b. N/A R= ftz onditioned floor area below grade (ft2). 0 c. N/A R= ftz 7. I indows (90.0 sgft,) Description Area 11. Ducts R ftz a. Sup: Attic, Ret: Attic, AH: UTILITY 6 125 U-Factor: Sgl, U=0.30 75.00 ftz SHGC: SHGC=0.21 U-Factor: SO, U ;0.32 15.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC.=0.25 a. Central Unit 24.0 SEER:16.00 U-Factor: N/A ftz 'I ck SHGC: U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a, Electric Strip Heat 17.0 COP:1.00 rea Weighted Average Overhang Depth: 1.333 ft. rea Weighted Average SHGC: 0,217 14. Hot water systems, 8. loorTypes (1257.0 sgft.) Insulation Area a. Electric Cap: 40 gallons Slab -On -Grade Edge Insulation R=0.0 1257.00 ftz NIA EF: 0.980 b. Conservation features I R- ft z N/A None R= ftz 15. Credits None GI Total Proposed Modified Loads: 42.86 s/Floor Area: 0.072 PAS S Total Baseline Loads: 45.75 I hE this i i vby certify that the plans and specifications covered by calculation are in compliance with the Florida Energy Review of the plans and f'iHE si% �p Co specifications covered by this 1,� . !'-4 calculation indicates, compliance,„��''� -with the Florida Energy Code: PR PARED BY: Before construction, is completedw DA E: this building will be'inspected for i I he eby certify that this building,'as.designed, is in .Q compliance with Section.563.908 , Florida Statutes. j� ~ wit �. the Florida Energy CCCb .� W1r"f�'Q O. NER/AGENT BUILDING OFFICIAL: DATE: DATE: - Iip ance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as ified factory -sealed inaccordance with R403.3.21. - C I impliance, requires an Air Barrier and Insulation Inspection Checklist in accordan a w�h R402:4: F:1-and-this-project-req0'r� an nvelope leakage test report with envelope leakage no greater than 1.00 ACH50 ( l)2 ji 2 �otL11 9/ /201812:23 PM EnergyGauge® USA Section R405.4.1 Compliant SoLaPPeeerrnitting Dej jartai egellto 6 Ude CGuntY, FL FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT F tle: INERT- RUIZ RESIDENCE Bedrooms: 3 Address Type: Street Address 11 uilding Type: User Conditioned Area: 1257 Lot # wner Name: Total Stories: 1 Block/Subdivision: Of Units: 1 Worst'Case: No PlatBook: ilder Name: Rotate. Angle: 0 Street: 220 OLSON AVENUE mit Office: ST LUCIE COUNTY Cross. Ventilation: No County: St. Lucie J risdiction: Whoie House Fan: No City, State, Zip: _FORT PIERCE, mily Type: Single-family FL, IS /Existing: New (From Plans) mment: CLIMATE pesign.Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort'Pierce FL_VERO_BEACH MUNI 39 90 70 75 299 62 Low BLOCKS umber Name Area Volume Entire House 1257 10056 SPACES umber Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated DINING i 100 800 No 0 1 Yes Yes, Yes KITCHEN 100 800 Yes 0 1 Yes Yes Yes UTILITY 103 824 No 0 1 Yes Yes Yes M BATH 60 480 No 0 1 Yes Yes Yes M CLST i 24 192 No 0 1 Yes Yes 'Yes MASTER BEDROO 156 1248 No 0 1 1 Yes Yes Yes BEDROOM 2 138 1104 No 0 1 1 Yes Yes Yes CLST 2 18 144 No 0 1 Yes Yes Yes BATH 2 54 432 No 0 1 Yes Yes Yes CLST 3 18 144 No 0 1 Yes Yes Yes 1 BEDROOM 3 138 1104 No 0 1 1 Yes Yes Yes HALL 42 336 No 0 1 Yes Yes Yes LIVING ROOM 306 2448 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area 'Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation DINING 20 ft 0 100 ft' 1 0 0 2 Slab-On=Grade Edge Insulation i KITCHEN 10 #t 0 100 ftz ___- 1 0 0 3 Slab -On -Grade Edge Insulation UTILITY 20 ft 0 103 ft2 1 0 0 4 Slab -On -Grade Edge Insulation M BATH 1 ft 0 60 ft2 _ _ 1 0 0 9/1 f2018 12:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 6 FO M R405-2017 IAIPI IT CI IRfiRAAOV rucw. mrlT .,.