HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFE
j�IED
BCIS Home I Log In i User Re istration j t Topics ub rcharge rats &Facts Publications Contact Us I BCIS Site Map :Links i Search
H� {a g elf
ir�g " Product Approv I y Permitting
'USER: Public User ST. Lucie Count ,
Product Aonroval Menu > product or AnnlicatiorrSearch > Application I'st > Application Detail ,q [�(\a(a8 .
c�7Jflty/_ d``Jj��e
FL # EM
FL11175-R3 BY
Application Type Revision �as
Code Version 2017 t. I� �� c
Application Status Approved
Comments
Archived j
Product Manufacturer Southeastern Metals Mfg. Co.
Address/Phone/Email 11801 Industry Drive
Jacksonville, FL 32218
(904)696-4682
jhkelsey@semetals.com
Authorized Signature
Jeremy Kelsey
jhkelsey@semetals.com
Technical Representative
Jeremy Kelsey
Address/Phone/Email
11801 Industry Dr.
Jacksonville, FL 32218 .
(904) 757-4200 Ext4682
jhkelsey@semetals.com
Quality Assurance Representative
Jim Horton
Address/Phone/Email
11801 Industry Drive
Jacksonville, FL 32218
jwhorton@semetals.com
Category
Roofing
Subcategory
Metal Roofing
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Zachary R. Priest
the Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
LL LLC
Quality Assurance Contract Expiration Date
12/31/2020
Validated By
Locke Bowden P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence
FL11175 R3 COI SEM12001.2 2017 FBC Eval Report Metal Roofing
final.Ddf
Referenced Standard and Year (of Standard)
Standard Year
TAS 125 2003
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
09/26/2017
Date Validated
09/26/2017
Date Pending FBC Approval
10/04/2017
Date Approved
12/12/2017
Summary'of Products
t
FL #
Model, Number or Name
Description
11175.1
Non -Structural Metal Roofing
Fastened, snap lock, and mechanically seamed panels
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FI-11175 .113 II SEM12001 2 2017 FBC Eval Report Metal
Rpofing_final_- Of
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation for allowable pressures and limits of
Evaluation Reports
use
FL11175 R3 AF SEM12001 2 2017_FBC Eval Report Metal
Roofing final.pdf
Created by Independent Third Party: Yes
Bacic Next
Contact Us :: 2601 Blair Stone Road. Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Coovriaht 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: `
Credit Card
Safi
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:. Southeastern Metals Mfg Co., Inc.
11801 Industry Drive
Jacksonville, FL 32218
(800) 874-0335
Manufacturing Plants: Jacksonville, FL
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
FLORIDA BUILDING CODE, 6TIH EDITION (2017)
Quality Assurance: Underwriters Laboratories Inc. (QUA1743)
SCOPE
Issued September 25, 2017
Category:
Subcategory:
Code Sections:
Properties:
PRODUCT DESCRIPTION
Roofing
'Metal Roofing
1504.3.2
Wind Resistance
Profile:
SM-RIB
Description:
min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min. 80 ksi; 3/4" rib; 36"
coverage; fastened panel;.Shall conform with FBC Section 1507.4.3
Profile:
5V Crimp
Description:
min. 29 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min. 50 ksi; 7/16" rib; 24"
coverage; fastened panel; Shall conform with FBC Section 1507.4.3
Profile:
PBR
Description:
min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min, 80 ksi; 1-1/8" rib; 36"
coverage; fastened panel; Shall conform with FBC Section 1507.4.3
Profile:
Corrugated
Description:
min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min. 33 ksi; 1/2" corrugation; 24"
coverage; fastened panel; Shall conform with FBC Section 1507.4.3
Profile:
Sem-Lok
Description:
min. 26 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min. 50 ksi; 1" rib; 16" coverage;
snap lock standing seam panel; Shall conform with FBC Section 1507.4.3
Profile:
Sem-Lok
Description:
min. 0.016 ASTM B 370 copper clad Type 430 stainless steel (Copper XT7); 1" rib; 16"
coverage; snap lock standing seam panel; Shall conform with FBC Section 1507.4.3
Profile:
Sem-Lok
Description:.
min. 0.032-inch aluminum 3105 H-24; V rib; 16" coverage; snap Pock standing seam
panel; Shall conform with FBC Section 1507.4.3
Profile:.
Verti-Lok
Description:
min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90;. Fy = min. 50 ksi; 1-3/4" rib; 16"
coverage; snap lock standing seam panel; Shall conform with FBC Section 1507.4.3
Profile:
Rock-Lok
Description:
min. 24 ga. ASTM A792 AZ50 or ASTM A653 G90; Fy = min. 50 ksi;"2" rib; 16" coverage;
mechanically seamed standing seam panel; Shall conform with FBC Section 1507.4.3 .
SEM12001.2 FL11175-R3 Page 1 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
tRtEK
" TECHNICAL SERVICES, LLC
APPROVED ASSEMBLIES
Southeastern Metals Mapufacturing'Co., Inc.
Metal Roof Systems
ASM 1 29 ga "SPA RIB
� �°
Slope:
3:12 or greater
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC .
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-63.5 psf when fastened max. 24" o.c.-as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
...... __..... . ...... ............36" Coverage
1.7..M.:..._.. -_ ....:...._.:
min. 15132" P.yw _ #9-15 FiWH wood screw with sealing washer.
spaced 24" o.c. with min. 3/8" deck penetration.
Lap Detail:
_ _ ... ----
-w ...---_......__ _.._._
SEM12001.2 FL11175-R3 Page 2 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. '
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern, Metals Manufacturing Co., Inc.
Metal Roof Systems
:AS'M 2: 29 ga SM RIB
Slope:
3:12 or greater
Deck:
Min. 15/32" plywood for new and existing construction with wood supports -spaced a
maximum 24". o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-101 psf when fastened max. 24" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
t..._..... _..... ........ ...._........---- ------- ._. 36" Coverage...._. .... _........... _._..---....... _ -
�_
min. 15/32" plywood #9-15 HWH wood screw with sealing washer
spaced 24" o.c. with min. 3/8" deck penetration.
Lap Detail:
----------
----------
-------_------
SEM12001.2 FL11175-R3 I Page 3 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREED
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 3:' 29 ga. 5V Gnrrlp
Slope:
3:12 or greater
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-71 psf when fastened max. 16" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
I i
IPA
..q... ........ ......... ... ........,.... ... ...... �.. .. t. ,-�....... .... .... .. ..... ... .. ......... .... a... .... _..e ..... ..+
min. 15/32'" plywood HWH wood screw with sealing washer
spaced 1 6" o.c. with min. 3/8" deck penetration.
Lap Detail:
SEM12001.2 FL11175-R3 Page 4 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty,, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREED
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
. Metal Roof Systems
AsM .4: 29 ga `5V primp
Slope:
3:12 or greater
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw With sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-71 psf when fastened max. 16" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
Allowable Pressure:
-93.5 psf when fastened max. 12" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
Coverage _,,.. _.....
... ........., ..
min. 15/32" plywood--'` _#9-15 HWH.wood screw.with sealing washer
s
spaced 12" o.c. with min. 3/8" deck penetration.
- ,
Lap Detail:
-----------
y ---
.-
SEM12001.2 FL11175-R3 Page 5 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK.
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof. Systems
w
Slope:
2:12 or greater; Apply lap sealant in accordance with manufacturer's instructions under 3:12
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1 .
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
Attachment:
penetration; #12 x 3/4" HWH metal screws with sealing washers installed 12" o.c. in the
panel side lap as shown below
Allowable Pressure:
-84.25 psf when fastened max. 24" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
--
____._._36" Coverage---77
i�
min. 15/32" plywood- r 1. #9-15 HWH wood screw with sealing washer .
spaced 24" o.c. with min. 3/8" deck penetration.
t s1 ,_012 ,(a/Q1" IMIA metal sprow
yr %vith So',,Ang wisher 12"o.c.