-.�... FLOORS # Floor Type yP 5 Sl:;.Grade Edge Insulation Space Perimeter Perimeter R-Value M CLST 10 ft 0 Area 24 ft Joist R-Value --- Tile 1 Wood 0 Carpet 0 6 Slab -On -Grade Edge Insulation MASTER BEDRO 13 ft 0 166 ft2 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 2 23 ft 0 138 f? 0 0 8 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 18 ft2 �� 1 0 0 9 Slab -On -Grade Edge Insulation BATH 2 6 ft 0 54 ft2 1 0 0 10SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 f? �_ 1 0 0 11SIab-On-Grade Edge Insulation BEDROOM 3 23 ft 0 138112 1 0 0 12SIab-On-Grade Edge Insulation HALL 1 ft 0 42 ft2 0 0 13SIab-On-Grade Edge.lnsulation LIVING ROOM 23 ft 0 '306 W ---- 1 0 0 ROOF Roof # Type Materials Area Gable Area Roof Color Solar Absor. SA Emitt Emitt Deck Tested Tested insul. Pitch (deg) 1 Gable or shed Metal 1295 ft2 156 fN Light 0.6 No 0.9 No 0 14 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1257 ft2 N N CEILING # Ceiling Type 1 Under Attic (Vented) Space . DINING R-Value 30 Ins Type Blown Area 106 ft2 Framing Frac 0.1 Truss Type Wed 2 Under Attic (Vented) KITCHEN 30 Blown 100 ft2 0.1 Wood 3 Under Attic (Vented) UTILITY 30 Blown 103 ft2 0.1 Wood 4 Under Attic (Vented) M BATH 30 Blown 60 ft2 0.1 Wood 5 Under Attic (Vented) M CLST 30 Blown 24 ft2 0.1 Wood 6 Under Attic (Vented) MASTER BEDRO 30 Blown 156 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 138 2 ft 0.1 Wood 8 Under Attic (Vented) CLST 2 30 Blown 18 ft2' 0.1 Wood 9 Under Attic (Vented) BATH 2 30 Blown 54 ft2 0.1 Wood 10 Under Attic (Vented) CLST 3 30 Blown 18 ft2' 0.1 Wood 11 Under Attic (Vented) BEDROOM 3 30 Blown 138 ft2 0.1 Wood 12 Under Attic (Vented) HALL 30 Blown 42.02 0.1 - Wood 13 Under Attic (Vented) i LIVING ROOM 30 Blown 306 ft2 0.1 Wood 9/10111812:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 I FO M R405-20V INPIIT c11IOnItAAOV ru=i-+vr ic%r .,r-r%. -- -- - - v■ ■■_v.aa-w � r��rvrt � WALLS F2W jacent Space Cavity Width p-A Height Ft In Sheathing Framing. Solar .Below } 4 5 6 7 8 9 10 11 12 13 14 15 �16 17 N E N E E E S S S S S W S W rior rior rior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Exterior Concrete Block- Ext Insul DINING Concrete Block - Ext'Insul. DINING Concrete Block- Ext Insul KITCHEN ConcreWBlock - Ext Insul UTILITY Concrete Block,- Ext Insul UTILITY Concrete Block - Ext Insul M CLST Concrete Block - Ext Insul M CLST Concrete Block - Ext InsdNASTER BE Concrete Block - Ext'InsiSEDR00M 2 Concrete Block - Ext InsiBEDROOM 2 Concrete Block-, Ext Insul CLST 2 Concrete Block - Ext Insul BATH 2 Concrete Block - Ext Insul CLST 3 Concrete Block - Ext InstBEDROOM 3 Concrete Block- Ext InstBEDROOM 3 Concrete Block - Ext InstNIVING ROO Concrete Block - Ext InsLUIVING ROO 4A 10 4.1 10 4.1 10 4.1 8 4.1 12 4.1 8 4.1 2 4.1 13 4.1 13 4.1 70 4.1 2 4.1 6 4.1 2 4.1 10 4.1 13 4.1 6 4.1 17 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 8 0 80.0 ft' 80.0 ft' 80.0 ft' 64.0 ft2 96.0 ft' 64.0 ft2 16.0 ft' 104.0 ft2 104.01`0 80.0 ft2 16.0 ft' 48.0 ft2 16.Oft : 80.0 ft' 104.0 ft2 48.0 ft2 136.0 ft2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.6 0.6 016 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.6 0.8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DOORS' j # Ornt Door Type Space Storms U-Value Ft Width In Height Ft In Area 1 N Insulated DINING None .39 3 6 8 20 ft2 II 2 S Insulated LIVING ROO None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation: # 1 i 2 3 4 5 6 7 Wall Ornt ID Frame Panes NFRC U-Factor SHGC W 2 Vinyl Low-E Single Yes 0.3 0.21 N 3 Vinyl Low-E Single Yes 0.32 0.25 E 5 Vinyl Low-E Single Yes 0.32 0.25 E 8 Vinyl Low-E Single Yes 0.3 0.21 S 10 Vinyl Low-E Single Yes 0.3 0.21 S 14 Vinyl Low-E Single Yes 0.3 0.21 W 17 Vinyl Low-E Single Yes 0.3 0.21 Imp Y Y Y Y Y Y Y Area 15.0 ft' 9.0 ft' 6.0 ft2 15.0 W 15.0 ft' 15.0 ft' 15.0 ft' Overhang Depth Separation 1 It 4 in 1 ft 4 In 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 R 4 in 1 ft 4 in 1 ft 4 in Int Shade None None None None None None None Screening None, None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 1P olehouse. I� Proposed ACH(50) '000356 1173.2 64.41 121.13 .2578 7 9110/1p18 12:23 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 6 FOF M R405-2017 INPUT Rl.1MMARV r341=r1fl IQT D=DnOT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip.Heat/ None COPA 17 kBtuthr 1 sys#1 COOLING SYSTEM # System Type 'Subtype -Efficiency Capacity Air Flow SHR Block 'Ducts 1 Central Unit/ Split SEER: 16 24 kBtu/hr 720 cfm 0.8 1 sys#1 �I HOT WATER SYSTEM i # Sys tem.Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None UTILITY 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Celt # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS —Supply -- -- Return -- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 125 ft2 Attic 13 fF Default Leakage UTILITY (Default) c(Default) c 1 1 TEMPERATURES Pr ramable Thermostat: N Ceiling Fans: C He Ve ing [j Jan Feb Mar ng [X]'Jan Feb HMar ing Apr Apr May Jun Jul May [ Jun jXjJui jXj Au [ ] AuL Se Sep Oct Oct Nov Nov Dec Dec H [ ]Jan Feb Mar A r [ l Ma t) Jun Jul [ ] Aug I Se [XJ Oct Nov Dec Ther Sche ostat Schedule: HERS 2006 Reference ule Type 1 Hours 2 3 4 5 6 7 8 9 10 11 12 Cooli g (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooli (WEH) AM 78 PM 80 78 78 80 80 78 78 78 78 78 80 80 80 80 I 80 78 78 78 78 78 78 78 78 Heati (WD) AM 65 PM 68 65 65 68 68 65 65 65 65 68 68 68 68 68 Heati 68 68 68 68 68 68 68 68 68 (WEH) AM 65 PM 68 65 65 68 68 65 65 65 68 68 65 68 '68 66 68 68 tl 68 68 68 68 68 68 68 812:23 PM EnergyGauge@) USA Section R405.4.1 Compliant Software Page 5 of 6 7 Mass Type Default(8 Ibs/sq.fL Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Default(8 Ibs/sq.ft. Name: Rating Compant: 812:23 PM SUMMARY CHECKLIST REPORT MASS Area : Thickness Furniture Fraction Space 0,ft2 0 it 0.3 DINING ft2 It 0.3 KITCHEN Ill It 03 UTILITY ft2 ft 0.3 M BATH ft2 It 0.3, M CLST ft2 It 0.3 MASTER BEDROO ft2 ft 0.3 BEDROOM 2 ft2 ft 0.3 CLST 2 ft2 It 0.3 BATH 2 ft2 It 0.3 CLST 3 1`12 ft. 0.3 BEDROOM 3 ft2 ft 0.3 HALL ft2 It 0.3 LIVING ROOM Signature: f Date: 9_" Io- 0 EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WERT- RUIZ RESIDENCE Builder Name: Street: 220 OLSON AVENUE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Y U Jurisdiction: Design Location: FL, Fort Pierce w x III U OMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA eneral ,I A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Air -permeable insulation shall r uirements Breaks or joints in the air barrier shall be sealed. not be used as a sealing material. fling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. The Insulation in any dropped ceiling/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Its The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls be Cavities within corners and headers of frame walls shall sealed. Knee walls shall be sealed. shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. W dows, skylights The space between