Lap Detail:
r
a � y
SEM12001.2 FL11175-R3 Page 6 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
JCREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 6, 26,�a_ PElR ,
Slope:
2:12 or greater; Apply lap sealant in accordance with manufacturer's instructions under 3:12
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
Attachment:
penetration; #12 x 3/4" HWH metal screws with sealing washers installed 1" o.c. in the
panel side lap as shown below
Allowable Pressure:
-121.75 psf when fastened max. 16" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
;_ ........_ ....... ............... ......... -36" Coverage .___. ..._.. _ ... _..... _........... _.
(
�\ —...._ .._.... //
a; :::. i
min. 15/32" plywood---` "- ., 15 HWH wood screw with sealing washer
.#9
spaced 16" o.c. with min. 3/8" deck penetration.
„ t�12 x 5i,1" HWH mgW.scrq'w
ill
Lap Detail: ..
_,.. �... * IT]
_ . _
12001.2 FL11175-R3 - Page 7 of 21
evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
nical Services, LLC of any product changes. or quality assurance changes throughout the duration.for which this report is valid.
evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
fically addressed herein.
CREED
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 7: 26 ga Corrugafed
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-86 psf when fastened max. 16" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
Coverage__-__.._. �.._
—........... -
,f
min. 19/32" plywood.-'� `ll- . ,#9-15 HWH wood screw with sealing washer
spaced 16" o.c, with min. 3/8" deck penetration.
Lap Detail:
----------------------------
SEM12001.2 FL11175-R3 Page 8 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
L CREED
L
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 8 26,ga Corrugatetl
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#9-15 HWH wood screw with sealing washers installed as shown below with min. 3/8" deck
penetration
Allowable Pressure:
-116 psf when fastened max. 12" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
r24" Coverage --.-._..._._............. _.....
I
`..�"`',-__....._......._..........:.' ..............:._.:.:......_� - ;'' . ,r.' ^--.-'-' ~ .w.--._
_. . � _ ._._.. _._ ..................
........
min. 19/32" plywood—/ , ,_#9-15HWH wood screw with sealing washer
spaced 12" o.c.,with min. 3/8" deck penetration.
Lap Detail:
---- ---- ---------- --
SEM12001.2
FL11175-R3
9of21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 9:� 26 ga- Sem Lok
Slope:
3:12 or greater
Deck:
Min'. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#10-12 pancake head wood screw installed as shown below with min. 3/8" deck penetration .
Allowable Pressure:
-52.5 psf when fastened max. 7" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
Coverage_........_...........__._.._.....__.__.____.....
...
1"
..-'----........_..__.-._....... -...... ..................._................ ..... ------------- _......._-'--'---._..._..__.......... ..................__..._......._...__.._--...........
...._................----.._ __._
min. 15/32" plywood #10-12 pancake head wood screw 7" o.c.
N
with min, 3/8" deck penetration.
Lap Detail:
SEM12001.2
FL11175-R3
10 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC'
Southeastern Metals Manufacturing Co.;'lnc.
Metal Roof Systems
A$M 10 p16 Copper XTT"' Seth Luk
Slope: r
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#10-12 pancake head wood screw installed as shown below through "HVHZ Zone Cleat"
with min. 3/8" deck penetration
Allowable Pressure:
-99.25 psf when fastened max. 7" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
-- — —16" Coverage
i"
A_
VIP
am '
'.
min..1968 plywood •...... ... r
#10-12 pancake head wood screw7" o.c..✓
with min. 3/8" deck penetration.
Saro-fok Panel
HVHZ Zone CIeat.(Cl.p3)
Lap Detail:
¢'
Pancake Screw
SEM12001.2 FL11175-R3 Page 11 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
!Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
Southeastern Metals Manufacturing Co., Inc
CREEKMetal Roof Systems
TECHNICAL SERVICES, LLC
ASM 11 016 Copper XT;T"" Seth-Lok ° ;;
Slope:
3:12 or greater
Deck:
Min. 15/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#10-12 pancake head wood screw installed as shown below with min. 3/8" deck penetration
Allowable Pressure:
-69.25 psf when fastened max.7" o.c. as shown below
Pressure calculated using 2:1, margin of safety per 1504.9
_.._._...._... - ...._._ .._.._.__._... 16" Coverage ................ ---.._..-- _ ...._._._. ..-
1"
P,
............. _:..� � �- _: -::--c.:-'..'-:..- -.:::.:�... __.._..