window/doorjambs and framing, and any doors skylights and framing shall be sealed. Ripi joists Rim joists shall include the air barrier. Rim joists shall be insulated. FI III rs (in luding The air barrier shall be installed at any exposed edge of insulation, Floor framing cavity insulation shall be installed to ab ve-garage maintain permanent contact with the underside of an cantilevered floors) subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Cr space walls f Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Where provided instead of floor insulation, insulation shall be permanently attached to the crawispace wails. Sh ilfis, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. low Batts in narrow cavities shall be cut to fit, or narrow Na cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garl; ge separation Air sealing shall be provided between the garage and conditioned spaces. Rec ssed lighting Recessed light fixtures installed in the building thermal envelope shall be sealed to the drywall. Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. Plur and wiring Batt insulation shall be cut neatly to fit around wiring a n J Jbing plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shooer/tub on eiiterior wall The air barrier installed at exterior walls adjacent to showers and extend behind piDina and wirin .- Exterior walls adjacent to showers and tubs shall be tubs shall separate them from the showers and tubs. insulated. Electical/phone box on The air barrier shall be installed behind electrical or communication exte or walls boxes. or air -sealed boxes shall be installed. HVA I register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Con II ales When required to be sealed, concealed fire sprinklers shall only be sealed sprin lers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler a. in cover fates and walls or ceilin s. a dition, inspection of log walls shall be in accordance with the provisions of ICC-400. 9/10/2 18 12:24 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 III 7 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 94 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (ifmultiple=family) 3. 1 c) AHU location Attic/Attic 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0 5. Is this a worst case? (yes/no) 5. No a) Split system SEER b) Single package SEER 16.0 c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1257 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.303 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.217 14. Heating system: Capacity 17.0 c) Area 7c. 90.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f} Other , 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other -1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. L io Builder Signature: D�/ ate: ldress of New Home: 220 OLSON AVENUE City/FL Zip: FORT PIERCE, FL 812:24:09 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project SummaryJob: --',Wrightsoft. RECEIVE® Date: APr�s,so�s Entire House By: QUICK CALCS, INC. AUG 14 2018 317 ST UCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772 4 7 6 Ema' QUI I<C LCS AOL.CO A M V • • e ■ For: WERT-RUIZ RESIDENCE 220 OLSON AVENUE, FORT PIERCE, FL. Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions utside db 42 OF Outside db 90 OF side db 70 OF Inside db 75 OF esign TD 28 OF Design TD 15 OF Heating Summary tructure 14773 Btuh ucts 3024 Btuh ehtral vent (0 cfm) 0 Btuh umidification 0 Btuh iping 0 Btuh quipment load 17797 Btuh Infiltration ethod Simplified onstruction quality Average ireplaces 0 Heatingg Ea Cool ingg (ft-) 1257 1 olume (fta) 10056 1257 .10056 it changes/hour 0.45 0.23 quiv. AVF (cfm) 75 39 Heating Equipment Summary H R I ref fficiency eating input eating output :mperature rise ctual air flow it flow factor tatic pressure pace thermostat 100 EFF 4.8 kW 163711 BFuh 800 cfm 0.045 cfm/Btuh 1.00 in H2O Daily range M Relative humidity 50 . %. Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 13648 Btuh Ducts 4387 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh. Use manufacturer's data, Rate/swing multiplier . n 0.95 Equipment sensible load 17133 Btuh Latent Cooling Equipment Load Sizing Structure 2610 Btuh Ducts 11156. Btuh . Central vent (0 cfm) 0 Btuh . Equipment latent load .. 3766 Btuh Equipment total load 20899 Btuh Req. total capacity at 0.70 SHR 2.0 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1624AJlNA Coil RH1T2417STANJA AHRI ref 7940891 Efficiency 13:0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling .24000 Btuh Actual air flow 800 cfm Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Apr-12 11:12:16 Right -Suite® Universal 2017 17:0.08 RSU08101 Page 1 ltvvrightSoft' ets\Wrightsofl HVAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S rightsoft' Right-J® Worksheet Job: Entire House Date: Apr 12, 2018 By: - QUICK CALCS, INC. 317 S LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 oom name Entire House DINING 2 sed wall 152.0 ft 20.0 ft 3 oom height 8.0 ft 8.0 ft heat/cool 4 oom dimensions 10.0 x 10.0 ft 5 Foom area 1257.0 ft' 100.0 ft2 y Construction U-value Or HTM Area (ftz) Load Area (ft� Load number (Btuh/ft'. F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool - 6 13A flocs: ' 0:143 {) 4.Q0 2.�9 288259 1035 568 80 60 .� 239 130 2 glazing„dr low e.•. - :.0.300 ' n. 8;40 8.8t] 9 0 76 80 0 0 ' 0 -: 0 D 91D0 390 ,,n 10.92 10,34 20 20 _ 223 211 20 _ 20 . 223 211 11 G _w.. 13A-flocs 2 glazing, clr low a _0 0.143 0.300 a a _ 4.00 8.40 , _ 2.19 24.68 320 6 299 0 1197 50 654 148 0 0 0 0 0 0 0 0 < 2 alazina. clr low a 13A-flocs � ,_. 0,300 = 0.143 , e, ss ' _ - 8.40 .. 4.00 24.68 2.19 ' y , „ ,15 " 288 . 0 ^'' 238 _ _.,126 .. ��951 F , , . 370 - " ° 520 _ 0 ' 0 ... _0 "0 '. 0 ` , 0 2 glazIng,clr low a '� A.300 s 8.40 8.9p $0 " 60 252 267 , 0 _, 0 -0 0 D 11DQ:., 0,390. s..-_.w10.92 ---°.10.34.,.,.,,,,20,.». -. :::.20-....- 223"-211 __..': ._,-0 .;•»..._.,.0. .._....--0.. _- ..;:°0 13A-flocs 0.143 w 4.00 2.19 320 290 1161 634 80 65 260 142 2 alazinq, cIr loy e 0.300 , w... 8,40 24 68 30 0 252 740 15 _. 0 126 370 16B.30md" .. _ :0 032 _n ' 0.9Q. _. _..1,60 ...__ 1257 . 1257 _ 1126 ,_ 12'O11 . _._lob FI 22A-tph 1.358 38.02 0.00 1257 152 5780 0 100 20 760 0 a ,.� .. c . 6 c D excursion 0 127 E'Ivelope loss/gain 12453 6413 1698 1141 12 a Infiltration 2321 635 305 84 b Room ventilation 0 0 0 0 13 In rnal gains: Occupants @ 230 0 0 0 0 Appliances/other 6600 500 S �btotal (lines 6 to 13) 14773 13648 2003 1724 Ls external load 0 0 0 0 L s transfer 0 0 0 0 0 0 0 0 14 total icdistribution 14773 13648 2003 1724 15 tloads 20% 32% 3024 4387 200% 320% 410 554 T jal room load 17797 - 18035 2413 2278 Ai required (cfm) 800 800 108 101 of Manual J 8th Ed. - wrightsoft- 2018-Apr-12 11:12:16 ACGt� I Right -Suite® Universal 2017 17.0.08 RSU08101 Page 1 umnets\Wrightsoft HVAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S 'I rightsoft, Flight-JO Worksheet Job: Entire House Date: Apr 12, 2018 By: QUICK CALCS, INC. 317 S1 LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 oom name KITCHEN UTILITY 2 sed wall 10.0 ft 20.0 ft 3 oom height 8.0 ft heat/cool 8.0 ft heat/cool 4 oom dimensions 10.0 x 10.0 ft 1.0 x 103.0 ft 5 oom area ft 100.0 ' 103.0 fN y Construction U-value Or HTM Area (ft') Load Area (ft� Load number (Btuh/ftz °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool • 6 13A-4ocs ; 0.143 , - n 4.00 2.19 _ 80 _... 