(w _ .. ..
1"t.__...._.__.
_ ......._:...................---"----__......_ ........_ ................ ._...__.- .. .........
f
min. 15/32" plywood m...- '" #10-12 pancake head wood screw 7" o.c.�R
with min, 3/8" deck penetration.
Lap Detail:
L=
SEM12001.2 FL11175-R3 Page 12 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does, not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 12; .032 Aluminum Seth Lok : ;
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
#10-12 pancake head wood screw installed as shown below through "HVHZ Zone Cleat"
with min. 3/8" deck penetration
Allowable Pressure:
.63.75 psf when fastened max. 7" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
— —----16" Coverage
1
min. 19/32" plywood �~ #10-12 pancake head wood screw 7" o.c.
with m1h. 3/8" deck penetration,
Sam-tok: banal
HVHZ Zghe Cleat (CL-3)
Lap Detail:
Pancake Screw
SEM12001.2 FL11175-R3 Page 13 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for.which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
g. Southeastern Metals Manufacturing Co., Inc.
CREEK,Metal Roof Systems
'TECHNICAL SERVICES, LLC
ASM 3 0�2 `6w _ um tem-Lok'
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with.wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
#10-12 pancake head wood screw installed as shown below through "HVHZ Zone Cleat"
Attachment:
with min. 3/8" deck penetration; Liquid Nails® Heavy Duty Construction Adhesive applied in
min. 1/2" continuous bead as shown below
Allowable Pressure:
-120 psf when fastened max. 7" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
.__ 16" Coverage—_.y...W—_....._—
I
__
min. 19132" plywood '~ #10-12 pancake head wood screw 7" o.c.
with min:. 3/8" deck penetration,
ern lak Panel
. - VHz ZOO Cfi* CL-3)
L[quid Neils Heavy Duty
Construction Adhesive
Lap Detail:
Pancake Scow
SEM12001.2 FL11175-R3 Page 14 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
'Metal Roof Systems
ASM 14 , 24 ga cVertt Lok �' � '
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
(2) #10-12 pancake head wood screws installed per 18 ga. UL90 clip as shown below with
Attachment:
min. 3/8" deck penetration; Liquid Nails® Interior and Exterior Marble and Granite Adhesive
applied in min. 1/4" continuous bead on backside of male lock as shown below
Allowable Pressure:
-71.25 psf when clips spaced max. 24" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
16" Coverage- —
J
wmmn
_ ;;,.:x.x.mmx�xm..amvx_�.z....««vrax-�uwex:wx<xxu.w nexxx.eaxxxwx.exemvnmv.:�..xxmnm:ex...::x�ay.:�:-x<.x..�xm<«��.�. ..
------------------
min. 19/32" plywood--- (2) #10.12 pancake head wood screws per.UL90 clip
24" o.c. with min. 318" deck penetration
U uld Nails Interior and Exterior
Marble and Granite Adhesive
1
Lap Detail:
SEM12001.2
FL11175-R3 Page 15 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
'AS M 15:, 24 ga,,Vertf Lok. ;
Slope:
3:12 or greater
Deck:
Min. 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall be designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
(2) #10-12 pancake head wood screws installed per 18 ga. UL90 clip as shown below with
Attachment:
min. 3/8" deck penetration; 'Liquid Nails® Interior and Exterior Marble and Granite Adhesive
applied in min. 1/4" continuous bead on backside of male lock as shown below
Allowable Pressure:
-97.5 psf when fastened max. 12" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
�-� 16" Coverage
d
min. 19132" plywood '` (2) #10-12 pancake head wood screws per UL90 clip ._......_f
12" ox. wilh'min. 3/9" deck penetration
Liquid Nails Interior and Exterior
Marble and Granite Adhesive
Lap Detail:
12001.2
FL111
16 of 21
evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
nical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
evaluation report does not express nor imply warranty, installation; recommended use, or other product attributes that are not
ificaliv addressed herein.