71 -- ,_. 284 155 64 " W 6A 256 :140 2.glazing, ¢Ir IoW e - �0 300 -� nx 8:40 8.90 ;9 : -. _ 0 76 80 p ,.' D 0 0 O 1092 1034 0 0 .__ 0 0 _ 0 - 0• 0 0 13A4acs _._ _ �.190 4.00 _ 2.19 _o ,. .. o _ 0 _ O 96 90 360 197 11 2 glazing, clr low-e 0.300 a 8.40 24.68 0 0 0 0 6 0 50 148 • 2 alazinq..clr low e- .. 0.300 _. e.. .e. 8.40 24.68 0 0 0 0 0 _0 u0 ;, 0. 0 13Q 9ocs -< Q 143 s- '4:OQ °> 2.1,E , C) 0 A < 0 .: ,0 ,<, r 0' 0 2 glazing clr low e o 300 `s 8 40 8 90 0 0 0 0 0 0 0. 0 D. _11P0 . "T;_._ _�.._ 0;390 ,., s',._, _ „ 10.92 ,_._ 10,3A M .__ 0 _ ._ _:,.._,0 ._. _'' _.9 __ � __0 . _ - _ ._..0 .,,: _ l) _, .,0: ..F. , ,.�0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazinq..clr low. a 0.300 W_ , 8.40 24,08 0 0 0 0 0 0 0 C I6B-30md :' _- . ,_" -. _ ,_ �0,032 _- - -:,, , _ 0.90 -, -. 1.6Q -, - __1D0 _ 100 _- ,:.. 90 160 . _ -103 _.� _ _ _103 „_ " - 92 - -_,-_ 16.5 F 22A-tph ._ 1.358 38.02 0700 100 10 380 0 103 20 760 0 77. 6 c), ED excursion -50 -19 E elope loss/gain 830 345 1520 631 12 a) I Infiltration 153 42 305 84 b) II Room ventilation 0 0 0 0 13 In 8mal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 500 S total (lines 6 to 13) 982 1587 1825 1214 L l s external load 0 0 0 0 L s transfer 0 0 0 0 R istnbution 0 0 292 82 14 S total 982 1587 2117 1297 15 D tloads 20% 32% 201 510 20% 32% 433 417 To I room load 1183 2097 2550 1714 Ai 'required (cfm) 53 93 115 76 II Calculations aeproved by ACCA to meet all re uir wrlghtsOft` Right -Suite® Universal 2017 17.0.08 RSU08101 CCK �..umnets\Wrightsoft HVACIWERT- RUIZ RESIDENCE.rup Cate = MJ8 Front Door faces: S 2018-Apr-12 11:12:16 Page 2 rightsoW Right-J® Worksheet Job: Entire House Date: Apr12,2018 By: QUICK CALLS, INC. 317 ST ILUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: OUICKCALCS@AOL.COM 1 1 oom name M BATH M CLST 2 osed wall 0 ft 10.0 ft 3 oom height 8.0 ft heat/cool B.0 ft heat/cool 4 oom dimensions 6.0 x 10.0 ft 12.0 x 2.0 ft 5 oom area 60.0 ftz 24.0 ft' i y Construction U-value Or HTM Area (ft� Load Area (M Load I number (Btutdit? °F) (Btuh/ftz) or perimeter (ft) (Btuh) ' or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool • 6 "13A-400s'"� 01, _ "n`" 4OR -219 - '0 0 .._. 0 0 64 84' 258 _�140 2 glazing clr low e 0 300 ri $ 40 8 90 0 0 0 0 0 0 0 0 D, .'11D0 10,92, . „10- 0 _ 0 »._....:,»_0 0 "» ....w. ._0 ...._ Q _.._._. _,__.0 ...» . _"--0 13A-flocs 0.143 a 4.00 2.19 0 0 6 0 16 16 64 35 11 2 glazing, clr low-e 0.300 a 8.40 24.68 0 0 0 0 0 0 0 0 2 alazinq clr low a ,,, 13A-flocs " 2 glazing e(r low a ,,0,300 9:143 0.300 e.. `s 's, 8,40 9r00 . 8;40 24.6,8. " , 2:19Q 8.90 0 0 0 ' 0 0 0 "'. 0 0 0 0 0 -. 0 , : P" 0 0 ` r` _ 0. 0 0- ,>' " 0 �0 0 0 0 0 11p0„ »...::....... .:! ......_Ano ;' s, ... 10,92 ,.."..10.3q . !0 .„ ,_ .. .0 ,. .._- `...0 . »M___ 0 _. _ 0 _ ..._ 0 -0 13A4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazlnq qlr low e 0 300 W. 8.40 24,,68. 0 0 0 0 0 0 ., .� r0 ,0 C ��16839md ._.. _ ::`: 0�032 » �. ..:,0.90 _� 1.60 .».». 60 »_....„_ 60 .�°_ 54 .__. 96._ 24 - 24 _ _ _�22,_ F I 22A-tph 1.358 . _ 38.02, ... 0.00 .. ... 60 .,.... - . 0 :. - 0 _,. 0 a 24 _ 10 __.. - ,-... 380 _0 a W .. ... ... .......- ...,... .. .... ,,__ 71e.. ... � s, ..._.. .. v,.m+�.+. ..,..t........z..C,,... _ .., ., ..aw....., F.".,,.wx.»... ....xu.,,,,... ,. _.,, ...t..,.:......_ .&_ .. ..... .., x ... x,.... „...m »,.n .a. 6 c)I ED excursion -12 -8 E elope loss/gain 54 84 722 206 12 a) Infiltration 0 0 153 42 b) Room ventilation 0 0 0 0 13 Intl mal gains: Occupants @ 230 0 0 0 0 Appliances/other 300 0 S total (lines 6 to 13) 54 384 875 247 Le s external load 0 0 0 0 Le s transfer 0 0 0 0 9 15 -875 -247 14 listribution total 62 399 0 0 15 tloads 1 20% 32% 13 128 20% 32% 0 0 T1 room load ;eauired 1 75 527 0 0 A (cfm) 3 23 0 0 Calculations aDDroved bvACCA to meet all reauir wrightsoft` Right -Suite® Universal 2017 17.0.08 RSU08101 t ets\Wrightsofi HVAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 11:12:16 Page 3 - rightsoft' Right-JO Worksheet DOD: Entire House „ , Date: Apr 12, 2018 By. QUICK CALCS, INC. 317 SIUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,40L.COM 1 Room name MASTER BEDROOM BEDROOM 2 2 Exposed wall 13.0 ft 23.0 ft - 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 13.0 ft 1.0 x 138.0 ft 5 Room area 156.0 ft' 138.0 ft' y Construction U-value Or HTM Area (ftz) Load Area (ft') Load • i number (Btuh/ft? °F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs _. 0143 ' n : 4.00 2.19 -0 .� 0 0 0 0 �0 - 0 0- b411D0- s� 2 glazing, clr low e 0. 00 n 8 d0 890 0 0 0 o 0 0 0 0 µ _ 0,390 n,� 10:92 10rn34 0 0 D U 0' m 0 -228 .F,m. 13Aflocs 0.143 a 4.00 2.19 104 89 356 195 104 104 416 11 2 glazing, clr low-e 0.300 a 8.40 24.68 0- 0 0 0 0 0 0 0 2 glazinq. clr low a 0.300 _ ,e _ _8.40 24.68 15 0 . ° _., 126 370 _. 0 ', , , 0 ,_ 0 0 :12 :13A 4ocs._,-p,143 2 glazm0 clr low e D 300 s. , s` . , 4100, 8 40' 2:19, 8 90 0 0 , 0- 0 0% 0 0 0 80 15 ,� „ 65 _ 15 260; 128 134` ,± , ,_.___,:0 390 : _s., ._.. 10.92 , .. 10,34' .__, _.. ,.0 , .. _,_ ::, D __ .. _„ ::: 0 , ._.,,_:..,__0 _ __. . ,.. 0 ....:.-,._. , 0 m _,_ _ _.:0: <«._«_ , '.0: 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing,plr low, a 0.300 w . 8.40 24,68 0 _ 0 _ 0 0 0 _ 0 _„,0 0. 0;032 _ . _:_ .. _, ..0 90. -_ , ,_1 60 _._ 156 _ -._ 156 _ :_,- .140 --,._ _.250 _ _138 138 .,, 124 -..__, _ 221 F 1 22A tph - 1.358 38.02 0.00 „ 156 13 494 _ 0 138 23 875 '0 -a 71 - 6 c ED excursion -7 -56 Ei 1velope loss/gain 1116 807 1801 666 12 a) Infiltration 198 54 351 96 b)II Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 l Appliances/other 900 1 ODD S 4total (lines 6 to 13) 1315 1761 2152 1765 L �s external load 0 0 0 , 0 L ss transfer 0 0 0 0 R istribution 588 172 109 49 14 S total 1902 1934 2261 1813 15 D tloads1 20% 32% 389 622 20% 32% 463 583 To l room load 2292 2556 1 2723 2396 Ai ,required (cfm) 103 113 122 106 AG vvrightSo t` Right -Suite@ Universal 2017 17.0.08 RSU08101 Ill.. umnets\Wrightsoft WAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 11:12:16 Page 4 rightsoft' Right-JO Worksheet Date: Entire House Date: Apr 12; 2018 By: QUICK CALLS, INC. 317 S LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name CLST 2 BATH 2 2 ,Exposed wall 2.0 ft 6.0 ft ` 3 'Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 'Room dimensions 2.0 x 9.0 ft 6.0 x 9.0 ft 5 Room area 18.0 ftz 54.0 ftz y Construction U-value Or HTM Area (ft� Load Area (ftz) Load number (Btuh/ft2 `F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool ` 8 13A flocs 0_ 43 .:n 4:O0 '2.18 0, 0 ' 0 .F 0 0 2 glazing clr low e 0 300 n. 8 40 6.90 0 0 0 0 0 0 0 ;0 0.890 n` - 1092 0 '' 0 9 13A-40cs 0.143 e» 4.00 2.19 0�0 0 0 0 0��� 0 0 11 2 glazing, clr low-e 0.300 a 8.40 24.68 0 0 0 0 0 0 0 0 2 olaztn4, clr low a 0,300 8,40 24 68 0 0 0 0 O W- 0 __ 0 0 '13A4ocs 0;143 _e . 