A
s
sSoutheastern Metals Manufacturing Co., Inc.
CREEKMetal Roof Systems
TECHNICAL SERVICES, LLC
"ASM 16: 24 gaE Verti l;ok
Slope:
3:12 or greater
Deck:
Min. 22 ga. B-Deck (Fy = 33 ksi) for new and existing construction with structural supports
spaced a maximum 5-ft o.c.; Shall be designed by other is accordance FBC
Insulation (optional):
Min.1" and max. 4" insulation board
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
(2) #14-13 pancake head, self -drilling screws installed per 18 ga. UL90 clip as shown below
Attachment:
with min. 3/4" deck penetration through a 6" x 6", 22 ga. bearing plate; Liquid Nails® Interior
and Exterior Marble and Granite Adhesive applied in min.,1/4" continuous bead on backside
of male lock as shown below
Allowable Pressure:
-71.25 psf when clips spaced max. 24" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
I_.,,,_.__�_�__� _.__._.__. �._.._._.__.._..__.____._._.._....-..._..16"•Coverage_..__.._...___—___._____._.____..___......__._._�,,,..�
U 1211,
(2} #t14-13 self -drilling metal screws per UL90 clip-.__�'�
24" o.c. with min. 3/4" deck penetration
min. 22 ga. B-Deck —
�^ Liquid Naile Interior and Exterlor
ii Marble and Granite Adhesive
{
— 22 ga. bearing plate
L, r
._.... ........_..., ............_._..._:cam::.:..._._. _._.
Lap Detail:
SEM12001.2 FL11175-R3 Page 17 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
echnical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
his evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
Decificallv addressed herein.
3
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc:
Metal Roof Systems
ASM 1724 ga1/ertt t:ok <.. 4 C:
Slope:
3:12 or greater
Deck:
Min. 22 ga. B-Deck (Fy = 33 ksi).for new and existing construction with structural supports
spaced a maximum 5-ft o.c.; Shall be designed by other is accordance FBC
Insulation (optional):
Min.1" and max. 4" insulation board
Underlayment:
As required in accordance with 1507.4.5
(2) #14-13 pancake head, self -drilling screws installed per 18 ga. UL90 clip as shown below
Attachment:
with min. 3/4" deck penetration through a 6" x 6", 22 ga. bearing plate; Liquid Nails® Interior
and Exterior Marble and Granite Adhesive applied in min. 1/4" continuous bead on backside
of male lock as shown below
Allowable Pressure:
-90 psf when clips spaced max.12" o.c. as shown below
Pressure calculated using 2:1 margin of safety per 1504.9
+ 16" Coverage
f-
4�
(2) #14-13 self -drilling metal screws per UL90 clip ! .
12" ox. with min. 3/4" deck penetration
-.._.._..__.. ..... ..............................................._.__.-....................__._....................._-...._.- ...... .... -..._.._......__._.._......._... ....-......�.^.��........_._.._..._..._._..- .._.._._.—. - ----...__._....._
min. 22 ga. B-Deck — l
Liquid Naile'Inledor and Exterior
r Marble and'Granite Adhesive
/
l-- 22 ga. bearing plate
Lap Detail:
SEM12001.2 FL11175-R3 . Page 18 of 21
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
his evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
pecifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM 1 B 24
ga ;Rock-L'ak
u
Slope:
1:12 or greater
Deck:
Mina 19/32" plywood for new and existing construction with wood supports spaced a
maximum 24" o.c.; Shall .be.designed by other is accordance FBC
Underlayment:
As required in accordance with FBC Section 1507.4.5:1
Attachment:
(2) #10-12 pancake head wood screws installed per 22 ga. UL90 clip as shown below with
min. 3/8" deck penetration;
-93.5 psf when clips spaced max. 16" o.c._
Allowable Pressure:
-101 psf when clips spaced max.12" o.c.