1" s- �',4:00 2.;19 „°18 w 16 64 35 ^.� ,46 -' 48 `< �192- �' 105 L—G2 glazing clr low a 0 300 s 8.40 8 90 0 0 0 0 0 0 0 0 D :11D9 - .. Q'890 , ss _ a 10,02 , s_ 10 _. , 0 _ . , 0 _,_ . 0 ... _ . _ .-0 - 0 a._....... .. 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 plazinci clr low a 300 .,AM,- -, 40 . _ 24,88 0 0 0 .... _ Q .w._ 0 ._ 0 0 = . .. 168 30md:n .____. - ::-. ,_,0 . __ _0 032 ., ;... ,8 _ .; - 0;90 w -:..' 1i60 .-.9 . _ - ' .18 .. _^. ,. :18 - _:.,16 _A __ ': 29 „ __. ,:,. "_� 54 _ _ ., .- _. _54 .., -_ .48 ,.. _ .:.86 F 22A tph r,1; 358 38.02 0.00 18 2 76 0 54 6 228 0 i n. _. r , tW 6 c&ED excursion -2 -16 Et .lope loss/gain 156 621 469 176 12 a)I Infiltration 31 8 92 25 b) Room ventilation 0 0 0 0 13 In gains: Occupants @ 230 0 0 0 0 Irnal 1I Appliances/other 0 300 S I total (lines 6 to 13) 187 70 560 501 L s external load 0 0 0 0 Ls transfer 0 0 0 0 R � istribution -187 -70 177 78 14 S total 0 0 737 579 15 D ° t loads 20% 32%1 0 0 20% 32% 151 186 To al room load 0 0 888 765 Ai required (cfm) 01 01 40 34 Calculations aaaroved by ACCA to meet all reauir ACC 17wrightsofta Right -Suite® Universal 2017 17.0.08 RSU08101 -ets\Wrightsoft HVAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S 2018-Apr-12 11:12:16 Page 5 Manual J 8th Ed. 4V- wrightsoft- Right -Suite® Universal 2017 17.0.08 RSU08101 ..umnets\Wrightson WAC\WERT- RUIZ RESIDENCE.rup Cale = MJ8 Front Door faces: 8 2018-Apr-12 11:12:16 Page 6 Calculations approved byACCA to meet all requir wtrightt5aft` Right -Suite® Universal 2017 17.0.08 RSU08101 umnetslWrightsoft WAC\WERT- RUIZ RESIDENCE.rup Calc = MJ8 Front Door faces: S of Manual J 8th Ed. 2018-Apr-12.11:12:16 Page 7 Job: ff wrightsoft� Duct System Summary Date: Apr12,2018 Entire House By: QUICK CALCS, INC. • 317 S LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM i ® •0 In"foemcitio II For: WERT RUIZ RESIDENCE 220 OLSON AVENUE, FORT PIERCE, FL I al static pressure re losses le static pressure return available pressure friction rate air flow ffective length (TEL) Heating Cooling 1.00 in H2O 1.00 in H2O 0 in H2O 0 in H2O . 1.00 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1.000 in/ 100ft 800 cfm 800 cfm 162 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR ' Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv_ Ln (ft) Trunk BATH' h 888 40 34 1.000. 5.0 Ox 0 VIFx 19.0 135.0 st3 BED OM 2 h 2723 122 106 1.000 7.0 Ox 0 VIFx 27.2 135.0 st3 .. . BED OM 3 h 2723 122 106 1.000 7.0 Ox0 VIFx 23.2 135.0 . ,: st3 DINI h 2413 108 101 1.000 7.0 Ox0 VIFx 13.0 115.0 st1 KITc N . c 2097 53 93 1.000 7.0 Ox0 VIFx 8.1 115.0 st1 LI Roots c 3306 133 147 1.000 8.0 Ox 0 VIFx 15.5 115.0 st2 B M BA c 527 3 23 1.000 5.0 Ox 0 VIFx 9.7 115.0 st2 MAS R BEDROOM c 2556 103 113 1.000 7.0 0x 0 VIFx 13.1 115.0 st2 UTILI h 2550 1 115 76 1.000 6.0 Ox0 VIFx 8.6 115.0 st1 Trunk . Htg Clg Design Veloc Diam H x W Duct Na a Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk . st3 Peak AVF 285 246 1.000 645 9.0 0 x 0 VinlFlx st2 st2 Peak AVF 524 530 1.000 803 11.0 0 x 0 VinlFlx st1 I Peak AVF 276 270 1.000 625 9.0 0 x 0 VinlFlx Grill Htg . Clg TEL Design Veloc Diam H x W Stud/Joist Duct. Na a Size (in) (cfm) . (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 800 800 0 0 0 0 Ox 0 VIFx his document was created with Win2PDF available at http://www.win2pdf.com. he unregistered version of Win2PDF is for evaluation or non-commercial use only. his page will not be added after purchasing Win2PDF.