Pressure calculated using 2:1 margin of safety per 1504.9
do Nominal16 (15.940) ---►�
i
2 '
I
5.540 5.20 5.20
1,
Lap Detail:
FACTORYAPPLIED FACTORYAPPLIED
SEALANT SEALANT
C.IP GLIP
PANEL P�E
FASTENER
BEFORE BEAMING AFTER SWING
SEM12001.2 FL11175-R3 Page 19 of 21
his evaluation report is provided for State of Florida product approval under Rule 61 G20-3.. The manufacturer shall notify CREEK
echnical Services, LLC of any product changes'or quality assurance changes throughout the duration for which this report is valid.
his evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
pecifically addressed herein.
Q
�,,CREEK
TECHNICAL SERVICES, LLC
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
ASM-19: 24� ,gaRbck
L'ok
Slope:
1:12 or greater
Deck:
Min. 22 ga. B-Deck (Fy = 33 ksi) for new and existing construction with structural supports
spaced a maximum 5-ft o.c.; Shall be designed by other is accordance FBC
Insulation (optional):
Min. 1" and max. 4" insulation board
Underlayment:
As required in accordance with FBC Section 1507.4.5.1
Attachment:
(2) 1/4" pancake head, self -drilling screws installed per 22 ga. UL90 clip as shown below
with min. 3/4" deck penetration through a 6" x 6", 22 ga. bearing plate
-88 psf when clips spaced max. 24" o.c.
Allowable Pressure:
-151.75 psf when clips spaced max.12" o.c.
Pressure calculated using 2:1 margin of safety per 1504.9
i
Nominal 16 (15,940) -
2 '
T '
5.540 5.20 5.20
Lap Detail:
o,
FACTORYAPPUFD FACTORY APPLIED
SEALANT SEALANT
i
CUp CLIP CLIP ON BEARING PLATE (FLAT)
q
PANEL
I i I F
FASTENER
BEFORE BEAMING AFTER SEAMING
EM12001.2
FL11175-R3
20 of 21
evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
nical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
fically addressed herein.
k
a CREEK
TECHNICAL SERVICES, LLC
REFERENCES
Southeastern Metals Manufacturing Co., Inc.
Metal Roof Systems
Entity
Report No.
Standard
Year
Certified Testing Laboratories (TST1577)
CTLA 11OR-1
TAS 125
2003
Certified Testing Laboratories (TST1577)
CTLA 111 R
TAS 125
2003
Force Engineering and Testing (TST5328)
188-0330T-06D, E
TAS 125
2003
Force Engineering and Testing (TST5328)
188-0331T-06D, E
TAS 125
2003
Force Engineering and Testing (TST5328)
188-0332T-06A, B
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0041-1019-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0041-0812-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0041-00202-10
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
SEM-013-02-02.04
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
SEM-016-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
SEM-018-02-01
TAS 125
2003
LIMITATIONS
1. This evaluation is not for use in the HVHZ.
2. Fire classification is not within the scope of this evaluation
3. Design wind loads shall be determined in accordance with FBC Section 1609.
4. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
5. The maximum fastener spacing for the approved assemblies shall not be exceeded.
6. Reroofing shall be conducted in accordance with FBC Section 1511.
7. Panel materials shall comply with FBC Section 1507.4.3
8. Fasteners shall comply with FBC Section 1507.4.4
9. Installation of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
10. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT'
The products and assemblies evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the
Florida Building Code, 6th Edition (2017) as evidenced in the referenced documents submitted by the named
manufacturer. ,,``GPali YI'R ',' W ..
P w.. 2017.09.25
,.• •GEMS F� ,
�' •' �' • ' 'r 12:31:36
No 74021
-04'00' .
t m Zachary R. Priest, P.E.
� :.. STATE OF Florida Registration No. 74021
T A P•.' �` Organization No. ANE9641
s O N A, ; �0�0
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, now will acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
Zachary R. Priest, P.E. does not have, now will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
SEM12001.2 FL11175-R3 Page 21 of 21
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.